Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rotating target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Near-Threshold Rovibrational Excitation of HF by Electron Impact

The pronounced threshold peaks found in cross sections for electron-impact excitation of the vibrational levels of HF have been studied using an R-matrix method, in which electron exchange, correlation effects and polarization are included. Vibration is modelled inside the R-matrix sphere using the energy-modified adiabatic phase matrix method (EMAP). Rotation of the target molecule is treated outside the R-matrix sphere, using the frame transformation method. The external rovibronic close-coupling equations are solved by analytic methods. Analysis of the multichannel threshold structures indicates that the peaks found for rovibrational excitation of nu = 1 can be interpreted as virtual states while those for nu = 2 correspond to nuclear-excited Feshbach resonances. These two different results correspond simply to a change of sign of a small parameter that is determined by the threshold analysis. Whereas the overall shapes of the excitation peaks agree with earlier theoretical results, we have found detailed rotational fine structures for scattering energies on the order of the rotational constant above and below the opening of the vibrational channels. The partial and total cross sections for rovibrational state-to-state transitions in the energy region of the peaks are analysed. Characteristic cusp structures and excitation peaks are found at the rovibrational thresholds for transitions with small angular momentum transfer (Delta)j =0, 1 and 2. Differential cross sections are similar to recent measurements. These experimental data do not show the relatively sharp rise at the vibrational thresholds indicated by theory. Theory and experiment are in good agreement for the shape and magnitude of the angular dependence of cross sections for rovibrational state-to-state transitions, especially at larger energies.

Thummel, Helmar T.↗

Sensorimotor aspects of high-speed artificial gravity: III. Sensorimotor adaptation

As a countermeasure to the debilitating physiological effects of weightlessness, astronauts could live continuously in an artificial gravity environment created by slow rotation of an entire spacecraft or be exposed to brief daily "doses" in a short radius centrifuge housed within a non-rotating spacecraft. A potential drawback to both approaches is that head movements made during rotation may be disorienting and nauseogenic. These side effects are more severe at higher rotation rates, especially upon first exposure. Head movements during rotation generate aberrant vestibular stimulation and Coriolis force perturbations of the head-neck motor system. This article reviews our progress toward distinguishing vestibular and motor factors in side effects of rotation, and presents new data concerning the rates of rotation up to which adaptation is possible. We have studied subjects pointing to targets during constant velocity rotation, because these movements generate Coriolis motor perturbations of the arm but do not involve unusual vestibular stimulation. Initially, reaching paths and endpoints are deviated in the direction of the transient lateral Coriolis forces generated. With practice, subjects soon move in straighter paths and land on target once more. If sight of the arm is permitted, adaptation is more rapid than in darkness. Initial arm movement trajectory and endpoint deviations are proportional to Coriolis force magnitude over a range of rotation speeds from 5 to 20 rpm, and there is rapid, complete motor adaptation at all speeds. These new results indicate that motor adaptation to high rotation rates is possible. Coriolis force perturbations of head movements also occur in a rotating environment but adaptation gradually develops over the course of many head movements.

Non-NASA Center↗

129 Xe NMR Relaxation-Based Macromolecular Sensing

A 129 Xe NMR relaxation-based sensing approach is reported on that exploits changes in the bulk xenon relaxation rate induced by slowed tumbling of a cryptophane-based sensor upon target binding. The amplification afforded by detection of the bulk dissolved xenon allows sensitive detection of targets. The sensor comprises a xenon-binding cryptophane cage, a target interaction element, and a metal chelating agent. Xenon associated with the target-bound cryptophane cage is rapidly relaxed and then detected after exchange with the bulk. Here we show that large macromolecular targets increase the rotational correlation time of xenon, increasing its relaxation rate. Upon binding of a biotin-containing sensor to avidin at 1.5 μM concentration, the free xenon T 2 is reduced by a factor of 4.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact system for ultrafast synchrotron experiments

