At least 145 records · Page 8

ECAR-7813 Rev 0 Secondary Coolant Cover Gas System Stirling Engine Tube Rupture Analysis, Insulation Block Analysis, and Labyrinth Seal Design

The purpose of this ECAR is to document compliance with best engineering practices for the Secondary Coolant Cover Gas System of the MARVEL microreactor which includes a Stirling Engine helium tube rupture analysis, an analysis to verify the strength of the insulation blocks, and the design of the Labyrinth Seal.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Sealing of fractures in a representative CO 2 reservoir caprock by migration of fines

The impact of fines migration on fracture transmissivity reduction was investigated by injecting a brine solution containing a suspension of 0.1 wt. % kaolinite particles with a mean particle size distribution of 9.6 µm through fractured shale core samples. The fractures had apertures estimated to be approximately 100 µm. A mass balance approach was used to determine the quantity of kaolinite that was deposited within the fractures (influent – effluent = amount deposited in fractures). Large fractions (44 to 90%) of the suspended kaolinite pumped through the fractures were deposited within the fractures. Based on fracture volumes estimated with X-ray computed tomography, it was determined that approximately 10 to 17% of the fracture volume was filled with kaolinite at the point when flow was completely restricted. These results indicate that 100 µm fractures in CO 2 reservoir caprocks could be sealed within hours if the brines passing through the fractures contain a proportional volume of particulates to the tests performed in this laboratory study.

04 OIL SHALES AND TAR SANDS↗

National nuclear forensics libraries: a case study on benefits and possibilities for identification of sealed radioactive sources

A National Nuclear Forensic Library (NNFL) is a useful nuclear forensics tool which consists of information and subject matter expertise on radioactive and nuclear (RN) materials produced, used or stored within a State. If RN material is found out of regulatory control the NNFL can be used as part of a nuclear forensics investigation to help identify whether or not the material is consistent with a country’s national holdings. In previous work, a number of signatures which can be useful to identify sealed sources of 241 Am were investigated. To validate the measurement results, an official query concerning information about two of the previously investigated 241 Am sources was sent to the United States Department of State, the international point-of-contact (POC) for the U.S. NNFL. The aim of this work is to show how data obtained in a characterization of a radioactive source can be used in conjunction with an NNFL to investigate the history of a source out of regulatory control.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Using high pressure solutions of polyfluoroacrylate and CO 2 to Seal cement cracks for improved wellbore integrity

Polyfluoroacrylate (PFA) is a hydrophobic and oleophobic polymer that is soluble in high pressure carbon dioxide (CO 2 ). In this study, the ability of PFA-CO 2 solutions to greatly reduce the apparent permeability of split or cracked Portland cement cylindrical samples is assessed. The apparent permeability values of confined samples were determined before and after treatment with PFA-CO 2 solutions. In four tests, PFA-CO 2 solutions were continuously displacing pure CO 2 from the cracked cement and the decrease in apparent permeability due to PFA adsorption and wettability alteration was monitored. The lowest apparent permeability cracked cement sample (81 nD) was completely sealed with a very small amount of solution. Samples with initial apparent permeabilities of 89 μD and 29.4 mD exhibited 92% and 99% reductions in permeability, respectively, before the experiments had to be stopped because of the excessively large increase in pressure drop. A 50% reduction in apparent permeability was observed with a 3.80 mD sample. Four other split cement samples (bound together with tape) with an initial apparent permeability in the 9.0–70 mD range were removed from the core holder and immersed in a PFA-CO 2 solution for 24 h to allow for PFA adsorption. Then the PFA-CO 2 solution was depressurized, allowing for the deposition of additional PFA from the solution within the crack as the pressure fell below the cloud point pressure of the PFA-CO 2 solution. These four samples were then confined again in a core holder and apparent permeability reductions of 29–93% were observed. Finally, results from these eight experiments indicates that the more substantial reductions in the nD – mD apparent permeability of the cracked cement correlated to lower initial crack permeability, higher PFA concentration, and slower injection rate of the PFA-CO 2 solution into the crack.

58 GEOSCIENCES↗

Numerical assessment of fault impact on caprock seals during CO 2 sequestration

Coupled fluid-flow and geomechanical analysis of caprock integrity has gained a lot of attention among scientists and researchers investigating the long-term performance of geologic carbon storage systems. Reactivation of pre-existing fractures within the caprock or re-opening of faults can create permeable pathways which can influence the seal integrity. Stability of the caprock during and after injection of super-critical CO 2 , and the impact of pre-existing fractures in the presence or absence of one or multiple faults have been investigated in this study. The impact of the wellbore orientation and the injection rate are among other key factors in understanding the structural trapping mechanisms within such geological formations. In this study, we numerically investigated the impact of each of these factors. This study revealed the interplay between joints and faults and how different leakage pathways are formed and under which scenario they play a dominant role in terms of CO 2 leakage. Finally, this study also highlights the role of one versus multiple faults in the domain and the importance of the fault hydrological property in forming leakage pathway.

