Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “systematic errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characterization of OCO-2 and ACOS-GOSAT biases and errors for flux estimates

We characterize the magnitude of seasonally and spatially varying biases in the National Aeronautics and Space Administration (NASA) Orbiting Carbon Observatory-2 (OCO-2) Version 8 (v8) and the Atmospheric CO2 Observations from Space (ACOS) Greenhouse Gas Observing SATellite (GOSAT) version 7.3 (v7.3) satellite CO2 retrievals by comparisons to measurements collected by the Total Carbon Column Observing Network (TCCON), Atmospheric Tomography (ATom) experiment, and National Oceanic and Atmospheric Administration (NOAA) Earth System Research Laboratory (ESRL) and U. S. Department of Energy (DOE) aircraft, and surface stations. Although the ACOS-GOSAT estimates of the column averaged carbon dioxide (CO2) dry air mole fraction (XCO2) have larger random errors than the OCO-2 XCO2 estimates, and the space-based estimates over land have larger random errors than those over ocean, the systematic errors are similar across both satellites and surface types, 0.6 ± 0.1 ppm. We find similar estimates of systematic error whether dynamic versus geometric coincidences or ESRL/DOE aircraft versus TCCON are used for validation (over land), once validation and co-location errors are accounted for. We also find that areas with sparse throughput of good quality data (due to quality flags and preprocessor selection) over land have ~double the error of regions of high-throughput of good quality data. We characterize both raw and bias-corrected results, finding that bias correction improves systematic errors by a factor of 2 for land observations and improves errors by ~0.2 ppm for ocean. We validate the lowermost tropospheric (LMT) product for OCO-2 and ACOS-GOSAT by comparison to aircraft and surface sites, finding systematic errors of ~1.1 ppm, while having 2-3 times the variability of XCO2. We characterize the time and distance scales of correlations for OCO-2 XCO2 errors, and find error correlations on scales of 0.3 degrees, 5-10 degrees, and 60 days. We find comparable scale lengths for the bias correction term. Assimilation of the OCO-2 bias correction term is used to estimate flux errors resulting from OCO-2 seasonal biases, finding annual flux errors on the order of 0.3 and 0.4 PgC/yr for Transcom-3 ocean and land regions, respectively.

Susan S Kulawik↗

Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy

Purpose: To investigate the applicability of 3-dimensional (3D) surface imaging for image guidance in deep-inspiration breath-hold radiation therapy (DIBH-RT) for patients with left-sided breast cancer. For this purpose, setup data based on captured 3D surfaces was compared with setup data based on cone beam computed tomography (CBCT). Methods and Materials: Twenty patients treated with DIBH-RT after breast-conserving surgery (BCS) were included. Before the start of treatment, each patient underwent a breath-hold CT scan for planning purposes. During treatment, dose delivery was preceded by setup verification using CBCT of the left breast. 3D surfaces were captured by a surface imaging system concurrently with the CBCT scan. Retrospectively, surface registrations were performed for CBCT to CT and for a captured 3D surface to CT. The resulting setup errors were compared with linear regression analysis. For the differences between setup errors, group mean, systematic error, random error, and 95% limits of agreement were calculated. Furthermore, receiver operating characteristic (ROC) analysis was performed. Results: Good correlation between setup errors was found: R{sup 2}=0.70, 0.90, 0.82 in left-right, craniocaudal, and anterior-posterior directions, respectively. Systematic errors were {<=}0.17 cm in all directions. Random errors were {<=}0.15 cm. The limits of agreement were -0.34-0.48, -0.42-0.39, and -0.52-0.23 cm in left-right, craniocaudal, and anterior-posterior directions, respectively. ROC analysis showed that a threshold between 0.4 and 0.8 cm corresponds to promising true positive rates (0.78-0.95) and false positive rates (0.12-0.28). Conclusions: The results support the application of 3D surface imaging for image guidance in DIBH-RT after BCS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Random and systematic measurement errors in acoustic impedance as determined by the transmission line method

