Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sensor selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Feasibility of Lead Fast Reactor Heat Exchanger Tube Online Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, wedges vs. direct application of piezoelectric sensors, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Progress Toward Molten Salt Reactor Heat Exchanger On-Line Monitoring

Within virtually all reactor systems with heat exchangers, the thinnest barriers between primary and secondary fluids are the heat exchanger tubes. Consistent with light water reactor experience, the advanced reactor heat exchangers are the most susceptible regions for corrosion and leakage (NRC, 2019). Moreover, traditional inspections and repairs using robotics will be expensive or impractical. On-line structural health corrosion monitoring (OLSHM) is therefore desirable to detect tube degradation prior to leaks that may allow mixing of heat exchanger fluids. Rhetorically many molten salt reactor (MSR) designers plan for on-line monitoring of critical reactor components including heat exchangers but there are no proven OLSHM sensors or systems for MSR heat exchangers. Guided wave ultrasound from the tube-end or ID using conventional low-temperature piezoelectric sensors has been shown to be sensitive to pits and cracks less than 50% through-wall in long pipes and tubes (Narayanan M.M., 2019) . Mode and frequency selection are important for practical sensor design decisions and ultimate performance. The L-0 wave-mode is easily excited by L-mode transducers but they have surface normal wave motion that will be sensitive to and more attenuative because of fluid interaction with the tube surface (Rose J.L., 1994). Shear Horizontal (SH) wave modes have material motion parallel to the tube surface therefore are virtually unaffected by fluid interaction. For SH-0 to be nondispersive in steel, the frequency-thickness product (MHz-mm) must be less than approximately 1.5. SH mode transducers must be coupled by a material that can support shear stress; a thin layer of honey works well for temporary sensors and an adhesive or a brazed metallurgical bond for permanent sensors. If sensors are incorporated into the fabrication process, the same kinds of SH-0 waves can be generated from the stagnant flow area of the tube OD without compromising the heat-exchange tube function. Piezoelectric materials are also available that can withstand harsh temperatures of molten salt heat exchangers (Stevenson T., 2015) (Machura et al., 2008). Though they may not have as high-performance characteristics, their performance only needs to be good enough to detect flaws of interest. This project attempts to demonstrate feasibility to develop a sensor that can be sensitive to flaws of interest and perform long-term monitoring of a molten salt reactor heat exchanger. Benefits to the advanced reactor system include: • Minimizing the expense of a reactor shut down for periodic inspection—only shutdown for cause. • Reduce risk of unexpected tube rupture by detecting flaws before they grow to through-wall leaks. • Cost reduction by minimizing need to design for manual/robotic inspectability. Transducer design, characterization of the beam profile, and ultrasonic pulse-echo responses from a representative heat exchange tube with fabricated flaw types are discussed.

On-Line Tube Monitor, Guided Wave Ultrasound, SH-0↗

Selective acetate recognition and sensing using SWCNTs functionalized with croconamides

Croconamides are a new class of dual-hydrogen bond donors that have attracted interest in anion recognition and sensing applications due to their strong H-bond donation capability. In this work, we report chemiresistive sensors for the detection of anions based on poly(4-vinylpyridine) (P4VP)-wrapped single-walled carbon nanotubes (SWCNTs) functionalized with croconamide-based selectors. Model structures of asymmetric N,N-substituted croconamide selectors with N,N-substitutional groups of alkyl cationic pyridinium and electron-withdrawing moieties such as aniline (6) and 3,5-bis(trifluoromethyl)phenyl (7) groups were synthesized and their binding affinities for various anions were characterized using UV–vis and 1 H NMR titrations. Switchable binding of oxoanions was observed with selector 7, wherein HSO 4 – formed hydrogen bonding interactions and acetate (AcO – ) induced deprotonation of the NH- protons of the croconamide. Large sensitivity transitions were obtained toward AcO – for both P4VP-6-SWCNT (S = 95.68 ± 2.11 %) and P4VP-7-SWCNT (S = 140.91 ± 3.68 %) at 83.33 mM, which was attributed to deprotonation of the croconamide selectors upon addition of AcO – . In conclusion, three serial sensors were assembled in a sensor array that rapid and selective screening of AcO – was demonstrated against other oxoanions such as HSO 4 – and H 2 PO 4 – in real-time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heuristic based analytics for gas leak source identification

Heuristic-based techniques for gas leak source identification are provided. In one aspect, a method for identifying a location of a gas leak source includes: obtaining gas sensor data and wind data synchronously from a gas leak detection system having a network of interconnected motes comprising gas sensors and wind sensors, with the gas sensors arranged around possible gas leak sources in a given area of interest; identifying the location of the gas leak source using the gas sensor data and wind data; and determining a magnitude of gas leak from the gas leak source using the location of the gas leak source and a distance d between the location of the gas leak source and a select one of the gas sensors from which the gas sensor data was obtained. A gas leak detection system is also provided.

