Thermophysical ESEM Characterization of Carbon Fibers

Coefficients of thermal expansion (CTE) of carbon fibers create residual stresses in aggressive manufacturing and service environments. In this effort, environmental scanning electron microscope (ESEM) is used for in situ observations of a carbon fiber cross-section up to 1000 C in order to evaluate the much neglected transverse CTE. The perimeter of fiber cross-section is calculated with the Scion image processing program from images that were taken at every 100 C increments. CTE values are calculated by linear regression of the strain data based on the perimeter changes. Furthermore, through SEM, WDS and TEM observations, we are in the process of bringing an interactive rationale between CTE, crystallinity and surface roughness of carbon fibers.

Sue, Jiwoong↗

Three-Dimensional Digital Image Correlation of a Composite Overwrapped Pressure Vessel During Hydrostatic Pressure Tests

Ambient temperature hydrostatic pressurization tests were conducted on a composite overwrapped pressure vessel (COPV) to understand the fiber stresses in COPV components. Two three-dimensional digital image correlation systems with high speed cameras were used in the evaluation to provide full field displacement and strain data for each pressurization test. A few of the key findings will be discussed including how the principal strains provided better insight into system behavior than traditional gauges, a high localized strain that was measured where gages were not present and the challenges of measuring curved surfaces with the use of a 1.25 in. thick layered polycarbonate panel that protected the cameras.

Revilock, Duane M., Jr.↗

Buckling Test Results from the 8-Foot-Diameter Orthogrid-Stiffened Cylinder Test Article TA01

Results from the testing of cylinder test article SBKF-P2-CYLTA01 (referred to herein as TA01) are presented. The testing was conducted at the Marshall Space Flight Center (MSFC), November 19‒21, 2008, in support of the Shell Buckling Knockdown Factor (SBKF) Project.i The test was used to verify the performance of a newly constructed buckling test facility at MSFC and to verify the test article design and analysis approach used by the SBKF project researchers. TA01 is an 8-foot-diameter (96-inches), 78.0-inch long, aluminum-lithium (Al-Li), orthogrid-stiffened cylindrical shell similar to those used in current state-of-the-art launch vehicle structures and was designed to exhibit global buckling when subjected to compression loads. Five different load sequences were applied to TA01 during testing and included four sub-critical load sequences, i.e., loading conditions that did not cause buckling or material failure, and one final load sequence to buckling and collapse. The sub-critical load sequences consisted of either uniform axial compression loading or combined axial compression and bending and the final load sequence subjected TA01 to uniform axial compression. Traditional displacement transducers and strain gages were used to monitor the test article response at nearly 300 locations and an advanced digital image correlation system was used to obtain low-speed and high-speed full-field displacement measurements of the outer surface of the test article. Overall, the test facility and test article performed as designed. In particular, the test facility successfully applied all desired load combinations to the test article and was able to test safely into the postbuckling range of loading, and the test article failed by global buckling. In addition, the test results correlated well with initial pretest predictions.

Hilburger, Mark W.↗

Use of an Internal Mercury-Argon Lamp for the Calibration of Raman Frequency in Large Raman Images of Astromaterials

Raman imaging is an emerging tool for the analysis of meteorites, as it is capable of describing mineralogy, carbon composition/speciation, and crystal orientation all within a petrographic context. Adequately examining the heterogeneous composition of a meteorite, while maintaining low laser powers needed to prevent damage to meteorite mineralogy and organics, often requires the collection of large Raman images with long collection times on the timescale of days. However, the frequency calibration of the Raman instrument/spectrometer drifts on long timescales resulting in low frequency precision for the Raman spectra comprising a large Raman image. This decrease in frequency precision can compromise the analysis of geological markers that can provide important information on a meteorite sample. We examine, in detail, the change in bandwidth and frequency of the Raman bands and Hg-Ar emission lines in our Raman images as a function of time and laboratory temperature. To overcome the drift in calibration, we utilize a commercial WITec Raman instrument with an internal Hg-Ar calibration lamp to individually calibrate each spectrum in the Raman image. Our instrument, known as “Ratatoskr”, uses a beam splitter in place of the customary mirror to facilitate collection of Hg-Ar calibration lines concurrent with Raman spectra. We show that using the internal calibration we can improve the frequency precision for the spectra in our Raman images from ~±0.15 cm(exp -1) to ~±0.05 cm(exp -1) for Raman spectra collected over multiple days. This is important as it improves measurements of mineral chemistry, latent strain, and other features that are dependent upon accurate peak position determination. We also examine the spectral signal-to-noise ratio needed to minimize the frequency error when fitting bands to Gaussian/Lorentzian profiles. We then use our results to suggest a general method for calibrating the frequency of Raman spectra in large Raman images.

