At-power subcritical multiplication in the Advanced Test Reactor during nuclear requalification testing

Power division information during nuclear requalification of the Advanced Test Reactor (ATR) is of considerable interest as an importance function for observed changes to core reactivity. The degree to which a given physical subdivision of a critical reactor acts as a neutron source for other lobes is not analytically characterized for general application. When ATR operates at power, individual power-producing lobes rely on each other as neutron sources in order to maintain constant power, which in general requires either exactly critical multiplication within a reactor or an external neutron source. Here, this work shows that fuel element and lobe powers in ATR can be related with subcritical multiplication theory. Subcritical multiplication factors are computed with a physically validated analytical method based on actual at-power operation, quantifying for each lobe its dependence on other lobes as an external neutron source. This explanation is significant for ATR due to the desire to irradiate a large variety of experiments simultaneously, each having its impact on the core neutron population. For any physical subdivision of any other critical reactor, it is likewise true that the subdivision undergoes only subcritical multiplication.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Initial Delayed Critical Configuration of SHEBA I and Subcritical Measurements by Californium Source-Driven Noise Analysis

In September 1980, the initial delayed critical configuration of the Solution High-Energy Burst Assembly (SHEBA I) was assembled, and the US Department of Energy’s Oak Ridge National Laboratory (ORNL) staff performed near critical and subcritical measurements using the californium source-driven noise analysis (CSDNA) method at the Los Alamos National Laboratory (LANL) Critical Experiments Facility. An unreflected 56 cm outside diameter stainless-steel cylindrical tank was partially filled with uranyl fluoride solution (235U enrichment was 4.95 wt %) until delayed criticality was achieved. Then, measurements were performed for various fuel solution heights from delayed critical to 60% of the height required for delayed criticality. The stainless-steel tank had an inside diameter of 54.6 cm and a height of 105 cm and was partially (20–36.5 cm) filled with an aqueous solution of uranyl fluoride (with a density of 2.162 g/cm 3 ). The density of the uranium in solution was 1.042 g/cm 3 , and the solution had a H/U atomic ratio of 20.43. The tank had a 6.35 mm wall thickness and an axial reentrant tube with an inside diameter of 6.02 cm and wall thickness of 0.165 cm. The tank was essentially unreflected on the top and sides because it was in a thin metal shed. The reactivity of the near–delayed critical configuration was −10.4 cents, which corresponds to a k eff value of 0.99922. In addition to the CSDNA measurements, the prompt neutron decay constants were determined from break frequency noise analysis (BNFA) measurements. The subcritical neutron multiplication factors from CSDNA and BFNA compared extremely well. These data can be used as the basis of International Nuclear Criticality Safety Evaluation benchmark for the near-critical configuration, and the k eff values at various subcritical configurations can be used as subcritical benchmarks. Furthermore, the measured prompt neutron decay constants can be used as reactor physics benchmarks. This report documents the experimental information for the measurements performed so that, at a later date, researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Evaluation Program (ICSBEP) or Nuclear Energy Agency benchmarks. The measured prompt neutron decay constants can be used as the basis of a benchmark for the International Reactor Physics Evaluation Program (IRPhEP). The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative Analysis of Standard and Advanced USL Methodologies for Nuclear Criticality Safety

The American National Standards Institute/American Nuclear Society national standards 8.1 and 8.24 provide guidance on the requirements and recommendations for establishing confidence in the results of the computerized models used to support operation with fissionable materials. By design, the guidance is not prescriptive, leaving freedom to the analysts to determine how the various sources of uncertainties are to be statistically aggregated. Due to the involved use of statistics entangled with heuristic recipes, the resulting safety margins are often difficult to interpret. Also, these technical margins are augmented by additional administrative margins, which are required to ensure compliance with safety standards or regulations, eliminating the incentive to understand their differences. With the new resurgent wave of advanced nuclear systems, e.g., advanced reactors, fuel cycles, and fuel concepts, focused on economizing operation, there is a strong need to develop a clear understanding of the uncertainties and their consolidation methods to reduce them in manners that can be scientifically defended. In response, the current studies compare the analyses behind four notable methodologies for upper subcriticality limit estimation that have been documented in the nuclear criticality safety literature: the parametric, nonparametric, Whisper, and TSURFER methodologies. Specifically, the work offers a deep dive into the various assumptions of the noted methodologies, their adequacies, and their limitations to provide guidance on developing confidence for the emergent nuclear systems that are expected to be challenged by the scarcity of experimental data. Here, to limit the scope, the current work focuses on the application of these methodologies to criticality safety experiments, where the goal is to calculate a bias, a bias uncertainty, and a tolerance limit for k eff in support of determining an upper subcriticality limit for nuclear criticality safety.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Measurement uncertainty of rossi-alpha neutron experiments

