Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sweep testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

The Fuel Accident Condition Simulator (FACS) furnace system for high temperature performance testing of VHTR fuel

The AGR-1 irradiation of TRISO-coated particle fuel specimens was recently completed and represents the most successful such irradiation in US history, reaching peak burnups of greater than 19% FIMA with zero failures out of 300,000 particles. An extensive post-irradiation examination (PIE) campaign will be conducted on the AGR-1 fuel in order to characterize the irradiated fuel properties, assess the in-pile fuel performance in terms of coating integrity and fission metals release, and determine the fission product retention behavior during high temperature safety testing. A new furnace system has been designed, built, and tested to perform high temperature accident tests. The Fuel Accident Condition Simulator furnace system is designed to heat fuel specimens at temperatures up to 2000 degrees C in helium while monitoring the release of volatile fission metals (e.g. Cs, Ag, Sr, and Eu), iodine, and fission gases (Kr, Xe). Fission gases released from the fuel to the sweep gas are monitored in real time using dual cryogenic traps fitted with high purity germanium detectors. Condensable fission products are collected on a plate attached to a water-cooled cold finger that can be exchanged periodically without interrupting the test. Analysis of fission products on the condensation plates involves dry gamma counting followed by chemical analysis of selected isotopes. This paper will describe design and operational details of the Fuel Accident Condition Simulator furnace system and the associated fission gas monitoring system, as well as preliminary system calibration results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Broadband cross polarization for ultra-wideline magic-angle spinning NMR

Over the past decade, there has been a sustained interest in using frequency-swept (FS) pulses for the efficient acquisition of wideline and ultra-wideline (UW) NMR powder patterns. Such experiments are typically conducted under static conditions, employing both direct- and indirect-excitation methods (i.e., WCPMG and BRAIN-CP/WCPMG, respectively). Recently, Koppe et al. demonstrated that the WCPMG pulse sequence can be used to efficiently acquire wideline and UW NMR spectra with spinning sideband (SSB) manifolds under magic-angle spinning (MAS) conditions, capitalizing on the increased signal-to-noise ratios (SNR) afforded by MAS. To date, there have been only a few instances of broadband cross-polarization (CP) experiments using FS pulses under MAS conditions and no applications to systems exhibiting wideline and/or ultra-wideline powder patterns, despite the clear advantages these experiments could offer. Herein, we demonstrate that FS pulses selectively applied to a single sideband of the S spin can be used for efficient 1 H-S polarization transfer to S = 1/2 nuclides with large anisotropic chemical shift interactions at slow to moderate MAS rates. The Hartmann–Hahn matching conditions in BRAIN-CP/WCPMG-MAS experiments bear similarity to those of standard CP sequences, yet operate over UW frequency ranges and only require low-amplitude RF pulses on the S channel. Crucial to the success of the BRAIN-CP/WCPMG-MAS experiment is careful calibration of the RF amplitude, transmitter offset, and effective frequency sweep of the FS pulse applied to the S spins at a given MAS rate. Thus, by means of numerical simulations and experimental testing, we provide recommendations for the parameterization and setup of BRAIN-CP/WCPMG-MAS experiments for their most efficient use. Results showcasing the capability of the BRAIN-CP/WCPMG-MAS pulse sequence are presented, including applications to 119 Sn, 195 Pt, and 103 Rh NMR.

Kimball, James J. [Florida State University, Talla↗

Upgrade of Core Conduction Cooldown Test Facility Control System

The CCCTF was designed and installed at ORNL in the 1990s for high-temperature gas-cooled reactor accident simulation. It is located within a modular hot cell housed in the IFEL facility. In 2008 and 2009, modifications were made to the CCCTF in preparation for AGR safety testing. A new airlock was designed and installed to better support periodic exchange of the fission product deposition cups while maintaining the fuel at safety test temperature, and modifications were made to add routines to the existing user interface software for computer-controlled automation of the He sweep gas flow and liquid nitrogen supply to the 85Kr cold traps. However, the furnace control hardware and software remained essentially unchanged. At the conclusion of the AGR-1 and AGR-2 PIE campaigns, continued use of the CCCTF was in question because of the gradual obsolescence of the hardware and software used to control the furnace and ancillary systems that make up the CCCTF. Therefore, an effort was undertaken to replace all the obsolete components with new hardware and update the software to increase system reliability and ensure this capability’s maintenance for future research and fuel qualification efforts. The modifications included creating a new National Instruments (NI) LabVIEW-based control system with a graphical user interface (GUI).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-2 Data Qualification Report for ATR Cycle 154B

