Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “small buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Numerical investigation of the effects of icing on fixed and rotary wing aircraft

A 2-D multi-element airfoil code was modified to study the effects of icing on the aerodynamic characteristics of high lift systems. In each zone of the flow field, the solver numerically integrates the 2-D compressible Navier-Stokes equations using a time marching scheme. The surface pressure distribution is generated over a GAW 130 airfoil/flap combination for a flap setting of 25 degrees, and an angle of attack equal to 5 degrees, at a freestream Mach number equal to 0.3. A series of calculations were performed to determine the effects of small scale ice build up on the high lift characteristics of this arifoil/flap combination. The appendix summarizes this progress. Joint studies on correlation of a 3-D iced wing code with experimental data reviewed new measured laser Doppler velocimeter data in the separated region behind the leading edge ice shape. A version of the iced wing analysis using the Roe scheme was developed to evaluate the poor correlation between the computed and measured velocities in the separated region. Work on the extension of the wing-alone analysis to wing body configuration began with modifications to the 3-D iced wing analyses to accept externally generated grids and multi-block grids.

Sankar, L. N.↗

Solar system exploration in the 1990's and beyond

Exploration of Venus by Magellan and Pioneer Venus continues. Additionally, Galileo's Venus-earth-earth gravity assist trajectory to Jupiter has already provided targets of opportunity at Venus and at earth. Additional opportunities exist during the October 29, 1991, flyby of the asteroid Gaspra, the second earth gravity assist on December 8, 1992, and the flyby of the asteroid Ida on October 18, 1993. A fully successful mission through entry of the Jupiter atmospheric probe is anticipated in 1995/1996. The buildup of the Mars Observer spacecraft for a September 1992 launch is accelerating, and the development of the CRAF spacecraft and the orbiter for the NASA-ESA Cassini mission to Saturn is proceeding. Strategic plans to continue this ambitious program include early initiation of a phased program to detect other planetary systems; start of a program of low-cost, near-earth missions beginning with a near-earth asteroid rendezvous; continuation of moon-Mars exploration using sequentially launched single experiment Lunar Scouts and clusters of small landers to build up a Mars network of 16 stations; and finally, start of a major mission late in the century to explore Neptune and/or Pluto.

Huntress, Wesley T., Jr.↗

Aladdin: Exploration and Sample Return from the Moons of Mars

Aladdin is a remote sensing and sample return mission focused on the two small moons of Mars, Phobos and Deimos. Understanding the moons of Mars will help us to understand the early history of Mars itself. Aladdin's primary objective is to acquire well documented, representative samples from both moons and return them to Earth for detailed analyses. Samples arrive at Earth within three years of launch. Aladdin addresses several of NASA's highest priority science objectives: the origin and evolution of the Martian system (one of two silicate planets with satellites) and the composition and nature of small bodies (the building blocks of the solar system). The Aladdin mission has been selected as a finalist in both the 1997 and 1999 Discovery competitions based on the high quality of science it would accomplish. The equivalent of Aladdin's Phase A development has been successfully completed, yielding a high degree of technical maturity. Aladdin uses an innovative flyby sample acquisition method, which has been validated experimentally and does not require soft landing or anchoring. An initial phasing orbit at Mars reduces mission propulsion requirements, enabling Aladdin to use proven, low-risk chemical propulsion with good mass margin. This phasing orbit is followed by a five month elliptical mission during which there are redundant opportunities for acquisition of samples and characterization of their geologic context using remote sensing. The Aladdin mission is a partnership between Brown University, the Johns Hopkins University Applied Physics Laboratory, Lockheed Martin Astronautics, and NASA Johnson Space Center.

Pieters, C.↗

NASA Automated Fiber Placement Capabilities: Similar Systems, Complementary Purposes

New automated fiber placement systems at the NASA Langley Research Center and NASA Marshall Space Flight Center provide state-of-art composites capabilities to these organizations. These systems support basic and applied research at Langley, complementing large-scale manufacturing and technology development at Marshall. These systems each consist of a multi-degree of freedom mobility platform including a commercial robot, a commercial tool changer mechanism, a bespoke automated fiber placement end effector, a linear track, and a rotational tool support structure. In addition, new end effectors with advanced capabilities may be either bought or developed with partners in industry and academia to extend the functionality of these systems. These systems will be used to build large and small composite parts in support of the ongoing NASA Composites for Exploration Upper Stage Project later this year.