Jakubek, Ryan S.↗

Wind Tunnel Measurements of the Wake of a Full-Scale UH-60A Rotor in Forward Flight

A full-scale UH-60A rotor was tested in the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel in May 2010. The test was designed to acquire a suite of measurements to validate state-of-the-art modeling tools. Measurements include blade airloads (from a single pressure-instrumented blade), blade structural loads (strain gages), rotor performance (rotor balance and torque measurements), blade deformation (stereo-photogrammetry), and rotor wake measurements (Particle Image Velocimetry (PIV) and Retro-reflective Backward Oriented Schlieren (RBOS)). During the test, PIV measurements of flow field velocities were acquired in a stationary cross-flow plane located on the advancing side of the rotor disk at approximately 90 deg rotor azimuth. At each test condition, blade position relative to the measurement plane was varied. The region of interest (ROI) was 4-ft high by 14-ft wide and covered the outer half of the blade radius. Although PIV measurements were acquired in only one plane, much information can be gleaned by studying the rotor wake trajectory in this plane, especially when such measurements are augmented by blade airloads and RBOS data. This paper will provide a comparison between PIV and RBOS measurements of tip vortex position and vortex filament orientation for multiple rotor test conditions. Blade displacement measurements over the complete rotor disk will also be presented documenting blade-to-blade differences in tip-path-plane and providing additional information for correlation with PIV and RBOS measurements of tip vortex location. In addition, PIV measurements of tip vortex core diameter and strength will be presented. Vortex strength will be compared with measurements of maximum bound circulation on the rotor blade determined from pressure distributions obtained from 235 pressure sensors distributed over 9 radial stations.

Wadcock, Alan J.↗

Test and model correlation of the atmospheric emission photometric imager fiberglass pedestal

The correlation is presented of the static loads testing and finite element modeling for the fiberglass pedestal used on the Atmospheric Emission Photometric Imaging (AEPI) experiment. This payload is to be launched in the space shuttle as part of the ATLAS-1 experiment. Strain gauge data from rosettes around the highly loaded base are compared to the same load case run for the Spacelab 1 testing done in 1981. Correlation of the model and test data was accomplished through comparison of the composite stress invariant using the expected flight loads for the ATLAS-1 mission. Where appropriate, the Tsai-Wu failure criteria was used in the development of the key margins of safety. Margins of safety are all positive for the pedestal and are reported.

Lee, H. M., III↗

The investigation of the mechanical properties of thermoviscoelastic material

An image moire method is used to determine Poisson's ratio for PMMA at different temperatures. A uniaxial tensile specimen is strained axially to a constant strain, and the lateral strain and the axial strain are monitored by a period photographic record. Simultaneous recording of the tensile stress yields the Young's modulus in relaxation and the corresponding Poisson effect. The test temperatures range from room temperature to 125 C. The data are then used to deduce the bulk relaxation moduli.

Knauss, W. G.↗

Plastid sedimentation kinetics in roots of wild-type and starch-deficient mutants of Arabidopsis

Sedimentation and movement of plastids in columella cells of the root cap were measured in seedlings of wild-type, a reduced starch mutant, and a starchless mutant of Arabidopsis. To assay for sedimentation, we used both linear measurements and the change of angle from the cell center as indices in vertical and reoriented plants with the aid of computer-assisted image analysis. Seedlings were fixed at short periods after reorientation, and plastid sedimentation correlated with starch content in the three strains of Arabidopsis. Amyloplasts of wild-type seedlings showed the greatest sedimentation, whereas plastids of the starchless mutant showed no significant sedimentation in the vertically grown and reoriented seedlings. Because previous research has shown that a full complement of starch is needed for full gravitropic sensitivity, this study correlates increased sensitivity with plastid sedimentation. However, although plastid sedimentation contributed to gravisensitivity, it was not required, because the gravitropic starchless mutant had plastids that did not sediment. This is the first study, to our knowledge, to measure plastid sedimentation in Arabidopsis roots after reorientation of seedlings. Taken together, the results of this study are consistent with the classic plastid-based and protoplast-based models of graviperception and suggest that multiple systems of perception exist in plant cells.

