Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “solid-state detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Coloring Tetrahedral Semiconductors: Synthesis and Photoluminescence Enhancement of Ternary II-III 2 -VI 4 Colloidal Nanocrystals

Ternary tetrahedral II-III 2 -VI 4 semiconductors, where II is Zn or Cd, III In or Ga, and VI S, Se, or Te, are of interest in UV radiation detectors in medicine and space physics as well as CO 2 photoreduction under visible light. We synthesize colloidal II-III 2 -VI 4 semiconductor nanocrystals from readily available precursors and ascertain their ternary nature by structural and spectroscopic methods, including 77 Se solid-state NMR spectroscopy. The pyramidally shaped nanocrystals range between 2 and 12 nm and exhibit optical gaps of 2–3.9 eV. In the presence of excess anions on the particle surface, treatment with Lewis acidic, Z-type ligands results in better passivation and enhanced photoluminescence. Electronic structure calculations reveal the most stable, lowest energy polymorphs and coloring patterns. This work will pave the way toward more environmentally friendly, ternary semiconductors for optoelectronics and electrocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated microbial detection and quantification

A method for automated microbial detection includes collecting air particles into a solid-state sampler, the air particles including microbes, charging the air particles using a plasma field generated by propulsion electrodes, focusing the charged air particles toward a sample well of a microfluidic testing cartridge, tagging the charged air particles with a fluorescence marker, and detecting a quantity of the microbes using a fluorescence detector.

Gilbert, James H.↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Solid-state integrated real-time optical monitoring of biochemical assays

The disclosed technology includes a planar device for performing multiple biochemical assays at the same time, or nearly the same time. Each assay may include a biosample including a biochemical, enzyme, DNA, and/or any other biochemical or biological sample. Each assay may include one or more tags including dyes and/or other chemicals/reagents whose optical characteristics change based on chemical characteristics of the biological sample being tested. Each assay may be optically pumped to cause one or more of luminescence, phosphorescence, or fluorescence of the assay that may be detected by one or more optical detectors. For example, an assay may include two tags and a biosample. Each tag may be pumped by different wavelengths of light and may produce different wavelengths of light that is filtered and detected by one or more detectors. The pump wavelengths may be different from one another and different from the produced wavelengths.

Beer, N. Reginald↗

Introducing new resonant soft x-ray scattering capability in SSRL

Resonant soft x-ray scattering (RSXS) is a powerful technique for probing both spatial and electronic structures within solid-state systems. Here, we present a newly developed RSXS capability at beamline 13-3 of the Stanford Synchrotron Radiation Lightsource, designed to enhance materials science research. This advanced setup achieves a base sample temperature as low as 9.8 K combined with extensive angular motions (azimuthal ϕ and flipping χ), enabling comprehensive exploration of reciprocal space. Two types of detectors—an Au/GaAsP Schottky photodiode and a charge-coupled device detector with over 95% quantum efficiency—are integrated to effectively capture scattered photons. Extensive testing has confirmed the enhanced functionality of this RSXS setup, including its temperature and angular performance. The versatility and effectiveness of the system have been demonstrated through studies of various materials, including superlattice heterostructures and high-temperature superconductors.

Kuo, Cheng-Tai [SLAC National Accelerator Laborato↗

The ultrafast pixel array camera system and its applications in high energy density physics

Diagnostics in high energy density physics, shock physics, and related fields are primarily driven by a need to record rapidly time-evolving signals in single-shot events. These measurements are often limited by channel count and signal degradation issues on cable links between the detector and digitizer. Here we present the Ultrafast Pixel Array Camera (UPAC), a compact and flexible detector readout system with 32 waveform-recording channels at up to 10 Gsample/s and 1.8 GHz analog bandwidth. The compact footprint allows the UPAC to be directly embedded in the detector environment. A key enabling technology is the PSEC4A chip, an eight-channel switch-capacitor array sampling device with up to 1056 samples/channel. The UPAC system includes a high-density input connector that can plug directly into an application-specific detector board, programmable control, and serial readout, with less than 5 W of power consumption in full operation. We present the UPAC design and characterization, including a measured timing resolution of ~20 ps or better on acquisitions of sub-nanosecond pulses with minimal system calibrations. Example applications of the UPAC are also shown to demonstrate operation of a solid-state streak camera, an ultrafast imaging array, and a neutron time-of-flight spectrometer.