The effect of random and systematic errors associated with the measurement of normal incidence acoustic impedance in a zero-mean-flow environment was investigated by the transmission line method. The influence of random measurement errors in the reflection coefficients and pressure minima positions was investigated by computing fractional standard deviations of the normalized impedance. Both the standard techniques of random process theory and a simplified technique were used. Over a wavelength range of 68 to 10 cm random measurement errors in the reflection coefficients and pressure minima positions could be described adequately by normal probability distributions with standard deviations of 0.001 and 0.0098 cm, respectively. An error propagation technique based on the observed concentration of the probability density functions was found to give essentially the same results but with a computation time of about 1 percent of that required for the standard technique. The results suggest that careful experimental design reduces the effect of random measurement errors to insignificant levels for moderate ranges of test specimen impedance component magnitudes. Most of the observed random scatter can be attributed to lack of control by the mounting arrangement over mechanical boundary conditions of the test sample.

Parrott, T. L.↗

SYSTEMATIC CONTINUUM ERRORS IN THE Ly{alpha} FOREST AND THE MEASURED TEMPERATURE-DENSITY RELATION

Continuum fitting uncertainties are a major source of error in estimates of the temperature-density relation (usually parameterized as a power-law, T {proportional_to} {Delta}{sup {gamma}-1}) of the intergalactic medium through the flux probability distribution function (PDF) of the Ly{alpha} forest. Using a simple order-of-magnitude calculation, we show that few percent-level systematic errors in the placement of the quasar continuum due to, e.g., a uniform low-absorption Gunn-Peterson component could lead to errors in {gamma} of the order of unity. This is quantified further using a simple semi-analytic model of the Ly{alpha} forest flux PDF. We find that under(over)estimates in the continuum level can lead to a lower (higher) measured value of {gamma}. By fitting models to mock data realizations generated with current observational errors, we find that continuum errors can cause a systematic bias in the estimated temperature-density relation of ({delta}({gamma})) Almost-Equal-To -0.1, while the error is increased to {sigma}{sub {gamma}} Almost-Equal-To 0.2 compared to {sigma}{sub {gamma}} Almost-Equal-To 0.1 in the absence of continuum errors.

79 ASTRONOMY AND ASTROPHYSICS↗

PHYSICAL PROPERTIES OF THE 0.94-DAY PERIOD TRANSITING PLANETARY SYSTEM WASP-18

We present high-precision photometry of five consecutive transits of WASP-18, an extrasolar planetary system with one of the shortest orbital periods known. Through the use of telescope defocusing we achieve a photometric precision of 0.47-0.83 mmag per observation over complete transit events. The data are analyzed using the JKTEBOP code and three different sets of stellar evolutionary models. We find the mass and radius of the planet to be M {sub b} = 10.43 +- 0.30 +- 0.24 M {sub Jup} and R {sub b} = 1.165 +- 0.055 +- 0.014 R {sub Jup} (statistical and systematic errors), respectively. The systematic errors in the orbital separation and the stellar and planetary masses, arising from the use of theoretical predictions, are of a similar size to the statistical errors and set a limit on our understanding of the WASP-18 system. We point out that seven of the nine known massive transiting planets (M {sub b} > 3 M {sub Jup}) have eccentric orbits, whereas significant orbital eccentricity has been detected for only four of the 46 less-massive planets. This may indicate that there are two different populations of transiting planets, but could also be explained by observational biases. Further radial velocity observations of low-mass planets will make it possible to choose between these two scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

Detailed study of the K{sub L}{yields}{pi}{sup 0}{pi}{sup 0}{pi}{sup 0} Dalitz plot

