Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system analysis module”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Supply and Demand Constraints on Future PV Power in the USA

An economic analysis with a defined uncertainty range is presented that considers whether the future deployment of utility-scale PV (UPV) systems in the USA will be limited by the supply of PV modules or by market demand for these systems. An analysis of global PV module manufacturing growth and the fraction of modules produced that will be available for installation in the USA gives a plausible range of cumulative capacity for the UPV segment of 50 - 170 GW in 2030 and 60 - 500 GW in 2040. A parallel analysis of the future demand for UPV systems in the USA indicates a plausible range for cumulative capacity of 80 - 230 GW in 2030 and 150 - 530 GW in 2040. The plausible ranges for supply and demand substantially overlap in both 2030 and 2040, suggesting that neither supply nor demand is more likely to limit PV deployment in the USA. Consequently, mechanisms for enabling growth in both supply and demand can benefit efforts intended to increase the deployment of PV in the USA.

14 SOLAR ENERGY↗

Supply and Demand Constraints on Future PV Power in the USA: Preprint

An economic analysis with a defined uncertainty range is presented that considers whether the future deployment of utility-scale PV (UPV) systems in the USA will be limited by the supply of PV modules or by market demand for these systems. An analysis of global PV module manufacturing growth and the fraction of modules produced that will be available for installation in the USA gives a plausible range of cumulative capacity for the UPV segment of 50 - 170 GW in 2030 and 60 - 500 GW in 2040. A parallel analysis of the future demand for UPV systems in the USA indicates a plausible range for cumulative capacity of 80 - 230 GW in 2030 and 150 - 530 GW in 2040. The plausible ranges for supply and demand substantially overlap in both 2030 and 2040, suggesting that neither supply nor demand is more likely to limit PV deployment in the USA. Consequently, mechanisms for enabling growth in both supply and demand can benefit efforts intended to increase the deployment of PV in the USA.

14 SOLAR ENERGY↗

An FDMA system concept for 30/20 GHz high capacity domestic satellite service

The paper summarizes a feasibility study of a multibeam FDMA satellite system operating in the 30/20 GHz band. The system must accommodate a very high volume of traffic within the restrictions of a 5 kW solar cell array and a 2.5 GHz bandwidth. Multibeam satellite operation reduces the DC power demand and allows reuse of the available bandwidth. Interferences among the beams are brought to acceptable levels by appropriate frequency assignments. A transponder design is presented; it is greatly simplified by the application of a regional concept. System analysis shows that MSK modulation is appropriate for a high-capacity system because it conserves the frequency spectrum. Rain attenuation, a serious problem in this frequency band, is combatted with sufficient power margins and with coding. Link budgets, cost analysis, and weight and power calculations are also discussed. A satellite-routed FDMA system compares favorably in performance and cost with a satellite-switched TDMA system.

Berk, G.↗

Thermal Analysis of the Advanced Modular Power Systems (AMPS) Power Electronic Modules

In an effort to transform future space power system architectures and operations, the Advanced Modular Power Systems (AMPS) project is currently developing an interface standard for power electronic modules to enable modular architectures for space power systems. Each architecture would consist of one or more modular electronic units (MEU) that would comprise of a tailored combination of modules. The standard currently comprises modules enabling switchgear, power conversion, and data interfacing. The objective of the AMPS project is to enable the modularity and interchangeability of different architectures using these standardized modules in hopes of reducing complexity and cost, increasing inherent redundancy and reliability, and minimizing power system redesign for future programs. A key enabler to these future modular architectures will be the thermal management system, which has to contend with acquiring heat from the electronics modules at the card level and then transporting that heat to the radiator of the larger system. The focus of this paper, therefore, will be the thermal design and analysis of multiple AMPS power electronics modules and the development of their thermal-vacuum test.