NASA Discipline Plant Biology↗

The soft x ray telescope for Solar-A

The Solar-A satellite being prepared by the Institute for Sapce and Astronautical Sciences (ISAS) in Japan is dedicated to high energy observations of solar flares. The Soft X Ray Telescope (SXT) is being prepared to provide filtered images in the 2 to 60 A interval. The flight model is now undergoing tests in the 1000 foot tunnel at MSFC. Launch will be in September 1991. Earlier resolution and efficiency tests on the grazing incidence mirror have established its performance in soft x rays. The one-piece, two mirror grazing incidence telescope is supported in a strain free mount separated from the focal plane assembly by a carbon-epoxy metering tube whose windings and filler are chosen to minimize thermal and hygroscopic effects. The CCD detector images both the x ray and the concentric visible light aspect telescope. Optical filters provide images at 4308 and 4700 A. The SXT will be capable of producing over 8000 of the smallest partial frame images per day, or fewer but larger images, up to 1024 x 1024 pixel images. Image sequence with two or more of the five x ray analysis filters, with automatic exposure compensation to optimize the charge collection by the CCD detector, will be used to provide plasma diagnostics. Calculations using a differential emission measure code were used to optimize filter selection over the range of emission measure variations and to avoid redundancy, but the filters were chosen primarily to give ratios that are monotonic in plasma temperature.

Brown, W. A.↗

Venus tectonics - Initial analysis from Magellan

The styles of lithospheric deformation, the inferred mechanical properties of the lithosphere, and their implications for the tectonic history of Venus are discussed on the basis of radar imaging and altimetry data from Magellan. Observations of the planet plains reveal a superposition of different episodes of deformation and volcanism, strain both distributed and concentrated into zones of extension and shortening, and features reflecting a crustal response to mantle dynamic processes. Lithospheric shortening and crustal thickening are represented by ridge belts and mountain belts. The latter show the evidence for extension and collapse both during and following crustal compression. Venus displays quasi-circular coronae and broad rises with linear rift zones, associated with significant volcanism. Large-offset strike-slip faults have not been observed, although horizontal shear is accommodated across broad zones of crustal shortening. On Venus strain is distributed across zones that are one to a few hundred kilometers wide, and separated by stronger and less deformed blocks hundreds of kilometers in width, as in actively deforming continental regions on earth.

Solomon, Sean C.↗

Evidence for exclusively inorganic formation of magnetite in Martian meteorite ALH84001

Magnetite crystals produced by terrestrial magnetotactic bacterium MV-1 are elongated on a [111] crystallographic axis, in a so-called truncated hexa-Octahedral shape. This morphology has been proposed to constitute a biomarker (i.e., formed only in biogenic processes). A subpopulation of magnetite crystals associated with carbonate globules in Martian meteorite ALH84001 is reported to have this morphology, and the observation has been taken as evidence for biological activity on Mars. In this study, we present evidence for the exclusively inorganic origin of [111]-elongated magnetite crystals in ALH84001. We report three-dimensional(3-D) morphologies for approx.1000 magnetite crystals extracted from: (1) thermal decomposition products of Fe-rich carbonate produced by inorganic hydrothermal precipitation in laboratory experiments; (2) carbonate globules in Martian meteoriteeALH84001; and (3) cells of magnetotactic bacterial strain MV-1. The 3-D morphologies were derived by fitting 3-D shape models to two-dimensional bright-field transmission-electron microscope (TEAM) images obtained at a series of viewing angles. The view down the {110} axes closest to the [111] elongation axis of magnetite crystals ([111]x{110) not equal to 0) provides a 2-D projection that uniquely discriminates among the three [111]-elongated magnetite morphologies found in these samples: [111]-elongated truncated hexaoctahedron ([111]-THO), [111]-elongated cubo-octahedron ([111]-ECO), and [111]-elongated simple octahedron ([111]-ESO). All [111] -elongated morphologies are present in the three types of sample, but in different proportions. In the ALH84001 Martian meteorite and in our inorganic laboratory products, the most common [111]-elongated magnetite crystal morphology is [111]-ECO. In contrast, the most common morphology for magnetotactic bacterial strain MV-1 is [111]-THO. These results show that: (1) the morphology of [111]-elongated magnetite crystals associated with the carbonate globules in Martian meteorite ALH84001 is replicated by an inorganic process; and (2) the most common crystal morphology for biogenic (MV-1) magnetite is distinctly different from that in both ALH84001 and our inorganic laboratory products. Therefore, [111]-elongated magnetite crystals in ALH84001 do not constitute, as previously claimed, a robust biosignature and, in fact, an exclusively inorganic origin for the magnetite is fully consistent with our results. Furthermore, the inorganic synthesis method, i.e., the thermal decomposition of hydrothermally precipitated Fe-rich carbonate, is a process analogue for formation of the magnetite on Mars. Namely, precipitation of carbonate globules from carbonate-rich hydrothermal solutions followed at some later time by a thermal pulse, perhaps in association with meteoritic impact or volcanic processes on the Martian surface.

