SEARCH · Engineering Papers
Results for “sample integrity”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Sub-Monolayer Accuracy in Determining the Number of Atoms per Unit Area in Ultrathin Films Using X-ray Fluorescence
We present that the composition and thickness of thin films determine their physical properties, making the ability to measure the number of atoms of different elements in films both technologically and scientifically important. For thin films, below a certain thickness, the X-ray fluorescence intensity of an element is proportional to the number of atoms. Converting this intensity to the number of atoms per unit area is challenging due to experimental geometries and other correction factors. Hence, the ratio of intensities is more commonly used to determine the composition in terms of element ratios using standards or a model. Here, the number of atoms per unit area was determined using X-ray structure information for over 20 different crystallographically aligned samples with integral unit cell thicknesses. The proportionality constant between intensity and the number of atoms per unit area was determined from linear fits of the background subtracted X-ray fluorescence intensity plotted versus the calculated number of atoms per unit area for each element. The results demonstrate that X-ray fluorescence is very sensitive, capable of measuring changes in the number of atoms of less than 1% of a monolayer for some elements in a variety of sample matrices. Finally, using the calibrated values, an 8 unit cell thick MoSe 2 was grown and characterized, demonstrating the usefulness of the ablity to quantify the number of atoms per unit area in a film.
Underground Test Area (UGTA) Sampling Plan for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada National Security Site, Nevada
The purpose of this groundwater sampling plan (referred to herein as “the Plan”) is to describe the approach for collecting and analyzing groundwater samples to meet the objectives of the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program’s Underground Test Area (UGTA) Activity. The Plan is focused on the Central and Western Pahute Mesa corrective action units (CAUs 101 and 102). The remaining UGTA CAUs are in the final stage of the UGTA strategy (Closure Report [CR] stage), and monitoring requirements for these CAUs are described in their respective CRs. The Plan supersedes the Nevada National Security Site Integrated Groundwater Sampling Plan and its ensuing Record of Technical Change (ROTC) (DOE/EMNV, 2019b). The Plan is designed to ensure compliance with the UGTA Quality Assurance Plan (QAP) and its ensuing ROTC (DOE/EMNV, 2018), and the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). The Plan is implemented by the Environmental Program Services (EPS) contractor. Implementation of the Plan provides data to complete corrective actions prescribed by the FFACO to protect the public from groundwater contaminated by historical underground nuclear testing. The Plan’s scope comprises sample collection and analysis requirements for assessing the extent of groundwater contamination from underground nuclear testing. Sampling wells located in the communities surrounding the Nevada National Security Site (NNSS) is performed by other organizations (e.g., management and operating [M&O] contractor) and is therefore not included within the Plan. The results of the community sampling are presented in the annual NNSS environmental reports.
Pattern-enhanced Resonant Soft X-ray Scattering for Operando monitoring of electrochemical solid-liquid interfaces
Unveiling interfaces at sub-nanometer scales is essential for advancing the understanding of complex chemical transformations. However, characterizing solid-liquid interfaces with high dimensional sensitivity and temporal resolution remains challenging, due to their dynamic nature and inaccessibility by conventional probes. Here we present an approach, Pattern-enhanced Resonant Soft X-ray Scattering, to overcome the challenges. Rooted in a “sample-as-optics” philosophy, this technique utilizes precisely engineered line-grating nanopatterns to modulate near-field X-ray illumination, coherently enhancing scattering signals from the line-gratings. We implement the method using Ni line-grating nanopatterns in electrochemical water oxidation. The periodic nanostructures serve as diffractive optical elements to reveal the Ni oxidation gradients and structural dynamics at the electrode-electrolyte interfaces. Finite-element simulations corroborate the observed trends by modeling variations in compositions and structures during electrocatalysis. Through integrating advanced sample design with coherent wave nature of soft X-rays, our approach opens accessible pathways to operando exploring chemical evolution and sub-nanometer dimensional variations simultaneously in electrochemical systems. This non-destructive method is efficient and element-specific, making it valuable for probing chemical and dimensional dynamics with appropriate modeling.
Progress Toward Fast Decay Energy Spectroscopy for Actinide Analysis
Decay energy spectroscopy (DES) is an increasingly popular technique for measuring isotopic composition of actinide samples for nuclear safeguards applications. Current approaches for actinide DES utilize milligram-scale external gold absorbers (> 0.1 nJ/K) that are integrated with actinide samples through mechanical kneading and are thermally connected to microcalorimeters using indium or gold wire bonds. This leads to relatively slow sensor rise time and, consequently, limits counting speed to a few counts per second. We are developing faster metallic magnetic calorimeter-based DES by integrating actinide samples with magnetic sensor materials. This reduces signal rise time and enables high counting speed while maintaining the ability to knead the radioactive source with the absorber. We have measured signal rise time of 0.7 μs with a 1.5 mg external gold absorber using this approach. Here, we also demonstrated online DES operation using an Ortec DSPEC 50, a commercially available data acquisition system developed for semiconductor detectors.
