Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “saving energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Evaluation of Uplight Energy Saving Actions Using ResStock TM (Summary of Results)

As part of a portfolio of product offerings, Uplight produces energy savings estimates to inform a utility’s residential customers of the expected benefits that would arise from adopting energy efficiency measures, which are termed “energy saving actions. ”Uplight’s current practice is to use a proprietary building simulation model to estimate energy and cost benefits from these actions, as discussed in Maguire et al. Uplight requested that the National Renewable Energy Laboratory (NREL) provide an independent estimate of the energy savings for a defined list of energy saving actions. NREL performed this study using two established building energy simulation tools: EnergyPlus ® ( EnergyPlus ) and ResStock TM .(

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FlexiWay: A Cache Energy Saving Technique Using Fine-grained Cache Reconfiguration

Recent trends of CMOS scaling and use of large last level caches (LLCs) have led to significant increase in the leakage energy consumption of LLCs and hence, managing their energy consumption has become extremely important in modern processor design. The conventional cache energy saving techniques require offline profiling or provide only coarse granularity of cache allocation. We present FlexiWay, a cache energy saving technique which uses dynamic cache reconfiguration. FlexiWay logically divides the cache sets into multiple (e.g. 16) modules and dynamically turns off suitable and possibly different number of cache ways in each module. FlexiWay has very small implementation overhead and it provides fine-grain cache allocation even with caches of typical associativity, e.g. an 8-way cache. Microarchitectural simulations have been performed using an x86-64 simulator and workloads from SPEC2006 suite. Also, FlexiWay has been compared with two conventional energy saving techniques. The results show that FlexiWay provides largest energy saving and incurs only small loss in performance. For single, dual and quad core systems, the average energy saving using FlexiWay are 26.2%, 25.7% and 22.4%, respectively.

Cache leakage energy saving↗

Practices for Demonstrating Energy Savings from Commercial PACE Projects

Nearly three-fourths of U.S. states have authorized local governments to use voluntary special assessments on commercial properties to finance energy improvements that boost economic development, create jobs, increase property values and advance energy goals. Commercial Property Assessed Clean Energy (C-PACE) financing allows building owners to repay the borrowed capital — from private or public sources — over time using their property as security. Berkeley Lab is supporting the Department of Energy’s Commercial PACE Working Group by developing a series of C-PACE issue briefs. The second brief in this series, Practices for Demonstrating Energy Savings from Commercial PACE Projects, looks at common practices for demonstrating energy savings to support state and local governments that sponsor C-PACE programs and want to track their energy impacts. This brief reviews: -The value proposition and trade-offs of conducting energy impact assessments for C-PACE programs; -Methods to quantify energy savings impacts from energy efficiency building improvements; and -Available resources and tools to support energy impact assessments. C-PACE programs may benefit from energy impact assessments for many reasons, including: -Validating the public benefits of the programs -Demonstrating that C-PACE can deliver participant benefits -Illustrating program impacts on public policy goals -Generating data to help improve program performance Many C-PACE programs are collecting data on project energy savings impacts, and these data can be leveraged to further support decision making and program implementation. Potential drawbacks to energy impact assessments may include added cost and burdens on property owners (e.g., the need to collect building energy consumption data). Where these burdens are considerable, they might slow program uptake. State and local governments can balance the benefits of energy impact assessments with the range of costs and accuracy inherent to available assessment methodologies. Additionally, depending on the policy context in the state or local government, a C-PACE program may be able to leverage existing efforts (e.g., building energy benchmarking programs) to reduce impact assessment costs, align with building owner practices and expectations, and efficiently assess program impact.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Aerodynamic Drag and Drag Reduction: Energy and Energy Savings (Invited)

An assessment of the role of fluid dynamic resistance and/or aerodynamic drag and the relationship to energy use in the United States is presented. Existing data indicates that up to 25% of the total energy consumed in the United States is used to overcome aerodynamic drag, 27% of the total energy used in the United States is consumed by transportation systems, and 60% of the transportation energy or 16% of the total energy consumed in the United States is used to overcome aerodynamic drag in transportation systems. Drag reduction goals of 50% are proposed and discussed which if realized would produce a 7.85% total energy savings. This energy savings correlates to a yearly cost savings in the $30Billion dollar range.

Wood, Richard M.↗

Aerodynamic Drag and Drag Reduction: Energy and Energy Savings (Invited)

An assessment of the role of fluid dynamic resistance and/or aerodynamic drag and the relationship to energy use in the United States is presented. Existing data indicates that up to 25% of the total energy consumed in the United States is used to overcome aerodynamic drag, 27% of the total energy used in the United States is consumed by transportation systems, and 60% of the transportation energy or 16% of the total energy consumed in the United States is used to overcome aerodynamic drag in transportation systems. Drag reduction goals of 50% are proposed and discussed which if realized would produce a 7.85% total energy savings. This energy savings correlates to a yearly cost savings in the $30Billion dollar range.

