Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Characterization of Potential Micrometeorites by Synchrotron Analysis

Micrometeorites (MMs) are small particles that account for most of the extraterrestrial material deposited on Earth. Synchrotron X-ray fluorescence and diffraction allowed for chemical and mineral characterization to distinguish MM from atmospheric particulate. The relative components of iron, nickel, and other elements were considered in the identification of ferrous MM while high amounts of titanium were considered an indication that the particles were of atmospheric origin. Out of 100 samples collected by high school students and teachers, eight were taken to a synchrotron for analysis. Of those eight, three exhibited extraterrestrial compositions. X-ray absorption near-edge structure analysis revealed that the same three samples contained sulfide, the main sulfur form constituent in MM. X-ray microdiffraction analysis showed the presence of the minerals pentlandite and forsterite. Collectively, these results support the extraterrestrial nature of the three particles.

58 GEOSCIENCES↗

Topaz, a Potential Volatile-Carrier in Cold Subduction Zone: Constraint from Synchrotron X-ray Diffraction and Raman Spectroscopy at High Temperature and High Pressure

The equation of state and stability of topaz at high-pressure/high-temperature conditions have been investigated by in situ synchrotron X-ray diffraction (XRD) and Raman spectroscopy in this study. No phase transition occurs on topaz over the experimental pressure–temperature ($P-T$) range. The pressure–volume data were fitted by the third-order Birch–Murnaghan equation of state (EoS) with the zero-pressure unit–cell volume V 0 = 343.86 (9) Å 3 , the zero-pressure bulk modulus K 0 = 172 (3) GPa, and its pressure derivative K’ 0 = 1.3 (4), while the obtained K 0 = 155 (2) GPa when fixed K’ 0 = 4. In the pressure range of 0–24.4 GPa, the vibration modes of in-plane bending OH-groups for topaz show non-linear changes with the increase in pressure, while the other vibration modes show linear changes. Moreover, the temperature–volume data were fitted by Fei’s thermal equation with the thermal expansion coefficient α 300 = 1.9 (1) × 10 –5 K –1 at 300 K. Finally, the $P-T$ stability of topaz was studied by a synchrotron-based single-crystal XRD at simultaneously high $P-T$ conditions up to ~10.9 GPa and 700 K, which shows that topaz may maintain a metastable state at depths above 370 km in the upper mantle along the coldest subducting slab geotherm. Thus, topaz may be a potential volatile-carrier in the cold subduction zone. It can carry hydrogen and fluorine elements into the deep upper mantle and further affect the geochemical behavior of the upper mantle.

36 MATERIALS SCIENCE↗

Crystal Structure of Moganite and Its Anisotropic Atomic Displacement Parameters Determined by Synchrotron X-ray Diffraction and X-ray/Neutron Pair Distribution Function Analyses

The crystal structure of moganite from the Mogán formation on Gran Canaria has been re-investigated using high-resolution synchrotron X-ray diffraction (XRD) and X-ray/neutron pair distribution function (PDF) analyses. Our study for the first time reports the anisotropic atomic displacement parameters (ADPs) of a natural moganite. Rietveld analysis of synchrotron XRD data determined the crystal structure of moganite with the space group I2/a. The refined unit-cell parameters are a = 8.7363(8), b = 4.8688(5), c = 10.7203(9) Å, and β = 90.212(4)°. The ADPs of Si and O in moganite were obtained from X-ray and neutron PDF analyses. The shapes and orientations of the anisotropic ellipsoids determined from X-ray and neutron measurements are similar. The anisotropic ellipsoids for O extend along planes perpendicular to the Si-Si axis of corner-sharing SiO4 tetrahedra, suggesting precession-like movement. Neutron PDF result confirms the occurrence of OH over some of the tetrahedral sites. We postulate that moganite nanomineral is stable with respect to quartz in hypersaline water. The ADPs of moganite show a similar trend as those of quartz determined by single-crystal XRD. In short, the combined methods can provide high-quality structural parameters of moganite nanomineral, including its ADPs and extra OH position at the surface. This approach can be used as an alternative means for solving the structures of crystals that are not large enough for single-crystal XRD measurements, such as fine-grained and nanocrystalline minerals formed in various geological environments.

