Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Evaluation of EPIC Oxygen Bands Stability With Radiative Transfer Simulations Over the South Pole

The Earth Polychromatic Imaging Camera (EPIC) onboard the Deep Space Climate Observatory (DSCOVR) satellite orbiting the Sun at the Lagrange-1 point was launched without onboard calibration systems. Vicarious calibration is conducted for 8 of the 10 UV/VIS/NIR channels using other low earth orbiting satellite instruments, while its two O 2 bands (688 nm and 764nm) rely on indirect moon-view calibrations because the same narrow-band O 2 bands are not readily available from other in-flight instruments. This study compares EPIC measurements from the four O 2 bands aiming at examining sensor stability over a uniquely suited location, i.e., the permanently snow-covered South Pole. The study utilizes radiative transfer model simulations with in-situ atmospheric soundings taken at South Pole during months of December and January from 2015 to 2022. The absolute discrepancy between the model simulations and observations is less than 1.0% for the two reference bands, but 5.75% and 15.63% for the 688nm, and 764 nm absorption bands, respectively. The simulated A-band and B-band ratios are 16.09% and 4.74% higher than that from the observations. Various sensitivities are conducted to estimate possible contributions to the discrepancies from input atmospheric profiles, spectral surface albedos and surface BRDF. While none of the input uncertainties is likely to account for the large discrepancies in the oxygen absorption bands, a small shift in the instrument response function could be the main reason for these biases. On the other hand, the model simulations are able to capture systematic variations with observed angular measurements and explain the multi-year trends found in observed O 2 band ratios due to satellite orbit shifting. When model simulated contributions from the angle variations are deducted from the observed O 2 band ratios, the residual O 2 band ratios are found to be stable since 2015.

EPIC↗

Distribution System Model Calibration for GMLC 3.3.3 "Incipient Failure Identification for Common Grid Asset Classes" - Project Summary

Distribution system model calibration is a key enabling task for incipient failure identification within the distribution system. This report summarizes the work and publications by Sandia National Laboratories on the GMLC project titled “Incipient Failure Identification for Common Grid Asset Classes”. This project was a joint effort between Sandia National Laboratories, Lawrence Livermore National Laboratory, National Energy Technology Laboratory, and Oak Ridge National Laboratory. The included work covers distribution system topology identification, transformer groupings, phase identification, regulator and tap position estimation, and the open-source release and implementation of the developed algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution System Model Calibration Algorithms

SAND2021-15065 O This release contains Python code for two distribution system model calibration algorithms as well as some sample data and documentation for the algorithms and code. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Blakely, Logan↗

The tracking system analytic calibration activity for Mariner Mars 1971: Its function and scope

The functions of the Tracking System Analytic Calibration activity for Mariner Mars 1971 (MM'71), its objectives for this and future missions, and the support provided to the MM'71 Navigation Team during operations are described. Support functions encompass calibration of tracking data by estimating physical parameters whose uncertainties represent limitations to navigational accuracy, and detailed analysis of the tracking data to uncover and resolve any anomalies. Separate articles treat the activities and results of producing calibrations for the various error sources: Deep Space Station Locations, timing and polar motion, charged particles, and the troposphere. Two other articles are also included discussing the effects of the media error sources on orbit determination and the merits of the smoothing technique used for DRIVID.

Madrid, G. A.↗

Sensitivity of Satellite Ocean Color Data to System Vicarious Calibration of the Long Near Infrared Band