Wood, Richard M.↗

Optimizing PCM-integrated walls for potential energy savings in U.S. Buildings

Buildings in the United States account for nearly half of total U.S. energy use. The energy used for space conditioning can be reduced by utilizing thermal energy storage, such as phase change materials (PCMs), into building envelopes; however, the energy savings of PCM-integrated building envelopes reported in the literature vary widely. In the absence of established guidelines, thermophysical requirements of an optimal PCM, its method of application into the building envelope, and the corresponding energy savings under various climates remain unknown. Here, we perform an extensive numerical investigation on the integration of PCM into building walls to establish the key conditions required for effective utilization of PCM in reducing heat gains in the cooling season and heat losses in the heating season. We also determine the optimal transition temperature, optimal PCM location in the wall, and the energy-saving potential of the PCM-integrated building walls in five U.S. cities located in different International Energy Conservation Code climate zones. Results show that employing PCMs in building walls does not always lead to an improvement; in fact, incorrect applications of PCMs can substantially increase energy use in the buildings. In the climates we studied, PCMs were found effective in reducing heat gains during the cooling season while mostly ineffective in managing heat losses during heating season. Depending on the climate, optimized PCMs in U.S. building walls can provide reduction in the annual heat gain in the range of 3.5% to 47.2% and the annual heat loss in the range of -2.8% to 8.3%. Future consideration of buildings with substantial solar gains in winter may lead to more reduction in heat losses by PCMs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Potential of SSL in Agricultural Applications

A report on the energy-savings potential of solid-state lighting in agricultural applications, which updates a prior edition that focused on horticultural lighting only, with an expanded focus that includes animal lighting. The analysis considered three indoor horticultural lighting categories: lighting supplemented greenhouses, high intensity sole-source farms, and sole-source indoor vertical farms typically growing leafy greens. To characterize animal lighting, the analysis investigated the three largest markets of livestock in the U.S. that use lighting – poultry, swine, and dairy farming. To estimate energy consumption of agricultural lighting, the analysis utilized interviews with lighting manufacturers, growers, utility companies, academic professionals, and industry consultants, as well as various data sources. Each of these resources enabled the determination of total market size and illuminated area, typical lighting configuration, lighting power density for LED and incumbent technologies, operating hours, and the installed lighting technology mix. Among the major findings: 1. If all indoor horticultural lighting today was converted to LED technology, annual horticultural lighting consumption would be reduced to 6.3 TWh of site electricity, or 60 tBtu of source energy, which represents lighting energy savings of 34% or $350 million. 2. If all animal lighting today was converted to LED technology, annual lighting energy consumption for animal production would be reduced to 2.8 TWh site electricity, or 26 tBtu of source energy, which represents lighting energy savings of 25% or $96 million.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Opportunities in Highway Lodging Buildings: Development of 50% Energy Savings Design Technology Packages

This paper presents the process, methodology, and assumptions for development of the 50% Energy Savings Design Technology Packages for Highway Lodging Buildings, a design guidance document that provides specific recommendations for achieving 50% energy savings in roadside motels (highway lodging) above the requirements of ANSI/ASHRAE/IESNA Standard 90.1-2004. This 50% solution represents a further step toward realization of the U.S. Department of Energy’s net-zero energy building goal, and go beyond the 30% savings in the Advanced Energy Design Guide series (upon which this work was built). This work can serve as the technical feasibility study for the development of a 50% saving Advanced Energy Design Guide for highway lodging, and thus should greatly expedite the development process. The purpose of this design package is to provide user-friendly design assistance to designers, developers, and owners of highway lodging properties. It is intended to encourage energy-efficient design by providing prescriptive energy-efficiency recommendations for each climate zone that attains the 50% the energy savings target. This paper describes the steps that were taken to demonstrate the technical feasibility of achieving a 50% reduction in whole-building energy use with practical and commercially available technologies. The energy analysis results are presented, indicating the recommended energy-efficient measures achieved a national-weighted average energy savings of 55%, relative to Standard 90.1-2004. The cost-effectiveness of the recommended technology package is evaluated and the result shows an average simple payback of 11.3 years.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probabilistic reliability assessment and case studies for predicted energy savings in residential buildings

This study aims to (1) investigate the key influential parameters (KIPs) in estimating the uncertainty of energy savings using a residential building energy simulation model and (2) perform uncertainty quantification for energy savings for several different scenarios. The proposed methodology was successfully applied to the calculation of uncertainties associated with residential energy retrofits using two test houses designed for pre- and post-retrofit cases. Uncertainties were determined using basic parameters that might be supplied to an energy model and then reevaluated based on an audit of the KIPs identified, resulting in substantially reduced uncertainty. Of four different scenarios, the most uncertain scenario estimated the annual energy savings from the retrofit would be between 18% and 51% at a 95% confidence level, and the least uncertain scenario estimated the annual savings would be between 26% and 40% at a 95% confidence level. The actual measured annual savings from the two test houses was 28%, which shows an agreement with the uncertainty analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings and Breakeven Cost for Residential Heat Pump Water Heaters in the United States