Rossi-alpha neutron experiments are used to estimate the prompt neutron decay constant of a fissile assembly, a quantity of widespread interest in applications including in nuclear nonproliferation and criticality safety. This work develops a mathematical model to efficiently estimate measurement uncertainty of Rossi-alpha neutron experiments inferred from a two-exponential fit model with histogram binning. The derived uncertainty estimates were validated using repeated Rossi-alpha measurements of a subcritical, 4.5-kg sphere of weapons-grade, alpha-phase plutonium with nickel, copper, tungsten, and polyethylene reflectors. The estimates of uncertainty for the histogram data produced by the model were conservative and agree with the reference uncertainties within noise. The estimates of the prompt neutron decay constant uncertainty agreed with the reference uncertainties within one standard deviation. In conclusion, the proposed model will reduce total measurement times, ultimately reducing operational and procedural costs in application.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Subcritical Californium Source Drive Noise Analysis Measurements With Unreflected Uranium (93.15) Hydride

On July 6, 1989, subcritical californium source-driven noise analysis (CSDNA) measurements were performed with bare uranium hydride cylindrical assemblies at the Los Alamos National Laboratory Critical Experiments Facility in KIVA 1. Three configurations of ~7.5 cm radius-enriched (93.15 wt. % 235 U) uranium hydride with a density of ~10 g/cm 3 cylinders were assembled with uranium hydride heights of ~11, ~14, and ~16 cm. The uranium hydride (~2 and ~3 cm high) was in thin-welded stainless steel cans. The neutron multiplication factors obtained on-line from the measured ratios of spectral densities were 0.942 ± 0.002, 0.917 ± 0.003, and 0.867 ± 0.004 for uranium hydride heights of ~16, ~14, and ~11 cm., respectively. Neutron multiplication factors for these three configurations calculated by Los Alamos National Laboratory Monte Carlo methods were 0.952 ± 0.005, 0.922 ± 0.005, and 0.860 ± 0.005, all of which are in good agreement with the measurements. The break frequency noise analysis data could be fitted to obtain the prompt neutron decay constant at all subcritical states. Some data presented in this report are from notes that are not in the logbooks. A discussion of the two different point kinetics theories of the measurements that illustrated the deficiencies of the rigorous theory at low neutron multiplication factors (k eff < 0.80) is given in an Appendix. These measurements may be the only configuration of unreflected, highly enriched uranium hydride configuration assembled. The presence of hydrogen diluted the uranium density, decreasing the reactivity, but this is offset by slowing down the neutron energy to the energy ranges of higher-fission cross sections. Extrapolations to delayed critical indicate that adding one more 3 cm can and one more 2 cm can would result in the unreflected cylindrical system being slightly above critical with a critical mass of ~37 kg, which is considerably less than the critical mass of an unreflected and unmoderated highly enriched uranium metal sphere. An unreflected, highly enriched uranium hydride sphere would have a critical mass less than 37 kg.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SPARC - Plans for a New Critical Experiment Facility with a Horizontal Split Table