03 NATURAL GAS↗

Perovskite-sensitized β-Ga 2 O 3 nanorod arrays for highly selective and sensitive NO 2 detection at high temperature

Amongst various gaseous pollutants, NO 2 is one of the major exhausts originating from fossil fuel and gas combustions in vehicle engines and power plants at high temperature. Under such a scenario, in situ and real-time gas detection and monitoring solutions are largely limited, which hinders the energy-efficient and resource-saving operations of these advanced energy systems. Herein, a new type of perovskite-sensitized β-Ga 2 O 3 nanorod-array has been successfully fabricated to detect NO x at high temperature selectively and sensitively. The demonstrated gas sensors are highly sensitive to NO 2 at 800 °C, with excellent reversible and reproducible response characteristics. Through the surface decoration of perovskite-type La 0.8 Sr 0.2 CoO 3 (LSCO) nanoparticles, the sensitivity of β-Ga 2 O 3 nanorod array gas sensors is enhanced by nearly an order of magnitude, along with much faster response dynamics. A remarkable selectivity toward oxidative gases was also demonstrated with the robust differentiation of NO 2 .

36 MATERIALS SCIENCE↗

Demonstration of VOC Fenceline Sensors and Canister Grab Sampling near Chemical Facilities in Louisville, Kentucky

Experimental fenceline sensor pods (SPods) fitted with 30 s duration canister grab sampling (CGS) systems were deployed at a site near chemical facilities in Louisville, KY, from 4 June 2018 to 5 January 2020. The objective of the study was to better understand lower cost 10.6 eV photoionization detector (PID)-based volatile organic compound (VOC) sensors and investigate their utility for near-source emissions detection applications. Prototype SPods containing PID sensor elements from two different manufacturers yielded between 78% and 86% valid data over the study, producing a dataset of over 120,000 collocated pair fenceline measurements averaged into 5-min datapoints. Ten-second time-resolved SPod data from an elevated fenceline sensor signal day are presented, illustrating source emission detections from the direction of a facility 500 m west of the monitoring site. An SPod-triggered CGS acquired in the emission plume on this day contained elevated concentrations of 1,3-butadiene and cyclohexane (36 parts per billion by volume (ppbv) and 637 ppbv, respectively), compounds known to be emitted by this facility. Elevated concentrations of these compounds were observed in a subset of the 61 manual and triggered CGS grab samples acquired during the study, with winds from the west. Using novel wind-resolved visualization and normalization approaches described herein, the collocated pair SPod datasets exhibited similarity in emission source signature. With winds from the west, approximately 50% of SPod readings were above our defined theoretical detection limit indicating persistent measurable VOC signal at this site. Overall, this 19-month study demonstrated reasonable prototype SPod operational performance indicating that improved commercial forms of lower cost PID sensors could be useful for select VOC fenceline monitoring applications.

1,3-butadiene↗

A novel optical sensor for Pb 2+ detection based on in-situ formation of Ruddlesden-Popper phase (C 4 H 9 NH 3 ) 2 PbBr 4 perovskite

On account of the concentration sensitive photoluminescence (PL) property of the lead-based Ruddlesden-Popper (RP) phase perovskite material, a novel sensing mechanism for highly selective Pb 2+ detection based on the in-situ formation of highly emissive luminescence structure matrix (C 4 H 9 NH 3 ) 2 PbBr 4 has been demonstrated. The sensor exhibits high sensitivity and selectivity for detecting Pb 2+ in complex metal cations mixture solution. This research reports a novel type of sensor mechanism based on the in-situ formation of luminescent lead-based RP phase perovskite. Here, it paves the way for developing highly selective optical sensors for detecting heavy metal cations via their corresponding luminescence structure matrix.

