A Multi-Dimensional Benefit Assessment of Automated Mobility Platforms (AMP) for Large Facilities

Automated Mobility Platform (AMP) is a general term for intelligently managed passenger mobility systems that leverage automation and electrification to improve system performance and sustainability through the integration of real-time data streams with advanced decision-making processes tailored for use in large facilities. Using airports as an example, the rapid growth in air travel demand has led to facility expansions and congested terminals, which directly impacts equity (e.g., increased challenges for passengers with reduced mobility [PRMs]) and sustainability - both of which are important metrics often neglected during the engineering design process. Therefore, to evaluate systems and inform critical decisions more effectively, a holistic evaluation framework is proposed that includes equity, sustainability, and infrastructure perspectives - referred to as a multidimensional benefit assessment. More specifically, the following analysis focuses on: (1) mobility, with emphasis on travel time and accessibility within an airport, contrasting existing systems with the proposed AMP system; (2) equity analysis, specifically to the PRM community, but with an eye to the whole of society; (3) energy consumption and greenhouse gas (GHG) emissions associated with intra-airport mobility, comparing and contrasting modes as well as impacts on overall airport operations efficiency; and (4) fundamental changes in building design enabled by AMPs for larger and more flexible, functional, and energy-efficient structures.

ADVANCED PROPULSION SYSTEMS↗

Hardware Specification and Reference Design for the Low-Cost, Interoperable, User-Centric, Supervisory Controller Kit for Small and Medium Size Commercial Buildings

Commercial buildings are responsible for approximately 20 percent of the total United States energy consumption and greenhouse gas emissions. Over 85 percent of these buildings lack building automation systems to manage the various building systems they have. Many of these buildings are small (< 50,000 square feet), underserved, and use rooftop units (RTUs) for heating, ventilation, and air-conditioning needs. Because these buildings lack proper control systems, they have several operational deficiencies that lead to excess energy consumption. Studies have shown that managing the RTU’s heating and cooling setpoints, schedules, setbacks, and optimal start times can result in 20 to 25 percent reduction in electricity consumption in small and medium commercial buildings (SMBs). In addition, improving the demand flexibility of these buildings will result in additional cost savings for the building owner. To address the needs of the SMBs, the Department of Energy’s Building Technologies Office jointly funded Pacific Northwest National Laboratory (PNNL) and Oak Ridge National Laboratory (ORNL) to design, develop, test, and validate a low-cost, interoperable, user-centric, retrofit supervisory controller kit (SC-SMB) that can be used to continuously optimize energy consumption and deliver demand flexibility of SMBs, including all-electric buildings, and provide a means for maximizing decarbonization benefits. The team also includes industry partners Edo and Intellimation. Previously, the team drafted an SC-SMB system specification document (Goodman et al. 2023). This document describes a reference design of a low-cost supervisory control system for SMBs, including the various hardware components, software system, and an example implementation of the reference design. The final release of the reference design is planned for December 2025. Section 2.0 of the report documents the relevant building types that the SC-SMB system is suitable for. Section 3.0 documents the various hardware components, their function, cost, whether they are off-the-shelve, support standard communication, etc., and the software system. An example deployment in a 10,000-sf building with six rooftop units, a hot water heater, solar, and storage is described in Section 4.0. The planned next steps are described in Section 5.0, and references are listed in Section 6.0.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-objective Eco-Routing Model Development and Evaluation for Battery Electric Vehicles

This paper develops a multi-objective eco-routing algorithm (eco- and travel time-optimum routing) for battery electric vehicles (BEVs) and internal combustion engine vehicles (ICEVs) and investigates the network-wide impacts of the proposed multi-objective Nash optimum (user equilibrium) traffic assignment on a large-scale network. Unlike ICEVs, BEVs are more energy efficient on low-speed arterial trips compared with highway trips. Different energy consumption patterns require different eco-routing strategies for ICEVs and BEVs. This study found that single-objective eco-routing could significantly reduce the energy consumption of BEVs but also significantly increase their average travel time. Consequently, the study developed a multi-objective routing model (eco- and travel time-routing) to improve both energy and travel time measures. The model introduced a link cost function that uses the specification of the value of time and the cost of fuel/energy. The simulation study found that multi-objective routing could reduce BEV energy consumption by 13.5%, 14.2%, 12.9%, and 10.7%, as well as ICEV fuel consumption by 0.1%, 4.3%, 3.4%, and 10.6% for “not congested, “slightly congested,”“moderately congested,” and “highly congested” conditions, respectively. The study also found that multi-objective user equilibrium routing reduced the average vehicle travel time by up to 10.1% compared with the standard user equilibrium traffic assignment for highly congested conditions, producing a solution closer to the system optimum traffic assignment. The results indicate that the proposed multi-objective eco-routing strategy can reduce vehicle fuel/energy consumption effectively with minimum impacts on travel times for both BEVs and ICEVs.