47 OTHER INSTRUMENTATION↗

Splitting phonons: Building a platform for linear mechanical quantum computing

Linear optical quantum computing provides a desirable approach to quantum computing, with only a short list of required computational elements. The similarity between photons and phonons points to the interesting potential for linear mechanical quantum computing using phonons in place of photons. Although single-phonon sources and detectors have been demonstrated, a phononic beam splitter element remains an outstanding requirement. Here we demonstrate such an element, using two superconducting qubits to fully characterize a beam splitter with single phonons. We further use the beam splitter to demonstrate two-phonon interference, a requirement for two-qubit gates in linear computing. In conclusion, this advances a new solid-state system for implementing linear quantum computing, further providing straightforward conversion between itinerant phonons and superconducting qubits.

97 MATHEMATICS AND COMPUTING↗

Simultaneous Multi-Bragg Peak Coherent X-ray Diffraction Imaging

The simultaneous measurement of two Bragg reflections by Bragg coherent X-ray diffraction is demonstrated on a twinned Au crystal, which was prepared by the solid-state dewetting of a 30 nm thin gold film on a sapphire substrate. The crystal was oriented on a goniometer so that two lattice planes fulfill the Bragg condition at the same time. The Au 111 and Au 200 Bragg peaks were measured simultaneously by scanning the energy of the incident X-ray beam and recording the diffraction patterns with two two-dimensional detectors. While the former Bragg reflection is not sensitive to the twin boundary, which is oriented parallel to the crystal–substrate interface, the latter reflection is only sensitive to one part of the crystal. The volume ratio between the two parts of the twinned crystal is about 1:9, which is also confirmed by Laue microdiffraction of the same crystal. The parallel measurement of multiple Bragg reflections is essential for future in situ and operando studies, which are so far limited to either a single Bragg reflection or several in series, to facilitate the precise monitoring of both the strain field and defects during the application of external stimuli.

47 OTHER INSTRUMENTATION↗

Adversarial autoencoder ensemble for fast and probabilistic reconstructions of few-shot photon correlation functions for solid-state quantum emitters

Second-order photon correlation measurements [g (2) (τ) functions] are widely used to classify single-photon emission purity in quantum emitters or to measure the multiexciton quantum yield of emitters that can simultaneously host multiple excitations – such as quantum dots – by evaluating the value of g (2) (τ = 0). Accumulating enough photons to accurately calculate this value is time consuming and could be accelerated by fitting of few-shot photon correlations. Here, we develop an uncertainty-aware, deep adversarial autoencoder ensemble (AAE) that reconstructs noise-free g (2) (τ) functions from noise-dominated, few-shot inputs. The model is trained with simulated g (2) (τ) functions that are facilely generated by Poisson sampling time bins. The AAE reconstructions are performed orders-of-magnitude faster, with reconstruction errors and estimates of g (2) (τ = 0) that are lower in variance and similar in accuracy compared to Maximum likelihood estimation and Levenberg-Marquardt least-squares fitting approaches, for simulated and experimentally measured few-shot g (2) (τ) functions (~100 two-photon events) of InP/ZnS/ZnSe and CdS/CdSe/CdS quantum dots. The deep-ensemble model comprises eight individual autoencoders, allowing for probabilistic reconstructions of noise-free g (2) (τ) functions, and we show that the predicted variance scales inversely with number of shots, with comparable uncertainties to computationally intensive Markov chain Monte Carlo sampling. Furthermore, this work demonstrates the advantage of machine learning models to perform uncertainty-aware, fast, and accurate reconstructions of simple Poisson-distributed photon correlation functions, allowing for on-the-fly reconstructions and accelerated materials characterization of solid-state quantum emitters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Single-Photon Detector & Counter for Transduction

Over the recent years, quantum computers have procured the attention of the public, largely due to their fast factoring capabilities and potential for efficient simulation of quantum dynamics \cite{RevModPhys.79.135}. This interest, coupled with advances in quantum transduction, could lead to the realization of a quantum distributed network, effectively linking dilution fridges across vast distances. Presently, there are several qubit systems developed for encoding quantum information. They primarily fall into two categories: those exploiting optical frequencies for excitation, and those operating at microwave frequencies. Optical frequency qubit systems include trapped ions, neutral atoms, quantum dots, and solid-state defects. Microwave frequency qubit system encompass superconducting qubits (transmon) and spins in crystals. Among these, transmons are particularly intriguing due to their low-loss of photons at microwave frequencies. The Josephson effect within a superconducting circuit enables high-fidelity quantum operations \cite{Microwave-optical_quantum_frequency_conversion}. Thus, it is non-trivial to develop an apparatus for efficiently bridging microwave and optical frequency regimes.

