Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “scintillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

Parameters of fast and high-yield InAs/GaAs quantum dot semiconductor scintillator

InAs quantum dots (QDs) embedded into a waveguiding GaAs semiconductor matrix may produce scintillation detectors with exceptional speed and yield, making them valuable for nuclear security, medical imaging, and high energy physics applications. In this work, we developed thick (~25 μm) epitaxial heterostructres with high luminescence efficiency composed of self-assembled nano-engineered InAs QDs grown by molecular beam epitaxy. Here, the bulk GaAs acts as a stopping material for incident particles and as a waveguide when layer-transferred onto a low-index substrate. Waveguiding and self-absorption (< 1 cm –1 ) were studied using photoluminescence with scanning laser excitation and modeled with ray optics approximation and geometrical coupling of high-index waveguide to a collection fiber. Scintillating signals from α-particles were analyzed with an external photodiode (PD) and an integrated PD which provided an improved optical coupling. The mean charge collected by the integrated PD corresponded to 3 × 10 4 photoelectrons per 1 MeV of deposited energy, or ~13% of the theoretically achievable light yield. Combined with the previously measured QD scintillation time of 0.3-0.6 ns, this makes the InAs/GaAs QD heterostructures the fastest high yield scintillation material reported.

36 MATERIALS SCIENCE↗

Unattended Monitoring of Uranium Holdup with Scintillating Fibers

This work evaluated the use of scintillating fiber (SciFi) radiation sensors as a cost-effective, unattended monitoring technique for uranium holdup accumulation in reprocessing equipment. With ruggedized packaging and an outer diameter of less than 1 cm, scintillating fibers offer deployment flexibility. Additionally, plastic scintillating fibers coupled with standard optical fibers provide an affordable option to monitor locations kilometers away from a localized control room or data acquisition (DAQ) system. These combinations of characteristics along with their relatively low manufacturing costs make scintillating fibers ideal for installation at key measurement points such as pipes, valves, and filtration systems.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Assessment of Thin Plastic Scintillation Detectors for Beta-Particle Measurements at the Advanced Test Reactor Critical Facility

The Fission Wire Measurement System is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical facility. The Advanced Test Reactor Critical facility is an open-pool, low-power test reactor used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in the Advanced Test Reactor. Power distribution measurements in ATR-C use uranium-aluminum wires that are distributed throughout the core to validate simulation and modeling results. These measurements require from 340 to 1500 wires to be irradiated and measured within a 12-hour window. The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. The gas flow detectors are of a custom design for this detector system that use methane gas with a large anode wire compared to modern proportional counters. These detectors, which are nearly 60 years old are irreplaceable. The measurements from these gas detectors are affected by the gas flow rate, atmospheric and line pressure, and are very sensitive to the applied high voltage. Recent improvements have been made to the control and data acquisition system, but the detectors have remained the same. The nature of the measurement of the fission product decay activity is such that the energy spectrum of the signal is changing with time. Thin, 250-um thick, plastic scintillators were commercially obtained as a potential replacement for the gas flow detectors. The original calibration of the uranium-aluminum fission wires was conducted in 1965 using a series of irradiations of gold foils and the wires in a well-characterized thermal neutron field. These measurements provided a time-dependent fission rate conversion factor from the gold foil data to calibrate the fission wires based on the response from the 2-pi proportional gas detectors. Transitioning to the new detectors requires qualification and testing. The sensitivity of the scintillators to changes in the energy spectrum of the fission wires and translation of the calibration factor have been completed. These measurements indicated that the sensitivity of the scintillators over time changes at a different rate than the sensitivity of the gas flow detectors. However, the inverse activity of measurements of both detector types is linear with time. Initial results indicate that the scintillator detectors will be a sufficient replacement for the gas detectors with minor adjustments to the fission rate conversion factor. Replacement of the detectors will improve the fission wire measurements and provide a more stable and reliable measurement system.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Neutrino identification with scintillation light in MicroBooNE