36 MATERIALS SCIENCE↗

Cellular Phosphate Sensing and Anion Binding by an Azacrown‐Calixpyrrole Hybrid

A hybrid receptor-sensor for anions originating from the merging of positively charged ammonium moieties for electrostatic attraction/stronger binding of azacrowns with directionality of calixpyrrole hydrogen bond donors for selectivity is investigated. As demonstrated this hybrid receptor-sensor shows a remarkable selectivity for orthophosphate even in the presence of other phosphates and anions found in cellular materials (K assoc H 2 PO 4 − >H 2 P 2 O 7 2− >AMP − ≫ADP 2− or ATP 3− over halides, nitrate, or hydrogen sulfate; all Na + salts in water) but also cellular polyphosphate or phospholipids. This selectivity is harnessed in a real-time monitoring of cell lysis by lysozyme, which releases orthophosphate and other phosphates and anions from the cells. This sensitive (LOD 0.4 μM) fluorescence-based microscale method compares favorably with the state-of-the-art techniques but can easily be practiced in a high-throughput screening (HTS) manner. The anion binding and selectivity in aqueous solutions were investigated by NMR and put in context with phosphate binding of the parent calix[4]pyrrole. The microscopic understanding of anion binding by the hybrid receptor was then obtained from a combination of density functional theory (DFT), classical molecular dynamics (MD) with explicit water solvation, and ab initio MD (AIMD) simulations. Correlating the NMR and fluorescence binding data with studies of solvation of the receptor, phosphate anion, and the resulting complex confirms the binding is largely driven by entropic component (TΔS) associated with receptor and anion desolvation.

Anions↗

Laboratory testing methods to evaluate the reliability of occupancy sensors for commercial building applications

The energy performance of commercial buildings is greatly influenced by occupants which are highly variable and among the most unpredictable components of a building's operation. While most building control systems use fixed, predetermined occupancy schedules, these fixed occupancy levels can be quite different from actual occupancy. This can cause unnecessary energy consumption, particularly from heating, ventilation, and air conditioning (HVAC) and lighting systems which are responsible for approximately 60% of commercial buildings' energy use. The use of occupancy counting sensor systems integrated with building management system controls is one method that can be used to improve the energy-consuming performance of buildings. However, there is no standardized universal methodology and metrics to evaluate their reliability. The aim of this research is to develop a uniform evaluation methodology to assess the reliability of occupancy counting sensor systems in a controlled laboratory environment. The developed testing methodology includes both “typical” scenarios representing the occupancy scenarios of a typical commercial building, and “failure” testing scenarios which represent a range of potential scenarios that may impact a sensor system's reliability. These methods were then implemented in a case study to evaluate the performance of two novel occupancy counting sensor systems (i.e., door-centric, and camera-based). Results suggest that typical testing results can be used to compare the overall performance of the occupancy counting sensor systems; however, failure testing is also important to understand the weaknesses of the sensor system in order to select the suitable one for the intended use of the commercial building. In addition, the proposed methodology includes a modified confusion matrix which enables the ability to identify if failures are caused by over or under counting occupants and to what extent this occurs over the testing period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Functionalization of nitrogen vacancy-containing nanodiamonds with a metal-organic framework for quantum sensing applications

Nitrogen vacancy (NV)-containing nanodiamonds (NDs) are an important material in applications such as biological imaging, catalysis, and, in particular, quantum sensing. Careful manipulation of the surface coating on NV NDs is essential for both enhancing quantum sensor performance and for tuning selectivity towards specific sensing targets. Here, we demonstrate a simple synthetic approach for functionalizing NV NDs with the zeolitic imidazole framework-8 (ZIF-8) metal–organic framework (MOF), providing a well-ordered, porous scaffold for immobilizing target analytes near the NV ND surface. The composites were structurally characterized by x-ray diffraction, electron microscopy, and X-ray photoelectron spectroscopy, and these results were all consistent with NV NDs fully encapsulated by ZIF-8. Critically, the luminescent properties of the NV NDs, which are vital for quantum sensing experiments such as optically detected magnetic resonance (ODMR), are unchanged by the MOF coating. Moreover, spin relaxometry experiments indicate that the ZIF-8 coating significantly enhances the NV ND spin longitudinal relaxation time T1, a critical quantum parameter for sensing applications. Given the tremendous structural diversity of MOFs, the NV ND@MOF composites are an exciting material class with exciting implications for the development of high-performance quantum sensors.

