NASA Redox cell stack shunt current, pumping power, and cell performance tradeoffs

The NASA Redox energy storage system is under active technology development. The hardware undergoing laboratory testing is either 310 sq. cm. or 929 sq. cm. (0.33 sq. ft. or 1.0 sq. ft. per cell active area with up to 40 individual cells connected to make up a modular cell stack. This size of hardware allows rather accurate projections to be made of the shunt power/pump power tradeoffs. The modeling studies that were completed on the system concept are reviewed along with the approach of mapping the performance of Redox cells over a wide range of flow rates and depths of discharge of the Redox solutions. Methods are outlined for estimating the pumping and shunt current losses for any type of cell and stack combination. These methods are applicable to a variety of pumping options that are present with Redox systems. The results show that a fully developed Redox system has acceptable parasitic losses when using a fixed flow rate adequate to meet the worst conditions of current density and depth of discharge. These losses are reduced by about 65 percent if variable flow schedules are used. The exact value of the overall parasitics will depend on the specific system requirements of current density, voltage limits, charge, discharge time, etc.

Hagedorn, N.↗

Inter-layered clay stacks in Jurassic shales

Scanning electron microscopy in the backscattered electron mode is used together with energy-dispersive X-ray microanalysis to show that Lower Jurassic shales from the North Sea Basin contain large numbers of clay mineral stacks up to 150 microns in size. Polished shale sections are examined to determine the size, shape orientation, textural relationships, and internal compositional variations of the clays. Preliminary evidence that the clay stacks are authigenic, and may have formed at shallow burial depths during early diagenesis, is presented.

Pye, K.↗

Evaluation of gas cooling for pressurized phosphoric acid fuel cell stacks

Gas cooling is a more reliable, less expensive and a more simple alternative to conventional liquid cooling for heat removal from the phosphoric acid fuel cell (PAFC). The feasibility of gas cooling has already been demonstrated in atmospheric pressure stacks. This paper presents theoretical and experimental investigation of gas cooling for pressurized PAFC. Two approaches to gas cooling, Distributed Gas Cooling (DIGAS) and Separated Gas Cooling (SGC) were considered, and a theoretical comparison on the basis of cell performance indicated SGC to be superior to DIGAS. The feasibility of SGC was experimentally demonstrated by operating a 45-cell stack for 700 hours at pressure, and determining thermal response and the effect of other related parameters.

Farooque, M.↗

Diffusion welding of Cassegrainian concentrator cell stack assemblies

Development of a procedure to join the components of the Cassegrainian concentrator photovoltaic cell stack assembly was studied. Diffusion welding was selected as the most promising process, and was concentrated on exclusively. All faying surfaces were coated with silver to promote welding. The first phase of the study consisted of developing the relationship between process parameters and joint strength using silver plated steel samples and an isostatic pressure system. In the second phase, mockups of the cell stack assembly were welded in a hot isostatic press. Excellent joint strength was achieved with parameters of 350 C and 10 ksi, but the delicate GaAs component could not survive the welding cycle without cracking. The tendency towards cracking was found to be affected by both temperature and pressure. Further work will be required in the future to solve this problem.

Gangl, K. J.↗

Magnetically suspended stacks for inertial energy storage flywheel

A magnetically suspended flywheel stack based on a 'pancake' magnetic bearing stack is proposed for a 500 watt-hour energy storage system. Backup ball bearings in the system configuration both prevent damage to the system whenever there is a loss of magnetic suspension due to excessive outside disturbances, and insure that the fywheel stays within the linear control range. Design tools to investigate the performance of the control system and the magnetic circuits are also discussed.

Anand, Davinder K.↗

A fractographic investigation of the influence of stacking sequence on the strength of notched laminated composites

The fracture behavior of T300/5208 CFRP laminate panels with 12 different combinations of ply orientation and stacking sequence is investigated experimentally, using optical microscopy, SEM, and X-ray radiography to characterize the notch-tip damage zones and fracture surfaces of center-cracked tension specimens subjected to tensile loading at constant crosshead displacement rate 20 micron/s. The results are presented graphically and analyzed in detail. Significant differences in notched strength are found for different ply fiber orientations and stacking sequences; the laminates with few major delaminations had a greater percentage of fracture due to broken fibers and also higher notched strength.

Harris, Charles E.↗

The effect of rotor dynamics on a flywheel stack energy storage system

The paper presents a dynamic analysis of a magnetic-bearing stack system consisting of a single flywheel supported by two magnetic bearings. Real-time plots from a computer simulation are used to show the effect of dynamic coupling on the torque response, and the frequency response is used to determine the resonance frequencies of the stack system. It is found that system stability depends on the flywheel speed.

Jayaraman, Chaitanya P.↗

Stacking-sequence optimization for buckling of laminated plates by integer programming

Integer-programming formulations for the design of symmetric and balanced laminated plates under biaxial compression are presented. Both maximization of buckling load for a given total thickness and the minimization of total thickness subject to a buckling constraint are formulated. The design variables that define the stacking sequence of the laminate are zero-one integers. It is shown that the formulation results in a linear optimization problem that can be solved on readily available software. This is in contrast to the continuous case, where the design variables are the thicknesses of layers with specified ply orientations, and the optimization problem is nonlinear. Constraints on the stacking sequence such as a limit on the number of contiguous plies of the same orientation and limits on in-plane stiffnesses are easily accommodated. Examples are presented for graphite-epoxy plates under uniaxial and biaxial compression using a commercial software package based on the branch-and-bound algorithm.