Using a sample of 68.3x10{sup 6} K{sub L}{yields}{pi}{sup 0}{pi}{sup 0}{pi}{sup 0} decays collected in 1996-1999 by the KTeV (E832) experiment at Fermilab, we present a detailed study of the K{sub L}{yields}{pi}{sup 0}{pi}{sup 0}{pi}{sup 0} Dalitz plot density. We report the first observation of interference from K{sub L}{yields}{pi}{sup +}{pi}{sup -}{pi}{sup 0} decays in which {pi}{sup +}{pi}{sup -} rescatters to {pi}{sup 0}{pi}{sup 0} in a final-state interaction. This rescattering effect is described by the Cabibbo-Isidori model, and it depends on the difference in pion scattering lengths between the isospin I=0 and I=2 states, a{sub 0}-a{sub 2}. Using the Cabibbo-Isidori model, and fixing (a{sub 0}-a{sub 2})m{sub {pi}{sup +}}=0.268{+-}0.017 as measured by the CERN-NA48 collaboration, we present the first measurement of the K{sub L}{yields}{pi}{sup 0}{pi}{sup 0}{pi}{sup 0} quadratic slope parameter that accounts for the rescattering effect: h{sub 000}=(+0.59{+-}0.20{sub stat}{+-}0.48{sub syst}{+-}1.06{sub ext})x10{sup -3}, where the uncertainties are from data statistics, KTeV systematic errors, and external systematic errors. Fitting for both h{sub 000} and a{sub 0}-a{sub 2}, we find h{sub 000}=(-2.09{+-}0.62{sub stat}{+-}0.72{sub syst}{+-}0.28{sub ext})x10{sup -3}, and m{sub {pi}{sup +}}(a{sub 0}-a{sub 2})=0.215{+-}0.014{sub stat}{+-}0.025{sub syst}{+-}0.006{sub ext}; our value for a{sub 0}-a{sub 2} is consistent with that from NA48.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of inclusive jet and dijet production in p p collisions at s = 7 TeV using the ATLAS detector

CERN-LHC. Measurements of the inclusive jet and di-jet cross sections in proton-proton collisions at a centre-of-mass energy of 7 TeV. The analysis is based on the 2010 data sample with a total integrated luminosity of 37 pb^{-1}. The anti-KT algorithm is used for jet clustering with data given using both the parameters R=0.4 and R=0.6. Double-differential cross sections are given as a function of the inclusive jet PT in rapidity (y) bins and of the di-jet invariant mass in bins of half of the rapidity separation of the two jets (y*). Details of the systematic errors and their correlations are given in the link below. In the tables the first (sys) error is the correlated (in PT) systematic error and the second is the uncorrelated systematic error, both produced by combining the relevant errors in quadrature.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proton Scattering in NOvA Test Beam

The NuMI Off-axis $\nu_e$ Appearance (NOvA) experiment is a two-detector, long baseline, neutrino oscillation experiment, which aims to make a determination of the neutrino mass ordering, the octant of $\theta_{23}$, and measure possible charge-parity (CP) violation. Determining these parameters is a step towards answering some of the fundamental questions about neutrinos. Are neutrinos their own antiparticle? Could neutrinos be responsible for the matter-antimatter asymmetry of the universe? How do neutrinos get their mass? Answering these questions requires precise measurements of the parameters that govern how neutrinos behave, namely the mass squared splittings, mixing angles, and possible CP-violating phase factor in the PNMS matrix. Reaching high precision requires minimizing both statistical and systematic errors. As NOvA continues to accumulate data, the sizes of our statistical errors continue to shrink such that in a couple of years they will be comparable to our systematic errors. NOvA's current systematic errors are dominated by energy and calibration uncertainties. The Test Beam program was initiated to address these uncertainties by assessing the detector response in an environment where more parameters of the incoming particles are known. One of the main goals of the Test Beam program is to garner a better understanding of our systematic errors, particularly in energy measurement and detector response, so that the modeling of these parameters can be improved. I studied protons in the Test Beam Detector with momenta around \unit[1]{GeV/c}, the high end of the momentum range relevant to quasielastic neutrino interactions in NOvA. One question this sample can help to answer is if we correctly simulate the fraction of protons that have an inelastic scattering interaction versus ranging out. If protons inelastically scatter at different rates in our simulation and data, the correction applied to the hadronic system when reconstructing neutrino energy could be inaccurate, since events with inelastic scattering will have less visible energy in the detector. This is particularly important for quasielastic $\nu_\mu$ events, which have the lowest hadronic energy resolution, and therefore give us our best measurements of $\Delta m_{32}^2$ and $\theta_{23}$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

ELLIPTICAL WEIGHTED HOLICs FOR WEAK LENSING SHEAR MEASUREMENT. III. THE EFFECT OF RANDOM COUNT NOISE ON IMAGE MOMENTS IN WEAK LENSING ANALYSIS