58 GEOSCIENCES↗

Polarizing 3 He via metastability exchange optical pumping using a 1.2 mbar sealed cell at magnetic fields up to 5 T

Here, we report high nuclear polarization of 1.2 mbar 3 He gas in a sealed cell in magnetic fields up to 5 T using Metastability Exchange Optical Pumping (MEOP). The creation of a highly polarized 3 He gas target for use in the 5 T field of Jefferson Lab’s CLAS12 spectrometer would enable new studies of spin-dependent asymmetries on the neutron. We describe a systematic study which was conducted for the first time up to the full 5 T field required for the final target design to evaluate the effects of discharge intensity, pump laser power, and optical pumping transition schemes on nuclear polarization and pumping rates. Steady-state polarizations up to 86% in magnetic fields between 2 and 5 T were achieved, with a discharge-on relaxation time of 898 s at 5 T. These results underscore the potential of MEOP for high-field applications in nuclear physics experiments.

3He polarization↗

Multifunctional Silk Fibroin Hydrogels with Strong Adhesion for Tissue Sealing and Wearable Electronic Sensors

Multifunctional hydrogels with excellent adhesion, biodegradability, and conductivity are essential for overcoming the obstacles of postoperative secondary injury, flexible sensing instability, and so on. Herein, we develop a multifunctional silk fibroin (SF) hydrogel modified with poly(acrylic acid). Owing to the stable chemical cross-linking network and the abundant carboxylic acid groups of the SF network, the SF hydrogel exhibits a high tensile strength of 74.34 kPa due to sufficient cohesion and interfacial interactions. Additionally, the tensile strain reaches a maximum of 414.6%, the compressive strength is 0.9 MPa, and the shear adhesive strength for pig skin tissues is as high as 64 kPa. Compared with most hydrogels, our multifunctional SF hydrogel with a low swelling ratio provides excellent adhesion, biodegradation, and conductivity, which shows advantages in terms of invasive tissue sealing. Furthermore, the use of self-adhesive SF hydrogels as conductive hydrogels in flexible sensors also benefits the collection of physiological electricity and human motion signals in the field of wearable and implantable electronic devices.

adhesive↗

Performance of 3 cm 3 ion trap vacuum package sealed for 10 years

Miniature atomic clocks based on the interrogation of the ground state hyperfine splitting of buffer gas cooled ions confined in radio frequency Paul traps have shown great promise as high precision prototype clocks. We report on the performance of two miniature ion trap vacuum packages after being sealed for as much as 10 years. We find the lifetime of the ions within the trap has increased over time for both traps and can be as long as 50 days. We form two clocks using the two traps and compare their relative frequency instability one with another to demonstrate a short-term instability of 5×10 -13 $τ$ -1/2 integrating down to 1×10 -14 after 2 ks of integration. The trapped ion lifetime and clock instability demonstrated by these miniature devices despite only being passively pumped for many years represents a critical advance toward their proliferation in the clock community.

74 ATOMIC AND MOLECULAR PHYSICS↗

Vented and sealed cookoff of powdered and pressed ε-CL-20

In this work, we have completed a series of vented and sealed cookoff experiments of the ε-polymorph of CL-20 in our Sandia Instrumented Thermal Ignition (SITI) apparatus using both powder and pressed pellets at nominal densities of 313 ± 8 kg/m 3 and 1030 ± 4 kg/m 3 , respectively. The boundary temperature of our aluminum confinement cylinder was ramped in 10 minutes from room temperature to a prescribed set-point temperature ranging between 448 nd 468 K and held at the set-point temperature until ignition. A universal cookoff model (UCM) has been calibrated using the ε-CL-20 SITI data to predict pressurization and thermal ignition of ε-CL-20. The ignition model was validated by using one-dimensional time-to-explosion (ODTX) ignition data from a different laboratory. We found that a thirtyfold increase in the reaction rates due to liquefaction at 520 K could explain the high temperature ODTX cookoff data. The model gives a plausible explanation of why melting is important in fast cookoff events involving CL-20. Our model also gives support to 520 K as the liquefaction point of CL-20, which has different values in the literature.

