Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Coherence-mediated quantum thermometry in a hybrid circuit quantum electrodynamics architecture

Quantum thermometry plays a critical role in the development of low-temperature sensors and quantum information platforms. Here, in this work, we propose and analyze a hybrid circuit quantum electrodynamics architecture in which a superconducting qubit is dispersively coupled to two distinct bosonic modes: one initialized in a weak coherent state as a phase reference and information buffer and the other coupled to a thermal environment. We show that the qubit serves as a sensitive readout of the probe mode, mapping the interplay between thermal and coherent photon-number fluctuations onto measurable dephasing. This coherence-mediated mechanism enables improved sensitivity to thermal energy fluctuations in the sub-millikelvin regime through Ramsey interferometry. We derive analytic expressions for the probe coherence envelope, compute the quantum Fisher information for temperature estimation, and demonstrate numerically that the presence of a coherent reference enhances the qubit's sensitivity to small changes in thermal photon occupancy. Our results establish a coherence-enabled approach to thermometry and provide a scalable platform for future calorimetric sensing in high-energy physics and quantum metrology.

Zhu, Shaojiang [Fermi National Accelerator Laborat↗

Datasets for Widespread Residential Space Heating Electrification in Texas

In this experiment, we explore long term patterns in electricity demand driven by the dual effects of full electrification of space heating in Texas (by adoption of electric heat pumps), and climate change. We use a predictive model of electricity demand, climate projections, and an open source nodal power system (DC Optimal Power Flow) model of the Electric Reliability Council of Texas (ERCOT) system. Heat pumps are a more energy efficient way of providing space heating and cooling in homes. We attempt to exhaustively investigate the impacts of full residential space heating electrification by adoption of heat pumps for the segment of Texas households that currently rely on fossil fuels (about 40%), while simultaneously incorporating climate change meteorological variables. We explore a range of scenarios of heat pump efficiency and climate uncertainty over a long period of future years (2020-2099). In total, the simulation experiment generates 1,280 simulation years of hourly data. We report and analyze results in form of impacts on residential load, total load, peak load, seasonality of peaking, and reliability measured by occurrence and frequency of loss of load events. While the experiment is for ERCOT, the insights and approach can be applied to other regions. The results from the analysis can inform system planners on a range of potential capacity requirements/ reliability implications and/or risks of full space heating electrification via the adoption of electric heat pumps, given the uncertainty in the scenarios/ climate futures. The dataset includes model output for residential, non residential and total load, and the results from the GO ERCOT model runs for 4 RCP Scenarios (RCP 4.5 Cooler, RCP 4.5 Hotter, RCP 8.5 Cooler, RCP 8.5 Hotter), 4 Heating electrification Scenarios (Base , Standard Efficiency HP, High Efficiency HP, Ultra-High Efficiency HP) over 80 years (2020-2099). The metrological variables at BA scale were weighted weighted using population projections consistent with the SSP3 scenario.

Climate Change↗

Spin squeezing in an ensemble of nitrogen–vacancy centres in diamond

Spin-squeezed states provide a seminal example of how the structure of quantum mechanical correlations can be controlled to produce metrologically useful entanglement. These squeezed states have been demonstrated in a wide variety of quantum systems ranging from atoms in optical cavities to trapped ion crystals. By contrast, despite their numerous advantages as practical sensors, spin ensembles in solid-state materials have yet to be controlled with sufficient precision to generate targeted entanglement such as spin squeezing. Here we report the experimental demonstration of spin squeezing in a solid-state spin system. Our experiments are performed on a strongly interacting ensemble of nitrogen–vacancy colour centres in diamond at room temperature, and squeezing (−0.50 ± 0.13 dB) below the noise of uncorrelated spins is generated by the native magnetic dipole–dipole interaction between nitrogen–vacancy centres. To generate and detect squeezing in a solid-state spin system, we overcome several challenges. First, we develop an approach, using interaction-enabled noise spectroscopy, to characterize the quantum projection noise in our system without directly resolving the spin probability distribution. Second, noting that the random positioning of spin defects severely limits the generation of spin squeezing, we implement a pair of strategies aimed at isolating the dynamics of a relatively ordered sub-ensemble of nitrogen–vacancy centres. Furthermore, our results open the door to entanglement-enhanced metrology using macroscopic ensembles of optically active spins in solids.