Bautista-Cortezano, Pablo↗

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Activator-doped Hg 2 Br 2 as next generation high performance scintillator for high energy physics research and other scientific and imaging applications

Existing COTS inorganic scintillators all have the characteristic of being very good at certain desirable properties, but not sufficient at other desirable properties for HEP. The demand for suitable scintillators (with regards to both scintillation detector properties and suitable pricing), to be used for modern intensities frontier (Mu2e-II), energy frontier (High luminosity large hadron collider) and future e+e- collider projects (aimed as Higgs bosons factory, such as the International Linear Collider (ILC) and the Future Circular Collider (FCC) are putting even higher challenges on crystal scintillators.In this work, we report the development of a novel high-performance scintillators that can address the issues associated with existing scintillators, the activator doped Hg2Br2. Initial results are very encouraging on the detection of gamma and alpha particles using a solid-state photomultiplier (SSPM). The responses have been stable and repeatable. Hg2Br2 also has many advantages over existing COTS scintillators such as: high density, bright, fast, good energy resolution, no intrinsic radiation, radiation hard and cost-effectiveness. Here, we present here why Hg2Br2 is the next generation scintillator for high energy physics experiments as well as other scientific and imaging applications such as planetary science and medical imaging.

36 MATERIALS SCIENCE↗

Part-scale evolution of fine-scale microstructural heterogeneity in solid-state additive manufacturing

Current solid-state additive manufacturing methods, refined through costly and time-consuming trial and error, have spurred interest in computational models that replicate material behavior under typical thermomechanical conditions (e.g., strain-rate ~ 102 s−1). These models, however, struggle to capture time-dependent microstructural evolution. In this work, Additive Friction-Stir Deposition (AFSD) is used as a representative case study for part-scale quantification of microstructure evolution at a fine spatial resolution (200 μm) by examining a liquid-nitrogen-cooled stop-action build via energy-dispersive X-ray diffraction coupled with a multi-channel detector. These results inform modeling efforts by linking process asymmetry to stored plastic strain, residual elastic strain, and texture development, and unlike current state-of-the-art characterization methods (e.g., EBSD or neutron diffraction), this approach provides both the spatial resolution and collection efficiency necessary to quantify fine-scale microstructural heterogeneity over large component volumes. As such, this technique provides essential validation data for computational models, e.g., crystal plasticity, enabling future prediction of heterogeneous behavior in AFSD and other additive manufacturing processes.

Franz, Cole [ORNL] (ORCID:0000000213465881)↗

Information theory optimization of signals from small-angle scattering measurements

Small-angle X-ray scattering (SAXS) of particles in solution informs on the conformational states and assemblies of biological macromolecules (bioSAXS) outside of cryo- and solid-state conditions. In bioSAXS, the SAXS measurement under dilute conditions is resolution limited, and through an inverse Fourier transform, the measured SAXS intensities directly relate to the physical space occupied by the particles via the P (r)-distribution. Yet, this inverse transform of SAXS data has been historically cast as an ill-posed, ill-conditioned problem requiring an indirect approach. Here, we show that through the applications of matrix and information theories, the inverse transform of SAXS intensity data is a well-conditioned problem. The so-called ill-conditioning of the inverse problem is directly related to the Shannon number. By exploiting the oversampling enabled by modern detectors, a direct inverse Fourier transform of the SAXS data is possible, provided the recovered information does not exceed the Shannon number. The Shannon limit corresponds to the maximum number of significant singular values that can be recovered in a SAXS experiment, suggesting this relationship is a fundamental property of band-limited inverse integral transform problems. This correspondence reduces the complexity of the inverse problem to the Shannon limit and maximum dimension. We propose a hybrid scoring function using an information theory framework that assesses both the quality of the model-data fit as well as the quality of the recovered P (r)-distribution. The hybrid score utilizes the Akaike information criteria and Durbin-Watson statistic that considers parameter-model complexity, i.e., degrees of freedom, and the randomness of the model-data residuals. The described tests and findings extend the boundaries for bioSAXS by completing the information theory formalism initiated by Peter B. Moore to enable a quantitative measure of resolution in SAXS, robustly determine maximum dimension, and more precisely define the best parameter model appropriately representing the observed scattering data.