Satellite ocean color missions require accurate (< 1% uncertainties) system vicarious calibrations (SVC) in order to retrieve the relatively small remote sensing reflectance (Rrs, sr-1) from the at-sensor radiance. However, current atmospheric correction and SVC procedures do not include calibration of the “long” near infrared band (NIRL–869nm for MODIS), partially because earlier studies indicated that accuracy in the retrieved Rrsis insensitive to moderate changes in the NIRLvicarious gain (g). However, the sensitivity of ocean color data products to g(NIRL) has not been thoroughly examined. Here, we first derived 10 SVC ‘gain configurations’ (vicarious gains for all visible and NIR bands) for MODIS/Aqua using current operational NASA protocols, each time assuming a different g(869). From these, we derived a suite of ~1.4E6 unique gain configurations with g(869) ranging from 0.85 to 1.2. All MODIS/A data for 25locations within each of five ocean gyres were then processed using each of these gain configurations. Such time series show substantial variability inthe dominant Rrs(547) patterns in response to changes in g(869). Overall gyre mean Rrs(547) generally decreased with increasing g(869), while the standard deviations around those means show gyre-specific minima for 0.97 < g(869) < 1.02. Following these sensitivity analyses, we assess the potential to resolve g(869) using suchtime series, finding g(869) = 1.025 most closely comports with expectations. This approach is broadly applicable to other ocean color sensors, and highlights the importance of rigorous cross-sensor calibration of the NIRLbands, with implications on consistency of merged-sensor datasets.

vicarious calibration↗

Tracking system analytic calibration activities for the Mariner Mars 1971 mission

This report describes the functions of the Tracking System Analytic Calibration activity for Mariner Mars 1971 (MM'71), its objectives for this and future missions, and the support provided to the MM'71 Navigation Team during operations. The support functions encompass calibration of tracking data by estimating physical parameters whose uncertainties represent limitations to navigational accuracy, and detailed analysis of the tracking data to uncover and resolve any anomalies. Separate articles treat the activities and results of producing calibrations for the various error sources: Deep Space Station Locations, timing and polar motion, charged particles, and the troposphere. Two other articles are also included dis- - cussing the effects of the media error sources on orbit determination and the merits of the smoothing technique used for DRIVID.

Facilities↗

Test Plan for a Calibration Demonstration System for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission addresses the need to observe high-accuracy, long-term climate change trends and to use decadal change observations as the most critical method to determine the accuracy of climate change. One of the major objectives of CLARREO is to advance the accuracy of SI traceable absolute calibration at infrared and reflected solar wavelengths. This advance is required to reach the on-orbit absolute accuracy required to allow climate change observations to survive data gaps while remaining sufficiently accurate to observe climate change to within the uncertainty of the limit of natural variability. While these capabilities exist at NIST in the laboratory, there is a need to demonstrate that it can move successfully from NIST to NASA and/or instrument vendor capabilities for future spaceborne instruments. The current work describes the test plan for the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. The goal of the CDS is to allow the testing and evaluation of calibration approaches , alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The end result of efforts with the SOLARIS CDS will be an SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climate-quality data collections. The CLARREO mission addresses the need to observe high-accuracy, long-term climate change trends and advance the accuracy of SI traceable absolute calibration. The current work describes the test plan for the SOLARIS which is the calibration demonstration system for the reflected solar portion of CLARREO. SOLARIS provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The end result will be an SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climate-quality data collections.

Thome, Kurtis↗

The Bond Dissociation Energies of 1-Butene

The bond dissociation energies of 1-butene and several calibration systems are computed using the G2(MP2) approach. The agreement between the calibration systems and experiment is very good. The computed values for 1-butene are compared with calibration systems and the agreement between the computed results for 1-butene and the "rule of thumb" values from the smaller systems is remarkably good.

Bauschlicher, Charles W., Jr.↗

Tightly-coupled camera/LiDAR integration for point cloud generation from GNSS/INS-assisted UAV mapping systems