This is the third paper on the improvement of systematic errors in weak lensing analysis using an elliptical weight function, referred to as E-HOLICs. In previous papers, we succeeded in avoiding errors that depend on the ellipticity of the background image. In this paper, we investigate the systematic error that depends on the signal-to-noise ratio of the background image. We find that the origin of this error is the random count noise that comes from the Poisson noise of sky counts. The random count noise makes additional moments and centroid shift error, and those first-order effects are canceled in averaging, but the second-order effects are not canceled. We derive the formulae that correct this systematic error due to the random count noise in measuring the moments and ellipticity of the background image. The correction formulae obtained are expressed as combinations of complex moments of the image, and thus can correct the systematic errors caused by each object. We test their validity using a simulated image and find that the systematic error becomes less than 1% in the measured ellipticity for objects with an IMCAT significance threshold of {nu} {approx} 11.7.

79 ASTRONOMY AND ASTROPHYSICS↗

RADII OF RAPIDLY ROTATING STARS, WITH APPLICATION TO TRANSITING-PLANET HOSTS

The currently favored method for estimating radii and other parameters of transiting-planet host stars is to match theoretical models to observations of the stellar mean density rho{sub *}, the effective temperature T{sub eff}, and the composition parameter [Z]. This explicitly model-dependent approach is based on readily available observations, and results in small formal errors. Its performance will be central to the reliability of results from ground-based transit surveys such as TrES, HAT, and SuperWASP, as well as to the space-borne missions MOST, CoRoT, and Kepler. Here, I use two calibration samples of stars (eclipsing binaries (EBs) and stars for which asteroseismic analyses are available) having well-determined masses and radii to estimate the accuracy and systematic errors inherent in the rho{sub *} method. When matching to the Yonsei-Yale stellar evolution models, I find the most important systematic error results from selection bias favoring rapidly rotating (hence probably magnetically active) stars among the EB sample. If unaccounted for, this bias leads to a mass-dependent underestimate of stellar radii by as much as 4% for stars of 0.4 M{sub sun}, decreasing to zero for masses above about 1.4 M{sub sun}. Relative errors in estimated stellar masses are three times larger than those in radii. The asteroseismic sample suggests (albeit with significant uncertainty) that systematic errors are small for slowly rotating, inactive stars. Systematic errors arising from failings of the Yonsei-Yale models of inactive stars probably exist, but are difficult to assess because of the small number of well-characterized comparison stars having low mass and slow rotation. Poor information about [Z] is an important source of random error, and may be a minor source of systematic error as well. With suitable corrections for rotation, it is likely that systematic errors in the rho{sub *} method can be comparable to or smaller than the random errors, yielding radii that are accurate to about 2% for most stars.

79 ASTRONOMY AND ASTROPHYSICS↗

SPT-3G D1: Maps of the millimeter-wave sky from 2019 and 2020 observations of the SPT-3G Main field

Maps of the sky in millimeter wavelengths contain rich information on cosmology through anisotropies of the cosmic microwave background (CMB). Creating multifrequency sky maps of anisotropies in the $I$, $Q$, and $U$ Stokes parameters is one of the first steps of CMB cosmology analyses. In this work, we describe the production and validation of a set of sky maps from the South Pole Telescope's third-generation camera, SPT-3G. The maps are from data taken in frequency bands centered at 95, 150, and 220 GHz and taken during the first two years, 2019 and 2020, of the SPT-3G Main survey, which covers $4\%$ of the sky. We applied high-pass filters to time series of individual detectors and binned the filtered time series samples into map pixels. After that, we calibrated and cleaned the maps to reduce known systematic errors. In addition, we searched for other systematic errors through null tests and mitigated a significant systematic error detected therein. The white noise levels of the full-depth maps of the $I$ Stokes parameter are $5.4$, $4.4$, and $16.2$$\mathrm{μK}$-$\mathrm{arcmin}$ in the 95, 150, and 220 GHz bands, respectively, and $8.4$, $6.6$, and $25.8$$\mathrm{μK}$-$\mathrm{arcmin}$ for $Q/U$. These maps are the deepest to date used for measurements of mid-to-high-$\ell$ primary temperature and $E$-mode polarization CMB anisotropies, and reconstructions of the CMB gravitational lensing potential. We make these maps and supporting data products publicly accessible.

