Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “targeted imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Production of GMP-Compliant Clinical Amounts of Copper-61 Radiopharmaceuticals from Liquid Targets

PET imaging has gained significant momentum in the last few years, especially in the area of oncology, with an increasing focus on metal radioisotopes owing to their versatile chemistry and favourable physical properties. Copper-61 (t1/2 = 3.33 h, 61% β+, Emax = 1.216 MeV) provides unique advantages versus the current clinical standard (i.e., gallium-68) even though, until now, no clinical amounts of 61Cu-based radiopharmaceuticals, other than thiosemicarbazone-based molecules, have been produced. This study aimed to establish a routine production, using a standard medical cyclotron, for a series of widely used somatostatin analogues, currently labelled with gallium-68, that could benefit from the improved characteristics of copper-61. We describe two possible routes to produce the radiopharmaceutical precursor, either from natural zinc or enriched zinc-64 liquid targets and further synthesis of [61Cu]Cu-DOTA-NOC, [61Cu]Cu-DOTA-TOC and [61Cu]Cu-DOTA-TATE with a fully automated GMP-compliant process. The production from enriched targets leads to twice the amount of activity (3.28 ± 0.41 GBq vs. 1.84 ± 0.24 GBq at EOB) and higher radionuclidic purity (99.97% vs. 98.49% at EOB). Our results demonstrate, for the first time, that clinical doses of 61Cu-based radiopharmaceuticals can easily be obtained in centres with a typical biomedical cyclotron optimised to produce 18F-based radiopharmaceuticals.

Fonseca, Alexandra I. (ORCID:000000031924178X)↗

Target Optimal Aperture Selection

This document describes the computation of optimal pixels for planetary transit targets. The method we describe is based on that used in the End-to-End Model (ETEM), which simulates Kepler science output. An optimal aperture for a target is defined as the set of pixels which maximizes the signal-to-noise ratio (SNR) for that target. The optimal aperture for a target is determined by using catalog data to generate, for that target, a synthetic image with all background stars and signals and a second synthetic image with the target star's flux only. These images are incorporated into a noise model, from which the SNR of each pixel is computed. The pixels around a target are summed in an order that maximizes the SNR with each term. As dimmer and dimmer pixels contribute to this sum, the SNR reaches a maximum and further terms decrease the SNR. The set of pixels whose SNR sums to this maximum value defines the optimal aperture.

Bryson, Stephen↗

Hiding-in-Plain-Sight (HiPS) Attack on CLIP for Targetted Object Removal from Images

Machine learning models are known to be vulnerable to adversarial attacks, but prior works have mostly focused on single-modalities. With the rise of large multi-modal models (LMMs) like CLIP, which combine vision and language capabilities, new vulnerabilities have emerged. However, these multimodal targeted attacks aim to completely change the model's output to what the adversary wants. In many realistic scenarios, an adversary might seek to make only subtle modifications to the output, so that the changes go unnoticed by downstream models or even by humans. We introduce Hiding-in-Plain-Sight (HiPS) attacks, a novel class of adversarial attacks that subtly modifies model predictions by selectively concealing target object(s), as if the target object was absent from the scene. We propose two HiPS attack variants, HiPS-cls and HiPS-cap, and demonstrate their effectiveness in transferring to downstream image captioning models, such as CLIP-Cap, for targeted object removal from image captions.

Daw, Arka [ORNL] (ORCID:0009000633191271)↗

Light-Directed Ranging System Implementing Single Camera System for Telerobotics Applications

A laser-directed ranging system has utility for use in various fields, such as telerobotics applications and other applications involving physically handicapped individuals. The ranging system includes a single video camera and a directional light source such as a laser mounted on a camera platform, and a remotely positioned operator. In one embodiment, the position of the camera platform is controlled by three servo motors to orient the roll axis, pitch axis and yaw axis of the video cameras, based upon an operator input such as head motion. The laser is offset vertically and horizontally from the camera, and the laser/camera platform is directed by the user to point the laser and the camera toward a target device. The image produced by the video camera is processed to eliminate all background images except for the spot created by the laser. This processing is performed by creating a digital image of the target prior to illumination by the laser, and then eliminating common pixels from the subsequent digital image which includes the laser spot. A reference point is defined at a point in the video frame, which may be located outside of the image area of the camera. The disparity between the digital image of the laser spot and the reference point is calculated for use in a ranging analysis to determine range to the target.