This report provides the data qualification status of Advanced Gas Reactor-2 (AGR-2) fuel irradiation experimental data from Advanced Test Reactor (ATR) Cycle 154B as recorded in the Nuclear Data Management and Analysis System (NDMAS). This is the last cycle of AGR-2 irradiation, as the test train was pulled from the ATR core during the outage portion of ATR Cycle 155A. The AGR-2 data streams addressed in this report include thermocouple (TC) temperatures, sweep gas data (flow rates including new Fission Product Monitoring (FPM) downstream flows from Fission Product Monitoring System (FPMS) detectors, pressure, and moisture content), and FPMS data (release rates and release-to-birth rate ratios [R/Bs]) for each of the six capsules in the AGR-2 experiment. The final data qualification status for these data streams is determined by a Data Review Committee (DRC) comprised of AGR technical leads, Sitewide Quality Assurance (QA), and NDMAS analysts. The Data Review Committee reviewed the data acquisition process, considered whether the data met the requirements for data collection as specified in QA-approved Very High Temperature Reactor (VHTR) data collection plans, examined the results of NDMAS data testing and statistical analyses, and confirmed the qualification status of the data as given in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Volumetric efficiency and pressure pulsations of a triplex reciprocating supercritical CO 2 pump

A reciprocating triplex pump has been integrated into a closed-loop supercritical carbon dioxide test facility. The pump is designed to compress liquid or supercritical carbon dioxide and has a maximum volumetric flow rate of 51 L/min. A sweep across the pump’s speed range of 100–1000 rev/min was performed with inlet conditions between 60 and 160 bar. The volumetric efficiency was found to increase as pump speed increased from 10 to 40 % before it plateaued at higher pump speeds. The mechanical efficiency increased linearly with pump speed and was not affected by system pressure. Pressure pulsations caused by the plungers and valves were also measured at each speed. Additionally, a 35-liter buffer volume, connected near the pump’s discharge was isolated at each speed to determine its effectiveness as a pulsation dampener. Overall the reciprocating pump was shown to perform exceptionally with liquid or supercritical inlet conditions applicable to many supercritical fluid applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In service inspection and repair of sodium cooled ASTRID prototype

In the frame of the large R and D work which is performed for the future ASTRID sodium cooled prototype, In Service Inspection and Repair (ISI and R) has been identified as a major issue to be taken into account in order to enlarge the plant safety, to consolidate its availability and to protect the associated investment. After the first part of pre-conceptual design phase (2008-2012), the running second part of pre-conceptual phase (2013-2015) allows to increase the ISI and R tool ability for immersed sodium structures of ASTRID, at about 200 deg. C, on the basis of consolidated specifications and thanks to their qualification through more and more realistic laboratory tests and simulation with CIVA code. ISI and R items are being developed and qualified during a pluri-annual program which mainly deals with the reactor block structures, the primary components and circuit, and the Power Conversion System. It ensures a strong connection between the reactor designers and inspection specialists, as the optimization of inspectability and repairability is looked at: this already induced specific rules for design, in order to shorten and ease the ISI and R operations, which have been merged into RCC-MRx rules. In the frame of increasing technology readiness level with corresponding performance demonstration, this paper presents R and D dealing with the ISI and R items: it highlights the sensor development (both ultrasonic and electromagnetic concepts, compatible with sodium at 200 deg. C), then their applications for ASTRID structure control (under sodium telemetry, imaging and NDE). Activity for repair is also presented (a single laser tool for sodium sweeping, machining and welding), and finally the effort for associated robotic (generic program for ASTRID applications, specific technological tools for sodium medium, tight immersed bell). The main results of testing and simulation are given for telemetry, vision, NDE applications, laser process repair and under sodium sealing. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Detecting isolated resonance curves using fixed frequency voltage control tests

