At least 145 records · Page 8

Investigation of HZETRN 2010 as a Tool for Single Event Effect Qualification of Avionics Systems

NASA's future missions are focused on long-duration deep space missions for human exploration which offers no options for a quick emergency return to Earth. The combination of long mission duration with no quick emergency return option leads to unprecedented spacecraft system safety and reliability requirements. It is important that spacecraft avionics systems for human deep space missions are not susceptible to Single Event Effect (SEE) failures caused by space radiation (primarily the continuous galactic cosmic ray background and the occasional solar particle event) interactions with electronic components and systems. SEE effects are typically managed during the design, development, and test (DD&T) phase of spacecraft development by using heritage hardware (if possible) and through extensive component level testing, followed by system level failure analysis tasks that are both time consuming and costly. The ultimate product of the SEE DD&T program is a prediction of spacecraft avionics reliability in the flight environment produced using various nuclear reaction and transport codes in combination with the component and subsystem level radiation test data. Previous work by Koontz, et al.1 utilized FLUKA, a Monte Carlo nuclear reaction and transport code, to calculate SEE and single event upset (SEU) rates. This code was then validated against in-flight data for a variety of spacecraft and space flight environments. However, FLUKA has a long run-time (on the order of days). CREME962, an easy to use deterministic code offering short run times, was also compared with FLUKA predictions and in-flight data. CREME96, though fast and easy to use, has not been updated in several years and underestimates secondary particle shower effects in spacecraft structural shielding mass. Thus, this paper will investigate the use of HZETRN 20103, a fast and easy to use deterministic transport code, similar to CREME96, that was developed at NASA Langley Research Center primarily for flight crew ionizing radiation dose assessments. HZETRN 2010 includes updates to address secondary particle shower effects more accurately, and might be used as another tool to verify spacecraft avionics system reliability in space flight SEE environments.

Rojdev, Kristina↗

Single Event Effect (SEE) Test Planning 101

This is a course on SEE Test Plan development. It is an introductory discussion of the items that go into planning an SEE test that should complement the SEE test methodology used. Material will only cover heavy ion SEE testing and not proton, LASER, or other though many of the discussed items may be applicable. While standards and guidelines for how-to perform single event effects (SEE) testing have existed almost since the first cyclotron testing, guidance on the development of SEE test plans has not been as easy to find. In this section of the short course, we attempt to rectify this lack. We consider the approach outlined here as a "living" document: mission specific constraints and new technology related issues always need to be taken into account. We note that we will use the term "test planning" in the context of those items being included in a test plan.

LaBel, Kenneth A.↗

The Application of MCNP6.2 Unstructured Mesh Geometry Capabilities to the Study of Heavy Ion Single Event Effect on Microelectronic Devices and the Reactor Physics Analysis - 25691

Unstructured meshes allow irregular or complex geometries to be modeled precisely in Monte Carlo radiation transport codes. Through this capability, it is possible to share an unstructured mesh model between multiple codes that use unstructured mesh geometry and thus improving coupled multi-physics simulations. In this work, unstructured meshes are used to model energy deposition from heavy ion strikes for single event effects on microelectronic devices as well as neutron flux mapping of nuclear reactor configurations. In each case, MCNP6.2's unstructured mesh functionality and applicability to the problem is demonstrated and analyzed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single Event Effects Testing of the Linfinity SG1525A Pulse Width Modulator Controller

Pulse Width Modulator (PWM) Controllers are the heart of switching power supply systems in development today. The PWMs considered here have the same integration advantages as many other controllers but it also includes the interface drivers for the follow-on power Field Effect Transistors (FET). Previous work on these types of devices looked into the required test methodologies [ 11 and the impact of radiation on the soft start and shutdown circuits of typically incorporated in the technology [2]. Taking advantage of this previous work this study was undertaken to determine the single event destructive and transient susceptibility of the Linfinity SG1525A Pulse Width Modulator Controller. The device was monitored for transient interruptions in the output signals and for destructive events induced by exposing it to a heavy ion beam at the Texas A&M University Cyclotron Single Event Effects Test Facility. After exposing these devices to the beam, a new upset mode has been identified that can lead to catastrophic power supply system failure if this event would occur while drive power FETs off the two device outputs. The devices and the test methods used will be described first. This will be followed by a brief description of the data collected to date (not all data can be presented with the length constraints of the summary) and a summary of the key results.

Howard, J. W., Jr.↗

Microsemi RTG4 Rev C Field Programmable Gate Array Single Event Effects (SEE) Heavy-Ion Test Report

The goal of this study was to perform an independent investigation of single event destructive and transient susceptibility of the Microsemi RTG4 device. The devices under test were the Microsemi RTG4 field programmable gate array (FPGA) Rev C. The devices under test will be referenced as the DUT or RTG4 Rev C throughout this document. The DUT was configured to have various test structures that are geared to measure specific potential susceptibilities of the device. DesignDevice susceptibility was determined by monitoring the DUT for Single Event Transient (SET) and Single Event Upset (SEU) induced faults by exposing the DUT to a heavy ion beam. Potential Single Event Latch-up (SEL) was checked throughout heavy-ion testing by monitoring device current.