Wells, Dennis L.↗

To image, or not to image: class-specific diffractive cameras with all-optical erasure of undesired objects

Abstract Privacy protection is a growing concern in the digital era, with machine vision techniques widely used throughout public and private settings. Existing methods address this growing problem by, e.g., encrypting camera images or obscuring/blurring the imaged information through digital algorithms. Here, we demonstrate a camera design that performs class-specific imaging of target objects with instantaneous all-optical erasure of other classes of objects. This diffractive camera consists of transmissive surfaces structured using deep learning to perform selective imaging of target classes of objects positioned at its input field-of-view. After their fabrication, the thin diffractive layers collectively perform optical mode filtering to accurately form images of the objects that belong to a target data class or group of classes, while instantaneously erasing objects of the other data classes at the output field-of-view. Using the same framework, we also demonstrate the design of class-specific permutation and class-specific linear transformation cameras, where the objects of a target data class are pixel-wise permuted or linearly transformed following an arbitrarily selected transformation matrix for all-optical class-specific encryption, while the other classes of objects are irreversibly erased from the output image. The success of class-specific diffractive cameras was experimentally demonstrated using terahertz (THz) waves and 3D-printed diffractive layers that selectively imaged only one class of the MNIST handwritten digit dataset, all-optically erasing the other handwritten digits. This diffractive camera design can be scaled to different parts of the electromagnetic spectrum, including, e.g., the visible and infrared wavelengths, to provide transformative opportunities for privacy-preserving digital cameras and task-specific data-efficient imaging.

47 OTHER INSTRUMENTATION↗

Ranging Apparatus and Method Implementing Stereo Vision System

A laser-directed ranging system for use in telerobotics applications and other applications involving physically handicapped individuals. The ranging system includes a left and right video camera mounted on a camera platform, and a remotely positioned operator. The position of the camera platform is controlled by three servo motors to orient the roll axis, pitch axis and yaw axis of the video cameras, based upon an operator input such as head motion. A laser is provided between the left and right video camera and is directed by the user to point to a target device. The images produced by the left and right video cameras are processed to eliminate all background images except for the spot created by the laser. This processing is performed by creating a digital image of the target prior to illumination by the laser, and then eliminating common pixels from the subsequent digital image which includes the laser spot. The horizontal disparity between the two processed images is calculated for use in a stereometric ranging analysis from which range is determined.

Li, Larry C.↗

A photosensitive sustainable lignin nanoplatform for multimodal image-guided mitochondria-targeted photodynamic and photothermal therapy

Photoactivated nanocarriers exhibit significant potential for anticancer therapy, but complex design strategies, unsustainable substrates, and short wavelengths limit their practical application. Here, we designed a new lignin-derived photoactivated nanomaterial that exploits the sensitivity of the β-O-4 bond of lignin to singlet oxygen. This sustainable product was loaded with mitochondria-targeting chlorin e6 and black phosphorus quantum dots (BPQDs) to produce BPQDs@N-LgC NPs, which were used for mitochondria-targeted fluorescence/photoacoustic-guided photothermal and photodynamic therapy. When irradiated at 808 nm, the BPQDs in BPQDs@N-LgC NPs exhibited good photothermal conversion, which allowed photoacoustic imaging and inhibited tumor growth. When irradiated at 660 nm, the BPQDs@N-LgC NPs generated fluorescence and reactive oxygen species, which allowed photoluminescence imaging and further inhibited tumor growth. Cleavage of the β-O-4 bond of lignin by photo-triggered reactive oxygen species degraded the NPs and released the BPQDs, facilitating rapid excretion of the therapeutic nanomaterials. Our rationally designed BPQDs@N-LgC NPs exhibited good therapeutic efficacy, both in vitro and in vivo.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Method and system for automated plant surveillance and manipulation

A method and a system for automated plant surveillance and manipulation are provided. Pursuant to the method and the system, images of target plants are obtained through a machine vision system having multiple cameras. The obtained images of the target plants are processed to determine tissue candidates of the target plants and to determine a position and an orientation of each tissue candidate. A tool is manipulated, based on the position and the orientation of each tissue candidate, to excise each tissue candidate to obtain tissue samples. The tissue samples are transported for subsequently manipulation including live processing of the tissue samples or destructive processing of the tissue samples.

Kalluri, Udaya C.↗

A New Lunar Globe as Seen by the Moon Mineralogy Mapper: Image Coverage Spectral Dimensionality and Statistical Anomalies