Robotic sample changers for macromolecular X-ray crystallography and biological small-angle X-ray scattering at the National Synchrotron Light Source II
In this work, we present two robotic sample changers integrated into the experimental stations for the macromolecular crystallography (MX) beamlines AMX and FMX, and the biological small-angle scattering (bioSAXS) beamline LiX. They enable fully automated unattended data collection and remote access to the beamlines. The system designs incorporate high-throughput, versatility, high-capacity, resource sharing and robustness. All systems are centered around a six-axis industrial robotic arm coupled with a force torque sensor and in-house end effectors (grippers). They have the same software architecture and the facility standard EPICS-based BEAST alarm system. The MX system is compatible with SPINE bases and Unipucks. It comprises a liquid nitrogen dewar holding 384 samples (24 Unipucks) and a stay-cold gripper, and utilizes machine vision software to track the sample during operations and to calculate the final mount position on the goniometer. The bioSAXS system has an in-house engineered sample storage unit that can hold up to 360 samples (20 sample holders) which keeps samples at a user-set temperature (277 K to 300 K). The MX systems were deployed in early 2017 and the bioSAXS system in early 2019.
Underground Test Area (UGTA) Sampling Plan for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada National Security Site, Nevada, Revision 2
The purpose of this groundwater sampling plan (referred to herein as “the Plan”) is to describe the approach for collecting and analyzing groundwater samples to meet the objectives of the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program’s Underground Test Area (UGTA) Activity. The Plan is focused on the Central and Western Pahute Mesa corrective action units (CAUs 101 and 102), which are currently in the Corrective Action Decision Document (CADD)/Corrective Action Plan (CAP) stage of the Federal Facility Agreement and Consent Order (FFACO) UGTA Strategy. The remaining UGTA CAUs are in the final stage of the UGTA strategy (Closure Report [CR] stage), and monitoring requirements for these CAUs are described in the Federal Facility Agreement and Consent Order Nevada National Security Site Use Restriction Management Plan (DOE/EMNV, 2024a). The Plan supersedes the Nevada National Security Site Integrated Groundwater Sampling Plan and its ensuing Record of Technical Change (ROTC) (DOE/EMNV, 2019b).
Integrated modeling for assessing climate change impacts on water resources and hydropower potential in the Himalayas
Regional hydroclimatic variability and change can affect water resources and hydropower generation. It is essential to assess hydropower potential under current and future climatic conditions to inform the design and operation of hydropower infrastructures. Here, we employ an integrated modeling framework to assess the impact of projected hydroclimatic conditions on water resource systems and hydropower generation. The integrated framework samples climate model outputs under different scenarios to force a hydrologic model and produces streamflow projections. The projected streamflows are inputs for the future hydropower potential assessment. We implement the framework in the central Himalayan river basin. Our results demonstrate substantial spatiotemporal variability in different water balance components (precipitation, evapotranspiration, and water yield) under current and future climatic conditions. For the Himalayan Tila river basin, the annual average energy production is expected to increase under future hydroclimatic conditions (up to 39% in Tila-2 hydropower project, suggested by ensemble mean). Furthermore, this increase in energy is driven mainly by the increased streamflow projections, particularly during the dry season and in the late century. Our results highlight the impacts of hydroclimatic variability in hydropower productions and are of practical use to provide decision-relevant information for designing and operating hydropower infrastructures. The integrated modeling framework presented here is region-specific; however, the approach is reproducible, and the overall insights are generalizable across the Himalayan region.
Intensity-Value Corrections for Integrating Sphere Measurements of Solid Samples Measured Behind Glass
Accurate and calibrated directional-hemispherical reflectance spectra of solids are important for both in situ and remote sensing. Many solids are in the form of powders or granules and to measure their diffuse reflectance spectra in the laboratory, it is often necessary to place the samples behind a transparent medium such as glass for the ultraviolet (UV), visible, or near-infrared spectral regions. Using both experimental methods and a simple optical model, we demonstrate that glass (fused quartz in our case) leads to artifacts in the reflectance values. We report our observations that the measured reflectance values, for both hemispherical and diffuse reflectance, are distorted by the additional reflections arising at the air–quartz and sample–quartz interfaces. The values are dependent on the sample reflectance and are offset in intensity in the hemispherical case, leading to measured values up to ~6% too high for a 2% reflectance surface, ~3.8% too high for 10% reflecting surfaces, approximately correct for 40–60% diffuse-reflecting surfaces, and ~1.5% too low for 99% reflecting Spectralon® surfaces. For the case of diffuse-only reflectance, the measured values are uniformly too low due to the polished glass, with differences of nearly 6% for a 99% reflecting matte surface. The deviations arise from the added reflections from the quartz surfaces, as verified by both theory and experiment, and depend on sphere design. Finally, empirical correction factors were implemented into post-processing software to redress the artifact for hemispherical and diffuse reflectance data across the 300–2300 nm range.