Modular Power Electronics↗

Revisiting the Effects of Photovoltaic Module Efficiency on Installed System Cost and Market Adoption

We conduct bottom-up analysis of how PV module efficiency could influence residential rooftop installed system costs, using models with improved representation of how soft costs and power electronics are affected by efficiency. We show that the amount of system installed cost savings resulting from high efficiency modules depends on whether or not the system is area-constrained, with much larger savings for the area-constrained case. We then estimate the fraction of physically area-constrained rooftops in the United States to be 61%, with variation between 20% to over 80% of rooftops depending on the state. We find that fraction of area-constrained systems could grow to over 88% by 2050 if building and transportation loads are electrified.

efficiency↗

Low-Speed Flight Dynamic Tests and Analysis of the Orion Crew Module Drogue Parachute System

A test of a dynamically scaled model of the NASA Orion Crew Module (CM) with drogue parachutes was conducted in the NASA-Langley 20-Foot Vertical Spin Tunnel. The primary test objective was to assess the ability of the Orion Crew Module drogue parachute system to adequately stabilize the CM and reduce angular rates at low subsonic Mach numbers. Two attachment locations were tested: the current design nominal and an alternate. Experimental results indicated that the alternate attachment location showed a somewhat greater tendency to attenuate initial roll rate and reduce roll rate oscillations than the nominal location. Comparison of the experimental data to a Program To Optimize Simulated Trajectories (POST II) simulation of the experiment yielded results for the nominal attachment point that indicate differences between the low-speed pitch and yaw damping derivatives in the aerodynamic database and the physical model. Comparisons for the alternate attachment location indicate that riser twist plays a significant role in determining roll rate attenuation characteristics. Reevaluating the impact of the alternate attachment points using a simulation modified to account for these results showed significantly reduced roll rate attenuation tendencies when compared to the original simulation. Based on this modified simulation the alternate attachment point does not appear to offer a significant increase in allowable roll rate over the nominal configuration.

Hahne, David E.↗

WeaselBoard :

Critical infrastructures, such as electrical power plants and oil refineries, rely on programmable logic controllers (PLCs) to control essential processes. State of the art security cannot detect attacks on PLCs at the hardware or firmware level. This renders critical infrastructure control systems vulnerable to costly and dangerous attacks. WeaselBoard is a PLC backplane analysis system that connects directly to the PLC backplane to capture backplane communications between modules. WeaselBoard forwards inter-module traffic to an external analysis system that detects changes to process control settings, sensor values, module configuration information, firmware updates, and process control program (logic) updates. WeaselBoard provides zero-day exploit detection for PLCs by detecting changes in the PLC and the process. This approach to PLC monitoring is protected under U.S. Patent Application 13/947,887.

Mulder, John C.↗

Quantifying spectral albedo effects on bifacial photovoltaic module measurements and system model predictions

We provide a comprehensive analysis of the effect of spectral albedo on photovoltaic (PV) module measurements and system model predictions. We demonstrate how to account for albedo in indoor bifacial device measurements by adjusting the applied irradiance using the scaled rear irradiance method, exemplified on fabricated silicon heterojunction (SHJ) modules. System model performance is studied using a detailed 3D finite-element model, DUET, for fixed-tilt and horizontal single-axis tracked (SAT) arrays between 15 and 75°N. Spectral effects cause variations in measured SHJ module short-circuit current up to 2% and efficiency variation up to 0.3% abs. We further demonstrate that rear-side spectral mismatch factors (SMMs) resulting from including or omitting spectral albedo in PV system modeling vary between ±13%, while total (front+rear) SMMs vary up to 3%, depending on the deployment configuration and latitude. SAT array SMMs are weakly correlated with latitude, while fixed-tilt array SMMs increase with latitude, driven by an increasing proportion of ground-reflected light on the front-side of modules. Ground-reflections can constitute between 2% and 32% of total incident module irradiance, with notably high (>10%) contributions for fixed-tilt arrays at high latitude. Effects of spectral albedo are most significant for: (1) fixed-tilt deployments at high latitudes, (2) wide bandgap technologies such as perovskite and cadmium telluride cells, (3) albedos which vary steeply over the technology's absorption range, and (4) high albedo ground covers. Overall, we demonstrate that omitting spectral albedo effects can result in PV measurement and system-level modeling uncertainties on the order of several percent in these cases.