The impact system for ultrafast synchrotron experiments, or IMPULSE, is a 12.6-mm bore light-gas gun (<1 km/s projectile velocity) designed specifically for performing dynamic compression experiments using the advanced imaging and X-ray diffraction methods available at synchrotron sources. The gun system, capable of reaching projectile velocities up to 1 km/s, was designed to be portable for quick insertion/removal in the experimental hutch at Sector 32 ID-B of the Advanced Photon Source (Argonne, IL) while allowing the target chamber to rotate for sample alignment with the beam. A key challenge in using the gun system to acquire dynamic data on the nanosecond time scale was synchronization (or bracketing) of the impact event with the incident X-ray pulses (80 ps width). A description of the basic gun system used in previous work is provided along with details of an improved launch initiation system designed to significantly reduce the total system time from launch initiation to impact. Experiments were performed to directly measure the gun system time and to determine the gun performance curve for projectile velocities ranging from 0.3 to 0.9 km/s. All results show an average system time of 21.6 {+-} 4.5 ms, making it possible to better synchronize the gun system and detectors to the X-ray beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion temperature gradient turbulence modification in quasi-axisymmetry

The large flexibility of the proposed QUASAR facility is leveraged in order to explore the effect of magnetic shear on adiabatic Ion Temperature Gradient (ITG) turbulence. The QUASAR facility is a reimagining of the National Compact Stellarator Experiment utilizing and expanding upon the already constructed coil set. Recent work using fixed boundary optimization of the LI383 equilibrium (upon which QUASAR is based) has suggested possible improvements to ITG turbulence. In this work, a different approach is taken, wherein a series of self-consistent free boundary VMEC equilibria are developed for QUASAR. These equilibria assume temperature and density profiles consistent with 2% beta and ohmic current drive. In each configuration, the toroidal field coils are energized to different values and the STELLOPT code is used to vary the modular coil current and net toroidal current. The edge value of rotational transform is targeted in the optimization, producing a magnetic shear scan. All these configurations share similar neoclassical transport levels, while nonlinear GENE flux tube simulations show up to a factor of four change in adiabatic ITG turbulence at various radii. Comparisons of proxy functions and linear flux tube runs are also made. This work highlights the capability of the QUASAR experiment as a tool to explore transport in 3D magnetic fields and the possibility of the further improvements to stellarators through optimization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automatic tracking of implanted fiducial markers in cone beam CT projection images

Purpose: This paper describes a novel method for simultaneous intrafraction tracking of multiple fiducial markers. Although the proposed method is generic and can be adopted for a number of applications including fluoroscopy based patient position monitoring and gated radiotherapy, the tracking results presented in this paper are specific to tracking fiducial markers in a sequence of cone beam CT projection images. Methods: The proposed method is accurate and robust thanks to utilizing the mean shift and random sampling principles, respectively. The performance of the proposed method was evaluated with qualitative and quantitative methods, using data from two pancreatic and one prostate cancer patients and a moving phantom. The ground truth, for quantitative evaluation, was calculated based on manual tracking preformed by three observers. Results: The average dispersion of marker position error calculated from the tracking results for pancreas data (six markers tracked over 640 frames, 3840 marker identifications) was 0.25 mm (at iscoenter), compared with an average dispersion for the manual ground truth estimated at 0.22 mm. For prostate data (three markers tracked over 366 frames, 1098 marker identifications), the average error was 0.34 mm. The estimated tracking error in the pancreas data was < 1 mm (2 pixels) in 97.6% of cases where nearby image clutter was detected and in 100.0% of cases with no nearby image clutter. Conclusions: The proposed method has accuracy comparable to that of manual tracking and, in combination with the proposed batch postprocessing, superior robustness. Marker tracking in cone beam CT (CBCT) projections is useful for a variety of purposes, such as providing data for assessment of intrafraction motion, target tracking during rotational treatment delivery, motion correction of CBCT, and phase sorting for 4D CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic tracking of arbitrarily shaped implanted markers in kilovoltage projection images: A feasibility study