Golden, D. C.↗

Chromatically corrected virtual image visual display

An in-line, three element, large diameter, optical display lens is disclosed which has a front convex-convex element, a central convex-concave element, and a rear convex-convex element. The lens, used in flight simulators, magnifies an image presented on a television monitor and, by causing light rays leaving the lens to be in essentially parallel paths, reduces eye strain of the simulator operator.

Kahlbaum, W. M., Jr.↗

Flight motor set 360T004 (STS-30R). Volume 1: System overview

The fourth NASA space shuttle flight incorporating redesigned solid rocket motors began on 4 May 1989. The flight motors were designated 360Q004A (left-hand) and 360H004B (right-hand); the mission was designated STS-30R. Overall engine performance was excellent. The low sample rate data that was available showed exceptional propulsion performance. All ballistic and mass property parameters closely matched the predicted values and were well within the required contract end item specification levels that could be assessed. No strain, vibration, or aft skirt heating environments could be addressed due to developmental flight instrumentation deletion. Infrared readings from the shuttle thermal imager were considered very good when compared with ground environment instrumentation readings taken during both the aborted and the actual countdowns. However, hand-held infrared gun reading/ground environment instrumentation comparisons were considered poor during both countdowns, with the exception of the T - 3 hour timeframe during the actual launch. Postflight inspection again verified superior performance of the insulation, phenolics, metal parts, and seals. All combustion gas was contained by the insulation in the field and case-to-nozzle joints. Inadequate parachute performance on the left-hand booster caused high splashdown loads, which resulted in a displaced nozzle and factory joint weatherseal unbond anomalies. Recommendations were made concerning improved thermal modeling and instruments. The rationale for these recommendations, the dispositions of all anomalies, and complete result details are given.

Ricks, Glenn A.↗

A Dual-Line Detection Rayleigh Scattering Diagnostic Technique for the Combustion of Hydrocarbon Fuels and Filtered UV Rayleigh Scattering for Gas Velocity Measurements

Non-intrusive techniques for the dynamic measurement of gas flow properties such as density, temperature and velocity, are needed in the research leading to the development of new generation high-speed aircraft. Accurate velocity, temperature and density data obtained in ground testing and in-flight measurements can help understand the flow physics leading to transition and turbulence in supersonic, high-altitude flight. Such non-intrusive measurement techniques can also be used to study combustion processes of hydrocarbon fuels in aircraft engines. Reliable, time and space resolved temperature measurements in various combustor configurations can lead to a better understanding of high temperature chemical reaction dynamics thus leading to improved modeling and better prediction of such flows. In view of this, a research program was initiated at Polytechnic University's Aerodynamics Laboratory with support from NASA Lewis Research Center through grants NAG3-1301 and NAG3-1690. The overall objective of this program has been to develop laser-based, non-contact, space- and time-resolved temperature and velocity measurement techniques. In the initial phase of the program a ND:YAG laser-based dual-line Rayleigh scattering technique was developed and tested for the accurate measurement of gas temperature in the presence of background laser glare. Effort was next directed towards the development of a filtered, spectrally-resolved Rayleigh/Mie scattering technique with the objective of developing an interferometric method for time-frozen velocity measurements in high-speed flows utilizing the uv line of an ND:YAG laser and an appropriate molecular absorption filter. This effort included both a search for an appropriate filter material for the 266 nm laser line and the development and testing of several image processing techniques for the fast processing of Fabry-Perot images for velocity and temperature information. Finally, work was also carried out for the development of a new laser-based strain-rate and vorticity technique for the time-resolved measurement of vorticity and strain-rates in turbulent flows.

Otugen, M. Volkan↗

Both necrosis and apoptosis contribute to HIV-1-induced killing of CD4 cells

BACKGROUND: Data currently available on HIV-1-induced cytopathology is unclear regarding the mechanism of cell killing. OBJECTIVE: To clarify the extent to which apoptosis or necrosis is involved in HIV-1-induced cell death in view of conflicting existing data. METHODS: T lymphoblastoid cells or peripheral blood mononuclear cells were infected by various strains of HIV-1 and the numbers of apoptotic or necrotic cells were quantified at various times after infection using video-image analysis techniques; the results were compared with the amount of fragmented DNA using a quantitative method. Measurement of mitochondrial transmembrane potential (deltapsi(m)) and intracellular calcium concentrations [Ca2+]i was performed with fluorescent probes and fluorescence concentration analysis (FCA). RESULTS: Although lymphoblastoid and monocytoid cells acutely infected by HIV-1 had increased levels of fragmented DNA, a marker of apoptotic cell death, few (<12%) had condensed chromatin and fragmented nuclei, the morphological features of apoptosis. The predominant alterations in acutely infected cells were distended endoplasmic reticulum and abnormal mitochondria; these ultrastructural changes are consistent with necrosis, although some infected cells simultaneously displayed features of both necrosis and apoptosis. Viability of cells persistently infected by HIV-1 was only minimally reduced from that of uninfected cells. This reduction was accounted for by an increased propensity of the persistently infected cells to die by apoptosis. Alterations in [Ca2+]i and deltapsi(m) occurred in both acutely and persistently infected cells. CONCLUSION: Both necrosis and apoptosis contribute to HIV-1-induced killing of CD4 cells.