Rapid onset of mafic magmatism facilitated by volcanic edifice collapse
Volcanic edifice collapses generate some of Earth's largest landslides. How such unloading affects the magma storage systems is important for both hazard assessment and for determining long-term controls on volcano growth and decay. Here we present a detailed stratigraphic and petrological analyses of volcanic landslide and eruption deposits offshore Montserrat, in a subduction zone setting, sampled during Integrated Ocean Drilling Program Expedition 340. A large (6-10km 3 ) collapse of the Soufrière Hills Volcano at ~130 ka was followed by explosive basaltic volcanism and the formation of a new basaltic volcanic center, the South Soufrière Hills, estimated to have initiated <100 years after collapse. This basaltic volcanism was a sharp departure from the andesitic volcanism that characterized Soufrière Hills' activity before the collapse. Mineral-melt thermobarometry demonstrates that the basaltic magma's transit through the crust was rapid and from midcrustal depths. We suggest that this rapid ascent was promoted by unloading following collapse.
Dilution-Free Analysis from Picoliter Droplets by Nano-Electrospray Ionization Mass Spectrometry
The expanding role of microfluidics for chemical and biochemical analysis is due to factors including the favorable scaling of separation performance with reduced channel dimensions,[1] flexibility afforded by computer-aided device design, and the ability to integrate multiple sample handling and analysis steps into a single platform.[2] Such devices enable smaller liquid volumes and sample sizes to be handled than can be achieved on the benchtop, where sub-microliter volumes are difficult to work with and where sample losses to the surfaces of multiple reaction vessels become prohibitive. A particularly attractive microfluidic platform for sample-limited analyses employs aqueous droplets or plugs encapsulated by an immiscible oil.[3,4] Each droplet serves as a discrete compartment or reaction chamber enabling, e.g., high throughput screening[5,6] and kinetic studies[7-9] of femto- to nanoliter samples, as well as the encapsulation[10-12] and lysis[10] of individual cells with limited dilution of the cellular contents
Materials Learning Algorithms (MALA): Scalable machine learning for electronic structure calculations in large-scale atomistic simulations
We present the Materials Learning Algorithms (MALA) package, a scalable machine learning framework designed to accelerate density functional theory (DFT) calculations suitable for large-scale atomistic simulations. Using local descriptors of the atomic environment, MALA models efficiently predict key electronic observables, including local density of states, electronic density, density of states, and total energy. The package integrates data sampling, model training and scalable inference into a unified library, while ensuring compatibility with standard DFT and molecular dynamics codes. We demonstrate MALA's capabilities with examples including boron clusters, aluminum across its solid-liquid phase boundary, and predicting the electronic structure of a stacking fault in a large beryllium slab. Scaling analyses reveal MALA's computational efficiency and identify bottlenecks for future optimization. With its ability to model electronic structures at scales far beyond standard DFT, MALA is well suited for modeling complex material systems, making it a versatile tool for advanced materials research.
Girth and groomed radius of jets recoiling against isolated photons in lead-lead and proton-proton collisions at $\sqrt{s_{NN}} = 5.02$ TeV
This Letter presents the first measurements of the groomed jet radius R g and the jet girth g in events with an isolated photon recoiling against a jet in lead-lead (PbPb) and proton-proton (pp) collisions at the LHC at a nucleon-nucleon center-of-mass energy of 5.02 TeV. The observables R g and g provide a quantitative measure of how narrow or broad a jet is. The analysis uses PbPb and pp data samples with integrated luminosities of 1.7 nb -1 and 301 pb -1 , respectively, collected with the CMS experiment in 2018 and 2017. Events are required to have a photon with transverse momentum $p^{γ}_{T} > 100$ GeV and at least one jet back-to-back in azimuth with respect to the photon and with transverse momentum $p^{jet}_{T}$ such that $p^{jet}_{T}/p^{γ}_{T} > 0.4$ . The measured R g and g distributions are unfolded to the particle level, which facilitates the comparison between the PbPb and pp results and with theoretical predictions. It is found that jets with $p^{jet}_{T}/p^{γ}_{T} > 0.8$ , i.e., those that closely balance the photon $p^{γ}_{T}$ , are narrower in PbPb than in pp collisions. Relaxing the selection to include jets with $p^{jet}_{T}/p^{γ}_{T} > 0.4$ reduces the narrowing of the angular structure of jets in PbPb relative to the pp reference. This shows that selection bias effects associated with jet energy loss play an important role in the interpretation of jet substructure measurements.