Purpose: Certain types of commonly used fiducial markers take on irregular shapes upon implantation in soft tissue. This poses a challenge for methods that assume a predefined shape of markers when automatically tracking such markers in kilovoltage (kV) radiographs. The authors have developed a method of automatically tracking regularly and irregularly shaped markers using kV projection images and assessed its potential for detecting intrafractional target motion during rotational treatment. Methods: Template-based matching used a normalized cross-correlation with simplex minimization. Templates were created from computed tomography (CT) images for phantom studies and from end-expiration breath-hold planning CT for patient studies. The kV images were processed using a Sobel filter to enhance marker visibility. To correct for changes in intermarker relative positions between simulation and treatment that can introduce errors in automatic matching, marker offsets in three dimensions were manually determined from an approximately orthogonal pair of kV images. Two studies in anthropomorphic phantom were carried out, one using a gold cylindrical marker representing regular shape, another using a Visicoil marker representing irregular shape. Automatic matching of templates to cone beam CT (CBCT) projection images was performed to known marker positions in phantom. In patient data, automatic matching was compared to manual matching as an approximate ground truth. Positional discrepancy between automatic and manual matching of less than 2 mm was assumed as the criterion for successful tracking. Tracking success rates were examined in kV projection images from 22 CBCT scans of four pancreas, six gastroesophageal junction, and one lung cancer patients. Each patient had at least one irregularly shaped radiopaque marker implanted in or near the tumor. In addition, automatic tracking was tested in intrafraction kV images of three lung cancer patients with irregularly shaped markers during 11 volumetric modulated arc treatments. Purpose-built software developed at our institution was used to create marker templates and track the markers embedded in kV images. Results: Phantom studies showed mean ± standard deviation measurement uncertainty of automatic registration to be 0.14 ± 0.07 mm and 0.17 ± 0.08 mm for Visicoil and gold cylindrical markers, respectively. The mean success rate of automatic tracking with CBCT projections (11 frames per second, fps) of pancreas, gastroesophageal junction, and lung cancer patients was 100%, 99.1% (range 98%–100%), and 100%, respectively. With intrafraction images (approx. 0.2 fps) of lung cancer patients, the success rate was 98.2% (range 97%–100%), and 94.3% (range 93%–97%) using templates from 1.25 mm and 2.5 mm slice spacing CT scans, respectively. Correction of intermarker relative position was found to improve the success rate in two out of eight patients analyzed. Conclusions: The proposed method can track arbitrary marker shapes in kV images using templates generated from a breath-hold CT acquired at simulation. The studies indicate its feasibility for tracking tumor motion during rotational treatment. Investigation of the causes of misregistration suggests that its rate of incidence can be reduced with higher frequency of image acquisition, templates made from smaller CT slice spacing, and correction of changes in intermarker relative positions when they occur.

60 APPLIED LIFE SCIENCES↗

TU-CD-BRA-01: A Novel 3D Registration Method for Multiparametric Radiological Images

Purpose: Multiparametric and multimodality radiological imaging methods, such as, magnetic resonance imaging(MRI), computed tomography(CT), and positron emission tomography(PET), provide multiple types of tissue contrast and anatomical information for clinical diagnosis. However, these radiological modalities are acquired using very different technical parameters, e.g.,field of view(FOV), matrix size, and scan planes, which, can lead to challenges in registering the different data sets. Therefore, we developed a hybrid registration method based on 3D wavelet transformation and 3D interpolations that performs 3D resampling and rotation of the target radiological images without loss of information Methods: T1-weighted, T2-weighted, diffusion-weighted-imaging(DWI), dynamic-contrast-enhanced(DCE) MRI and PET/CT were used in the registration algorithm from breast and prostate data at 3T MRI and multimodality(PET/CT) cases. The hybrid registration scheme consists of several steps to reslice and match each modality using a combination of 3D wavelets, interpolations, and affine registration steps. First, orthogonal reslicing is performed to equalize FOV, matrix sizes and the number of slices using wavelet transformation. Second, angular resampling of the target data is performed to match the reference data. Finally, using optimized angles from resampling, 3D registration is performed using similarity transformation(scaling and translation) between the reference and resliced target volume is performed. After registration, the mean-square-error(MSE) and Dice Similarity(DS) between the reference and registered target volumes were calculated. Results: The 3D registration method registered synthetic and clinical data with significant improvement(p<0.05) of overlap between anatomical structures. After transforming and deforming the synthetic data, the MSE and Dice similarity were 0.12 and 0.99. The average improvement of the MSE in breast was 62%(0.27 to 0.10) and prostate was 63%(0.13 to 0.04;p<0.05). The Dice similarity was in breast 8%(0.91 to 0.99) and for prostate was 89%(0.01 to 0.90;p<0.05) Conclusion: Our 3D wavelet hybrid registration approach registered diverse breast and prostate data of different radiological images(MR/PET/CT) with a high accuracy.