Heat pump water heaters (HPWHs) have recently reemerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, simulations were performed of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern US. When replacing an electric water heater, the HPWH is likely to break even in California, the southern US, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Results from Small Commercial Building Retrofits in the US

Small commercial buildings, or those comprising less than 50,000 square feet of floor area, represent 94% of U.S commercial buildings by count and consume approximately 8% of the nation’s primary energy; as such, they represent a largely unexploited opportunity for energy savings. Small commercial buildings also represent a large economic market—the National Institute of Building Sciences (NIBS) estimated the small commercial retrofit market at USD 35.6 billion. Despite the prominence of small commercial buildings and the economic opportunity for energy retrofits, many energy efficiency programs focus on large commercial buildings, and create efficiency solutions that do not meet the needs of the small commercial market. This paper presents an analysis of 34 small commercial case study projects that implemented energy efficiency retrofits. This paper contributes to the existing building retrofit body of knowledge in the following ways: (1) it identifies the decision criteria used by small commercial building stakeholders that decided to complete an energy retrofit; (2) it identifies the most commonly implemented efficiency measures in small commercial buildings, and discusses why this is the case; and (3) it provides empirical evidence about the efficacy of installing single energy efficiency measures (EEMs) compared to packages of EEMs in small commercial buildings by reporting verified energy savings. To the authors’ knowledge, this paper is the first to catalog decision criteria and energy savings for the existing small commercial buildings market, and this research illustrates that small commercial building decision-makers seem most motivated to retrofit their spaces by energy cost savings and operational concerns. Furthermore, small commercial building decision-makers opted to implement single-system retrofits in fifteen (15) of the thirty-four cases studied. Finally, this research documents the improved savings, in the small commercial buildings market, associated with a more integrated package of EEMs compared to a single-system approach, achieving approximately 10% energy savings for a single-system approach and more than 20% energy savings for integrated approaches. These savings translate to CO2 savings of 1,324,000 kgCO2/year to 2,647,000 kgCO2/year, respectively, assuming small commercial buildings are retrofit at a rate of 0.95% of the stock annually.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Savings and Breakeven Costs for Residential Heat Pump Water Heaters in the United States

Heat pump water heaters (HPWHs) have recently re-emerged in the U.S. residential water heating market and have the potential to provide homeowners with significant energy savings. However, there are questions as to the actual performance and energy savings potential of these units, in particular in regards to the heat pump's performance in unconditioned space and the impact of the heat pump on space heating and cooling loads when it is located in conditioned space. To help answer these questions, NREL performed simulations of a HPWH in both conditioned and unconditioned space at over 900 locations across the continental United States and Hawaii. Simulations included a Building America benchmark home so that any interaction between the HPWH and the home's HVAC equipment could be captured. Comparisons were performed to typical gas and electric water heaters to determine the energy savings potential and cost effectiveness of a HPWH relative to these technologies. HPWHs were found to have a significant source energy savings potential when replacing typical electric water heaters, but only saved source energy relative to gas water heater in the most favorable installation locations in the southern United States. When replacing an electric water heater, the HPWH is likely to break even in California, the southern United States, and parts of the northeast in most situations. However, the HPWH will only break even when replacing a gas water heater in a few southern states.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Performance Contract (ESPC) ENABLE Program

The Energy Savings Performance Contract (ESPC) ENABLE program, a new project funding approach, allows small Federal facilities to realize energy and water savings in six months or less. ESPC ENABLE provides a standardized and streamlined process to install targeted energy conservation measures (ECMs) such as lighting, water, and controls with measurement and verification (M&V) appropriate for the size and scope of the project. This allows Federal facilities smaller than 200,000 square feet to make progress towards important energy efficiency and water conservation requirements.

Energy, Savings, Performance, Contract, ESPC, ENAB↗

Comparison of different simulation programs in modeling the energy savings of cool roofs

The Roof Savings Calculator is a web-based application first developed in 2010 that uses detailed building energy simulations to calculate the energy savings of cool roofs for different building types in over 200 U.S. locations. Although modeling the heat flows of a roof may be straightforward at first glance, modeling the energy savings due to changes in the roof albedo is complicated because it involves modeling the interzone heat transfer between the attic and the conditioned space below. Since direct measurement of energy savings is also problematic, the authors have decided to compare what several independent detailed simulation programs show for the energy savings from cool roof strategies.

Huang, Yu (Joe)↗