Wu, K. Chauncey↗

Energy burden aware and thermal resilience informed thermal energy storage system planning for disadvantaged communities

Disadvantaged communities often face a disproportionate energy burden because they need to allocate a higher percentage of their income to energy costs. More importantly, climate change-induced extreme weather events, such as heat waves and severe cold snaps, exacerbate these communities’ energy burdens. As a result, low- and medium-income communities are more likely to experience energy supply disruptions, increased health risks, and elevated energy bills because of inadequate thermal insulation and airtightness in their houses. Thermal energy storage (TES) systems, such as large-scale (community-level) geothermal energy storage and small-scale (building-level) phase change material (PCM)–based storage, have a great potential to improve building energy efficiency and to enhance thermal comfort, load shifting, and integration with renewable energy. The objective of this study is to optimally allocate building level PCM-based TES systems at the community level by considering energy equity and extreme weather effects. To this end, we developed an energy burden and thermal resilience–informed TES system planning framework, which includes three modules: (1) a community-level energy burden and thermal resilience assessment module, (2) building-level a TES system integration and assessment module, and (3) a community-level optimal planning module. Case studies were conducted on four disadvantaged communities in Montgomery and Shelby Counties in Tennessee with energy burdens >10% and with high percentages of people of color. The results indicate that this comprehensive planning framework can assist disadvantaged communities in reducing their energy burden and in bolstering their resilience against the adverse effects of climate change.

Shen, Zhenglai↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

An analysis of the hybrid internal mass modeling approach in EnergyPlus

Accurate simulation of building system dynamics is particularly important for understanding building energy flexibility. Among all dynamics in a building, a zone temperature’s variation is especially important, as it significantly affects a building’s electricity load profile when its heating, ventilating, and air conditioning (HVAC) system is controlled with on/off cycles or setpoint reset strategies. To accurately simulate a zone temperature’s dynamics, internal mass needs to be modeled carefully. In this paper, we compare the two internal mass modeling approaches provided by EnergyPlus, i.e., internal mass object and zone air capacitance multiplier, to better understand their impacts on zone temperature simulation. Real building zone temperature dynamic data from small- and medium-sized office buildings are analyzed and compared with simulated data. In particular, we illustrate the effectiveness of a hybrid method of the two EnergyPlus modeling approaches, which yields more realistic zone temperature dynamics, especially when the zone is conditioned with heat pump systems with on/off cycling.

Chen, Zhelun↗

Wakes from arrays of buildings

Experiments were carried out in a small wind tunnel in which atmospheric flow around buildings was simulated. Arrays of one, two, three, and four model buildings were tested, and wake profiles of velocity and turbulence were measured. The data indicate the effect of the buildings on the wind environment encountered by aircraft during landing or takeoff operations. It was possible to use the results to locate the boundaries of the air regions affected by the obstacles and to recommend preferred arrangements of buildings to maximize light safety.

Logan, E., Jr.↗

Wakes from arrays of buildings

Experiments were carried out in a small wind tunnel in which atmospheric flow around buildings was simulated. Arrays of one, two, three, and four model buildings were tested, and wake profiles of velocity and turbulence were measured. The data indicate the effect of the buildings on the wind environment encountered by aircraft during landing or takeoff operations. It was possible to use the results to locate the boundaries of the air regions affected by the obstacles and to recommend preferred arrangement of buildings to maximize light safety. Previously announced in STAR as N83-14430

Logan, E., Jr.↗

Using Residential and Office Building Archetypes for Energy Efficiency Building Solutions in an Urban Scale: A China Case Study

Building energy consumption accounts for 36% of the overall energy end use worldwide and is growing rapidly as developing countries continue to urbanize. Understanding the energy use at urban scale will lay the foundation for identification of energy efficiency opportunities to be deployed at speed. China has almost half of global new constructions and plays an important role in building suitability. However, an open source national building energy consumption database is not available in China. To provide data support for building energy consumptions, this paper used a simulation method to develop an urban building energy consumption database for a pilot city in Wuhan, China. First, residential, small, and large office building archetype energy models were created in EnergyPlus to represent typical building energy consumption in Wuhan. The baseline reference model simulation results were further validated using survey data from the literature. Second, stochastic simulations were conducted to consider different design parameters and occupants’ energy usage intensity scenarios, such as thermal properties of the building envelope, lighting power density, equipment power density, HVAC (heating, ventilation and air conditioning) schedule, etc. A building energy consumption database was generated for typical building archetypes. Third, data-driven regression analysis was conducted to support quick building energy consumption prediction using key high- level building information inputs. Finally, a web-based urban energy platform and an interface were developed to support further third-party application development. The research is expected to provide fast energy efficiency building design solutions for urban planning, new constructions as well as building retrofits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Active control of buildings during earthquakes