58 GEOSCIENCES↗

Synchrotron-driven Instabilities in Relativistic Plasmas of Arbitrary Opacity

Recent work has shown that synchrotron emission from relativistic plasmas leads the electron distribution to form an anisotropic ring in momentum space, which can be unstable to both kinetic and hydrodynamic instabilities. Fundamental to these works was the assumption that the plasma was optically thin, allowing all emitted radiation to escape. Here, we examine the behavior of these instabilities as the plasma becomes more optically thick. To do this, we extend a recently developed Fokker–Planck operator for synchrotron emission and absorption in mildly relativistic plasmas to ultrarelativistic plasmas. For a given set of plasma parameters, photons emitted by higher-energy electrons tend to be higher frequency, and thus more easily escape the plasma. As a result, the ratio of the photon emission rate (radiative drag) to absorption rate (radiative diffusion) for a given electron is extremely energy dependent. Given this behavior, we determine the critical parameters that control the opacity, and show how the plasma gradually transitions to become more isotropic and stable at higher opacity.

79 ASTRONOMY AND ASTROPHYSICS↗

Using Jupiter's Synchrotron Radiation as a Probe into Jupiter's Inner Radiation Belts

The Jovian decimetric emission is caused by the combined emission of synchrotron radiation originating from the relativistic electrons trapped in Jupiter's 'Van Allen radiation belts' and thermal emission from the planet's atmosphere. Synchrotron radiation characteristics and variations (which provides insight into the physical properties of Jupiter's inner radiation belts) will be amplified and discussed.

jupiter synchrotron radiation jovian inner radiati↗

(abstract) Short Time Period Variations in Jupiter's Synchrotron Radiation

The long term time variability of Jupiter's synchrotron radiation on yearly time scales has been established for some time. For many years, theorists have speculated about the effects variations in the solar wind, solar flux, Io, the Io torus, and Jupiter's magnetic field have on the ultra-relativistic electron population responsible for the emission. Early observational results suggested the additional possibility of a short term time variability, on timescales of days to weeks. In 1989 a program designed to investigate the existence of short term time variability using the 85 foot Hat Creek radio telescope operating at 1400 MHz was initiated. The availability of a dedicated telescope provided the opportunity, for the first time, to obtain numerous observations over the full Jupiter rotation period. These and future observations will enable two important studies, characterization and confirmation of possible short term variations, and the investigation of the stability of Jupiter's synchrotron emission beaming curve. Analysis of Hat Creek observations and early results from the Maryland Point Naval research Laboratory will be presented.

telescope magnetic field↗

Changes in Jupiter's 13-cm Synchrotron Radio Emission Following the Impact of Comet Shoemaker-Levy-9

Results of an observing program to monitor the synchrotron radio emission from Jupiter's inner radiation belts before, during and after the impact of Comet SL-9 are reported. The observations were made at 2295 MHz as part of the NASA-JPL Jupiter Patrol, a long-term radio astronomy monitoring program begun in 1971. The data indicate that the intensity of the synchrotron emission at 13 cm wavelength increased by 27 percent within a few days after the comet impacts; the longitudinal beaming curve was distorted during the week of impacts; the magnetic latitude beaming curves flattened after the week of impacts suggesting an increase in the emission at higher magnetic latitudes; and the decay of the enhanced emission is consistent with an exponential with a time constant of ~125 days. The reported changes following the SL-9 impact are unprecedented in the 23-year history of the Jupiter Patrol.

