At least 145 records · Page 8

Multivariate analysis of gamma spectra to characterize used nuclear fuel

Abstract—The Multi-Isotope Process (MIP) Monitor provides an efficient approach to monitoring the process conditions in used nuclear fuel reprocessing facilities to support process verification and validation. The MIP Monitor applies multivariate analysis to gamma spectroscopy of reprocessing streams in order to detect small changes in the gamma spectrum, which may indicate changes in process conditions. This research extends the MIP Monitor by characterizing a used fuel sample after initial dissolution according to the type of reactor of origin (pressurized or boiling water reactor), initial enrichment, burn up, and cooling time. Simulated gamma spectra were used to develop and test three fuel characterization algorithms. The classification and estimation models employed are based on the partial least squares regression (PLS) algorithm. A PLS discriminate analysis model was developed which perfectly classified reactor type. Locally weighted PLS models were fitted on-the-fly to estimate continuous fuel characteristics. Burn up was predicted within 0.1% root mean squared percent error (RMSPE) and both cooling time and initial enrichment within approximately 2% RMSPE. This automated fuel characterization can be used to independently verify operator declarations of used fuel characteristics and inform the MIP Monitor anomaly detection routines at later stages of the fuel reprocessing stream to improve sensitivity to changes in operational parameters and material diversions.

Multivariate Analysis for Characterization of Used↗

Coherent-Radiation Spectroscopy of Few-Femtosecond Electron Bunches Using a Middle-Infrared Prism Spectrometer

Modern, high-brightness electron beams such as those from plasma wakefield accelerators and free-electron laser linacs continue the drive to ever-shorter bunch durations. In low-charge operation ( ~ 20 pC ), bunches shorter than 10 fs are reported at the Linac Coherent Light Source (LCLS). Though suffering from a loss of phase information, spectral diagnostics remain appealing as compact, low-cost bunch duration monitors suitable for deployment in beam dynamics studies and operations instrumentation. Progress in middle-infrared (MIR) imaging has led to the development of a single-shot, MIR prism spectrometer to characterize the corresponding LCLS coherent beam radiation power spectrum for few-femtosecond scale bunch length monitoring. In this Letter, we report on the spectrometer installation as well as the temporal reconstruction of 3 to 60 fs-long LCLS electron bunch profiles using single-shot coherent transition radiation spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Continuous whole-system monitoring toward rapid understanding of production HPC applications and systems

A detailed understanding of HPC applications’ resource needs and their complex interactions with each other and HPC platform resources are critical to achieving scalability and performance. Such understanding has been difficult to achieve because typical application profiling tools do not capture the behaviors of codes under the potentially wide spectrum of actual production conditions and because typical monitoring tools do not capture system resource usage information with high enough fidelity to gain sufficient insight into application performance and demands. In this paper we present both system and application profiling results based on data obtained through synchronized system wide monitoring on a production HPC cluster at Sandia National Laboratories (SNL). We demonstrate analytic and visualization techniques that we are using to characterize application and system resource usage under production conditions for better understanding of application resource needs. Furthermore, our goals are to improve application performance (through understanding application-to-resource mapping and system throughput) and to ensure that future system capabilities match their intended workloads.

97 MATHEMATICS AND COMPUTING↗

Beam transport and monitoring for laser plasma accelerators

The controlled transport and imaging of relativistic electron beams from laser plasma accelerators (LPAs) are critical for their diagnostics and applications. Here we present the design and progress in the implementation of the transport and monitoring system for an undulator based electron beam diagnostic. Miniature permanent-magnet quadrupoles (PMQs) are employed to realize controlled transport of the LPA electron beams, and cavity based electron beam position monitors for non-invasive beam position detection. Also presented is PMQ calibration by using LPA electron beams with broadband energy spectrum. The results show promising performance for both transporting and monitoring. With the proper transport system, XUV-photon spectra from THUNDER will provide the momentum distribution of the electron beam with the resolution above what can be achieved by the magnetic spectrometer currently used in the LOASIS facility.