Engineering↗

A new database of building-space-specific internal loads and load schedules for performance based code compliance modeling of commercial buildings

Building-level loads and load profiles prescribed by current modeling rules save modelers time and avoid gaming during whole building performance modeling. However, recent studies show that they sometimes insufficiently capture the entire building performance due to the varied loads and load profiles for different space types. As a solution to this issue, this paper develops a database of building-space-specific loads and load profiles used in code compliance modeling. The existing sets of loads and load profiles are reviewed and the challenges behind using them for specific research topics are discussed. Then, the proposed method to develop the building-space-specific loads and load profiles is introduced. After that, the database for these building-space-specific loads and load profiles is presented. In addition, one case is studied to demonstrate the applications of these loads and load profiles. In this case study, three methods are used to develop building energy models: space-specific (using knowledge of the distribution and location of space types and applying the space-specific data in the developed database), building-level (assuming a lack of knowledge of the space types and using the building-level data in the developed database), and calculated-ratio (assuming knowledge of the distribution of space types but not their locations and calculating weighted average values based on the space-specific data in the developed database). Finally, the energy results simulated by using these three methods are compared, which show building-level methods can produce energy results up to 20% different than the space-specific methods. Finally, this paper discusses the application scope and maintenance of this new database.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methodology to evaluate design modifications intended to eliminate frosting and high discharge temperatures in air-source heat pumps (ASHPs) in cold climates

Air-source heat pumps (ASHPs) operating in cold climates experience problems with frosting and high refrigerant temperatures. These problems increase energy consumption, and their severity depends on the climatic conditions. In the present paper, a methodology for identifying the prevailing problem between frosting and high discharge temperatures is presented. Three performance indices, the frosting index (FI), the discharge index (DI), and the total loss index (TLI), are proposed to quantify the impacts of frosting and high discharge temperatures on the annual performance of ASHPs in different climatic conditions. The FI and DI show which problem (frosting or high discharge temperature) dominates, and the TLI indicates the combined effect of frosting and high discharge temperatures on the performance of an ASHP. A thermodynamic model of an ASHP coupled with the TRNSYS building simulation tool is used to estimate the performance of an ASHP and the proposed loss indices to estimate the impact of both frosting and high discharge temperatures for 45 cities in Canada. The results can be extended to other parts of the world that experience similar climatic conditions The results reveal that in cities in ASHRAE climatic zones 5 and 6 (classified as cold regions) where the ambient air temperatures are predominantly between -15 °C to 6 °C, ASHPs are heavily impacted by frosting. The problem of high discharge temperatures in ASHPs is predominant in cities in climate zones 7 and 8 (classified as very cold and subarctic regions) where the temperatures are frequently below -20 °C in winter. Among the cities considered, St. John, NL has the highest fraction of heating hours experiencing frosting (90 %), where the annual increase in energy consumption due to frosting is 13.5 % of the annual heating energy consumption. The highest annual increase in energy consumption due to high discharge temperatures is in Isachsen, NU (zone 8), where the increase is 30 % of the annual heating energy consumption. Based on the proposed indices, another index called the performance gain index (PGI) is created, which can be used as a first step to assess the energy-saving potential of design modifications applied to ASHPs to solve the problems of frosting and high discharge temperatures. The PGI will aid in developing climate specific ASHPs. One possible design modification is the use of a two-stage ASHP with an economizer. It is observed that the two-stage ASHP with economizer can mitigate high discharge temperatures and improve performance in very cold and subarctic regions (zones 7 and 8). However, it is not as beneficial in zones 5 and 6, where the impact of high discharge temperatures on performance is minimal and frosting dominates. Finally, a case study, using the PGI to evaluate the economic and environmental effectiveness of a two-stage ASHP with economizer is presented for the city of Saskatoon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-objective Eco-Routing Model Development and Evaluation for Battery Electric Vehicles.