MicroBooNE is a neutrino experiment which employs a liquid argon (LAr) time projection chamber (TPC) to record neutrino interactions from Fermilab's neutrino beamlines. The experiment's primary objective is to study low-energy νe interactions from the Booster Neutrino Beamline (BNB). Located on the surface, the detector is affected by a continuous rate of cosmic-rays. This leads to one neutrino interaction for every 104 cosmic rays observed in the TPC, making it difficult to isolate neutrino interactions in the detector using charge alone. MicroBooNE's trigger makes use of prompt scintillation light and plays an essential role in both performing strong background rejection and significantly reducing data-rates. Furthermore, a series of novel techniques relying on scintillation light are used to isolate beam-induced activity. This document briefly presents MicroBooNE's scintillation-light based trigger and novel Flash-Matching pattern recognition techniques for cosmic-rejection. This work serves as the foundation of neutrino analyses in LArTPC detectors and is therefore of interest to the broader short- and long-baseline neutrino programs being launched at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron detection efficiency measurements of organic glass scintillator arrays

We characterize the neutron detection efficiency of pixelated organic glass scintillator (OGS) arrays manufactured in two ways: an additive method in which the OGS is cast in place in a pixelated mold, and a subtractive method in which the scintillator is first cast as a large block before being cut in bars and bonded together to form the array. The cast-in-place array utilizes a mixture of “bis(9,9-dimethyl-9H-fluoren-2-yl)diphenylsilane” (P2), “tri([1,1'-biphenyl]-4-yl)(phenyl)silane” (PB3), and “4-bis(2-methylstyryl)benzene” (MSB), and 50% by weight of polystyrene is added to the mixture for subtractive manufactured array. We compare the performance of the OGS arrays to that of an EJ-299-33M plastic scintillator array that was manufactured using a subtractive process similar to that of the second OGS array.

Neutron detectors (cold, thermal, fast neutrons)↗

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗

Advanced high-performance large diameter Cs 2 HfCl 6 (CHC) and mixed halides scintillator

This paper reports on successful growth and performance evaluation of two large diameter Cs 2 HfCl 6 (CHC) and Cs 2 HfCl 4 Br 2 (CHCB), both recently developed scintillator crystals. The discovery of Cs 2 HfCl 6 (CHC) as a scintillator has lately generated much interest in this material and its family, which belongs to the K 2 PtCl 6 cubic crystal structure. CHC is an intrinsic scintillator that is non-hygroscopic (slightly deliquescent, i.e., slightly moisture sensitive but does not deteriorate much when left in air), has no self-radioactivity, provides excellent energy resolution, and has excellent non-proportionality. CHC has a moderate density of 3.9 g/cm 3 and an effective atomic number of 58. Reported in this paper are transparent crack-free single crystal CHC and CHCB boules of one inch in diameter, both grown using the vertical Bridgman method. Samples retrieved from the boules, sized 23 mm × 30 mm and 23 mm × 26 mm, respectively, are characterized for their optical and scintillation properties. Energy resolutions of 3.5% and 3.7% (FWHM) at 662 keV, respectively, are reported. Light yields of 23,000 ph/MeV and 20,000 ph/MeV have been calculated for the large diameter CHC and CHCB crystals, respectively. Results comparable to previously reported results for smaller crystals have been obtained. Studies on decay time, non-proportionality, as well as detector characterization are also reported.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A prototype for SANDD: A highly-segmented pulse-shape-sensitive plastic scintillator detector incorporating silicon photomultiplier arrays

We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 × 8 array of plastic scintillator segments coupled to two 5 cm × 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will eventually comprise a central module of 64 elongated segments of 6 Li-doped pulse-shape-sensitive scintillator rods, each with a square cross section of 5.4 mm × 5.4 mm, surrounded by larger cross section bars of the same material. The most important metrics with the potential to impact the performance of the central module of SANDD are neutron and gammaray pulse-shape sensitivity using silicon photomultipliers (SiPMs), particle identification via scintillator rod multiplicity, and energy and position resolution. As a first step, we constructed a prototype detector to investigate the performance of a central SANDD-like module using two 64-channel SiPM arrays and rods of undoped pulse-shape-sensitive plastic scintillator.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiple dye interactions in plastic scintillators: Effects on pulse shape discrimination