43 PARTICLE ACCELERATORS↗

Fatigue of extracted lead zirconate titanate multilayer actuators under unipolar high field electric cycling

Testing of large prototype lead zirconate titanate (PZT) stacks presents substantial technical challenges to electronic testing systems, so an alternative approach that uses subunits extracted from prototypes has been pursued. Extracted 10-layer and 20-layer plate specimens were subjected to an electric cycle test under an electric field of 3.0/0.0 kV/mm, 100 Hz to 10{sup 8} cycles. The effects of measurement field level and stack size (number of PZT layers) on the fatigue responses of piezoelectric and dielectric coefficients were observed. On-line monitoring permitted examination of the fatigue response of the PZT stacks. The fatigue rate (based on on-line monitoring) and the fatigue index (based on the conductance spectrum from impedance measurement or small signal measurement) were developed to quantify the fatigue status of the PZT stacks. The controlling fatigue mechanism was analyzed against the fatigue observations. The data presented can serve as input to design optimization of PZT stacks and to operation optimization in critical applications, such as piezoelectric fuel injectors in heavy-duty diesel engines.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using Higher Order Modes in Superconducting Accelerating Cavities for Beam Monitoring

Dipole modes have been shown to be successful diagnostics for the beam position in superconducting accelerating cavities at the Free Electron Laser in Hamburg (FLASH) facility at DESY. By help of downmixing electronics the signals from the two higher order mode (HOM) couplers mounted on each cavity are monitored. The calibration, based on singular value decomposition, is more complicated than in standard position monitors. Position like signals based on this calibration are currently being in the process of being included in the control system. A second setup based on digitizing the spectrum from the HOM couplers has been used for monitoring monopole modes. The beam phase with respect to the RF has been thus monitored. The position calibration measurements and phase monitoring made at the FLASH are presented.

43 PARTICLE ACCELERATORS↗

Relationship between β-relaxation and structural stability of lysozyme: Microscopic insight on thermostabilization mechanism by trehalose from Raman spectroscopy experiments

Raman investigations were carried out in the low-frequency and amide I regions on lysozyme aqueous solutions in absence and presence of trehalose. Raman spectroscopy gives the unique opportunity to analyze the protein and solvent dynamics in the low-frequency range while monitoring the unfolding process by capturing the spectrum of the amide I band. From the analysis of the quasielastic intensity, a dynamic change is firstly observed in a highly hydrated protein, around 70 °C, and interpreted in relation with the denaturation mechanism of the protein. The use of heavy water and partly deuterated trehalose gives clear information on protein–trehalose interactions in the native state of lysozyme (at room temperature) and during the thermal denaturation process of lysozyme. At room temperature, it was found that trehalose is preferentially excluded from the protein surface, and has a main effect on the tetrahedral local order of water molecules corresponding to a stiffening of the H-bond network in the solvent. The consequence is a significant reduction of the amplitude of fast relaxational motions, inducing a less marked dynamic transition shifted toward the high temperatures. Upon heating, interaction between trehalose and lysozyme is detected during the solvent penetration within the protein, i.e., while the native globular state softens into a molten globule (MG) state. Addition of trehalose reduces the protein flexibility in the MG state, improving the structural stability of the protein, and inhibiting the protein aggregation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of internal dark current in a 17 GHz accelerator structure with an elliptical sidewall

A 17 GHz single cell, standing wave, copper accelerator structure with an axisymmetric elliptical central cell sidewall was tested for internal and downstream dark current as a function of gradient up to 93 MV/m. The elliptical sidewall was predicted to suppress the internal dark current and the lower order multipactor modes as compared with a previously tested structure having a straight sidewall. During the conditioning phase of the elliptical sidewall structure, strong internal dark current generated by an N = 1 multipactor mode was observed at gradients in the 10 to 20 MV/m range. After conditioning with 2.2x10^5 pulses to 93 MV/m, the N = 1 mode was completely suppressed and no multipactor resonances were observed. The internal dark current was reduced to a comparatively low level, much smaller than in the previously studied, straight sidewall structure, in good agreement with simulations. The energy spectrum of the electrons colliding with the sidewall was measured using an isolated side dark current monitor and a bias voltage. As the conditioning progressed, the electron energy spectrum showed an increase in the concentration of lower energy electrons, also in good agreement with simulations. Studies of internal dark current may help to understand the rf conditioning and ultimate performance of high gradient accelerator structures.