Isolated resonance curves, or isolas, are resonance branches of the harmonically forced system that exist separately from the main nonlinear forced response curve, leading to excessive vibrations. Traditional stepped or swept sine simulations and tests rely on continuation along the frequency parameter, typically resulting in a jump phenomenon along the primary resonance branch, prior to the disconnected isola. The main objective of this research is to propose an approach to identify isolated resonance curves by performing continuation along the input amplitude that initializes the response from a low-amplitude solution in the linear regime. Furthermore, this is achieved with the open-loop fixed frequency voltage control method that continues along the shaker voltage parameter and measures the so-called S-curves, which are theoretically a continuous solution branch that connect to the isola. The methodology is demonstrated on a fixture-wing-pylon assembly with a vibro-impact nonlinearity localized in a pylon subcomponent attachment. Multi-harmonic balance simulations are deployed to compute both the nonlinear forced response curves and S-curves to demonstrate the isola detection strategy on a reduced-order finite element model of the nonlinear system. Swept sine and fixed frequency voltage control tests are then conducted on the physical structure to demonstrate the isola detection experimentally, revealing the existence of the large amplitude vibrations that are undetected in the forces levels and frequencies measured with traditional frequency sweeping.

Characterization and Analytical Technique↗

A source-synchronous filter for uncorrelated receiver traces from a swept-frequency seismic source

We have developed a novel algorithm to reduce noise in signals obtained from swept-frequency sources by removing out-of-band external noise sources and distortion caused from unwanted harmonics. The algorithm is designed to condition nonstationary signals for which traditional frequency-domain methods for removing noise have been less effective. The source synchronous filter (SSF) is a time-varying narrow band filter, which is synchronized with the frequency of the source signal at all times. Because the bandwidth of the filter needs to account for the source-to-receiver propagation delay and the sweep rate, SSF works best with slow sweep rates and moveout-adjusted waveforms to compensate for source-receiver delays. The SSF algorithm was applied to data collected during a field test at the University of California Santa Barbara’s Garner Valley downhole array site in Southern California. At the site, a 45 kN shaker was mounted on top of a one-story structure and swept from 0 to 10 Hz and back over 60 s (producing useful seismic waves greater than 1.6 Hz). The seismic data were captured with small accelerometer and geophone arrays and with a distributed acoustic sensing array, which is a fiber-optic-based technique for the monitoring of elastic waves. The result of the application of SSF on the field data is a set of undistorted and uncorrelated traces that can be used in different applications, such as measuring phase velocities of surface waves or applying convolution operations with the encoder source function to obtain traveltimes. Lastly, the results from the SSF were used with a visual phase alignment tool to facilitate developing dispersion curves and as a prefilter to improve the interpretation of the data.

58 GEOSCIENCES↗

Performance, Combustion and Emissions Evaluation of Liquid Phase Port-Injected LPG on a Single Cylinder Heavy-Duty Spark Ignited Engine

Liquefied petroleum gas (LPG), like many other alternative fuels, has witnessed increased adoption in the last decade, and its use is projected to rise as stricter emissions regulations continue to be applied. However, much of its use is limited to dual fuel applications, gaseous phase injection, light-duty passenger vehicle applications, or scenarios that require conversion from gasoline engines. Therefore, to address these limitations and discover the most efficient means of harnessing its full potential, more research is required in the development of optimized fuel injection equipment for liquid port and direct injection, along with the implementation of advanced combustion strategies that will improve its thermal efficiency to the levels of conventional fuels. This paper focuses on the development of a liquid phase port-injection system for LPG, the design of a reference piston, and the baseline evaluation of the performance, combustion, and emissions characteristics of a single cylinder research engine to establish a benchmark comparable to existing LPG engines. A sweep of start of injection (SOI) timing is performed by injecting liquid LPG at several closed and open intake valve timings, which demonstrates no significant variation in engine performance, but accounts for a 10% reduction in bsCO with the optimal SOI timing. Spark timing sweep demonstrates the 50% burn crank angle location related to maximum brake torque (MBT) point with a brake thermal efficiency (BTE) of ~34% for the tested load case. The effect of equivalence ratio is also presented with optimal SOI timing at MBT condition. The engine starts exhibiting knocking combustion at 140kPa intake manifold air pressure (IMAP) with a peak torque of 253Nm and a 5% reduction in brake specific fuel consumption compared to the naturally aspirated scenario.