Atomic and molecular physics↗

NASA Tech Briefs, January 2009

Tech Briefs are short announcements of innovations originating from research and development activities of the National Aeronautics and Space Administration. They emphasize information considered likely to be transferable across industrial, regional, or disciplinary lines and are issued to encourage commercial application. Topics covered include: The Radio Frequency Health Node Wireless Sensor System; Effects of Temperature on Polymer/Carbon Chemical Sensors; Small CO2 Sensors Operate at Lower Temperature; Tele-Supervised Adaptive Ocean Sensor Fleet; Synthesis of Submillimeter Radiation for Spectroscopy; 100-GHz Phase Switch/Mixer Containing a Slot-Line Transition; Generating Ka-Band Signals Using an X-Band Vector Modulator; SiC Optically Modulated Field-Effect Transistor; Submillimeter-Wave Amplifier Module with Integrated Waveguide Transitions; Metrology System for a Large, Somewhat Flexible Telescope; Economical Implementation of a Filter Engine in an FPGA; Improved Joining of Metal Components to Composite Structures; Machined Titanium Heat-Pipe Wick Structure; Gadolinia-Doped Ceria Cathodes for Electrolysis of CO2; Utilizing Ocean Thermal Energy in a Submarine Robot; Fuel-Cell Power Systems Incorporating Mg-Based H2 Generators; Alternative OTEC Scheme for a Submarine Robot; Sensitive, Rapid Detection of Bacterial Spores; Adenosine Monophosphate-Based Detection of Bacterial Spores; Silicon Microleaks for Inlets of Mass Spectrometers; CGH Figure Testing of Aspherical Mirrors in Cold Vacuums; Series-Coupled Pairs of Silica Microresonators; Precise Stabilization of the Optical Frequency of WGMRs; Formation Flying of Components of a Large Space Telescope; Laser Metrology Heterodyne Phase-Locked Loop; Spatial Modulation Improves Performance in CTIS; High-Performance Algorithm for Solving the Diagnosis Problem; Truncation Depth Rule-of-Thumb for Convolutional Codes; Efficient Method for Optimizing Placement of Sensors.

Source record↗

Interplay Between Time and Energy in Bosonic Noisy Quantum Metrology

Quantum entanglement and coherence often allow for protocols that outperform classical ones in estimating a system’s parameter. When using infinite-dimensional probes (such as a bosonic mode), one could, in principle, obtain infinite precision in a finite time for both classical and quantum protocols, which makes it hard to quantify potential quantum advantage. However, such a situation is unphysical, as it would require infinite resources, so one needs to impose some additional constraint: typically the average energy employed by the probe is finite. Here we treat both energy and time as a resource, showing that, in the presence of noise, there is a nontrivial interplay between the average energy and the time devoted to the estimation. Our results are valid for the most general metrological schemes (e.g., adaptive schemes, which may involve entanglement with external ancillae or any kind of continuous measurement). We apply recently derived precision bounds for all parameters characterizing the paradigmatic case of a bosonic mode, subject to Lindbladian noise. We show how the time employed in the estimation should be partitioned in order to achieve the best possible precision. In most cases, the optimal performance may be obtained without the necessity of adaptivity or entanglement with ancilla. We compare results with classical strategies. Interestingly, for temperature estimation, applying a fast-prepare-and-measure protocol with Fock states provides better scaling with the number of photons than any classical strategy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Degradation of Ta 2 O 5 / SiO 2 dielectric cavity mirrors in ultra-high vacuum

In order for optical cavities to enable strong light-matter interactions for quantum metrology, networking, and scalability in quantum computing systems, their mirrors must have minimal losses. However, high-finesse dielectric cavity mirrors can degrade in ultra-high vacuum (UHV), increasing the challenges of upgrading to cavity-coupled quantum systems. We observe the optical degradation of high-finesse dielectric optical cavity mirrors after high-temperature UHV bake in the form of a substantial increase in surface roughness. We provide an explanation of the degradation through atomic force microscopy (AFM), X-ray fluorescence (XRF), selective wet etching, and optical measurements. We find the degradation is explained by oxygen reduction in Ta 2 O 5 followed by growth of tantalum sub-oxide defects with height to width aspect ratios near ten. We discuss the dependence of mirror loss on surface roughness and finally give recommendations to avoid degradation to allow for quick adoption of cavity-coupled systems.