Non-NASA Center↗

NASA Tech Briefs, March 2009

Topics covered include: Improved Instrument for Detecting Water and Ice in Soil; Real-Time Detection of Dust Devils from Pressure Readings; Determining Surface Roughness in Urban Areas Using Lidar Data; DSN Data Visualization Suite; Hamming and Accumulator Codes Concatenated with MPSK or QAM; Wide-Angle-Scanning Reflectarray Antennas Actuated by MEMS; Biasable Subharmonic Membrane Mixer for 520 to 600 GHz; Hardware Implementation of Serially Concatenated PPM Decoder; Symbolic Processing Combined with Model-Based Reasoning; Presentation Extensions of the SOAP; Spreadsheets for Analyzing and Optimizing Space Missions; Processing Ocean Images to Detect Large Drift Nets; Alternative Packaging for Back-Illuminated Imagers; Diamond Machining of an Off-Axis Biconic Aspherical Mirror; Laser Ablation Increases PEM/Catalyst Interfacial Area; Damage Detection and Self-Repair in Inflatable/Deployable Structures; Polyimide/Glass Composite High-Temperature Insulation; Nanocomposite Strain Gauges Having Small TCRs; Quick-Connect Windowed Non-Stick Penetrator Tips for Rapid Sampling; Modeling Unsteady Cavitation and Dynamic Loads in Turbopumps; Continuous-Flow System Produces Medical-Grade Water; Discrimination of Spore-Forming Bacilli Using spoIVA; nBn Infrared Detector Containing Graded Absorption Layer; Atomic References for Measuring Small Accelerations; Ultra-Broad-Band Optical Parametric Amplifier or Oscillator; Particle-Image Velocimeter Having Large Depth of Field; Enhancing SERS by Means of Supramolecular Charge Transfer; Improving 3D Wavelet-Based Compression of Hyperspectral Images; Improved Signal Chains for Readout of CMOS Imagers; SOI CMOS Imager with Suppression of Cross-Talk; Error-Rate Bounds for Coded PPM on a Poisson Channel; Biomorphic Multi-Agent Architecture for Persistent Computing; and Using Covariance Analysis to Assess Pointing Performance.

Source record↗

Polarized-cathodoluminescence study of uniaxial and biaxial stress in GaAs/Si

The strain-induced splitting of the heavy-hole (hh) and light-hole (lh) valence bands for 4-microns thick GaAs/Si is examined on a microscopic scale using linear polarized-cathodoluminescence imaging and spectroscopy. The energies and intensities of the hh- and lh-exciton luminescence are quantitatively analyzed to determine spatial variations in the stress tensor. The results indicate that regions near and far from the microcracks are primarily subject to uniaxial and biaxial tensile stresses, respectively. The transition region where biaxial stress gradually converts to uniaxial stress is analyzed, and reveals a mixing of lh and hh characters in the strain-split bands.

Rich, D. H.↗

Development and Characterization of Embedded Sensory Particles Using Multi-Scale 3D Digital Image Correlation

A method for detecting fatigue cracks has been explored at NASA Langley Research Center. Microscopic NiTi shape memory alloy (sensory) particles were embedded in a 7050 aluminum alloy matrix to detect the presence of fatigue cracks. Cracks exhibit an elevated stress field near their tip inducing a martensitic phase transformation in nearby sensory particles. Detectable levels of acoustic energy are emitted upon particle phase transformation such that the existence and location of fatigue cracks can be detected. To test this concept, a fatigue crack was grown in a mode-I single-edge notch fatigue crack growth specimen containing sensory particles. As the crack approached the sensory particles, measurements of particle strain, matrix-particle debonding, and phase transformation behavior of the sensory particles were performed. Full-field deformation measurements were performed using a novel multi-scale optical 3D digital image correlation (DIC) system. This information will be used in a finite element-based study to determine optimal sensory material behavior and density.

Cornell, Stephen R.↗