Fosudo, Toluwalase↗

MICP in the Field: Enhancement of Wellbore Cement Integrity and Permeability Modification

Microbially-induced calcite precipitation (MICP) is being widely researched as an emerging technology for subsurface engineering applications including sealing defects in wellbore cement and modifying the permeability of rock formations [1]. Our study team, including Montana State University’s Energy Research Institute and Center for Biofilm Engineering, The University of Stuttgart, Montana Emergent Technologies, and Schlumberger Carbon Services, has conducted two successful MICP-based field trials. The first field test successfully used MICP to seal a horizontal “pancake fracture” in tight sandstone [2]. The following test resulted in MICP sealing of compromised wellbore cement. Both tests were carried out in the Gorgas well in Alabama and used the ureolytic bacteria, Sporosarcina pasteurii, to promote calcium carbonate precipitation. A third field test is now underway targeting an existing oil well, Rexing #4, in Indiana. The Rexing #4 well was previously used as an injection well to sweep residual oil to production wells. Several years ago, injection pressure was lost, and the well was removed from service. Subsequent well logging measurements suggested that, rather than entering the target injection formation, injectate was traveling up the wellbore through defects in the well cement to a sandstone thief zone approximately 50 feet above the target formation. The goal of the field demonstration project at the Rexing #4 well is to use MICP to reduce permeability in the thief zone and cement defect until the injection pressure reaches the pre-breakthrough condition necessary to return Rexing #4 to service as an injection well. The field demonstration in Indiana, funded by the US Department of Energy, will be conducted the first week of December 2017 using a custom mobile laboratory designed for field applications of MICP. Results presented at the conference will include a rationale for the injection strategy employed, as well as its success at sealing the leakage pathway.

Kirkland, Catherine↗

Evaluation of BISON's Transient Fission Gas Release Model on High-Burnup UO 2 MiniFuel

BISON's fission gas release (FGR) model has been evaluated and tested over several hypothetical thermal transient cases at high burnup and validated against FGR experimental data from an annealing test at high burnup. Diffusion-controlled FGR is accounted for in the model by including several physical mechanisms such as the diffusion of fission gas to grain faces, grain boundary sweeping, grain growth, and intergranular bubble growth. Under temperature variations, FGR is increased due to the development of micro-cracks at grain faces. This existing transient capability, however, was developed based on transient fuel behavior during power ramps and the associated micro-cracking process. Nevertheless, a fraction of the FGR during temperature transients such as LOCA can ensue from different mechanisms (in particular, fuel fragmentation) and present an important dependency on local burnup and high burnup structure formation. It follows that the performance and necessary developments of the existing BISON fission gas model for the analysis of LOCA-type transients need to be investigated through a systematic assessment study. Such a study is performed in this work. The model shows an overall good qualitative agreement with experimental observations on FGR during annealing tests with different temperature conditions. It also accounts well for microstructural effects on FGR. When quantitatively compared to FGR data from previously irradiated 103 MWd/kgU UO 2 discs under thermal annealing, the model shows a less satisfactory agreement with the experimental data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Achieving superior carbon transfer efficiency and pH control using membrane carbonation with a wide range of CO 2 contents for the coccolithophore Emiliania huxleyi