36 MATERIALS SCIENCE↗

Extended Accelerated Stress Testing of Lamination-Free Edge-Sealed Photovoltaic Minimodules

Lamination-free minimodules are constructed with silicon solar cells between glass sheets and an edge seal of polyisobutylene and silicone. These samples are stressed using a repeated sequential testing sequence including ultraviolet-containing simulated solar spectrum light exposure at elevated temperature, damp heat, humidity freeze, and thermal cycling adapted from the International Electrotechnical Commission (IEC) TS 63209-2:2022. The minimodule performance throughout the stressing is characterized by flash testing and electroluminescence imaging. Results are compared to conventional laminated minimodules using the same type of solar cells. The lamination-free minimodules experience up to 8% power loss compared to roughly 3% for the laminated versions. However, those losses, dominated by current and fill factor, are caused by glass soiling and busbar ribbon separation on the cells. When glass is replaced and the stressed cells are contacted with probes bypassing the delaminated ribbons, the initial performance is recovered, and overall losses of the lamination-free samples become negligible.

14 SOLAR ENERGY↗

ISGS Seal wells

Computed tomography and core logger data described in Technical Report "Computed Tomography Scanning and Geophysical Measurements of the CarbonSAFE Seal Integrity Wells in the Illinois Basin" by Paronish et al., 2023

carbon storage↗

Sealed Vessel Leak Test [Slides]

A test plan has been developed to verify the results obtained from sealed vessels used in support of the JT5-Alt370-IN-1 compatibility testing. The test plan needs to be verified by doing a mock test on testing vessels, it will be adjusted and redone as necessary then conducted on the remaining vessels from the compatibility tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Lambda Plate Seal for HFVMTF Anticryostat

Fermilab is currently designing a High Field Vertical Magnet Test Facility in order to test superconducting cables and magnets. The goal of this project was to analyze the thermal performance of three different seal designs and provide recommendations for the HFVMTF.

Gasior, Brett↗

Engineering Evaluation of Barium Buildup in a Decayed CsCl Sealed Source and Potential Impact for Cesium Release from a Breached Source

For more than 50 years, radioactive 137 Cs has been a major source material for radioactive sealed sources, usually constructed as cesium chloride (CsCl) salt loaded into double-walled, stainless-steel capsules. A complication develops as 137 Cs decays to 137 Ba since this process creates a strongly reducing environment inside the capsule. A potential hazard exists if the capsule is breached and air ingress induces rapid exothermic oxidation, and this mechanism is suspected to be responsible for the well-known contamination incident at the Harbor View facility in Washington state. For this study, many thermodynamic evaluations were performed to assess the internal state of capsules after several decades of decay and to describe the potential oxidation if the capsule contents were to suddenly be exposed to air. Results suggest that reduction of impurities such as Cu, Fe, Pb, and Cr to metal will occur. If these impurities are lacking, it is possible that even Ba metal will form. In most cases, rapid oxidation can occur, and the exothermic reactions are sufficient to vaporize portions of the contents, which would include the remaining 137 Cs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

H-Canyon Jumper Gasket Sealing Evaluation

H-Canyon Documented Safety Analysis approved December 2019 credits the leak integrity of HCanyon (HCA) process tanks, piping, and jumpers in preventing the release of radioactive material in a post seismic environment. Demonstration of leak tightness capability for this equipment was achieved through substantial analytical effort. However, one potential weak point that affects leak integrity exists at the gasketed joint between Hanford Connectors (HC) and nozzles. Review of the HCA Crane Log over a three-year period indicates the HCs periodically leak. Savannah River National Laboratory (SRNL) was requested to perform gasket compression tests that evaluate gasket relaxation characteristics, i.e., creep, and provide improvements to the HC installation process that can reduce or eliminate the frequency of leaks at HCs. A HC torque value of 312 ft-lbf is the target value used because it is the minimum torque value, with 95% confidence, when an unlubricated HC is impacted for standard sealing period of 9 seconds.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Forensic Examinations in Support of Breach Sealed Source Event at Harborview Medical Facility on 2 May 2019

On May 2, 2019, International Isotopes, Inc. (INIS), a subcontractor to Triad National Security, LLC (contractor for Los Alamos National Laboratory) breached a sealed radioactive source containing ~2800 Ci of the radioactive isotope cesium-137 ( 137 Cs) at the University of Washington Harborview Research and Training (HRT) Building in downtown Seattle while attempting to recover the source for the National Nuclear Security Administration’s (NNSA’s) Off-site Source Recovery Program (OSRP). The breach of the source resulted in the contamination of 13 personnel, all 7 floors of the building, and a release of material to the environment. A summary of root and contributing causes of the event was investigated and published by a joint investigation team (JIT) co-led by NNSA and Triad National Security, LLC. That investigation was supported by forensics examinations provided by Pacific Northwest National Laboratory. This report summarizes the results of those forensic examinations.

61 RADIATION PROTECTION AND DOSIMETRY↗