The Moon Mineralogy Mapper (M3), a NASA Discovery Mission of Opportunity, was launched October 22, 2008 from Shriharikota in India on board the Indian ISRO Chandrayaan- 1 spacecraft for a nominal two-year mission in a 100-km polar lunar orbit. M3 is a high-fidelity imaging spectrometer with 260 spectral bands in Target Mode and 85 spectral bands in a reduced-resolution Global Mode. Target Mode pixel sizes are nominally 70 meters and Global pixels (binned 2 by 2) are 140 meters, from the planned 100-km orbit. The mission was cut short, just before halfway, in August, 2009 when the spacecraft ceased operations. Despite the abbreviated mission and numerous technical and scientific challenges during the flight, M3 was able to cover more than 95% of the Moon in Global Mode. These data, presented and analyzed here as a global whole, are revolutionizing our understanding of the Moon. Already, numerous discoveries relating to volatiles and unexpected mineralogy have been published [1], [2], [3]. The rich spectral and spatial information content of the M3 data indicates that many more discoveries and an improved understanding of the mineralogy, geology, photometry, thermal regime and volatile status of our nearest neighbor are forthcoming from these data. Sadly, only minimal high-resolution Target Mode images were acquired, as these were to be the focus of the second half of the mission. This abstract gives the reader a global overview of all the M3 data that were collected and an introduction to their rich spectral character and complexity. We employ a Principal Components statistical method to assess the underlying dimensionality of the Moon as a whole, as seen by M3, and to identify numerous areas that are low-probability targets and thus of potential interest to selenologists.

Boardman, J. W.↗

Covalent Surface Modification Effects on Single‐Walled Carbon Nanotubes for Targeted Sensing and Optical Imaging

Abstract Optical nanoscale technologies often implement covalent or noncovalent strategies for the modification of nanoparticles, whereby both functionalizations are leveraged for multimodal applications but can affect the intrinsic fluorescence of nanoparticles. Specifically, single‐walled carbon nanotubes (SWCNTs) can enable real‐time imaging and cellular delivery; however, the introduction of covalent SWCNT sidewall functionalizations often attenuates SWCNT fluorescence. Recent advances in SWCNT covalent functionalization chemistries preserve the SWCNT's pristine graphitic lattice and intrinsic fluorescence, and here, such covalently functionalized SWCNTs maintain intrinsic fluorescence‐based molecular recognition of neurotransmitter and protein analytes. The covalently modified SWCNT nanosensor preserves its fluorescence response towards its analyte for certain nanosensors, presumably dependent on the intermolecular interactions between SWCNTs or the steric hindrance introduced by the covalent functionalization that hinders noncovalent interactions with the SWCNT surface. These SWCNT nanosensors are further functionalized via their covalent handles with a targeting ligand, biotin, to self‐assemble on passivated microscopy slides, and these dual‐functionalized SWCNT materials are explored for future use in multiplexed sensing and imaging applications.

Chio, Linda↗

Preliminary clustering properties of the DESI BGS bright targets using DR9 Legacy Imaging Surveys

ABSTRACT We characterize the selection cuts and clustering properties of a magnitude-limited sample of bright galaxies that is part of the Bright Galaxy Survey (BGS) of the Dark Energy Spectroscopic Instrument (DESI) using the ninth data release of the Legacy Imaging Surveys (DR9). We describe changes in the DR9 selection compared to the DR8 one and we also compare the DR9 selection in three distinct regions: BASS/MzLS in the north Galactic Cap (NGC), DECaLS in the NGC, and DECaLS in the south Galactic Cap (SGC). We investigate the systematics associated with the selection and assess its completeness by matching the BGS targets with the Galaxy and Mass Assembly (GAMA) survey. We measure the angular clustering for the overall bright sample (rmag ≤ 19.5) and as function of apparent magnitude and colour. This enables to determine the clustering strength r0 and slope γ by fitting a power-law model that can be used to generate accurate mock catalogues for this tracer. We use a counts-in-cells technique to explore higher order statistics and cross-correlations with external spectroscopic data sets in order to check the evolution of the clustering with redshift and the redshift distribution of the BGS targets using clustering redshifts. While this work validates the properties of the BGS bright targets, the final target selection pipeline and clustering properties of the entire DESI BGS will be fully characterized and validated with the spectroscopic data of Survey Validation.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep-learning-based workflow for boundary and small target segmentation in digital rock images using UNet++ and IK-EBM

We report three-dimensional (3D) X-ray micro-computed tomography (μCT) has been widely used in petroleum engineering because it can provide detailed pore structural information for a reservoir rock, which can be imported into a pore-scale numerical model to simulate the transport and distribution of multiple fluids in the pore space. The partial volume blurring (PVB) problem is a major challenge in segmenting raw μCT images of rock samples, which impacts boundaries and small targets near the resolution limit. We developed a deep-learning (DL)-based workflow for accurate and fast partial volume segmentation. The DL model's performance depends primarily on the training data quality and model architecture. This study employed the entropy-based-masking indicator kriging (IK-EBM) to segment 3D Berea sandstone images as training datasets. The comparison between IK-EBM and manual segmentation using a 3D synthetic sphere pack, which had a known ground truth, showed that IK-EBM had higher accuracy on partial volume segmentation. We then trained and tested the UNet++ model, a state-of-the-art supervised encoder-decoder model, for binary (i.e., void and solid) and four-class segmentation. We compared the UNet++ with the commonly used U-Net and wide U-Net models and showed that the UNet++ had the best performance in terms of pixel-wise and physics-based evaluation metrics. Specifically, boundary-scaled accuracy demonstrated that the UNet++ architecture outperformed the regular U-Net architecture in the segmentation of pixels near boundaries and small targets, which were subjected to the PVB effect. Feature map visualization illustrated that the UNet++ bridged the semantic gaps between the feature maps extracted at different depths of the network, thereby enabling faster convergence and more accurate extraction of fine-scale features. The developed workflow significantly enhances the performance of supervised encoder-decoder models in partial volume segmentation, which has extensive applications in fundamental studies of subsurface energy, water, and environmental systems.