The economic viability of microalgal-derived products relies on rapid CO 2 transfer in a cost-effective manner. Many industrial gas streams contain concentrated CO 2 that, if converted to useful products, would lower greenhouse gas emissions and valorize the wasted CO 2 . Membrane carbonation (MC) uses non-porous hollow-fiber gas-transfer membranes to deliver CO 2 without bubble formation, which makes it possible to achieve a high carbon-transfer efficiency (CTE). However, inert gasses in the industrial streams (e.g., N 2 , O 2 , and H 2 O) can significantly lower the CO 2 -delivery rate. The means to overcome the buildup of inert gases in the membrane lumen is to manage the distal end of the membranes to sweep out inert gases while not wasting significant CO 2 . A MC-venting strategy was evaluated for CO 2 inputs from 5% to 100%. Abiotic tests using a restricted exit flow could achieve >95% CTE abiotic for industrial CO 2 streams. When integrated with semi-continuous cultivation of a marine coccolithophore, Emiliania huxleyi , CO 2 delivery and venting were on-demand based on a pH set points and pH-actuated feed and venting valves. MC using the venting strategy achieved 100% CTE biotic when delivering 100% and 50% CO 2 , which was better than 50% CTE biotic obtained from pH-controlled sparging of 100% CO 2 -sparging. E. huxleyi consistently fixed ~80% of the delivered CO 2 into biomass, and the remaining ~20% to calcite coccoliths. Finally, the compact size of MC modules, stable pH control, and no shear forces from bubble agitation during the CO 2 delivery made MC an ideal match for cultivation of coccolithophores, which are sensitive to shear forces and pH fluctuations.

54 ENVIRONMENTAL SCIENCES↗

Observations of the frequency tuning effect in the 14 GHz CAPRICE ion source

A set of measurements with the CAPRICE ion source at the GSI test bench has been carried out to investigate its behavior in terms of intensity and shape of the extracted beam when the microwaves generating the plasma sweep in a narrow range of frequency ({+-}40 MHz) around the klystron center frequency (14.5 GHz). Remarkable variations have been observed depending on the source and the beamline operating parameters, confirming that a frequency dependent electromagnetic distribution is preserved even in the presence of plasma inside the source. Moreover, these observations confirm that the frequency tuning is a powerful method to optimize the electron cyclotron resonance ion source performances. A description of the experimental setup and of the obtained results is given in the following.

43 PARTICLE ACCELERATORS↗

Distribution Grid Modeling Using Smart Meter Data

The knowledge of distribution grid models, including topologies and line impedances, is essential for grid monitoring, control and protection. However, such information is often unavailable, incomplete or outdated. The increasing deployment of smart meters (SMs) provides a unique opportunity to tackle this issue. This paper proposes a two-stage framework for distribution grid modeling using SM data. In the first stage, the network topology is identified by reconstructing a weighted Laplacian matrix of distribution networks. In the second stage, a least absolute deviations (LAD) regression model is developed for estimating line impedance of a single branch based on the nonlinear (inverse) power flow model, wherein a conductor library is leveraged to narrow down the solution space. The LAD regression model is originally a mixed-integer nonlinear program whose continuous relaxation is still non-convex. Furthermore, we specially address its convex relaxation and discuss the exactness. The modified regression model is then embedded within a bottom-up sweep algorithm to achieve the identification across the network in a branch-wise manner. Numerical results on the IEEE 13-bus, 37-bus and 69-bus test feeders validate the effectiveness of the proposed methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing Heavy-Oil-Recovery Efficiency by Combining Low-Salinity-Water and Polymer Flooding

Summary Combining low-salinity-water (LSW) and polymer flooding was proposed to unlock the tremendous heavy-oil resources on the Alaska North Slope (ANS). The synergy of LSW and polymer flooding was demonstrated through coreflooding experiments at various conditions. The results indicate that the high-salinity polymer (HSP) (salinity = 27,500 ppm) requires nearly two-thirds more polymer than the low-salinity polymer (LSP) (salinity = 2,500 ppm) to achieve the target viscosity at the condition of this study. Additional oil was recovered from LSW flooding after extensive high-salinity-water (HSW) flooding [3 to 9% of original oil in place (OOIP)]. LSW flooding performed in secondary mode achieved higher recovery than that in tertiary mode. Also, the occurrence of water breakthrough can be delayed in the LSW flooding compared with the HSW flooding. Strikingly, after extensive LSW flooding and HSP flooding, incremental oil recovery (approximately 8% of OOIP) was still achieved by LSP flooding with the same viscosity as the HSP. The pH increase of the effluent during LSW/LSP flooding was significantly greater than that during HSW/HSP flooding, indicating the presence of the low-salinity effect (LSE). The residual-oil-saturation (Sor) reduction induced by the LSE in the area unswept during the LSW flooding (mainly smaller pores) would contribute to the increased oil recovery. LSP flooding performed directly after waterflooding recovered more incremental oil (approximately 10% of OOIP) compared with HSP flooding performed in the same scheme. Apart from the improved sweep efficiency by polymer, the low-salinity-induced Sor reduction also would contribute to the increased oil recovery by the LSP. A nearly 2-year pilot test in the Milne Point Field on the ANS has shown impressive success of the proposed hybrid enhanced-oil-recovery (EOR) process: water-cut reduction (70 to less than 15%), increasing oil rate, and no polymer breakthrough so far. This work has demonstrated the remarkable economical and technical benefits of combining LSW and polymer flooding in enhancing heavy-oil recovery.