Optics↗

Semicomputational calculation of Bragg shift in stratified materials

The fiber Bragg grating (FBG) may be viewed as a one dimensional photonic band-gap crystal by virtue of the periodic spatial perturbation imposed on the fiber core dielectric material. Similar to media supporting Bloch waves, the engraved weak index modulation, presenting a periodic “potential” to an incoming guided mode photon of the fiber, yields useful spectral properties that have been the basis for sensing applications and emerging quantum squeezing and solitons. The response of an FBG sensor to arbitrary external stimuli represents a multiphysics problem without a known analytical solution despite the growing use of FBGs in classical and quantum sensing and metrology. Here, we study this problem by first presenting a solid mechanics model for the thermal and elastic states of a stratified material. Additionally, the model considers an embedded optical material domain that represents the Bragg grating, here in the form of an FBG. Using the output of this model, we then compute the optical modes and their temperature- and stress-induced behavior. The developed model is applicable to media of arbitrary shape and composition, including soft matter and materials with nonlinear elasticity and geometric nonlinearity. Finally, we employ the computed surface stress and temperature distributions along the grating to analytically calculate the Bragg shift, which is found to be in reasonable agreement with our experimental measurements.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

NASA Tech Briefs, May 2009

Topics covered include: Valve-"Health"-Monitoring System; Microstrip Antenna for Remote Sensing of Soil Moisture and Sea Surface Salinity; Biomedical Wireless Ambulatory Crew Monitor; Wireless Avionics Packet to Support Fault Tolerance for Flight Applications; Aerobot Autonomy Architecture; Submillimeter Confocal Imaging Active Module; Traveling-Wave Maser for 32 GHz; System Synchronizes Recordings from Separated Video Cameras; Piecewise-Planar Parabolic Reflectarray Antenna; Reducing Interference in ATC Voice Communication; EOS MLS Level 1B Data Processing, Version 2.2; Auto-Generated Semantic Processing Services; Geospatial Authentication; Maneuver Automation Software; Event Driven Messaging with Role-Based Subscriptions; Estimating Relative Positions of Outer-Space Structures; Fabricating PFPE Membranes for Capillary Electrophoresis; Linear Actuator Has Long Stroke and High Resolution; Installing a Test Tap on a Metal Battery Case; Fabricating PFPE Membranes for Microfluidic Valves and Pumps; Room-Temperature-Cured Copolymers for Lithium Battery Gel Electrolytes; Catalysts for Efficient Production of Carbon Nanotubes; Amorphous Silk Fibroin Membranes for Separation of CO2; "Zero-Mass" Noninvasive Pressure Transducers; Radial-Electric-Field Piezoelectric Diaphragm Pumps; Ejector-Enhanced, Pulsed, Pressure-Gain Combustor; Suppressing Ghost Diffraction in E-Beam-Written Gratings; Target-Tracking Camera for a Metrology System; Polarimetric Imaging using Two Photoelastic Modulators; Miniature Wide-Angle Lens for Small-Pixel Electronic Camera; Modal Filters for Infrared Interferometry; Mo(3)Sb(7-x)Te(x) for Thermoelectric Power Generation; Two-Dimensional Quantum Model of a Nanotransistor; Scanning Miniature Microscopes without Lenses; Manipulating Neutral Atoms in Chip-Based Magnetic Traps; Expansion Compression Contacts for Thermoelectric Legs; Processing Electromyographic Signals to Recognize Words; Physical Principle for Generation of Randomness; DSN Beowulf Cluster-Based VLBI Correlator; Hybrid NN/SVM Computational System for Optimizing Designs; Criteria for Modeling in LES of Multicomponent Fuel Flow; Computerized Machine for Cutting Space Shuttle Thermal Tiles; Orbiting Depot and Reusable Lander for Lunar Transportation; FPGA-Based Networked Phasemeter for a Heterodyne Interferometer; Aquarius Digital Processing Unit; Three-Dimensional Optical Coherence Tomography; Benchtop Antigen Detection Technique using Nanofiltration and Fluorescent Dyes; Isolation of Precursor Cells from Waste Solid Fat Tissue; Identification of Bacteria and Determination of Biological Indicators; Further Development of Scaffolds for Regeneration of Nerves; Chemically Assisted Photocatalytic Oxidation System; Use of Atomic Oxygen for Increased Water Contact Angles of Various Polymers for Biomedical Applications; Crashworthy Seats Would Afford Superior Protection; Open-Access, Low-Magnetic-Field MRI System for Lung Research; Microfluidic Mixing Technology for a Universal Health Sensor; Microfluidic Extraction of Biomarkers using Water as Solvent; Microwell Arrays for Studying Many Individual Cells; Droplet-Based Production of Liposomes; and Identifying and Inactivating Bacterial Spores