This paper develops a multi-objective eco-routing algorithm (combined eco- and travel time-optimum routing) for battery electric vehicles (BEVs) and internal combustion engine vehicles (ICEVs) and investigates the network-wide impacts of the proposed multi-objective Nash optimum (user equilibrium) traffic assignment on a large-scale network. Eco-routing is a technique that finds the most energy efficient route. ICEV and BEV energy consumption patterns are significantly different with regard to their sensitivity to driving cycles. Unlike ICEVs, BEVs are more energy efficient on low-speed arterial trips compared to highway trips. Different energy consumption patterns require different eco-routing strategies for ICEVs and BEVs. This study found that single objective eco-routing could significantly reduce the energy consumption of BEVs but also significantly increase their average travel time. Consequently, the study developed a multi-objective routing model (eco- and travel time-routing) to improve both energy and travel time measures. The model introduced a link cost function that uses the specification of the value of time and the cost of fuel/energy. The simulation study found that multi-objective routing could reduce the BEV energy consumption by 13.5%, 14.2%, 12.9%, and 10.7%, as well as ICEV fuel consumption by 0.1%, 4.3%, 3.4%, and 10.6% for “not congested, “slightly congested,” “moderately congested,” and “highly congested” conditions, respectively. The study also found that multi-objective user equilibrium routing reduced the average vehicle travel time by up to 10.1% compared to the standard user equilibrium traffic assignment for highly congested conditions, producing a solution closer to the system optimum traffic assignment. The results indicate that the proposed multi-objective eco-routing strategy can reduce vehicle fuel/energy consumption effectively with minimum impacts on travel times for both BEVs and ICEVs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Study of Turbofan Engines Designed for Low Enery Consumption

Subsonic transport turbofan engine design and technology features which have promise of improving aircraft energy consumption are described. Task I addressed the selection and evaluation of features for the CF6 family of engines in current aircraft, and growth models of these aircraft. Task II involved cycle studies and the evaluation of technology features for advanced technology turbofans, consistent with initial service in 1985. Task III pursued the refined analysis of a specific design of an advanced technology turbofan engine selected as the result of Task II studies. In all of the above, the impact upon aircraft economics, as well as energy consumption, was evaluated. Task IV summarized recommendations for technology developments which would be necessary to achieve the improvements in energy consumption identified.

Neitzel, R. E.↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrification of industrial boilers in the USA: potentials, challenges, and policy implications

Decarbonization of the industrial heat demand through electrification could contribute significantly to climate change mitigation efforts. In the US industry, thermal processes accounted for 75% of the total final energy demand in 2018, of which 17% is consumed by conventional industrial boilers (excluding cogeneration) for steam generation. Electric boilers have a small share in the US industrial steam generation due to several techno-economic reasons. Here, this study employs a bottom-up approach to investigate the sector-level and state-level techno-enviro-economic potentials of deploying electric boilers in the US industry in different timeframes. The results show that the technical potential energy and CO 2 savings by electrifying industrial boilers are 595 PJ and 200 MtCO 2 per year in 2050, respectively; however, these incur additional costs in each sector. Although there may be individual cost-effective opportunities for electrifying boilers in specific industrial sites, the overall costs are high in all industrial sectors and states due to the large disparity between electricity and combustion fuel prices. To overcome the highlighted techno-economic barriers, a comprehensive action plan for different stakeholders is also formulated. This study provides novel insights that should inform policymakers’ and executives’ decisions about the electrification of the current and future US industrial boiler systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Steam generator model design parameter sensitivity study for small modular reactor system