The scintillation process in plastic scintillators has been studied with mixed systems containing high concentrations of multiple fluorescence dyes. It has been shown that the triplet–triplet interaction phenomena leading to the production of delayed light and pulse shape discrimination (PSD) can vary depending on the triplet energies of the interacting dyes. At small differences between the first excited triplet state energies, found to be below 0.1 eV, a pair of interacting dyes of different molecular species can be involved in heterogeneous excitation migration and triplet–triplet annihilation that result in the enhancement of delayed light and PSD, due to the engagement of both dyes in the process. At differences above 0.27 eV, excitation trapping on the lower energy triplet molecules leads to conditions when triplet–triplet migration and annihilation can proceed only homogeneously between molecules of the same species. The results explain the different effects produced by the selection of fluorescent dyes in previously reported PSD systems containing one primary and one secondary dyes. They also demonstrate a non-traditional approach to the design of new plastic scintillators with multiple dyes that, at improved scintillation and PSD performance, may simplify the production process.

36 MATERIALS SCIENCE↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an optical sensor for measuring opacity changes in polyvinyl toluene scintillators

Polyvinyl toluene (PVT) based detectors are used in radiation portal monitors (RPMs) worldwide to detect the trafficking of illicit nuclear material. PVT scintillators, which are normally optically clear, have been observed to suffer internal fogging throughout their volume due to prolonged exposure to varying environmental conditions. These changes could lead to reduced performance for RPMs that utilize plastic scintillators. In this research, a proof of concept system, consisting of different color light emitting diodes (LEDs) and a single optical sensor (OS), were used to examine the change in light transmission through a PVT scintillator. This Optical Monitoring System (OMS), coupled with an environmentally exposed PVT detector, was tested in an environmental chamber where it was subjected to changes in temperature and humidity ranging from 55 °C at 100% relative humidity to –20 °C at 40% relative humidity. At temperatures below 10 °C, light transmission was reduced by 81% ± 8% for blue LEDs, 84% ± 5% for yellow LEDs, and 49% ± 4% for green LEDs. Similar reductions in detected light were not recorded when the OMS was tested with only air between the LEDs and OS. Therefore, the significant reductions in transmitted light were attributed to changes occurring within the PVT scintillator. These results indicate that a significant reduction in PVT opacity occurs due to wide environmental changes. A device such as the OMS could be used to track these changes and provide users an early indication that a portal monitor is suffering from reduced performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LumaCam: a novel class of position-sensitive event mode particle detectors using scintillator screens

A new type of position-sensitive detectors is gaining attention in the neutron community. They are scintillator based detectors that detect the scintillation light on an individual photon basis via an image intensifier and a fast image sensor. Their readout operates in event mode i.e. it produces information about individual neutron interactions, reconstructed from the sensor data, thus enabling to achieve superior spatial and temporal resolutions compared to regular detectors. Although the development of current detectors is focused on neutrons, the concept is also applicable to the detection of other particles such as high-energy photons. This document provides a description on how these detectors are built, how they operate, and what their characteristics are. An example of a detector implementation based on a Timepix3 chip is described to illustrate the detector concept. This includes a detailed description of the algorithm that reconstructs the neutron interactions from the sensor data, one of the core components that sets it apart from established scintillator-based imaging detectors. Energy-resolved epithermal neutron radiography was performed at the ISIS EMMA beamline with this detector, illustrating some of the fundamental differences in the data that can be produced with the new type of detector compared to more established types of scintillator based neutron detectors. The term LumaCam is proposed to refer to this new class of position-sensitive event-mode detectors.

47 OTHER INSTRUMENTATION↗

Strip-based Scintillation Detector for Dual-readout High-granularity Calorimetry

New calorimeter technology is being developed for future collider experiments. We are developing a calorimeter that integrates two technologies, a high-granularity calorimeter and a dual-readout calorimeter, and has high time resolution at a picosecond level. The proposed calorimeter is a sampling calorimeter based on scintillation and Cherenkov detectors with high-granularity readout. The Cherenkov detector has a picosecond level time resolution. For the high-granularity scintillation detector, scintillator strips of 300mm × 30mm ×3mm-thick are aligned horizontally and vertically to realize an effective 30mm-square-cell segmentation. Prototype strips with different designs and scintillator materials were tested to compare the performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DIREXENO—an apparatus for measuring correlated scintillation signatures in liquid xenon