Several critical experiment facilities, sometimes referred to as zero power reactor facilities, have provided crucial data to aid understanding and validate nuclear-physics models since the beginning of nuclear technology. Indeed, the first man-made reactor, Chicago Pile-1, was essentially this type of reactor. However, there was a downturn in nuclear technology development toward the turn of the millennium, and the need for these specialized research facilities waned. Now there are few of these experimental facilities operational in the world and those that remain have relatively small critical assembly machines. The need for criticality safety benchmark experiments at intermediate neutron energy levels and the modern resurgence of interest in advanced reactors designs, many of which do not have historical precedents in terms of nuclear fuel composition, moderator, and coolant combinations, all combine to create a substantial need for a critical experiment facility with a large horizontal split-table (HST) machine. A HST machine is used to arrange two separate and subcritical parts of a core assembly, bring them together in a precise manner to achieve criticality using remote controls, and separate them to achieve a subcritical configuration again. A new effort was recently performed to develop user needs for a HST, assess candidate locations at the Idaho National Laboratory (INL), and develop a plan for deployment. This project is referred to as the System Physics Advanced Reactor Critical facility (SPARC). A few months after this assessment began, and shortly after as a viable pathway was emerging, a series of important presidential executive orders were issued to revitalize nuclear energy in the United States (U.S.). The relevance of SPARC to these executive orders was immediately apparent. The far-reaching potential of SPARC to these executive orders will reside in its ability to produce data which facilitates licensing of advanced nuclear reactor designs while reducing uncertainties to help increase energy production alongside new criticality safety data to enable more efficient nuclear fuel manufacture, transport, and storage.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

The fast neutron source at UTK: a project with Massimo Salvatores

This article is dedicated to the memory of Massimo Salvatores and offers an overview of the history of the design of the Fast Neutron Source (FNS) flexible experiment system at the University of Tennessee. Our collaboration with Massimo set much of the over-arching design goals and inspired the concept that we have today. The decision to design the FNS as a subcritical assembly rather than a critical one stems back to discussions with Massimo Salvatores and his advocacy for subcritical Accelerator Driven Systems (ADS) which coincides with lower licensing time, costs and greater safety for a university-operated nuclear experimental facility. The second contribution of Massimo to the design concept of the FNS was the direct instruction to design the FNS as an extremely flexible facility. This article provides an update on the current design concept and discusses the future innovations in design optimization of flexible, re-configurable nuclear experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design Optimization of a Criticality Experiment for the Molten Chloride Reactor Experiment Facility

Neutronics simulations of Molten Chloride Fast Reactors have quantifiable biases that arise from nuclear data, modeling choices, or numerical methods. The multiphysics nature of molten salt reactors makes it challenging to disentangle neutronics modeling biases from biases originating from other physical phenomena. In comparison to a mock-up reactor, criticality experiments can specifically assess the neutronics modeling bias while limiting multiphysics effects. The criticality experiment must be neutronically representative of the full-scale reactor to be valuable. Here, in this paper, we describe the design of a criticality experiment to validate only the neutronics of TerraPower’s Molten Chloride Reactor Experiment (MCRE) and its criticality safety upset scenarios. The proposed experiment uses different chlorine-containing materials to maximize its similarity to the MCRE. The design process uses a constrained Bayesian optimization algorithm to investigate different objective functions that use covariance information for 35 Cl nuclear data. The experiments could reduce the nuclear data–induced uncertainty in k eff of the MCRE from 2161 to 886 pcm. They would also increase the upper subcritical limit of the MCRE criticality safety upset scenario from 0.94101 to 0.94476 when using the WHISPER analysis framework.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Progress Towards the Reality of Low-Temperature Critical Experiments with Low-Temperature TEX

Integral benchmarks for criticality safety do not exist below room temperature. Incredible support for below room temperature benchmarks is present across the international community. Validation of low-temperature neutron cross sections is necessary to verify any operation at temperatures below room temperature which is typically observed in environments far from the equator. For example, a fissile material transportation truck may routinely observe ambient temperatures down to -40°C, which is the lower temperature bound of the normal conditions of transportation defined in the United States Title 10 Code of Federal Regulations §71.71c2. Similarly, the IAEA, which contains 176 member states, has the same requirement for subcriticality for fissile material transportation. Additionally, sub-room temperature benchmarks can validate newly produced cross sections, that include novel thermal scattering laws, from North Carolina State University. A six-case experiment designed based off the TEX-HEU baseline experiments has been proposed utilizing a chilled vacuum chamber capable of cooling the HEU stack down to -50°C. The six proposed configurations span the entire neutron fission energy range and can be tested at intermediate temperatures between room temperature and -40°C. Of the six configurations, the fastest case utilizes nearly 135 kg of HEU. Understanding the system is required prior to critical experiment operations. In order to test the functionality of the system, testing with surrogate fuel materials has been conducted. The following discusses the design of the low temperature TEX (LT-TEX) experiment as well as the progress made via surrogate testing towards a reality in which low-temperature integral benchmarks exist in the International Criticality Safety Benchmark Evaluation Project (ICSBEP).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On the Feynman-alpha method for reflected fissile assemblies