Synchrotron↗

Image processing workflow yielding high contrast synchrotron nanoscale computed tomography data from Ni-YSZ electrodes

The operating lifetime of Ni-YSZ fuel electrodes used in solid oxide electrolysis cells and fuel cells (SOECs and SOFCs) is limited by Ni redistribution, one of the primary degradation mechanisms that must be overcome to extend the longevity and maximize the performance of SOECs and SOFCs. To achieve this, 3D microstructural data is needed to relate both initial performance and performance loss over time to microstructural properties and their evolution throughout operation under various conditions. However, 3D microstructure data remains relatively scarce within the literature due to multiple challenges in acquiring and analyzing such data reliably. This work presents a workflow for acquiring and processing synchrotron X-ray nanoscale computed tomography (nano-CT) data from Ni-YSZ electrodes. Parameters for each step in the nano-CT workflow are described up to the final result (a 3D reconstruction), with particular emphasis on image alignment using freely available software. Following the results of a parametric sweep of the image alignment step, high contrast, low signal-to-noise 3D nano-CT data is obtained with relatively short compute times. While the exact methods best suited to samples with different microstructural qualities, or similar Ni-YSZ nano-CT data obtained from other sources may deviate from the solution found herein, this work also generalizes the decision points and evaluation of each step to provide a starting point to adapt this workflow to other datasets.

08 HYDROGEN↗

Synchrotron X‐Ray‐Driven Nitrogen Reduction on an AgCu Thin Film

Abstract Nitrogen (N 2 ) is an essential element for life, but kinetically stable N 2 in the atmosphere needs to be reduced to biologically available forms as a nutrient for organisms. Abiotic nitrogen fixation is critical to the origin of life on the early Earth, which is due to lightning or mineral‐based reduction. Here, synchrotron X‐ray‐induced silver nitrate formation on a silver copper (AgCu) thin‐film is reported. Time‐resolved X‐ray diffraction measurements show that under intense X‐ray exposure, initially formed silver oxides (AgOx) are quickly converted to silver nitrate (AgNO 3 ). Interestingly, AgNO 3 is first formed in its high‐temperature phase with a space group of R3cH , which gradually transforms to the room temperature phase with a space group of Pbca under continuous X‐ray irradiation. The result not only provides a new clue about the abiotic nitrogen reduction prior to life but also demonstrates a novel strategy of materials synthesis using synchrotron X‐rays.

Hui, Jian↗

Synchrotron CT imaging of lattice structures with engineered defects

Understanding mechanical failure, crack propagation, and compressive behavior at the micrometer scale is essential for tailoring material properties for structural performance in cellular materials. Typically, modeling of traditional polymer foam materials is clouded by the lack of control in material morphology and its inherent stochastic structure. Additive manufacturing with sub-micrometer resolution provides a direct path for experimenters to specifically tailor structures needed by modelers to explicitly probe mechanical performance. Using laboratory-based 3D X-ray computed tomographic imaging (CT), the examination of deformation and damage provides a critical path to understand how these soft materials behave. Additionally, synchrotron CT yields realistic information at higher strain rates to directly validate the robustness of our finite element modeling. For this study, nanolithographic printing was employed to generate a series of engineered lattices with increasing levels of defects through the random removal of ligaments. These structures were mechanically tested and imaged with laboratory-based microCT. Additionally, synchrotron experiments were conducted in which the structures were imaged in 3D at 14 Hz during compression at a 0.4 s –1 strain rate. These 3D images show the changes in the structure as the ligaments bend, buckle and fracture in real time. This technique provides a robust framework for developing our methodologies and future exploration of engineered structures.

36 MATERIALS SCIENCE↗

Effect of oxidation on the release of multiple metals from industrially polluted sediments and synchrotron-based evidence of Cu–S dynamic association