We present a detector apparatus, DIREXENO (DIREctional XENOn), designed to measure the spatial and temporal properties of scintillation in liquid xenon to very high accuracy. The properties of scintillation are of primary importance for dark matter and neutrinoless double beta decay experiments; however the complicated microphysics involved limits theoretical predictions. We will explore the possibility that scintillation emission exhibits spatial correlations such as super-radiance which manifests in temporal and spatial structure, depending on the interaction type. Such properties of scintillation light may open a new window for background rejection as well as directionality measurements. We present the apparatus' technical design and the concepts driving it. We demonstrate that for an energy deposition of ~2.5 keV (~7.5 keV) electron (nuclear) recoil the detector is sensitive to an anisotropy fraction of as little as ~ 20% of the total photons emitted over a solid angle of ~0.85 steradian or less. We show results from commissioning runs in which the detector operated with 17 PMTs for over 44 days in stable conditions. The time resolution for individual photons in different PMTs was measured to be ≲1.4 ns full-width at half-maximum

47 OTHER INSTRUMENTATION↗

Analysis of scintillation light dependence on Liquid Argon purity in the ICARUS detector

Previous studies have investigated the correlation between impurities concentration in Liquid Argon (LAr) and the temporal evolution of either the slow scintillation decay time or the light yield.These impurities typically consist of various molecular species. Electronegative contaminants directly affect electron drift and photon production, while other molecules, such as nitrogen (N$_{2}$), can influence LAr scintillation properties without necessarily affecting electron lifetime.Many current and future neutrino and dark-matter experiments use LAr detectors. This study aims to evaluate the measured electron lifetime in relation to the timing characteristics of the scintillation light signal in the SBN ICARUS detector at Fermi National Accelerator Laboratory. The ICARUS detector consists of two cryostats that have shown different behaviors in the measured electron lifetime over the years. In particular, this study addresses the use of data collected under varying purity conditions in the two cryostats and presents the methodology used to extract scintillation timing characteristics and their correlation with LAr purity.

Saia, C. [Catania Astrophys. Observ.] (ORCID:00090↗

Neutron and Gamma-Ray Imaging of Th-232 and Cm-244 Using Organic Glass Scintillators

Modern nuclear safeguards require detection and characterization capabilities suitable for a wide variety of radiation sources and applications. Field-deployable detection systems have also had to modernize to meet changing needs. Recent developments in organic scintillator technology have resulted in the creation of an organic glass scintillator (OGS) at Sandia National Laboratory which is composed of a 9:1 mixture of glass compounds C42H36Si and C51H44Si. The novel scintillator composition was implemented into the design for a dual-particle capable imaging system at the University of Michigan. This work presents new results from two experiments demonstrating the gamma-ray and fast-neutron imaging capabilities of the organic glass system. Gamma spectroscopy was also performed using CeBr3 scintillators that are part of the imager design. Measurements were performed at Lawrence Livermore National Laboratory using 232Th metal hemishells and an encapsulated 244Cm oxide source. Successful gamma-ray imaging of the 232Th distributed sources is demonstrated with the glass imager, but there were no appreciable neutrons from the 232Th for neutron imaging. Promising neutron and gamma-ray imaging results of 244Cm are demonstrated despite limited imaging event statistics available in this measurement. Gamma-ray spectroscopy results were able to identify 232Th using prominent emissions at 239, 338, 583, and 911 keV. 244Cm was identified from emissions of 43, 99, and 153 keV. These results demonstrate the potential of organic glass imaging for nuclear nonproliferation or characterization efforts.

Lopez, Ricardo [Univ. of Michigan, Ann Arbor, MI (↗

Mixed Material Scintillator Systems (Quarterly Report FY20Q3)

This project aims to invent, model, and prototype mixed-material scintillator systems (MMSSs), a new class of radiation detectors that use heterogenous internal structures of different scintillating materials to detect additional properties of radiation. These internal structures can be produced using additive manufacture (3D printing) of scintillator, a currently emerging application of additive manufacture technology. MMSSs combine the low cost and complexity of conventional scintillation detectors with capabilities currently only available in more expensive and complex detectors. By identifying promising MMSS designs, this project will enable a new class of detectors to meet DNN’s mission needs for SNM detection.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