Rambo, Robert P. [Science and Technology Facilitie↗

A 24-Channel Digitizer With a JESD204B-Compliant Serial Interface for High-Speed Detectors

In this report a 24-channel application-specific integrated circuit (ASIC) for the readout of high-speed CMOS active pixel sensors for charged particle detection is presented. The chip comprises 24 preamplifiers, 24 distinct 12-bit, 25 MSPS Pipelined analog-to-digital converters (ADCs) with self-calibration, an internal phase-locked loop (PLL), and a 3 Gbps serial interface that conforms to the JESD204B standard. To simplify interfacing with a variety of sensors, the ASIC also includes an automatic offset calibration loop. The high level of integration of the ASIC reduces overall system cost and area, and exploiting the signal characteristics of the image sensor allows the ADC to be optimized for reduced power dissipation. The use of an integrated serializer and an industry standard protocol simplifies integration of the ASIC into a complete camera system. The ASIC, called the High-Speed Image Preprocessor Targeted for Electron Readout, or HIPSTER, with a die area of 64.26 mm 2 , is packaged in a 480-ball grid array (BGA) and is fabricated in 180-nm CMOS technology. HIPSTER achieves typical differential nonlinearity (DNL) < 0.55 LSB, input-referred thermal noise of $114.5 μV-rms, and a bit error rate (BER) of better than 10-14. The power dissipation is 98 mW/channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies in pulse shape discrimination for an optimized ASIC design

The continued advancements of Silicon Photomultipliers (SiPMs) have made them viable photosensors for low recoil energy Pulse Shape Discrimination (PSD) between fast neutron and gamma interactions when coupled to an appropriate scintillator. At the same time, the large number of channels in a typical array calls for the development of low-cost and low-power electronics. A custom integrated circuit (ASIC) is an ideal solution for this purpose. To assess the requirements for such an ASIC, studies were performed using two scintillators, Stilbene and EJ-276, coupled to a 6 x 6 mm SiPM from Onsemi. We demonstrate that both scintillators are viable for performing PSD for interaction energies from 100 keV to several MeV while optimizing the integration periods used in the PSD metric. These measurements inform the design parameters of the ASIC under development.

Si-PMTs↗

Investigating resource-efficient neutron/gamma classification ML models targeting eFPGAs

There has been considerable interest and resulting progress in implementing machine learning (ML) models in hardware over the last several years from the particle and nuclear physics communities. A big driver has been the release of the Python package, hls4ml, which has enabled porting models specified and trained using Python ML libraries to register transfer level (RTL) code. So far, the primary end targets have been commercial field-programmable gate arrays (FPGAs) or synthesized custom blocks on application specific integrated circuits (ASICs). However, recent developments in open-source embedded FPGA (eFPGA) frameworks now provide an alternate, more flexible pathway for implementing ML models in hardware. These customized eFPGA fabrics can be integrated as part of an overall chip design. In general, the decision between a fully custom, eFPGA, or commercial FPGA ML implementation will depend on the details of the end-use application. In this work, we explored the parameter space for eFPGA implementations of fully-connected neural network (fcNN) and boosted decision tree (BDT) models using the task of neutron/gamma classification with a specific focus on resource efficiency. We used data collected using an AmBe sealed source incident on Stilbene, which was optically coupled to an OnSemi J-series silicon photomultiplier (SiPM) to generate training and test data for this study. We investigated relevant input features and the effects of bit-resolution and sampling rate as well as trade-offs in hyperparameters for both ML architectures while tracking total resource usage. The performance metric used to track model performance was the calculated neutron efficiency at a gamma leakage of 10 -3 . The results of the study will be used to aid the specification of an eFPGA fabric, which will be integrated as part of a test chip.

47 OTHER INSTRUMENTATION↗