43 PARTICLE ACCELERATORS↗

Laser‐Induced Nanodroplet Injection and Reconfigurable Double Emulsions with Designed Inner Structures

Abstract Microfabrication of complex double emulsion droplets with controlled substructures, which resemble biological cells, is an important but a highly challenging subject. Here, a new approach is proposed based on laser‐induced injection of water nanodroplets into a liquid crystal (LC) drop. In contrast to the conventional top‐down microfluidic fabrication, this method employs a series of bottom‐up strategies such as nanodroplet injection, spontaneous and assisted coalescence, elastically driven actuation, and self‐assembly. Each step is controlled precisely by adjusting the laser beam, interfacial tension, and its gradients, surface anchoring, and elasticity of the LC. Whispering gallery mode illumination is used to monitor the injection of droplets. A broad spectrum of double emulsions with a predesigned hierarchical architecture is fabricated and reconfigured by temperature, laser‐induced coalescence, and injection. The proposed bottom‐up method to produce customized microemulsions that are responsive to environmental cues can be used in the development of drug delivery systems, biosensors, and functional soft matter microstructures.

42 ENGINEERING↗

Effect of electron irradiation on carrier removal rate in silicon and silicon carbide with 4H modification

Comparative study of the effect of successive (up to fluences of 3 x 10{sup 16} cm{sup -2}) irradiation with 900 keV electrons of samples made of FZ-Si and 4H-SiC (CVD) has been performed for the first time. Measurements on initial and irradiated samples were made using the van der Pauw method for silicon and the capacitance-voltage technique at a frequency of 1 kHz for silicon carbide. In addition, the spectrum of the defect levels introduced was monitored by the DLTS method for SiC. The carrier removal and defect introduction rates were determined for the two materials. It was found that the rates of defect introduction into FZ-Si and 4 H-SiC (CVD) are close to eachy other ({approx}0.1 cm{sup -1}), which is largely due to the almost identical threshold energies of defect generation.

36 MATERIALS SCIENCE↗

High-performance and scalable on-chip digital Fourier transform spectroscopy

Abstract On-chip spectrometers have the potential to offer dramatic size, weight, and power advantages over conventional benchtop instruments for many applications such as spectroscopic sensing, optical network performance monitoring, hyperspectral imaging, and radio-frequency spectrum analysis. Existing on-chip spectrometer designs, however, are limited in spectral channel count and signal-to-noise ratio. Here we demonstrate a transformative on-chip digital Fourier transform spectrometer that acquires high-resolution spectra via time-domain modulation of a reconfigurable Mach-Zehnder interferometer. The device, fabricated and packaged using industry-standard silicon photonics technology, claims the multiplex advantage to dramatically boost the signal-to-noise ratio and unprecedented scalability capable of addressing exponentially increasing numbers of spectral channels. We further explore and implement machine learning regularization techniques to spectrum reconstruction. Using an ‘elastic-D 1 ’ regularized regression method that we develop, we achieved significant noise suppression for both broad (>600 GHz) and narrow (<25 GHz) spectral features, as well as spectral resolution enhancement beyond the classical Rayleigh criterion.

47 OTHER INSTRUMENTATION↗

High-energy X-ray detection of G359.89–0.08 (SGR A–E): Magnetic flux tube emission powered by cosmic rays?

We report the first detection of high-energy X-ray (E > 10 keV) emission from the Galactic center non-thermal filament G359.89–0.08 (Sgr A–E) using data acquired with the Nuclear Spectroscopic Telescope Array (NuSTAR). The bright filament was detected up to ∼50 keV during a NuSTAR Galactic center monitoring campaign. The featureless power-law spectrum with a photon index Γ ≈ 2.3 confirms a non-thermal emission mechanism. The observed flux in the 3-79 keV band is F{sub X} = (2.0 ± 0.1) × 10{sup –12} erg cm{sup –2} s{sup –1}, corresponding to an unabsorbed X-ray luminosity L{sub X} = (2.6 ± 0.8) × 10{sup 34} erg s{sup –1} assuming a distance of 8.0 kpc. Based on theoretical predictions and observations, we conclude that Sgr A–E is unlikely to be a pulsar wind nebula (PWN) or supernova remnant-molecular cloud (SNR-MC) interaction, as previously hypothesized. Instead, the emission could be due to a magnetic flux tube which traps TeV electrons. We propose two possible TeV electron sources: old PWNe (up to ∼100 kyr) with low surface brightness and radii up to ∼30 pc or MCs illuminated by cosmic rays (CRs) from CR accelerators such as SNRs or Sgr A*.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of electron irradiation on carrier removal rate in silicon and silicon carbide with 4H modification