Source record↗

Ramsey envelope modulation in NV diamond magnetometry

Nitrogen-vacancy (NV) spin ensembles in diamond provide an advanced magnetic sensing platform, with applications in both the physical and life sciences. The development of isotopically engineered 15 NV diamond offers advantages over naturally occurring 14 NV for magnetometry, due to its simpler hyperfine structure. However, for sensing modalities requiring a bias magnetic field not aligned with the sensing NV axis, the absence of a quadrupole moment in the 15 N nuclear spin leads to pronounced envelope modulation effects in time-dependent measurements of 15 NV spin evolution. While such behavior in spin echo experiments are well studied, analogous effects in Ramsey measurements and the implications for magnetometry remain underexplored. Here, we derive the modulated 15 NV Ramsey response to a misaligned bias field, using a simple vector description of the effective magnetic field on the nuclear spin. The predicted modulation properties are then compared to experimental results, revealing significant magnetic sensitivity loss if unaddressed. We demonstrate that double-quantum coherences of the NV S=1 electronic spin states dramatically suppress these envelope modulations, while additionally proving resilient to other parasitic effects such as strain heterogeneity and temperature shifts.

36 MATERIALS SCIENCE↗

Alternatives to ozone depleting refrigerants in test equipment

This paper describes the initial results of a refrigerant retrofit project at the Aerospace Guidance and Metrology Center (AGMC) at Newark Air Force Base, Ohio. The objective is to convert selected types of test equipment to properly operate on hydrofluorocarbon (HFC) alternative refrigerants, having no ozone depleting potential, without compromising system reliability or durability. This paper discusses the primary technical issues and summarizes the test results for 17 different types of test equipment: ten environmental chambers, two ultralow temperature freezers, two coolant recirculators, one temperature control unit, one vapor degreaser, and one refrigerant recovery system. The postconversion performance test results have been very encouraging: system capacity and input power remained virtually unchanged. In some cases, the minimum operating temperature increased by a few degrees as a result of the conversion, but never beyond AGMC's functional requirements.

Hall, Richard L.↗

Whispering Gallery Mode Resonators as Optical Reference Cavities

Highly stabilized lasers are an increasingly valuable tool for metrology. For many applications, however, existing Fabry Perot systems are too bulky and cumbersome. We are investigating the use of miniature monolithic whispering gallery mode resonators as reference cavities for laser stabilization. We seek to exploit the benefit of small size and vibration resistance by suppressing thermally induced frequency fluctuations. We have theoretically investigated the viability of using a thin-film coating to achieve temperature compensation. We have experimentally investigated an active temperature stabilization scheme based on birefringence in a crystalline resonator. We also report progress of laser locking to the resonators.