Quan, W. [Argonne (main); Chicago U., EFI; Chicago↗

A measurement of the Hubble constant from the X-ray properties and the Sunyaev-Zel'dovich effect of Abell 2218

The distance of the cluster of galaxies Abell 2218, and hence the value of the Hubble constant, has been measured by comparing the X-ray properties and the Sunyaev-Zel'dovich effect of the cluster. The result for the Hubble constant is H(sub zero) = 65 +/- 25 km/s/MPC, where the error includes the random and systematic errors, combined in quadrature, and the largest contributions to the overall error come from systematic errors in the Sunyaev-Zel'dovich effect data and in the X-ray spectrum of the cluster. The X-ray and Sunyaev-Zel'dovich effect data are consistent with the same model for the intergalactic medium in Abell 2218 (an isothermal Beta-model with Beta is about 0.65 and cluster core radius about 1.0 min). A prevous report of a smaller Hubble constant, found by applying the same method on the same cluster, is shown to be based on a model for the cluster gas that is inconsistent with the Einstein IPC data. The present result for the Hubble constant is consistent with the value found earlier for the cluster Abell 665: by combining the results of the method for both clusters we conclude that the value of the Hubble constant is H(sub zero) = 55 +/- 17 km/s/MPC.

Birkinshaw, M.↗

On the Correspondence between Mean Forecast Errors and Climate Errors in CMIP5 Models

The present study examines the correspondence between short- and long-term systematic errors in five atmospheric models by comparing the 16 five-day hindcast ensembles from the Transpose Atmospheric Model Intercomparison Project II (Transpose-AMIP II) for July–August 2009 (short term) to the climate simulations from phase 5 of the Coupled Model Intercomparison Project (CMIP5) and AMIP for the June–August mean conditions of the years of 1979–2008 (long term). Because the short-term hindcasts were conducted with identical climate models used in the CMIP5/AMIP simulations, one can diagnose over what time scale systematic errors in these climate simulations develop, thus yielding insights into their origin through a seamless modeling approach. The analysis suggests that most systematic errors of precipitation, clouds, and radiation processes in the long-term climate runs are present by day 5 in ensemble average hindcasts in all models. Errors typically saturate after few days of hindcasts with amplitudes comparable to the climate errors, and the impacts of initial conditions on the simulated ensemble mean errors are relatively small. This robust bias correspondence suggests that these systematic errors across different models likely are initiated by model parameterizations since the atmospheric large-scale states remain close to observations in the first 2–3 days. However, biases associated with model physics can have impacts on the large-scale states by day 5, such as zonal winds, 2-m temperature, and sea level pressure, and the analysis further indicates a good correspondence between short- and long-term biases for these large-scale states. Therefore, improving individual model parameterizations in the hindcast mode could lead to the improvement of most climate models in simulating their climate mean state and potentially their future projections.

54 ENVIRONMENTAL SCIENCES↗

THE Q/U IMAGING EXPERIMENT INSTRUMENT

The Q/U Imaging ExperimenT (QUIET) is designed to measure polarization in the cosmic microwave background, targeting the imprint of inflationary gravitational waves at large angular scales({approx}1 Degree-Sign ). Between 2008 October and 2010 December, two independent receiver arrays were deployed sequentially on a 1.4 m side-fed Dragonian telescope. The polarimeters that form the focal planes use a compact design based on high electron mobility transistors (HEMTs) that provides simultaneous measurements of the Stokes parameters Q, U, and I in a single module. The 17-element Q-band polarimeter array, with a central frequency of 43.1 GHz, has the best sensitivity (69 {mu}Ks{sup 1/2}) and the lowest instrumental systematic errors ever achieved in this band, contributing to the tensor-to-scalar ratio at r < 0.1. The 84-element W-band polarimeter array has a sensitivity of 87 {mu}Ks{sup 1/2} at a central frequency of 94.5 GHz. It has the lowest systematic errors to date, contributing at r < 0.01. The two arrays together cover multipoles in the range l {approx} 25-975. These are the largest HEMT-based arrays deployed to date. This article describes the design, calibration, performance, and sources of systematic error of the instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal measurement strategies for effective suppression of drift errors