Crawford, Scott↗

Additively Manufactured Strain Sensing for Nuclear Reactor Applications

Real-time monitoring of materials in harsh environments is a crucial technique towards reducing innovation time in nuclear systems. The successful measurement of real time, in-situ strain measurements during nuclear reactor operation requires innovative sensing solutions, including novel sensing strategies as well as advanced sensor design, manufacturing, and materials selection. In this paper, we will discuss two primary strategies for in-situ strain measurement strategies: additively manufactured (AM) capacitive strain gauges (CSGs) and digital image correlation (DIC). Current commercial strain gauges have limited applications in reactors due to the harsh operating conditions and non-trivial attachment strategies (i.e., welding, epoxy-adhesive) that can affect both the sensing performance and the underlying substrate under testing. AM CSGs are a viable solution as they have a low profile, low hysteresis, and wireless sensing integration capabilities that will enhance nuclear sensing technologies. In this work, the mechanical and thermal performance of the AM CSGs were tested up to 300 °C using ASTM standardized testing procedures to simulate the temperatures found in existing light water reactors. The AM CSGs had a similar performance across multiple samples which correlates to analytical models. This work leads towards the development of CSGs designed for higher temperatures and additional environmental factors found in Generation-IV reactors. Non-contact sensors, such as DIC, offer a less destructive way to measure deformation of materials when compared to alternative methods of in-situ strain determination, such as weldable strain gauges. However, DIC requires high contrast surfaces, which often relies on the implementation of artificial patterns. Using traditional splatter techniques to fabricate these patterns have limitations, including poor surface adhesion and reproducibility. In this work, AM fabrication techniques were implemented to avoid such limitations. Accordingly, aerosol jet printing (AJP) was used to print small scale periodic patterns of silver on stainless steel and aluminum tensile specimens. DIC was employed to monitor strain (up to 1100 µe) during temperature cycling from 23-600 °C. The results validated the use of AJP to better control pattern parameters for small fields of view applications at high temperatures.

36 MATERIALS SCIENCE↗

High-Sensitivity NO 2 Gas Sensor: Exploiting UV-Enhanced Recovery in a Hexadecafluorinated Iron Phthalocyanine-Reduced Graphene Oxide

Monitoring ultralow nitrogen dioxide (NO 2 ) concentrations is crucial for air quality management and public health. However, the existing NO 2 gas sensors have several defects, like high cost and power consumption, and exhibit poor selectivity. This study addresses these challenges by presenting a novel hexadecafluorinated iron phthalocyanine-reduced graphene oxide (FePcF 16 -rGO) covalent hybrid sensor for NO 2 detection. This innovative approach, which overcomes the limitations of fabrication cost, energy efficiency, and gas selectivity, is a significant step forward in gas sensor technology. The sensor demonstrates exceptional sensitivity toward ultralow NO 2 concentrations (15.14% response for 100 ppb) with a rapid 60 s UV light-induced recovery. Additionally, the sensor exhibits high selectivity for NO 2 , achieving a limit of detection (LOD) of 8.59 ppb. This approach paves the way for developing cost-effective, energy-efficient, and miniature NO 2 monitoring devices for improved environmental monitoring and enhanced safety in workplaces where NO 2 exposure is a concern.

36 MATERIALS SCIENCE↗

Developments in Online Monitoring Technologies for Autonomous Microreactor Operations

This report presents the results of an ongoing research and development (R&D) effort to develop an online monitoring (OLM) system to support autonomous microreactor operations. A key component of this work is an evaluation of Artificial Intelligence (AI) and Machine Learning (ML) techniques to identify, diagnose, and predict problems with sensors and processes of the reactor. As described herein, selected methods of AI/ML were used to identify and diagnose anomalous sensor and system behaviors using data from a thermal-hydraulic flow loop and from operating nuclear power plants. This work serves to further the state-of-the-art in OLM technologies for nuclear reactor applications and will ultimately result in a comprehensive system to enable OLM of critical structures, systems, components, and processes in microreactors.

Machine learning↗

Cobalt-Doped Tungsten Oxide Nanoparticles for Electrochemical Sensing and Detection of a Penicillin Antibiotic: Amoxicillin

A sensitive electrochemical sensor for the determination of antibacterial amoxicillin (AMXL) in pharmaceutical dosage and environmental samples was developed, since its residues were found in water, food, and biological samples to pose adverse health risks such as immune–allergic reactions and antimicrobial resistance. WO 3 -based sensors are reported to provide higher sensitivity, selectivity, and stability during the electrochemical reaction. Considering this, Co-doped WO 3 nanostructures were synthesized by the hydrothermal method yielding a mixture of nanoparticle and nanorod structures and applied to the assay of AMXL. Extensive characterizations were carried out by SEM, XRD, TEM, and XPS analysis that confirm the monoclinic crystal structure with a uniform Co distribution in the WO 3 lattice. The optimum doping amount of Co in the lattice is found to be 1.80 at %. The electrochemical performance of the Co-WO 3 /carbon paste electrode (CPE) was evaluated for the determination of AMXL under optimum conditions using cyclic voltammetry, electrochemical impedance spectroscopy, and square wave voltammetry. The Co-WO 3 /CPE showed two linear detection ranges at 0.01–0.1 μM with the linear regression I pa = 3.73 [AMXL] + 0.77 with R 2 = 0.96 and at 0.1 to 30.0 μM with the linear regression I pa = 3.76 [AMXL] + 0.69 with R 2 = 0.95. The limit of detection was 9.1 nM (SNR = 3), and the limit of quantification was 30.6 nM (SNR = 10). The sensitivities for lower and higher concentration ranges were 63.22 and 63.73 μA μM –1 cm –2 , respectively. Furthermore, Co-WO 3 /CPE showed high selectivity and anti-interference capabilities. In conclusion, the sensing and disposable Co-WO 3 /CPE sensor showed a great potential for AMXL analysis in spiked soil, water, and Amoxil tablet samples with desirable percentage recovery.