The objective of this report is to provide an overview of the different types of control systems used in buildings, to discuss the problems associated with current active control mechanisms, and to show the cost-effectiveness of applying active control to buildings. In addition, a small case study investigates the feasibility and benefits of using embedded actuators in buildings. Use of embedded actuators could solve many of the current problems associated with active control by providing a wider bandwidth of control, quicker speed of response, increased reliability and reduced power requirement. Though embedded actuators have not been developed for buildings, they have previously been used in space structures. Many similarities exist between large civil and aerospace structures indicating that direct transfer of concepts between the two disciplines may be possible. In particular, much of the Controls-Structures Interaction (CSI) technology currently being developed could be beneficially applied to civil structures. While several buildings with active control systems have been constructed in Japan, additional research and experimental verification are necessary before active control systems become widely accepted and implemented.

Vance, Vicki L.↗

Geothermal Direct-Use Applications for the District Energy System in Bucharest, Romania

The city of Bucharest, Romania, hosts the second-largest district energy system (DES) in the world. Geothermal resources can be considered as a supplementary heat source to support the demand for domestic hot water and space heating in the winter and shoulder seasons. The National Laboratory of the Rockies (NLR) has conducted a study that considers geothermal energy to serve a fraction of the existing district heating network operated by Electrocentrale Bucure?ti (ELCEN), the utility operating the DES. Lower Cretaceous and Jurassic limestones make up the main geothermal aquifer underlying Bucharest, which hosts temperatures suitable for district heating (up to 90 degrees C to the north of the city). Anomalous geothermal gradients have been observed to the north of the city, where a pumped well has produced 82 degrees C brine at the wellhead to feed the Therme Bucharest Spa. An anomalous gradient has also been reported to the southeast of the city (35 degrees C/km). NLR modeled the building heating loads of a small portion of the DES (a block of nine prototypical buildings) in its Urban Renewable Building and Neighborhood Optimization (URBANopt ) platform. To simulate meeting a baseload benchmark of 20 MWth deliverable to a small portion of the DES, the NLR team used GEOPHIRES to model production scenarios for (1) hydrothermal systems coupled with heat pumps targeting the main geothermal aquifer in the north, (2) enhanced geothermal systems targeting hot dry rock in the southeast, and (3) huff-and-puff systems targeting a gradient of 25 degrees C/km. Finally, NLR conducted a high-level sensitivity study around the techno-economics of these systems. The outcomes of this work indicate that hot dry rock geothermal resources that can deliver at least 90 degrees C hot water to the Geothermal District Energy System (GeoDES) offer a possible solution for supplemental geothermal heat delivered to the existing DES.

15 GEOTHERMAL ENERGY↗

Equitable Clean Energy Transitions for Small Communities: NREL Supports Kingston, New York, in Building a Community-First Approach to 100% Renewable Energy

In 2017, the city of Kingston, New York,committed to meet 100% power consumption with renewableenergy sources by 2050. Leading by example, Kingston hadalready made significant strides in energy efficiency in citybuildings; however, meeting the new, ambitious goal meantthat maintaining energy and housing affordability would be achallenge. The poorest residents of the city face a significantenergy burden, spending up to a quarter of income on powerand heating bills.

100% renewable goals↗

Rapid Quality Assessment in Additive Manufacturing: New Procedure Accelerates Build Quality Assessment. White paper

Accelerated growth of the additive manufacturing (AM) industry in recent years is accompanied by a rising need for methods to quickly assess quality at-scale. Current practices for quality inspection include nondestructive test methods and destructive testing of witness coupons, which are artifacts built alongside the actual part. However, these methods can be costly and time-consuming. Recognizing this need, the Additive Manufacturing Center of Excellence (AM CoE) initiated a project led by its partner, Auburn University, to develop rapid testing procedure using asbuilt samples tested in torsion to quantitatively assess build quality. The presented work developed a rapid testing procedure using as-built samples tested in torsion to quantify small variances for assessing build quality.