02 PETROLEUM↗

Image quality against metric capability of an aerial camera

Glass plate targets containing multiple contrast three bar patterns and a military standard resolution target were photographed through a light-source collimator-camera system. The glass plate targets and images were then scanned. Through a computer plotting program selected portions of the scanned items were presented. The plots were then measured and analyzed to obtain information of image quality parameters and effects. The measurement errors are discussed together with aspects of resolution determination.

Ghosh, S. K.↗

Generic Sensor Modeling Using Pulse Method

Recent development of high spatial resolution satellites such as IKONOS, Quickbird and Orbview enable observation of the Earth's surface with sub-meter resolution. Compared to the 30 meter resolution of Landsat 5 TM, the amount of information in the output image was dramatically increased. In this era of high spatial resolution, the estimation of spatial quality of images is gaining attention. Historically, the Modulation Transfer Function (MTF) concept has been used to estimate an imaging system's spatial quality. Sometimes classified by target shapes, various methods were developed in laboratory environment utilizing sinusoidal inputs, periodic bar patterns and narrow slits. On-orbit sensor MTF estimation was performed on 30-meter GSD Landsat4 Thematic Mapper (TM) data from the bridge pulse target as a pulse input . Because of a high resolution sensor s small Ground Sampling Distance (GSD), reasonably sized man-made edge, pulse, and impulse targets can be deployed on a uniform grassy area with accurate control of ground targets using tarps and convex mirrors. All the previous work cited calculated MTF without testing the MTF estimator's performance. In previous report, a numerical generic sensor model had been developed to simulate and improve the performance of on-orbit MTF estimating techniques. Results from the previous sensor modeling report that have been incorporated into standard MTF estimation work include Fermi edge detection and the newly developed 4th order modified Savitzky-Golay (MSG) interpolation technique. Noise sensitivity had been studied by performing simulations on known noise sources and a sensor model. Extensive investigation was done to characterize multi-resolution ground noise. Finally, angle simulation was tested by using synthetic pulse targets with angles from 2 to 15 degrees, several brightness levels, and different noise levels from both ground targets and imaging system. As a continuing research activity using the developed sensor model, this report was dedicated to MTF estimation via pulse input method characterization using the Fermi edge detection and 4th order MSG interpolation method. The relationship between pulse width and MTF value at Nyquist was studied including error detection and correction schemes. Pulse target angle sensitivity was studied by using synthetic targets angled from 2 to 12 degrees. In this report, from the ground and system noise simulation, a minimum SNR value was suggested for a stable MTF value at Nyquist for the pulse method. Target width error detection and adjustment technique based on a smooth transition of MTF profile is presented, which is specifically applicable only to the pulse method with 3 pixel wide targets.

Helder, Dennis L.↗

Design and synthesis of astatinated benzothiazole compounds for their potential use in Targeted Alpha Therapy (TAT) strategies to treat Alzheimer's disease-associated amyloid plaques

Alzheimer's disease (AD) is a terminal neurodegenerative disease characterized by the buildup of amyloid fibrils, amorphous aggregates and tauopathies. Several treatment modalities, which rely on various biological processes to reduce disease burden, have been largely ineffective at treating Alzheimer's disease. Targeted alpha therapy (TAT) has demonstrated positive results in the treatment of cancer. Benzothiazole derivatives have been successfully shown to target these plaques and are used in several imaging applications. One such derivative, Flutemetamol (Vizamyl TM ) is an FDA approved diagnostic tool for PET imaging of AD-associated plaques. We report the radiolabeling of benzothiazole derivatives with 211 At, a 7.2 h alpha emitting radionuclide, using a copper catalyzed reaction with a boronic acid precursor molecule. In conclusion, our final compound [ 211 At]3'-At-PIB-OMe had a radiochemical yield of 55% and was found to be stable for at least 3 h in phosphate buffered saline.

62 RADIOLOGY AND NUCLEAR MEDICINE↗