The Feynman-alpha method is a neutron noise technique that is used to estimate the prompt neutron period of fissile assemblies. The method and quantity are of widespread interest including in applications such as nuclear criticality safety, safeguards and nonproliferation, and stockpile stewardship; the prompt neutron period may also be used to infer the k eff multiplication factor. The Feynman-alpha method is predicated on time-correlated neutron detections that deviate from a Poisson random variable due to multiplication. Traditionally, such measurements are diagnosed with one-region point kinetics, but two-region models are required when the fissile assembly is reflected. This paper presents a derivation of the two-region point kinetics Feynman-alpha equations based on a double integration of the Rossi-alpha equations, develops novel propagation of measurement uncertainty, and validates the theory. Validation is achieved with organic scintillator measurements of weapons-grade plutonium reflected by various amounts of copper to achieve k eff values of 0.83–0.94 and prompt periods of 5–75 ns. The results demonstrate that Feynman-alpha measurements should use the two-region model instead of the one-region model. The simplified one-region model deviates from the validated two-region models by as much as 10% in the estimate of the prompt neutron period, and the two-region model reduces to the one-region model for small amounts of reflector. The Feynman-alpha estimates of the prompt neutron period are compared to those of the Rossi-alpha approach. The comparative results demonstrate that the Feynman-alpha method is more precise than the Rossi-alpha method and more accurate for k eff < 0.92, whereas the Rossi-alpha method is generally more accurate for higher multiplications. Here, the uncertainty propagation developed in this work should be used for all Feynman-alpha measurements and will therein improve fitting accuracy and appropriate precision estimates.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Generation of strong fields with subcritical density plasmas to study the phase transitions of magnetized warm dense matter

Warm dense matter (WDM) is a regime where Fermi degenerate electrons play an important role in the macroscopic properties of a material. Recent experiments have brought us closer to understanding unmagnetized processes in WDM, but magnetized WDM remains unexplored because kilotesla magnetic fields are required. Although there are examples of field compression generating such fields by imploding pre-magnetized targets, these existing methods give no independent control over the parameters of the magnetized plasma and result in limited laser access for sample creation and diagnosis. In this paper, numerical simulations show that kilotesla magnetic fields can be obtained by shining laser beams onto the inner surface of a cylindrical target, rather than on the outer surface. This approach relies on field compression by a low-density, high-temperature plasma, rather than a high-density, low-temperature plasma, used in the more conventional approach. With this novel configuration, the region of peak magnetic field is mostly free of plasma, hence, other beams can reach a sample placed in the region of the peak field to form WDM and diagnose it.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of NCERC Critical Experiments with ENDF/B Nuclear Data Libraries

Nuclear data (ND) libraries are the backbone of the nuclear industry, as they are the collections of tabulated probabilities that define sub-atomic particle interactions with matter. In the areas of criticality safety and experiments, no evaluated nuclear data files (ENDF) are more important than those containing neutron cross section data. It is upon these files, and accompanying radiation transport codes, that practitioners are enabled to safely design both subcritical and critical systems. Likewise, in a symbiotic fashion, it is the same critical assemblies which are used primarily to validate that the cross sections are correct. The ENDF/B library, the United States’ national library maintained by the National Nuclear Data Center (NNDC) at Brookhaven National Laboratory (BNL), is soon releasing a new version, ENDF/B-VIII.1. Prior to the official release, several beta versions of the library were prepared and tested in simulation suites. The work presented here are results comparing the newest ENDF/B beta release (ENDF/B-VIII.1b3) and ENDF/B-VIII.0 with recent experiments done at the National Criticality Experiments Research Center (NCERC) as well as correlated experiments from the Los Alamos Critical Experiments Facility (LACEF). These NCERC and LACEF experiments were performed in part to provide validation for various cross sections that were identified as insufficient in the ENDF/B-VIII.0. In particular, lead, copper, fluorine, and chlorine, as well as the major actinides, were targeted from the last decade of critical experiments.