Unmanned aerial vehicles (UAVs) equipped with integrated global navigation satellite systems/inertial navigation systems (GNSS/INS) together with cameras and/or LiDAR sensors are being widely used for topographic mapping in a variety of applications such as precision agriculture, coastal monitoring, and archaeological documentation. Integration of image-based and LiDAR point clouds can provide a comprehensive 3D model of the area of interest. For such integration, ensuring a good alignment between data from the different sources is critical. Although many works have been conducted on this topic, there is still a need for a rigorous integration approach that minimizes the discrepancy between camera and LiDAR data caused by inaccurate system calibration parameters and/or trajectory artifacts. This study proposes an automated tightly-coupled camera/LiDAR integration workflow for GNSS/INS-assisted UAV systems. The proposed strategy is conducted in three main steps. First, an image-based point cloud is generated using a LiDAR/GNSS/INS-assisted structure from motion (SfM) strategy. Then, feature correspondences between image-based and LiDAR point clouds are automatically identified. Finally, an integrated-bundle adjustment procedure including image points, LiDAR raw measurements, and GNSS/INS information is conducted to minimize the discrepancy between point clouds from different sensors while estimating system calibration parameters and refining the trajectory information. The proposed SfM strategy and integration framework are evaluated using five datasets. The SfM results show that using LiDAR data can facilitate feature matching and further increase the number of reconstructed 3D points. The experimental results also illustrate that the developed automated camera/LiDAR integration strategy is capable of accurately estimating system calibration parameters to achieve good alignment among camera/LiDAR data from single/multiple systems. Finally, an absolute accuracy in the range of 3–5 cm is achieved for the image/LiDAR point clouds after the integration process.

42 ENGINEERING↗

Preliminary results from a subsonic high-angle-of-attack flush airdata sensing (HI-FADS) system - Design, calibration, algorithm development, and flight test evaluation

A nonintrusive high angle-of-attack flush airdata sensing (HI-FADS) system was installed and flight-tested on the F-18 high alpha research vehicle. This paper discusses the airdata algorithm development and composite results expressed as airdata parameter estimates and describes the HI-FADS system hardware, calibration techniques, and algorithm development. An independent empirical verification was performed over a large portion of the subsonic flight envelope. Test points were obtained for Mach numbers from 0.15 to 0.94 and angles of attack from -8.0 to 55.0 deg. Angles of sideslip ranged from -15.0 to 15.0 deg, and test altitudes ranged from 18,000 to 40,000 ft. The HI-FADS system gave excellent results over the entire subsonic Mach number range up to 55 deg angle of attack. The internal pneumatic frequency response of the system is accurate to beyond 10 Hz.

Whitmore, Stephen A.↗

In-Situ Load System for Calibrating and Validating Aerodynamic Properties of Scaled Aircraft in Ground-Based Aerospace Testing Applications

An In-Situ Load System for calibrating and validating aerodynamic properties of scaled aircraft in ground-based aerospace testing applications includes an assembly having upper and lower components that are pivotably interconnected. A test weight can be connected to the lower component to apply a known force to a force balance. The orientation of the force balance can be varied, and the measured forces from the force balance can be compared to applied loads at various orientations to thereby develop calibration factors.

Commo, Sean A.↗

Solar Energy Systems

Calibrated in kilowatt hours per square meter, the solar counter produced by Dodge Products, Inc. provides a numerical count of the solar energy that has accumulated on a surface. Solar energy sensing, measuring and recording devices in corporate solar cell technology developed by Lewis Research Center. Customers for their various devices include architects, engineers and others engaged in construction and operation of solar energy facilities; manufacturers of solar systems or solar related products, such as glare reducing windows; and solar energy planners in federal and state government agencies.

Source record↗

A multiple chamber, semicontinuous, crop carbon dioxide exchange system: design, calibration, and data interpretation

Long-term, whole crop CO2 exchange measurements can be used to study factors affecting crop growth. These factors include daily carbon gain, cumulative carbon gain, and carbon use efficiency, which cannot be determined from short-term measurements. We describe a system that measures semicontinuously crop CO2 exchange in 10 chambers over a period of weeks or months. Exchange of CO2 in every chamber can be measured at 5 min intervals. The system was designed to be placed inside a growth chamber, with additional environmental control provided by the individual gas exchange chambers. The system was calibrated by generating CO2 from NaHCO3 inside the chambers, which indicated that accuracy of the measurements was good (102% and 98% recovery for two separate photosynthesis systems). Since the systems measure net photosynthesis (P-net, positive) and dark respiration(R-dark, negative), the data can be used to estimate gross photosynthesis, daily carbon gain, cumulative carbon gain, and carbon use efficiency. Continuous whole-crop measurements are a valuable tool that complements leaf photosynthesis measurements. Multiple chambers allow for replication and comparison among several environmental or cultural treatments that may affect crop growth. Example data from a 2 week study with petunia (Petunia x hybrida Hort. Vilm.-Andr.) are presented to illustrate some of the capabilities of this system.