Comparative study of the effect of successive (up to fluences of 3 Multiplication-Sign 10{sup 16} cm{sup -2}) irradiation with 900 keV electrons of samples made of FZ-Si and 4H-SiC (CVD) has been performed for the first time. Measurements on initial and irradiated samples were made using the van der Pauw method for silicon and the capacitance-voltage technique at a frequency of 1 kHz for silicon carbide. In addition, the spectrum of the defect levels introduced was monitored by the DLTS method for SiC. The carrier removal and defect introduction rates were determined for the two materials. It was found that the rates of defect introduction into FZ-Si and 4 H-SiC (CVD) are close to eachy other ({approx}0.1 cm{sup -1}), which is largely due to the almost identical threshold energies of defect generation.

36 MATERIALS SCIENCE↗

A study of the cosmic sources of hard X-rays

An actively-shielded, high-energy X-ray telescope was launched onboard OSO-8 on 21 June 1975. The primary objectives of this experiment are the measurements of the energy spectrum of discrete cosmic X-ray sources in the range 20 keV to 3 MeV and of the temporal variations in the intensity of each source detected with a time resolution of 0.3 msec. This detector provides the highest duty factor and the finest time resolution of any of its kind for observations over a period of up to 10 days. The background spectrum of this detector in orbit was monitored continuously since shortly after launch. The minimum detectable source strength is estimated to be between 10,000 and 100,000 photons/sq-cm-sec keV, limited primary by the effects of induced radioactivity. From 16 July through 18 July 1975, the X-ray binary, Cen X-3, was observed with the hard X-ray telescope.

Dennis, B. R.↗

Mass Spectrometer for Airborne Micro-Organisms

Bacteria and other micro-organisms identified continously with aid of new technique for producing samples for mass spectrometer. Technique generates aerosol of organisms and feeds to spectrometer. Given species of organism produces characteristic set of peaks in mass spectrum and thereby identified. Technique useful for monitoring bacterial makeup in environmental studies and in places where cleanliness is essential, such as hospital operating rooms, breweries, and pharmaceutical plants.

Sinha, M. P.↗

Australian radio observations of SN1987A - A progress report

Regular monitoring of SN 1987A in the radio spectrum is being conducted at a number of Australian observatories. Although no emission is detectable at present, a VLBI network has been established to map a possible major outburst at high resolution.

Reynolds, John E.↗

Comparison of MGII and CIV emission lines in NGC5548

Results are presented of a cross-correlation analysis in which the Seyfert galaxy NGC 5548 was monitored in the UV portion of its spectrum every 4 d for an 8-mo period by an international collaborative effort using the IUE satellite. The analysis shows that the CIV 1550-A line correlates with the underlying continuum with a time delay of about 10 d. A similar analysis for the MgII 2798-A line yields a much broader peak and a delay of about 50 +/- 20 d. Thus the MgII line emitting gas appears to be about 5 times more distant from the central source. The MgII and CIV profiles in this series of spectra are compared on the same velocity scale. The two lines are quite similar on the red side of the profile, with the CIV more extended on the blue side. The overall width of the CIV is as much as 40 percent larger, but it is definitely not larger by a factor or two or more. It is concluded that the motion of the broad line emitting gas is not dominated by the gravitational influence of a central massive object.

Ptak, R.↗

Atlas 2 Animation

The Atmospheric Laboratory for Applications and Science-2 (ATLAS-2), was designed to collect data on the relationship between the sun's energy output and Earth's middle atmosphere and how these factors affect the ozone layer. The ATLAS-2 flew on the Space Shuttle Discovery's mission SST-56, launched on April 8, 1993. The videotape consists of an animated tour of the instruments that were included as part of the mission. The first half of the tape shows the various instruments, pointing to each in turn and identifying each by the associated initialisms. The instruments identified were: the Atmospheric Trace Molecule Spectroscopy (ATMOS), Millimeter Wave Atmospheric Sounder (MAS), Shuttle Solar Backscatter Ultraviolet/A (SSBUV/A) spectrometer, Solar Spectrum Measurement (SOLSPEC) instrument, Solar Ultraviolet Irradiance Monitor (SUSIM), Active Cavity Radiometer (ACR) and Solar Constant (SOLCON).) The second half of the animation shows the same tour without the pointing or the identification of the instruments.

Source record↗