97 MATHEMATICS AND COMPUTING↗

Microreactor Assembly Transportation Cask Model Description for Criticality Safety Validation Basis Assessment

Criticality safety analyses are completed on a transportation cask used for microreactor assembly shipment to provide an example of model and analysis to industry for reproducing this type of study on their microreactor fuel shipment. The fuel assembly considered is based on a gas-cooled microreactor (GC-MR), which utilizes HALEU fuel in the form of TRISO particles and utilizes various design options considered in industry designs. Various versions of this GC-MR assembly were studied, with and without YH2 moderator, providing similar conclusions. The shipment cask design is revised based on an existing design ES-3100, developed by Y-12 for the transport of highly enriched uranium (HEU), but is enlarged to hold the GC-MR fuel assembly. Criticality safety analysis for the cask/GC-MR fuel assembly package was performed using the CSAS6 sequence of SCALE6.3.2, utilizing the ENDF/B-VII.1 based continuous energy neutron library, and the analysis strictly follows the guideline from NRC reference reports. Different scenarios, e.g. normal operation, undamaged cask with water flooded, damaged cask with optimal water moderation, have been analyzed and it could be concluded the package would always have a large margin of subcriticality even packed in an infinite array. Sensitivity and similarity analyses are also performed using the TSUNAMI sequence of SCALE6.3.2, and the similarity analysis uses all the experiments from the ICSBEP Handbook with Intermediate and Mixed Enriched Uranium (IEU) and Low Enriched Uranium (LEU) systems together with additional ones that are sponsored by the DNCSH program. These similarity analyses indicate that dry cases have no similar benchmark experiments (ck values greater than 0.8), which may become problematic if more assemblies are shipped together (or a fully loaded core is shipped) and margin to criticality is reduced. However, the damaged cask models with flooded assemblies exhibited similarities to many experiments with ck values greater than 0.8.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microreactor Assembly Transportation Cask Model Description for Criticality Safety Validation Basis Assessment (Rev. 3)

Criticality safety analyses are completed on a transportation cask used for microreactor assembly shipment to provide an example of model and analysis to industry for reproducing this type of study on their microreactor fuel shipment. The fuel assembly considered is based on a gas-cooled microreactor (GC-MR), which utilizes HALEU fuel in the form of TRISO particles and utilizes various design options considered in industry designs. Various versions of this GC-MR assembly were studied, with and without YH 2 moderator, providing similar conclusions. The shipment cask design is revised based on an existing ES-3100 design, developed by Y-12 for the transport of highly enriched uranium (HEU), but is enlarged to hold the GC-MR fuel assembly. Criticality safety analysis for the cask/GC-MR fuel assembly package was performed using the CSAS6 sequence of SCALE6.3.2, utilizing the ENDF/B-VII.1 based continuous energy neutron library, and the analysis strictly follows the guideline from NRC reference reports. Different scenarios, e.g. normal operation, undamaged cask with water flooded, damaged cask with optimal water moderation, have been analyzed and it could be concluded the package would always have a large margin of subcriticality even packed in an infinite array. Sensitivity and similarity analyses are also performed using the TSUNAMI sequence of SCALE6.3.2, and the similarity analysis uses all the experiments from the ICSBEP Handbook with Highly Enriched Uranium (HEU), Intermediate and Mixed Enriched Uranium (IEU) and Low Enriched Uranium (LEU) systems, together with additional ones that are sponsored by the DNCSH program, and selected IRPhEP experiments using TRISO fuel and graphite moderator. These similarity analyses indicate that the dry nominal design has no similar benchmark experiments (ck values greater than 0.8), which may become problematic if more assemblies are shipped together (or a fully loaded core is shipped) and margin to criticality is reduced. However, the cask models with flooded assemblies exhibited similarities to many experiments with c k values greater than 0.8.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NCERC Capabilities [Slides]

NCERC is our nation’s only generalpurpose critical experiments facility and is one of only a few that remain operational throughout the world. The mission of the National Criticality Experiments Research Center (NCERC) is to conduct experiments and training with critical assemblies and fissionable material at or near criticality in order to explore reactivity phenomena, and to operate the assemblies in the regions from subcritical through delayed critical. One critical assembly, Godiva-IV, is designed to operate above prompt critical.