Field Programmable Gate Array (FPGA)↗

Analysis and Simulations of Space Radiation Induced Single Event Effects and Transients

Spacecraft electronic are affected by the space radiation environment. Among the different types of radiation effects that can affect spacecraft electronics is the single event transient (SET). The space environment is responsible for many of the single event transients which can upset the performance of the spacecraft avionics hardware. In this chapter we first explore the origins of single event transients, then explore the modeling of a single event transient in digital and analog circuit. The chapter also addresses the concept of crosstalk that could develop among digital circuits in the present of a SET event. The chapter also provides a discussion of SET hardening. We then provide a discussion concerning propagation of a single event transient event at the local, subsystem, and system level in a spacecraft using two different models, one of the models developed by the author, known as the state transition model. The final goal of the chapter is to provide a qualitatively methodology for assessing single event transients and its effects so that spacecraft avionics engineers can develop either hardware or software countermeasures in their designs. SET is not a form of electromagnetic interference (EMI) in its origin, but semantically SET is very similar to EMI because they are both caused a current source not previously accounted for. SET has the same effects as EMI and it can cause interference problems in electronic circuits via multiple coupling mechanisms similar to EMI, and therefore makes such circuits incompatible.

Perez, Reinaldo J.↗

Single Event Effects in Highly Scaled Devices for Space Applications

This paper discusses single-event upset (SEU) in memories and microprocessors that are the "drivers" of highly scaled commercial integrated circuits. Despite the decrease in critical charge that occurs for highly scaled CMOS devices, recent test data has shown that SEU rates are actually somewhat lower for scaled devices compared to older devices with larger feature size. Hard errors, which are increasingly important for memories, are discussed along with conventional soft errors. Functional errors in memories and microprocessors are particularly significant, and tend to dominate the response of highly scaled devices from an application standpoint. Predictions for future devices are made using the Semiconductor Industry Roadmap along with recent modeling and radiation test results.

microelectronics↗

Single-Event Effect (SEE) Survey of Advanced Reconfigurable Field Programmable Gate Arrays: NASA Electronic Parts and Packaging (NEPP) Program Office of Safety and Mission Assurance

The NEPP Reconfigurable Field-Programmable Gate Array (FPGA) task has been charged to evaluate reconfigurable FPGA technologies for use in space. Under this task, the Xilinx single-event-immune, reconfigurable FPGA (SIRF) XQR5VFX130 device was evaluated for SEE. Additionally, the Altera Stratix-IV and SiliconBlue iCE65 were screened for single-event latchup (SEL).

Xilinx Single-Event Effects (SEE) Test Consortium↗

Single-Event Effects in the Peripheral Circuitry of a Commercial Ferroelectric Random Access Memory

This paper identifies the failure modes of a commercial 130-nm ferroelectric random access memory. The devices were irradiated with heavy-ion and pulsed focused X-ray beams. Various failure modes are observed, which generate characteristic error patterns, affecting isolated bits, words, groups of pages, and sometimes entire regions of the memory array. Furthermore, the underlying mechanisms are discussed.

42 ENGINEERING↗

Single Event Effects Test Results for the Actel ProASIC Plus and Altera Stratix-II Field Programmable Gate Arrays

This work describes radiation testing of Actel's ProASIC Plus and Altera's Stratix-II FPGAs. The Actel Device Under Test (DUT) was a ProASIC Plus APA300-PQ208 nonvolatile, field reprogrammable device which is based on a 0.22micron flash-based LVCMOS technology. Limited investigation has taken place into flash based FPGA technologies, therefore this test served as a preliminary reference point for various SEE behaviors. The Altera DUT was a Stratix-II EP2S60F1020C4. Single Event Upset (SEU) and Single Event Latchup (SEL) were the focus of these studies. For the Actel, a latchup test was done at an effective LET of 75.0 MeV-sq cm/mg at room temperature, and no latchup was detected when irradiated to a total fluence of 1 x 10(exp 7) particles/sq cm. The Altera part was shown to latchup at room temperature.

heavy ions↗

Single-Event Effect Test Report Analog Devices LTC1604AIG#90117 ADC

This study is to characterize the destructive single-event latchup (SEL) susceptibility of the LTC1604AIG#90117 (LTC1604) analog/digital converter (ADC). The device was monitored for SEL current events on the power supplies during exposure to a heavy ion beam at Lawrence Berkeley National Laboratory (LBNL) 88-inch Cyclotron. Testing was performed on September 11, 2021.

single-event latchup (SEL)↗

Single-Event Effect Testing of the Analog Devices AD8041ARZ Operational Amplifier

This study was undertaken to determine the single event transient distribution of a transimpedance amplifier configuration of the AD8041 Operational Amplifier. The AD8041 is made in a bipolar technology and the application of interest has a bipolar supply of ±5 V. The device was monitored for transient events on the output voltage during exposure to a heavy ion beam at Lawrence Berkeley National Laboratory’s (LBNL) 88-inch Cyclotron.

Matthew B. Joplin↗

Single Event Effects on Space Radiation Hardened 64K SRAMS at Room temperature

The laser threshold linear Energy transfer for single event upsetscan be estimaed, even at room temperature, for space radiation hardened 64K SRAMs. The memories where independently developed to quality for the Qualified Manufacturer's List by IBM and Honeywell. The memory was so hard that high energy heavy ions generated by the Van de Graff could not determine the SEU threshold at room temperature. Use of pulsed Laser tests would meake it possible to forgo very expensive testing at ultra-high energy accelerators.

Space Radiation 64K SRAMS↗

Single-Event Effect Performance of a Conductive-Bridge Memory EEPROM

We investigated the heavy ion SEE characteristics of an EEPROM based on CBRAM technology. SEFI is the dominant type of SEE for each operating mode (standby, read-only, write/read). We also observed single bit upsets in the CBRAM cell, during write/read tests. the SEULET threshold is between 10 and 20 MeV * sq cm/mg, with an upper fluence limit of 3 × 10(exp 6) cm(exp -2) at 10 MeV * sq cm/mg. In the stand by mode, the CBRAM array appears immune to bit upsets.

single event effects↗