Engineering↗

Technology on In-Situ Gas Generation to Recover Residual Oil Reserves

This final technical report covers the period October 1, 1995 to February 29, 2008. This chapter begins with an overview of the history of Enhanced Oil Recovery techniques and specifically, CO2 flood. Subsequent chapters conform to the manner consistent with the Activities, Tasks, and Sub-tasks of the project as originally provided in Exhibit C1 in the Project Management Plan dated September 20, 1995. These chapters summarize the objectives, status and conclusions of the major project activities performed during the project period. The report concludes by describing technology transfer activities stemming from the project and providing a reference list of all publications of original research work generated by the project team or by others regarding this project. The overall objective of this project was a final research and development in the United States a technology that was developed at the Institute for Geology and Development of Fossil Fuels in Moscow, Russia. Before the technology can be convincingly adopted by United States oil and gas producers, the laboratory research was conducted at Mew Mexico Institute of Mining and Technology. The experimental studies were conducted to measure the volume and the pressure of the CO{sub 2} gas generated according to the new Russian technology. Two experimental devices were designed, built and used at New Mexico Tech facilities for these purposes. The designed setup allowed initiating and controlling the reaction between the 'gas-yielding' (GY) and 'gas-forming' (GF) agents proposed by Russian technology. The temperature was controlled, and the generated gas pressure and volume were recorded during the reaction process. Additionally, the effect of surfactant addition on the effectiveness of the process was studied. An alternative GY reactant was tested in order to increase the efficiency of the CO2 gas generation process. The slim tube and the core flood experimental studies were conducted to define the sweep efficiency of the in-situ generated CO{sub 2} gas. A set of core flood experiments were conducted to define effect of surfactant on recovery efficiency. The results demonstrated obvious advantages of the foamy system over the brine solution in order to achieve higher sweep efficiency and recovery coefficient. It is shown that a slug injection is not an efficient method for mixing GY and GF solutions and it can't generate considerable gas inside the slim-tube.

02 PETROLEUM↗

Glass Strengthening via High-Intensity Plasma-Arc Heating

The use of a high-intensity plasma-arc lamp was used to irradiate the surface of soda-lime silicate glass tiles to determine if an increase in strength could be achieved. The lamp had a power density of 3500 W/cm2, a processing area of 1 cm x 10 cm, irradiated near-infrared heating at a wavelength between 0.2 1.4 m, and was controlled to unidirectionally sweep across 50-mm-square tiles at a constant speed of 8 mm/s. Ring-on-ring (RoR) equibiaxial flexure and 4 pt uni-directional flexure testings of entire tiles were used to measure and compare failure stress distributions of treated and untreated glass. Even with non-optimized processing conditions, RoR failure stress increased by approximately 25% and the 4 pt bend failure stress increased by approximately 65%. Strengthening was due to a fire-polishing-like mechanism. The arc-lamp heat-treatment caused the location of the strength-limiting flaws in the 4-pt-bend tiles to change; namely, failure initiation occurred on the gage section surface for the treated glass whereas it occurred at a gage section edge for the untreated. Arc-lamp heat-treatment is attractive not only because it provides strengthening, but because it can (non-contact) process large amounts of glass quickly and inexpensively, and is a process that either a glass manufacturer or end-user can readily employ.

36 MATERIALS SCIENCE↗