Drifting of experimental setups with change in temperature or other environmental conditions is the limiting factor of many, if not all, precision measurements. The measurement error due to a drift is, in some sense, in-between random noise and systematic error. In the general case, the error contribution of a drift cannot be averaged out using a number of measurements identically carried out over a reasonable time. In contrast to systematic errors, drifts are usually not stable enough for a precise calibration. Here a rather general method for effective suppression of the spurious effects caused by slow drifts in a large variety of instruments and experimental setups is described. An analytical derivation of an identity, describing the optimal measurement strategies suitable for suppressing the contribution of a slow drift described with a certain order polynomial function, is presented. A recursion rule as well as a general mathematical proof of the identity is given. The effectiveness of the discussed method is illustrated with an application of the derived optimal scanning strategies to precise surface slope measurements with a surface profiler.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Algorithms for isolating worst case systematic data errors

Two separate algorithms are derived for testing filter sensitivity to systematic data errors. One algorithm provides the absolute minimum Euclidean norm data error for a given estimate component error. The second algorithm can be used to find the minimum norm data error which can be generated by restricted degree Legendre polynomials. A specific very long baseline interferometry (VLBI) baseline estimation is analyzed with the algorithm. It is found that the local vertical is the most sensitive component to error in the data space. The efficiency of a data error sequence linear in elevation angle is within 7% that of the absolute worst case sequence. Elevation angle dependent errors are explored and the special case of a mismodeled troposphere is treated.

Curkendall, D. W.↗

Positioning Accuracy in Stereotactic Radiotherapy Using a Mask System With Added Vacuum Mouth Piece and Stereoscopic X-Ray Positioning

Purpose: For cranial patients receiving stereotactic radiotherapy, we use the Exactrac stereoscopic X-ray system to optimize patient positioning. Patients are immobilized with the BrainLAB Mask System (BrainLAB, Feldkirchen, Germany). We have developed an adapter to this system that accommodates a vacuum mouth piece (VMP). Measurements with the Exactrac system have been performed to study the positioning accuracy after corrections with this system and to evaluate the accuracy of the VMP vs. the standard available upper jaw support (UJS). Methods and Materials: Positioning results were collected for 20 patients with the UJS and 20 patients with the VMP, before treatment (1,122 fractions) and after treatment (400 fractions). For all 6 degrees of freedom the average, the random error and systematic error were calculated. Results: The average vector length before and after correction with the Exactrac system was 2.1 {+-} 1.2 mm and 0.7 {+-} 0.6 mm respectively for UJS and 1.7 {+-} 0.7 mm and 0.4 {+-} 0.4 mm for VMP. Interfraction positioning for translations was greatly improved after correction with the Exactrac system (p < 0.0005) and is better with VMP than with UJS (p = 0.005). Outliers were greatly reduced. Interfraction rotations were significantly smaller for VMP. Intrafraction errors for vertical and longitudinal translations and for rotations were smaller for the VMP. Conclusions: Positioning correction using the Exactrac X-ray system greatly improves accuracy. Adding the VMP results in even better patient fixation and smaller rotations, making it a useful addition to the Mask System. Combined, this is a convenient and accurate alternative to invasive fixation methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Influence of sky radiance measurement errors on inversion-retrieved aerosol properties

Remote sensing of the atmospheric aerosol is a well-established technique that is currently used for routine monitoring of this atmospheric component, both from ground-based and satellite. The AERONET program, initiated in the 90's, is the most extended network and the data provided are currently used by a wide community of users for aerosol characterization, satellite and model validation and synergetic use with other instrumentation (lidar, in-situ, etc.). Aerosol properties are derived within the network from measurements made by ground-based Sun-sky scanning radiometers. Sky radiances are acquired in two geometries: almucantar and principal plane. Discrepancies in the products obtained following both geometries have been observed and the main aim of this work is to determine if they could be justified by measurement errors. Three systematic errors have been analyzed in order to quantify the effects on the inversion-derived aerosol properties: calibration, pointing accuracy and finite field of view. Simulations have shown that typical uncertainty in the analyzed quantities (5% in calibration, 0.2 Degree-Sign in pointing and 1.2 Degree-Sign field of view) yields to errors in the retrieved parameters that vary depending on the aerosol type and geometry. While calibration and pointing errors have relevant impact on the products, the finite field of view does not produce notable differences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