Fossil and biogenic CO{sub 2} from waste incineration based on a yearlong radiocarbon study
Highlights: Black-Right-Pointing-Pointer Yearlong radiocarbon study on the share of biogenic CO{sub 2} from waste incineration. Black-Right-Pointing-Pointer Direct approach combining temporal integrating gas sampling and {sup 14}CO{sub 2} analysis by AMS. Black-Right-Pointing-Pointer Significant differences between incinerators with 43% and 54%Fos C. Black-Right-Pointing-Pointer No annual cycle of fossil CO{sub 2} for all, except one, of the included incinerators. - Abstract: We describe the first long-term implementation of the radiocarbon ({sup 14}C) method to study the share of biogenic (%Bio C) and fossil (%Fos C) carbon in combustion CO{sub 2}. At five Swiss incinerators, a total of 24 three-week measurement campaigns were performed over 1 year. Temporally averaged bag samples were analyzed for {sup 14}CO{sub 2} by accelerator mass spectrometry. Significant differences between the plants in the share of fossil CO{sub 2} were observed, with annual mean values from 43.4 {+-} 3.9% to 54.5 {+-} 3.1%. Variations can be explained by the waste composition of the respective plant. Based on our dataset, an average value of 48 {+-} 4%Fos C was determined for waste incineration in Switzerland. No clear annual trend in %Fos C was observed for four of the monitored incinerators, while one incinerator showed considerable variations, which are likely due to the separation and temporary storage of bulky goods.
Direct Surface and Droplet Microsampling for Electrospray Ionization Mass Spectrometry Analysis with an Integrated Dual-Probe Microfluidic Chip
Ambient mass spectrometry (MS) has revolutionized the way of MS analysis and broadened its application in various fields. This paper describes the use of microfluidic techniques to simplify the setup and improve the functions of ambient MS by integrating the sampling probe, electrospray emitter probe, and online mixer on a single glass microchip. Two types of sampling probes, including a parallel-channel probe and a U-shaped channel probe, were designed for dryspot and liquid-phase droplet samples, respectively. We demonstrated that the microfabrication techniques not only enhanced the capability of ambient MS methods in analysis of dry-spot samples on various surfaces, but also enabled new applications in the analysis of nanoliter-scale chemical reactions in an array of droplets. The versatility of the microchip-based ambient MS method was demonstrated in multiple different applications including evaluation of residual pesticide on fruit surfaces, sensitive analysis of low-ionizable analytes using postsampling derivatization, and high-throughput screening of Ugi-type multicomponent reactions.
Automated Development of Molten Salt Machine Learning Potentials: Application to LiCl
The in silico modeling of molten salts is critical for emerging "carbon-free" energy applications but is inhibited by the cost of quantum mechanically treating the high polarizabilities of molten salts. Here, we integrate configurational sampling using classical force fields with active learning to automate and accelerate the generation of Gaussian approximation potentials (GAP) for molten salts. This methodology reduces the number of expensive ab initio evaluations required for training set generation to O(100), enabling the facile parametrization of a molten LiCl GAP model that exhibits a 19 000-fold speedup relative to AIMD. The developed molten LiCl GAP model is applied to sample extended spatiotemporal scales, permitting new physical insights into molten LiCl's coordination structure as well as experimentally validated predictions of structures, densities, self-diffusion constants, and ionic conductivities. The developed methodology significantly lowers the barrier to the in silico understanding and design of molten salts across the periodic table.
Parallel measurement of transcriptomes and proteomes from same single cells using nanodroplet splitting
Single-cell multiomics provides comprehensive insights into gene regulatory networks, cellular diversity, and temporal dynamics. Here, we introduce nanoSPLITS (nanodroplet SPlitting for Linked-multimodal Investigations of Trace Samples), an integrated platform that enables global profiling of the transcriptome and proteome from same single cells via RNA sequencing and mass spectrometry-based proteomics, respectively. Benchmarking of nanoSPLITS demonstrates high measurement precision with deep proteomic and transcriptomic profiling of single-cells. We apply nanoSPLITS to cyclin-dependent kinase 1 inhibited cells and found phospho-signaling events could be quantified alongside global protein and mRNA measurements, providing insights into cell cycle regulation. We extend nanoSPLITS to primary cells isolated from human pancreatic islets, introducing an efficient approach for facile identification of unknown cell types and their protein markers by mapping transcriptomic data to existing large-scale single-cell RNA sequencing reference databases. Accordingly, we establish nanoSPLITS as a multiomic technology incorporating global proteomics and anticipate the approach will be critical to furthering our understanding of biological systems.
Robotic integration for end-stations at scientific user facilities
Schematic representation of the robotic beamline scientist system. The architecture integrates a sample database, ROS2 Action service, and Bluesky tooling to facilitate adaptive robotic sample management.