14 SOLAR ENERGY↗

Approximating Fluid Flow from Ambient to Very Low Pressures: Modeling ISS Experiments that Vent to Vacuum

Two ISS (International Space Station) experiment payloads will vent a volume of gas overboard via either the ISS Vacuum Exhaust System or the Vacuum Resource System. A system of ducts, valves and sensors, under design, will connect the experiments to the ISS systems. The following tasks are required: Create an analysis tool that will verify the rack vacuum system design with respect to design requirements, more specifically approximate pressure at given locations within the vacuum systems; Determine the vent duration required to achieve desired pressure within the experiment modules; Update the analysis as systems and operations definitions mature.

Minor, Robert↗

Counter Trafficking System Development "Analysis Training Program"

This document will detail the training curriculum for the Counter-Trafficking System Development (CTSD) Analysis Modules and Lesson Plans are derived from the United States Military, Department of Energy doctrine and Lawrence Livermore National Laboratory (LLNL), Global Security (GS) S Program.

99 GENERAL AND MISCELLANEOUS↗

Line group techniques in description of the structural phase transitions in some superconductors

The main features of the theory of line groups, and their irreducible representations are briefly discussed, as well as the most important applications of them. A new approach in the general symmetry analysis of the modulated systems is presented. It is shown, that the line group formalism could be a very effective tool in the examination of the structural phase transitions in High Temperature SUperconductors. As an example, the material YBa2Cu3O(7-x) is discussed briefly.

Meszaros, CS.↗

PV High Wind User Test Facility

The creation of a PV high wind test facility at the NREL Flatirons Campus that will enable private and public research efforts aimed at storm hardening PV systems. The facility will be instrumented to monitor effects of high wind conditions on modules and other array components. These in-field tests will coordinate with flow models, wind tunnel testing, validation of PV aeroelastic design codes, and post-testing module and system component analysis.

14 SOLAR ENERGY↗

Updates to the Instant Online PV LCOE Calculator Tool

Levelized cost of energy (LCOE) is an important metric for techno-economic analysis of PV modules, systems, and performance. An NREL team within DuraMAT has developed a simplified PV-specific LCOE calculator as an alternative to the NREL System Advisor Model (SAM) for applications that do not have the degree of detail required by SAM. This webinar will review recent data and new features that have been added to the simplified calculator this year, including breakeven buttons, commercial system options, and inverter loading ratios. It will also review the structure of the source code on GitHub, how to edit a local version of the calculator, and walk through some example use cases for the calculator.

calculator↗

Role of IAC in large space systems thermal analysis

Computer analysis programs to evaluate critical coupling effects that can significantly influence spacecraft system performance are described. These coupling effects arise from the varied parameters of the spacecraft systems, environments, and forcing functions associated with disciplines such as thermal, structures, and controls. Adverse effects can be expected to significantly impact system design aspects such as structural integrity, controllability, and mission performance. One such needed design analysis capability is a software system that can integrate individual discipline computer codes into a highly user-oriented/interactive-graphics-based analysis capability. The integrated analysis capability (IAC) system can be viewed as: a core framework system which serves as an integrating base whereby users can readily add desired analysis modules and as a self-contained interdisciplinary system analysis capability having a specific set of fully integrated multidisciplinary analysis programs that deal with the coupling of thermal, structures, controls, antenna radiation performance, and instrument optical performance disciplines.

Jones, G. K.↗

Error Analysis of the Shuttle Reaction Control System Propellant Gaging Module

An investigation of the Shuttle Reaction Control System (RCS) propellant gaging module has revealed that the gaging errors due to the combined effects of random instrumentation measurement errors and propellant loading uncertainties are non-linear over the range of the propellant quantity gage (0-100%), with the largest error occurring at the zero point. When the RCS propellant tanks are filled to contain 100% of the maximum usable propellant, the largest gaging error was determined to be 3.9% for the fuel and 5.4% for the oxidizer. When the RCS propellant tanks initially contain 50% of the maximum usable propellant, the largest gaging error increases to 4.0% for the fuel and 5.6% for the oxidizer.

Duhon, D. D.↗