Disposal operations for industrially polluted sediments are usually accompanied by disturbance and resuspension, which can induce metal remobilization and secondary pollution. Evaluating the risk of metal release under various redox conditions is fundamental for predicting contaminant mobilization and guiding remediation measures. An abandoned oxidation pond, Yanjia Lake, China, was selected as a typical industrially polluted site. Re-suspension experiments were carried out by mixing polluted sediments with lake water under oxic or anoxic conditions, then investigating the effect of oxidation conditions on the release of multiple metals. Metal concentrations and aqueous chemistry in the overlying water were monitored. Synchrotron-based methods, including X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), were used to characterize oxidation states and coordination conditions of metals in sediments. The release of metals, including Cr, Co, Ni, Cu, Zn, Se, Mo, Sn, Cd, and Pb, was enhanced under oxic vs. anoxic conditions. The XANES analysis revealed that elevated Cr and Zn concentrations under oxic conditions likely resulted from the oxidation of Cr(III) and oxidizing dissolution of ZnS, respectively. K-edge Cu XANES, S XANES, and Cu EXAFS analyses reconstructed the Cu–S association, indicating that S-related oxidation promoted Cu release and Cu–O partly replaced Cu–S in the sediment after a 7-day oxic treatment. The release of most metals was promoted under oxic conditions, resulting from the oxidation of sulfides and metals as indicated by aqueous and synchrotron-based evidence. The risk of secondary pollution is greatly enhanced under oxic conditions, which suggests that measures should be taken to minimize the redox disturbance during sediment remediation. This information can guide the management of sediments in Yanjia Lake and other contaminated sites with similar properties.

54 ENVIRONMENTAL SCIENCES↗

Real-time damage characterization for GFRCs using high-speed synchrotron X-ray phase contrast imaging

Here, we report the application of high-speed synchrotron X-ray phase contrast imaging (PCI) in real-time damage characterization for glass fiber reinforced composites (GFRCs) subjected to dynamic loading. Dynamic single-edge notched bending (DSENB) experiments on pre-notched S-2 GFRCs were performed on a modified Kolsky compression bar. During loading, the synchrotron X-ray beam penetrated through the composite specimen from the side to detect damage evolution inside the material. Entire dynamic events were recorded by a high-speed camera as image sequences.0° and 90° unidirectional and cross-ply composites were investigated. An optical imaging technique was also employed to capture similar dynamic events in comparison with the radiographic imaging. It is demonstrated that high-speed X-ray PCI had sufficient phase contrast to characterize a crack initiation at a 20-μm spatial resolution within 920 ns and track the crack geometry during propagation, thereby providing reliable data to quantify the dynamic damage resistance of GFRCs. Furthermore, being capable of recognizing microscopic damage-related features at a sub-10-μm resolution, high-speed X-ray PCI provided fundamental material failure mechanisms to reveal the essential of macroscale structural failure of composites. It can also track the damage evolution inside and between individual plies of laminated composites. However, current high-speed X-ray PCI technique only supports in-situ observation and the high timing and spatial resolutions are limited within a field of view of ~2.5 mm in square, preventing its application in the three-dimensional and larger-area damage detection for GFRC structures.

42 ENGINEERING↗

Imaging Zn and Ni distributions in leaves of different ages of the hyperaccumulator Noccaea caerulescens by synchrotron-based X-ray fluorescence

Mapping of leaves of hyperaccumulators can provide insights into the mechanisms these species utilize to accumulate high metal concentrations. We used synchrotron-based X-ray fluorescence (SXRF) to perform Zn and Ni imaging in leaves of different ages of Noccaea caerulescens. A mature leaf of the related non-hyperaccumulator Thlaspi arvense was also imaged. The concentrations of Zn, Ni, Co, and Cr in N. caerulescens grown on an ultramafic soil were 9-, 10-, 12-, and 3-fold higher than T. arvense. N. caerulescens showed an exceptional ability to accumulate Zn from the soil, posing a bioconcentration factor of 6.7. T. arvense had Zn and Ni distributed uniformly in the leaf blade with doubling fluorescence counts in the tip and margins, suggesting a strategy to excrete metals and avoid toxicity. On the other hand, N. caerulescens displayed distinctly different Zn and Ni accumulation patterns, regardless of the age or metal concentration in the leaves. Zinc was mainly distributed in the cells surrounding the central and secondary veins. Nickel accumulated in the margins and tips of the leaf blade. Finally, given the time required to image large leaves in synchrotron facilities, small leaves can be used to represent the leaf distribution of Zn and Ni in N. caerulescens.