Here, this study focuses on design parameter sensitivity studies pertaining to several Once-Through Steam Generator (OTSG) model cases both with and without a riser using python and advanced risk assessment and optimization tool, i.e. Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), to support a Small Modular Reactor (SMR) system. The presented Steam Generator (SG) python-based model is a mathematical representation of a steam-generating unit for a Pressurized Water Reactor (PWR)-type SMR system, including fluid flow and heat transfer equations, models, and correlations. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system, such as the Heat Transfer Coefficient (HTC), Reynolds number, Nusselt number, and heat transfer performance. Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in the input parameters. By using RAVEN, detailed design parametric sensitivity studies. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (i.e., ±1%, ±5% and ±10 % relative changes) for 600 samples. The analysis results give valuable insights into SG system performance, and provide justification for further research and development such as optimized sensor placement, design verification, validation, and optimization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Digitalization Guiding Principles and Method for Nuclear Industry Work Processes

The commercial U.S. light-water reactor fleet has been operating at historical efficiency, reliability, and safety over the last decade. Nuclear power has the highest capacity factor of any other power generation technology while also serving as the largest baseload source for carbon-free energy. Despite this remarkable achievement, continued operations for many plants are threatened due to fierce electricity market competition and rising operations and maintenance costs of which continued maintenance of obsolete analog equipment is a contributor. The digital age and associated technologies are where the future lies in process control, and nuclear has yet to take full advantage of the capabilities offered therein. The Light Water Reactor Sustainability Program (LWRS) at Idaho National Laboratory (INL), sponsored by the Department of Energy, has a mission to help the light-water reactor fleet manage its foundational capabilities to continue providing safe and reliable carbon-free power. LWRS helps support that mission by providing scientific, technology-based solutions for advanced concepts of operations with a more viable business model that will allow the fleet to continue to operate at peak levels through extended plant operation. The LWRS Digitalization Project at INL seeks to leverage digital technologies to synthesize and transform work processes. We provide a state-of-the-art analysis of digitalized work processes in nuclear power and investigate ways in which researchers at INL and the nuclear industry can work together to identify what data to access, how to access it, what to do with the data, and most importantly, how to use the insights for decision-making across all levels within the business. Borne from these considerations, we present four guiding principles for digitalization: develop a coherent digitalization plan, apply human factors engineering, establish data governance, and anticipate unintended consequences. Together, these principles form a method that plants can use to effectively to digitalize nuclear industry work processes. Our guiding principles are informed by multiple knowledge sources. First, we document activities from the Work Digitalization Initiative, which was conceived as a means for nuclear organizations to help define and standardize the industry’s approach to digitalizing work. Second, we detail primary research conducted with industry professionals regarding drivers and barriers to digitalization adoption. We present survey results that demonstrate what the industry hopes to get out of digitalization and the ways that INL can continue to support the industry’s digital transformation. Third, we present a digitalization use case with industry partners NextAxiom Technology and Xcel Energy. The project objective was to transform the current condition report work process from paper to digital, incorporating digitalized principles. We report the development of the application and lessons learned. The accomplishments achieved by this research and development serve to identify critical needs for plant guidance in support of digitalization implementation and contribute to the knowledge and strategies available for utilities considering or undertaking digitalization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Near-term hybrid vehicle program, phase 1

The preliminary design of a hybrid vehicle which fully meets or exceeds the requirements set forth in the Near Term Hybrid Vehicle Program is documented. Topics addressed include the general layout and styling, the power train specifications with discussion of each major component, vehicle weight and weight breakdown, vehicle performance, measures of energy consumption, and initial cost and ownership cost. Alternative design options considered and their relationship to the design adopted, computer simulation used, and maintenance and reliability considerations are also discussed.

Source record↗

Machine-Learning-Driven, Site-Specific Weather Forecasting for Grid-Interactive Efficient Buildings: Preprint

Emerging grid-interactive efficient buildings (GEBs) have great potential to provide much-needed demand flexibility to electric grids while fulfilling their own control targets by co-optimizing smart appliances, solar photovoltaics, electric vehicles, and energy storage at buildings. To enable the optimal operation of GEBs, site-specific weather information—such as temperature, solar irradiance, relative humidity, and wind speed—is crucial; however, this information is generally unavailable or expensive to obtain. This paper develops advanced machine learning methods to provide precise weather forecasts for individual building sites using readily available weather station data. Support vector regression and artificial neural networks have been employed to learn the spatiotemporal correlations between the weather conditions at nearby weather stations and the individual building site. The proposed site-specific weather forecasting methods have been validated using 1-year actual weather measurement data collected in the Denver metro area. Results show that the developed machine-learning-driven methods can accurately forecast the temperature at the target building site 1 hour ahead with mean absolute error less than 0.72°C and a 48% improvement over the persistence method. Site-specific weather forecasts will improve the understanding of the microclimate effect and its impact on building energy consumption. This information will drive efficiency upgrades and adjustments of building control strategies to improve energy savings and increase flexibility in building loads.