61 RADIATION PROTECTION AND DOSIMETRY↗

Availability of Critical Benchmark Experiments for the Pebble Tanker Transportation Model for Nuclear Criticality Safety Validation of TRISO Pebbles

This study addresses the need for comprehensive investigations into TRi-structural ISOtropic (TRISO) fuel pebble transportation validation. In this work, an exploratory model, the pebble tanker(PT), was developed with the aim of facilitating the validation of nuclear criticality safety calculations in the context of industrial-scale transportation of TRISO fuel. The PT model was designed to investigate the availability and applicability of critical benchmark experiments crucial for assessing the transportation of these pebbles. This work incorporated sensitivity/uncertainty (S/U) similarity studies to quantify the applicability of critical benchmark experiments and to address nuclear data uncertainties in the context of TRISO transportation. Two container models were investigated: one for the Hermes-type pebble and one for the Pebble Bed Modular Reactor (PBMR)–type pebble. The models were simplified, considering fuel, containment, and either water or air, to enable a focus on the underlying physics of applications involving TRISO fuel pebbles using the PT model. A crucial aspect under consideration was the capacity of the transport package to hold pebbles while ensuring subcriticality in the flooded state. An approach in the criticality validation process involves assessing the similarity between systems through an integral index parameter evaluation. This involves calculating a correlation coefficient (referred to as c k ) based on shared nuclear data–induced uncertainty between a benchmark experiment and the application of the PT model. To facilitate this analysis, the SCALE tools, particularly the CSAS6-Shift, TSUNAMI-3D-Shift, and TSUNAMI-IP sequences, were employed for comprehensive studies in neutronics and S/U analysis. Our findings showed that there are sufficient critical experimental benchmarks to perform this validation of the PT model in the most reactive state, i.e. when the tanker is flooded. This paper provides valuable insights into validating a transport package for Generation IV TRISO fuel pebbles.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

VADER: A Tool for Criticality Safety Validation

The purpose of criticality safety is to prevent any inadvertent criticality from occurring during the handling or storage of fissile material. Calculations are frequently used to demonstrate that a sufficient subcritical margin exists. Validation is a key aspect of the evaluation process, establishing the suitability, accuracy, and associated uncertainty of the computational method and data to be used for the intended application. The validation process is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 in order to investigate the parameters at which such a critical condition is achieved. The validation parameters that are traditionally applied to safety analysis calculations are the bias and the bias uncertainty . The bias is the deviation of the average k eff of the validation suite from unity. The bias uncertainty accounts for the statistical uncertainty in the bias based on the standard deviation, sample size, and distribution of k eff values of the validation suite. The values of bias and bias uncertainty ensure that the systems predicted to be subcritical by the computational method will indeed be subcritical. The bias and bias uncertainty are often combined to determine an upper subcritical limit (USL) or computational margin that can then be applied to safety analysis calculations. Many methods have been developed by different organizations to calculate the bias and bias uncertainty for various types of criticality analyses. Each of these methods typically requires that the validity of various underpinning statistical assumptions be confirmed to demonstrate that the method is appropriate for the analysis of a given validation suite. An example of the validation decision making flow is shown in Fig.1. As shown in Fig. 1, the analyst performing the validation fits a trend line to the data and performs a test to determine if the trend was a statistically better representation of the data than if it were treated as an uncorrelated sample. If the trend line is a better representation of the data, then the analyst uses any one of a number of trending techniques to determine the bias and bias uncertainty. If a trend is not an appropriate representation of the data, then the analyst proceeds to perform a normality assessment for the data. If the normal assumption can be shown to be acceptable, then the analyst calculates the bias and bias uncertainty with the parametric technique. If the assumption of normality cannot be justified, then the nonparametric technique is used. Once the decision flow has been followed and the appropriate technique has been selected, the bias and bias uncertainty is typically combined with an administrative margin to determine a USL below which calculated values of k eff for safety analysis models can be considered subcritical. The calculations used in each decision are often performed with spreadsheets or with small programs available at various sites performing criticality analyses. Expertise in understanding and interpreting the results must be maintained to perform these calculations. This can often be an error-prone process. Oak Ridge National Laboratory (ORNL) is currently developing the Validation and Data Evaluation Resource (VADER) to simplify and automate the criticality safety validation process and to provide a software quality assurance pedigree to the calculational methods used. This paper discusses the use of the Fulcrum user interface with VADER, the anticipated initial capabilities of VADER to perform validation analyses, and the output from the code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