36 MATERIALS SCIENCE↗

Synchrotron X-ray based particle image velocimetry to measure multiphase streamflow and densitometry

Synchrotron-based radiation techniques are increasingly used in the field of flow condition measurements. As a complicated multiphase flow, cavitation has been investigated in a wide variety of industrial fields, to prevent damages on spillways at large dams or intensify the bacteria eradication rate during water treatments. To control the detrimental effects of cavitating flows, the dynamics of and mechanisms affecting cavitation development shall be visualized and identified in real-time. Due to the large reflection and scattering effects of multiphase flow, standard visible-light imaging technologies cannot penetrate vapor bubbles and provide extremely limited information. In this study, the synchrotron source emitted high-flux X-ray pulses are used to capture flow motion and visualize internal structures with sufficiently high spatial and temporal resolutions. The image processing procedures on raw x-ray images are developed using 2D Fourier transform (FT) and wavelet transform (WT) to implement the contrast enhancement and de-noising. Through the edge detection algorithm, tracking either seeded particles or phase interfaces inside the opaque multiphase flow can be achieved to perform the particle image velocimetry. Further, with decomposing particle-only and particle-eliminated subplots from the X-ray phase-contrast image, the time-resolved velocity and void fraction fields are obtained simultaneously, paving a way for further flow condition analysis such as densitometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Small-wedge synchrotron and serial XFEL datasets for Cysteinyl leukotriene GPCRs

Structural studies of challenging targets such as G protein-coupled receptors (GPCRs) have accelerated during the last several years due to the development of new approaches, including small-wedge and serial crystallography. Here, we describe the deposition of seven datasets consisting of X-ray diffraction images acquired from lipidic cubic phase (LCP) grown microcrystals of two human GPCRs, Cysteinyl leukotriene receptors 1 and 2 (CysLT 1 R and CysLT 2 R), in complex with various antagonists. Five datasets were collected using small-wedge synchrotron crystallography (SWSX) at the European Synchrotron Radiation Facility with multiple crystals under cryo-conditions. Two datasets were collected using X-ray free electron laser (XFEL) serial femtosecond crystallography (SFX) at the Linac Coherent Light Source, with microcrystals delivered at room temperature into the beam within LCP matrix by a viscous media microextrusion injector. All seven datasets have been deposited in the open-access databases Zenodo and CXIDB. Here, we describe sample preparation and annotate crystallization conditions for each partial and full datasets. We also document full processing pipelines and provide wrapper scripts for SWSX and SFX data processing. A Correction to this paper has been published: https://doi.org/10.1038/s41597-020-00759-w

97 MATHEMATICS AND COMPUTING↗

In situ synchrotron diffraction and modeling of non-equilibrium solidification of a MnFeCoNiCu alloy

The solidification mechanism and segregation behavior of laser-melted Mn 35 Fe 5 Co 20 Ni 20 Cu 20 was firstly investigated via in situ synchrotron x-ray diffraction at millisecond temporal resolution. The transient composition evolution of the random solid solution during sequential solidification of dendritic and interdendritic regions complicates the analysis of synchrotron diffraction data via any single conventional tool, such as Rietveld refinement. Therefore, a novel approach combining a hard-sphere approximation model, thermodynamic simulation, thermal expansion measurement and microstructural characterization was developed to assist in a fundamental understanding of the evolution of local composition, lattice parameter, and dendrite volume fraction corresponding to the diffraction data. This methodology yields self-consistent results across different methods. Via this approach, four distinct stages were identified, including: (I) FCC dendrite solidification, (II) solidification of FCC interdendritic region, (III) solid-state interdiffusion and (IV) final cooling with marginal diffusion. It was found out that in Stage I, Cu and Mn were rejected into liquid as Mn 35 Fe 5 Co 20 Ni 20 Cu 20 solidified dendritically. During Stage II, the lattice parameter disparity between dendrite and interdendritic region escalated as Cu and Mn continued segregating into the interdendritic region. After complete solidification, during Stage III, the lattice parameter disparity gradually decreases, demonstrating a degree of composition homogenization. The volume fraction of dendrites slightly grew from 58.3 to 65.5%, based on the evolving composition profile across a dendrite/interdendritic interface in diffusion calculations. Postmortem metallography further confirmed that dendrites have a volume fraction of 64.7 ± 5.3% in the final microstructure.

36 MATERIALS SCIENCE↗