30 DIRECT ENERGY CONVERSION↗

Steam Generator Model Design Parameter Sensitivity Study Using Advanced Optimization Tools

This study focuses on design parameter sensitivity studies pertaining to a steam generator (SG) model, using both Python and machine-learning tools. The SG model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor (PWR)-type small modular reactor (SMR) system. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system (e.g., heat transfer coefficient [HTC], Nusselt number, heat transfer performance). Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in input parameters. By using machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), detailed design parametric sensitivity studies and model optimization were performed. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (±1% relative changes). The analysis results give valuable insights into SG system performance and optimization, and provide justification for researching optimized sensor placement to effectively monitor and obtain experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Steam Generator Model Design Parameter Sensitivity Study Using Advanced Optimization Tools

This study focuses on design parameter sensitivity studies pertaining to a steam generator (SG) model, using both Python and machine-learning tools. The SG model is a mathematical representation (including fluid flow and heat transfer equations/models/correlations) of a steam-generating unit in a pressurized water reactor (PWR)-type small modular reactor (SMR) system. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system (e.g., heat transfer coefficient [HTC], Nusselt number, heat transfer performance). Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in input parameters. By using machine-learning tools such as the Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), detailed design parametric sensitivity studies and model optimization were performed. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (±1% relative changes). The analysis results give valuable insights into SG system performance and optimization, and provide justification for researching optimized sensor placement to effectively monitor and obtain experimental data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SMR Accelerated Development Needs with Adequate Safety

The development of advanced Small Modular Reactors (SMRs) is ongoing. A customer-focused development approach requires accelerated design and analysis of the reactor system while minimizing engineering, regulatory, and economic challenges. SMRs, although not a new concept, are being considered for rapid deployment with optimized economic scalability, and several designs are currently seeking approval. Understanding the research and development needs, with adequate safety support, accelerates reactor development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improving Thermal Management Strategies for Data Centers: A Physical Testbed Incorporating Small Modular Reactor and Microreactor Technology

This study aims to accelerate the demonstration of various thermal management systems for data centers using nuclear-generated heat to enhance energy and grid reliability. Utilizing mobile containerized and stationary test beds at INL's High Performance Computing (HPC) facility, this project integrates with various nuclear-related energy systems testing facilities. Key components include immersion cooling apparatus, absorption chillers, and adjustable thermal management simulators. Tasks involve acquiring necessary hardware, sensors, and cooling apparatus, engaging with data center industry stakeholders, and providing a testing platform for algorithms, models, tools, and software. The objective is to expedite the deployment of nuclear-powered data centers, thereby improving energy reliability and affordability.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Accelerating Nuclear-Integrated Data Centers in the USA: SWOT Analysis, Power-Thermal Management Strategies, and Industrial-Scale Demonstration and Potential Deployment

Driven by the growth in digital services, cloud computing, AI, and manufacturing, data centers face rising energy demands that challenge traditional power sources and cooling efficiency. This study explores using nuclear power to meet these demands, focusing on accelerated reactor technology deployment and highlighting needs such as N+1/N+2 power supplies and integrated power-thermal management. A SWOT analysis addresses grid connectivity, reactors, and site selection, particularly DOE sites. Reactor technology demonstration and deployment could be accelerated by leveraging test facilities such as MARVEL, MAGNET, TED, FAS, DOME, LOTUS, ATR, Energy System Proving Grounds, and upcoming Energy Launch Pads, along with modeling and simulation tools such as RELAP5, MOOSE, VERA, RAVEN, and FORCE. The potential power and thermal management options, including various cooling technologies, waste-heat utilization, and an industrial-scale demonstration plan, aim to accelerate the integration of nuclear power and data centers in the USA, while emphasizing community and stakeholder engagement and synergistic efforts.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