optical frequency↗

LISA Thermal Design

The Laser Interferometer Space Antenna (LISA) mission, a space based gravitational wave detector, uses laser metrology to measure distance fluctuations between proof masses aboard three spacecraft. The total acceleration disturbance to each proof mass is required to be below 3 x 10(exp -15) meters per second squared per the square root of Hertz. Optical path length variations on each optical bench must be kept below about 3 pm per the square root of Hertz. Noise due to spacecraft thermal distortions, temperature difference variations across proof mass housing, and other thermal effects are expected to be a significant contributors to these noise budgets. The LISA Integrated Modeling team developed a detailed thermal model that is currently being used to drive the design of LISA. Several new thermal analysis techniques are also being developed in order to achieve model accuracies to LISA levels. We present here an overview of the LISA thermal design and modeling efforts. The latest thermal results calculated using the current baseline design of LISA are also discussed.

Merkowitz, Stephen↗

Static metrology of the meter-scale deformable heliostat

This paper describes a heliostat metrology system which is developed based on deflectometry, utilizing a static perforated panel instead of conventional dynamic monitor displays to provide incident rays. The developed method is named static screen deflectometry (SSD). This robust and scalable method is especially valuable for outdoor tests of large reflectors used in concentrating solar-thermal power (CSP) systems. The developed method has been successfully demonstrated on a 2.4 𝑚 × 3.3 𝑚 float glass deformable reflector bent to focus sunlight at 113 𝑚 distance throughout a day. From images obtained from a camera at 50𝑚 distance, the reflector surface was measured to an accuracy of less than 1 𝑚𝑟𝑎𝑑 rms slope error in the full test scope.

14 SOLAR ENERGY↗

High speed ultraviolet digital image correlation (UV-DIC) for dynamic strains at extreme temperatures

Digital Image Correlation (DIC) is a camera-based method of measuring full-field displacements and strains from the surface of a deforming object. It can be applied at any length scale (determined by the lenses) and any time scale (determined by the camera), and because it is non-contacting, it can also be used at temperatures much higher than can be withstood by bonded strain gauges. At extreme temperatures, materials emit light in the form of blackbody radiation, which can saturate the camera sensor. It has previously been shown that the emitted light can be effectively screened by using ultraviolet (UV) cameras, lenses, and filters; however, commercially available UV cameras are relatively slow, which limits the speed of combined UV-DIC measurements. In this study, a UV intensifier was paired with a high-speed camera, and its ability to perform UV-DIC at high temperature and high speed was investigated. The system was compared over three different experiments: (A) a quasi-static thermal expansion test at high temperature, (B) a vibration test at room temperature, and (C) the same vibration test repeated at high temperature. The system successfully performed DIC up to at least 1600 °C at frame rates of 5000 fps, which is more than 100 times faster than other examples of UV-DIC in the literature. In all cases, measurements made using the UV intensifier were much noisier than those made without the intensifier, but the intensifier enabled measurements at temperatures well above those which an unfiltered high-speed camera otherwise saturates.

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, October 2003

Topics covered include: Cryogenic Temperature-Gradient Foam/Substrate Tensile Tester; Flight Test of an Intelligent Flight-Control System; Slat Heater Boxes for Thermal Vacuum Testing; System for Testing Thermal Insulation of Pipes; Electrical-Impedance-Based Ice-Thickness Gauges; Simulation System for Training in Laparoscopic Surgery; Flasher Powered by Photovoltaic Cells and Ultracapacitors; Improved Autoassociative Neural Networks; Toroidal-Core Microinductors Biased by Permanent Magnets; Using Correlated Photons to Suppress Background Noise; Atmospheric-Fade-Tolerant Tracking and Pointing in Wireless Optical Communication; Curved Focal-Plane Arrays Using Back-Illuminated High-Purity Photodetectors; Software for Displaying Data from Planetary Rovers; Software for Refining or Coarsening Computational Grids; Software for Diagnosis of Multiple Coordinated Spacecraft; Software Helps Retrieve Information Relevant to the User; Software for Simulating a Complex Robot; Software for Planning Scientific Activities on Mars; Software for Training in Pre-College Mathematics; Switching and Rectification in Carbon-Nanotube Junctions; Scandia-and-Yttria-Stabilized Zirconia for Thermal Barriers; Environmentally Safer, Less Toxic Fire-Extinguishing Agents; Multiaxial Temperature- and Time-Dependent Failure Model; Cloverleaf Vibratory Microgyroscope with Integrated Post; Single-Vector Calibration of Wind-Tunnel Force Balances; Microgyroscope with Vibrating Post as Rotation Transducer; Continuous Tuning and Calibration of Vibratory Gyroscopes; Compact, Pneumatically Actuated Filter Shuttle; Improved Bearingless Switched-Reluctance Motor; Fluorescent Quantum Dots for Biological Labeling; Growing Three-Dimensional Corneal Tissue in a Bioreactor; Scanning Tunneling Optical Resonance Microscopy; The Micro-Arcsecond Metrology Testbed; Detecting Moving Targets by Use of Soliton Resonances; and Finite-Element Methods for Real-Time Simulation of Surgery.