Shanbhag, Mahesh M. [KLE Technological University,↗

Enhancing ZnO nanowire gas sensors using Au/Fe 2 O 3 hybrid nanoparticle decoration

Heterojunctions are an important strategy for designing high performance electrical sensor materials and related devices. Herein, a new type of metal-semiconductor hybrid nanoparticle has been successfully used to remarkably sensitize the surface of ZnO nanowires for detecting NO 2 with high responses over a broad temperature window ranging from room temperature to 600 °C. These hybrid nanoparticles are comprised of iron oxide nanowires with well dispersed single crystalline Au nanoparticles. The hybrid nanoparticle decorated ZnO nanowires have achieved a giant response, as high as 74 500 toward NO 2 gas, about 42 times that of Au decorated ZnO nanowire sensors. This dramatic enhancement may be attributed to the efficient charge transfer across the Au–Fe 2 O 3 Schottky and Fe 2 O 3 –ZnO semiconductor heterojunction interfaces. Due to the incorporation of thermally-stable Fe 2 O 3 nanoparticles as the support of Au nanoparticles, the working temperature of nanowire sensors was successfully extended to higher temperatures, with an increase of 200 °C, from 400 °C to 600 °C. Such a combination of semiconductor heterojunction and semiconductor-metal Schottky contact presents a new strategy for designing high performance electrical sensors with high sensitivity, stability, selectivity, and wide operation temperature window, which are potentially suitable for advanced energy systems such as automotive engines and power plants.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measuring Irradiance for Bifacial PV Systems

The advent of bifacial PV systems drives new requirements for irradiance measurement at PV projects for monitoring and assessment purposes. While there are several approaches, there is still no uniform guidance for what irradiance parameters to measure and for the optimal selection and placement of irradiance sensors at bifacial arrays. Standards are emerging to address these topics but are not yet available. In this paper we review approaches to bifacial irradiance monitoring which are being discussed in the research literature and pursued in early systems, to provide a preliminary guide and framework for developers planning bifacial projects.

bifacial↗

Measuring Irradiance for Bifacial PV Systems: Preprint

The advent of bifacial PV systems drives new requirements for irradiance measurement at PV projects for monitoring and assessment purposes. While there are several approaches, there is still no uniform guidance for what irradiance parameters to measure and for the optimal selection and placement of irradiance sensors at bifacial arrays. Standards are emerging to address these topics but are not yet available. In this paper we review approaches to bifacial irradiance monitoring which are being discussed in the research literature and pursued in early systems, to provide a preliminary guide and framework for developers planning bifacial projects.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Synergistic Integration of Chemo-Resistive and SERS Sensing for Label-Free Multiplex Gas Detection

Practical sensing applications such as real-time safety alerts and clinical diagnoses require sensor devices to differentiate between various target molecules with high sensitivity and selectivity, yet conventional devices such as oxide-based chemo-resistive sensors and metal-based surface-enhanced Raman spectroscopy (SERS) sensors usually do not satisfy such requirements. In this report a label-free, chemo-resistive/SERS multimodal sensor based on a systematically assembled 3D cross-point multifunctional nanoarchitecture (3D-CMA), which has unusually strong enhancements in both “chemo-resistive” and “SERS” sensing characteristics is introduced. 3D-CMA combines several sensing mechanisms and sensing elements via 3D integration of semiconducting SnO 2 nanowire frameworks and dual-functioning Au metallic nanoparticles. It is shown that the multimodal sensor can successfully estimate mixed-gas compositions selectively and quantitatively at the sub-100 ppm level, even for mixtures of gaseous aromatic compounds (nitrobenzene and toluene) with very similar molecular structures. This is enabled by combined chemo-resistive and SERS multimodal sensing providing complementary information.

36 MATERIALS SCIENCE↗