NASA Discipline Life Support Systems↗

Results from Source-Based and Detector-Based Calibrations of a CLARREO Calibration Demonstration System

The Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is formulated to determine long-term climate trends using SI-traceable measurements. The CLARREO mission will include instruments operating in the reflected solar (RS) wavelength region from 320 nm to 2300 nm. The Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO and facilitates testing and evaluation of calibration approaches. The basis of CLARREO and SOLARIS calibration is the Goddard Laser for Absolute Measurement of Response (GLAMR) that provides a radiance-based calibration at reflective solar wavelengths using continuously tunable lasers. SI-traceability is achieved via detector-based standards that, in GLAMRs case, are a set of NIST-calibrated transfer radiometers. A portable version of the SOLARIS, Suitcase SOLARIS is used to evaluate GLAMRs calibration accuracies. The calibration of Suitcase SOLARIS using GLAMR agrees with that obtained from source-based results of the Remote Sensing Group (RSG) at the University of Arizona to better than 5 (k2) in the 720-860 nm spectral range. The differences are within the uncertainties of the NIST-calibrated FEL lamp-based approach of RSG and give confidence that GLAMR is operating at 5 (k2) absolute uncertainties. Limitations of the Suitcase SOLARIS instrument also discussed and the next edition of the SOLARIS instrument (Suitcase SOLARIS- 2) is expected to provide an improved mechanism to further assess GLAMR and CLARREO calibration approaches. (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

Angal, Amit↗

Error Budget for a Calibration Demonstration System for the Reflected Solar Instrument for the Climate Absolute Radiance and Refractivity Observatory

A goal of the Climate Absolute Radiance and Refractivity Observatory (CLARREO) mission is to observe highaccuracy, long-term climate change trends over decadal time scales. The key to such a goal is to improving the accuracy of SI traceable absolute calibration across infrared and reflected solar wavelengths allowing climate change to be separated from the limit of natural variability. The advances required to reach on-orbit absolute accuracy to allow climate change observations to survive data gaps exist at NIST in the laboratory, but still need demonstration that the advances can move successfully from to NASA and/or instrument vendor capabilities for spaceborne instruments. The current work describes the radiometric calibration error budget for the Solar, Lunar for Absolute Reflectance Imaging Spectroradiometer (SOLARIS) which is the calibration demonstration system (CDS) for the reflected solar portion of CLARREO. The goal of the CDS is to allow the testing and evaluation of calibration approaches, alternate design and/or implementation approaches and components for the CLARREO mission. SOLARIS also provides a test-bed for detector technologies, non-linearity determination and uncertainties, and application of future technology developments and suggested spacecraft instrument design modifications. The resulting SI-traceable error budget for reflectance retrieval using solar irradiance as a reference and methods for laboratory-based, absolute calibration suitable for climatequality data collections is given. Key components in the error budget are geometry differences between the solar and earth views, knowledge of attenuator behavior when viewing the sun, and sensor behavior such as detector linearity and noise behavior. Methods for demonstrating this error budget are also presented.

radiometric calibration↗

Improved pressure measurement system for calibration of the NASA LeRC 10x10 supersonic wind tunnel

This paper discusses a method used to provide a significant improvement in the accuracy of the Electronically Scanned Pressure (ESP) Measurement System by means of a fully automatic floating pressure generating system for the ESP calibration and reference pressures. This system was used to obtain test section Mach number and flow angularity measurements over the full envelope of test conditions for the 10 x 10 Supersonic Wind Tunnel. The uncertainty analysis and actual test data demonstrated that, for most test conditions, this method could reduce errors to about one-third to one-half that obtained with the standard system.

Blumenthal, Philip Z.↗