Haftka, Raphael T.↗

Stacking-sequence optimization for buckling of laminated plates by integer programming

Integer-programming formulations for the design of symmetric and balanced laminated plates under biaxial compression are presented. Both maximization of buckling load for given total thickness, and the minimization of total thickness subject to a buckling constraint are formulated. The design variables that define the stacking sequence of the laminate are zero-one integers. It is shown that the formulation results in a linear optimization problem that can be solved on readily aviable software. Constraints on the stacking sequence such as a limit on the number of contiguous plies of the same orientation and limits on in-plane stiffnesses are easily accommodated. Examples are presented for graphite-epoxy plates under uniaxial and biaxial compression using a commercial software package based on the branch-and-bound algorithm.

Haftka, Raphael T.↗

Improved Stacking Of Vent Lines Of A Parachute

New arrangement provides nearly uniform distribution of load among vent lines and points of attachment of vent lines to vent band. New method eliminates large stack height between first and last lines and, just as important, maintains constant stack height between any two adjacent vent lines around entire vent. Distributes loads at vent band more nearly evenly among lines. Adverse concentrations of loads in vent band reduced.

Hengel, John E.↗

Stacking sequence optimization of simply supported laminates with stability and strain constraints

An integer programming formulation for the design of symmetric and balanced rectangular composite laminates with simply supported boundary conditions subject to buckling and strain constraints is presented. The design variables that define the stacking sequence of the laminate are ply-identity zero-one integers. The buckling constraint is linear in terms of the ply-identity design variables, but strains are nonlinear functions of these variables. A linear approximation is developed for the strain constraints so that the problem can be solved by sequential linearization using the branch and bound algorithm. Examples of graphite-epoxy plates under biaxial compression are presented. Optimum stacking sequences obtained using the linear approximation are compared with global optimum designs obtained using a genetic search procedure.

Nagendra, S.↗

Measurements of the effects of thermal contact resistance on steady state heat transfer in phosphoric-acid fuel cell stack

The influence of the thermal contact resistance on the heat transfer between the electrode plates, and the cooling system plate in a phosphoric-acid fuel-cell stack was experimentally investigated. The investigation was conducted using a set-up that simulates the operating conditions prevailing in a phosphoric acid fuel-cell stack. The fuel-cell cooling system utilized three types of coolants, water, engine oil, and air, to remove excess heat generated in the cell electrode and to maintain a reasonably uniform temperature distribution in the electrode plate. The thermal contact resistance was measured as a function of pressure at the interface between the electrode plate and the cooling system plate. The interface pressure range was from 0 kPa to 3448 kPa, while the Reynolds number for the cooling limits varied from 15 to 79 for oil, 1165 to 6165 for water, and 700 to 6864 for air. Results showed that increasing the interface pressure resulted in a higher heat transfer coefficient.

Abdul-Aziz, Ali↗

Dummy Cell Would Improve Performance Of Fuel-Cell Stack

Interposition of dummy cell between stack of alkaline fuel cells and accessory section of fuel-cell powerplant proposed to overcome operational deficiencies plaguing end-most active cell. Cell in combination with additional hydrogen/coolant separator plate keeps end cell warmer and drier. End cell 96th in stack of fuel cells.

Suljak, G. T.↗

Effects of the cooling system parameters on heat transfer and performance of the PAFC stack during transient operation

An experimental investigation for the effects of transient operation of a phosphoric acid fuel-cell stack on heat transfer and temperature distribution in the electrodes has been conducted. The proposed work utilized the experimental setup with modifications, which was designed and constructed under NASA Contract No. NCC-3-17(5). The experimental results obtained from this investigation and the mathematical model obtained under NASA Contract No. NCC3-17(4) after modifications, were utilized to develop mathematical models for transient heat transfer coefficient and temperature distribution in the electrode and to evaluate the performance of the cooling - system under unsteady state conditions. The empirical formulas developed were then implemented to modifying the developed computer code. Two incompressible coolants were used to study experimentally the effect of the thermophysical properties of the cool-ants on the transient heat transfer coefficient and the thermal contact resistance during start-up and shut-down processes. Coolant mass flow rates were verified from 16 to 88.2 Kg/hr during the transient process when the electrical power supply was gradually increased or decreased in the range (O to 3000 W/sq m). The effect of the thermal contact resistance with a range of stack pressure from O to 3500 KPa was studied.

Ridha, Rabi M. J.↗

Interconnections For Stacked Parallel Computer Modules

Concept for interconnecting modules in parallel computers leads to cheaper, smaller, lighter, lower-power computing systems for aerospace, industrial, business, and consumer applications. Computer modules stacked and interconnected in various configurations. Connections among stacks controlled by switching within gateways and/or by addresses on buses.

Johannesson, Richard T.↗

Multi-Line Gamma-Ray Spectrometer Performance of a Si(Li) Detector Stack

Experimental data is presented which for the first time displays multi-line spectrometer performance of a Si(Li) detector stack at elevated temperature. The stack consists of four elements, each with a 2 cm diameter active area. Ba-133 and Ag-110m spectra are obtained using various techniques to enhance the peak-to-background ratio. Spectral data are shown as a function of temperature (94 K less than or equal to T less than or equal to 230 K) using optimized peak shaping.

Hubbard, G. Scott↗

Multi-Line Gamma-Ray Spectrometer Performance of a Si(Li) Detector Stack

Experimental data is presented which for the first time displays multi-line spectrometer performance of a Si(Li) detector stack at elevated temperature. The stack consists of four elements, each with a 2 cm diameter active area. Ba-133 and Ag-110m spectra are obtained using various techniques to enhance the peak-to-background ratio. Spectral data are shown as a function of temperature (94 K less than or = T less than or = 230 K) using optimized peak shaping.

Hubbard, G. Scott↗