Source record↗

Probing local electron temperature and density inside a sheared flow stabilized Z-pinch using portable optical Thomson scattering

We report the first optical Thomson scattering measurements inside a high electron temperature (≳1 keV) and moderate electron density (mid 10 16 cm –3 ) plasma. This diagnostic has been built to provide critical plasma parameters, such as electron temperature and density, for Advanced Research Projects Agency-Energy-supported fusion-energy concepts. It uses an 8 J laser at 532 nm in 1.5 ns to measure the high frequency feature of the Thomson scattering profile at 17 locations along the probe axis. It is able to measure electron density from 5 × 10 17 cm –3 to several 10 19 cm –3 and electron temperatures from tens of eV to several keV. Here, in this paper, we describe the design, deployment, and analysis on the sheared flow stabilized Z-pinch machine at Zap Energy named FuZE. The probe beam is aimed at an axial distance of 20 cm from the central electrode and is timed within the temporal envelope of neutron emission. The high temperature and moderate density plasmas generated on FuZE lie in an unconventional regime for Thomson scattering as they are between tokamaks and laser-produced plasmas. We described the analysis considerations in this regime, show that the electron density was below 5 × 10 16 cm –3 at all times during these measurements, and present a sample shot where the inferred electron temperature varied from 167 ± 16 eV to 700 ± 85 eV over 1.6 cm.

47 OTHER INSTRUMENTATION↗

Solid-State Single-Photon Counter

Avalanche photodiode used to detect single photons if cooled to optimum temperature and overbiased beyond breakdown voltage. Offers two to three times sensitvity of photomultiplier tubes commonly used for photon detection. When cooled to reduce number of thermal carriers, avalanche photodiode reverse-biased beyond normal breakdown voltage to give it extremely-high internal gain of 10 to seventh power to 10 to eigth power. Advantages of solid-state devices to applications requiring low-level light detection, optical communication, astronomy, remote sensing, optical metrology, and optical signal processing.

Robinson, D. L.↗

High Speed, Multi-Channel, Thermal Instrument Development in Support of HyspIRI-TIR

The Jet Propulsion Laboratory is currently developing an end-to-end instrument which will provide a proof of concept prototype vehicle for a high data rate, multi-channel, thermal instrument in support of the Hyperspectral Infrared Imager (HyspIRI)-Thermal Infrared (TIR) space mission. HyspIRI mission was recommended by the National Research Council Decadal Survey (DS). The HyspIRI mission includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. The prototype testbed instrument addressed in this effort will only support the TIR. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. Current designs for the HyspIRI-TIR space borne imager utilize eight spectral bands delineated with filters. The system will have 60m ground resolution, 200mK NEDT, 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. The prototype instrument will use mercury cadmium telluride (MCT) technology at the focal plane array in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence high data rates needed for the 5 day repeat. The current HyspIRI requirements dictate a ground knowledge measurement of 30m, so the prototype instrument will tackle this problem with a newly developed interferometeric metrology system. This will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing postprocessing (e.g. geo-rectification computations).

Multi-spectral↗