42 ENGINEERING↗

MPC solution for optimal load shifting for buildings with ON/OFF staged packaged units: Experimental demonstration, and lessons learned

Small and medium-sized commercial buildings (SMCB) are significant demand response resources, and it is important to develop grid-responsive control algorithms that exploit those resources and create financial benefits for building owners and HVAC service providers. Furthermore, unlike large-sized commercial buildings, there is an opportunity to have universally applicable control solutions for many SMCBs since those buildings have a consistent HVAC system configuration: SMCBs are commonly served by multiple-staged air conditioning units controlled by their own thermostats. Despite the demand response potential and scalability, however, very few control solutions are available for SMCBs. Typical model predictive control (MPC) and heuristic control approaches for cooling load shifting that lower thermostat setpoints before an electric price jump are suitable mainly for large-sized commercial buildings where a continuous capacity modulation is possible, e.g., via dampers in variable air volume terminal units. However, those approaches can cause undesired, high peaks for SMCBs due to the nature of ON/OFF unit staging and narrow thermostat deadbands. This could discourage the use of advanced grid-responsive controls for SMCBs due to the concern of high demand charges, and has to be resolved. This paper presents a MPC solution that overcomes this challenge. It has a hierarchical MPC structure where an upper level MPC is responsible for electrical load shifting in response to an electric price signal while a lower level MPC is responsible for coordinating compressor stages to eliminate unnecessary peaks and follows the setpoints determined by the upper level MPC. In this work, two one-month, comprehensive laboratory tests have been carried out to demonstrate load shifting and cost savings for the algorithm. Interesting trade-offs between energy efficiency and load flexibility were observed and are discussed, and lessons learned for applying MPCs for SMCBs are also presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Open Building Operating System: An Open-Source Grid Responsive Control Platform for Buildings

Grid-interactive efficient buildings (GEBs) with flexible loads are a promising method to decarbonize buildings, shift loads during peak hours, and lower energy use and electricity costs. Despite the promising benefits of GEBs, automation systems that manage flexible loads in response to energy prices or other grid signals are still uncommon in small and medium commercial buildings. Recent literature demonstrates such control solutions, but they often rely on custom integrations lacking the tools and drivers needed for scalability. To address these gaps, our team has created a fully open-source software stack capable of integrating heterogeneous flexible building loads and implementing integrated portable control applications called the Open Building Operating System (OpenBOS). The software can be deployed over existing control architecture with a small capital cost. OpenBOS leverages semantic models, which have been the subject of recent investigations to facilitate application portability. The use of semantic data reduces the labor and expense required to deploy and update smart control applications, increasing scalability. In this paper, the semantic modeling schema "Brick" was used, but the proposed approach can also be applied to ASHRAE standard 223P, when released. This paper describes the methodology and software components of OpenBOS and demonstrates its functionality with a rule-based demand flexibility control application configured using a semantic model. This application was tested at a real building in NY that uses a dual-fuel heating system made up of five ductless heat pump mini-splits and a central furnace serving a single zone. The demonstration reduced electricity costs at the site by 27%, demand during a shed event by 49%, and furnace usage by 35%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Imaging Earth-like Exoplanets with a Small Space Telescope

The Cen AB system represents a particularly attractive target for missions to directly image exoplanets. A potentially habitable planet can in theory be imaged in the system with a telescope as small as 40cm, provided it has a powerful enough starlight suppression system. Technology to enable this is rapidly maturing, and there have been several mission concept studies. This technology is relevant to missions like WFIRST, LUVOIR, and HabEx because it enables them to image binary stars. Small coronagraph mission concepts described here would also complement and synergize with all the above missions. We suggest that a stronger ongoing program is needed, perhaps building on the recent Small Sat concept study initiative, to support mission concept and proposal development for Small Sats ($35M), Missions of Opportunity ($75M) and possibly up through Explorer missions.

Ruslan Belikov↗

Fault-tolerant building-block computer study

Ultra-reliable core computers are required for improving the reliability of complex military systems. Such computers can provide reliable fault diagnosis, failure circumvention, and, in some cases serve as an automated repairman for their host systems. A small set of building-block circuits which can be implemented as single very large integration devices, and which can be used with off-the-shelf microprocessors and memories to build self checking computer modules (SCCM) is described. Each SCCM is a microcomputer which is capable of detecting its own faults during normal operation and is described to communicate with other identical modules over one or more Mil Standard 1553A buses. Several SCCMs can be connected into a network with backup spares to provide fault-tolerant operation, i.e. automated recovery from faults. Alternative fault-tolerant SCCM configurations are discussed along with the cost and reliability associated with their implementation.

Rennels, D. A.↗