60 APPLIED LIFE SCIENCES↗

Interactions of amorphous Ta(x)Cu(1-x) (x = 0.93 and 0.80) alloy films with Au overlayers and GaAs substrates

Amorphous Ta(93)Cu(7) and Ta(80)Cu(20) alloy films are prepared by cosputtering of pure Ta and pure Cu targets with a rotating sample holder table. To investigate the possible application of these materials as diffusion barriers for the Au-GaAs system, vacuum annealings are made in the temperature range from 200 to 800 C. Resistivity change, X-ray diffraction, and Auger electron spectroscopy measurements are performed to find the chemical and metallurgical stabilities of these materials in this system. The reaction temperature for Ta(x)Cu(1-x) in contact with GaAs lies between 500 and 700 C. For Au in contact with Ta(x)Cu(1-x) the reaction occurs at about 600 C. Amorphous Ta(93)Cu(7) shows different interdiffusion characteristics with surrounding elements than does Ta(80)Cu(20).

Oh, Jae E.↗

Stray signal requirements for compact range reflectors based on RCS measurement errors

The authors present a performance criterion for compact range reflectors such that their edge diffracted stray signal levels meet a reasonable radar cross section (RCS) measurement error requirement. It is shown by example that one of the significant error sources is the diffracted fields emanating from the edges or junctions of the reflector. This measurement error is demonstrated by placing a diagonal square flat plate in the target zone and rotating it to appropriate angles. These angles are determined by bisecting the plane wave and stray signal directions. This results in a peak bistatic measurement of the edge diffracted stray signal. It is proposed that the diagonal flat plate be used to evaluate new reflector designs as well as existing systems. A reasonable stray signal performance level has been developed so that new reflector systems can be characterized in terms of an RCS measurement error requirement.

Lee, Teh-Hong↗

Angular momentum transfer in low velocity oblique impacts - Implications for asteroids

An experimental study has been conducted for the low-velocity oblique impact efficiency of angular momentum transfer, which is defined as that fraction of incident angular momentum that is transferred to the rotation of a target. The results obtained suggest that more energetic impacts are able to transfer angular momentum more efficiently. In the cases of ricochetted projectiles, the fraction of angular momentum carried off by the ejecta was noted to be less than 30 percent. It is suggested that, if asteroid spin rates are due to mutual noncatastrophic collisions and the taxonomic classes are indicative of bulk properties, the differences between corresponding spin rates will be smaller than expected from a consideration of relative strength and density alone.

Yanagisawa, Masahisa↗

Premixed Gas Combustion: An Excitable System

Rotating spiral and target patterns have been observed experimentally on freely-propagating premixed gas flames in large diameter tubes at normal gravity (1-g). These modes of propagation occur in near-limit mixtures which have a Lewis number (Le, defined as the ratio of the thermal diffusivity of the cold mixture to the mass diffusivity of the scarce component into the mixture) sufficiently greater than one. However, at 1-g, buoyant flows strongly distort the flame curvature, hydrodynamics (thus stretch) and convective transport of species and heat. In turn, these alter the critical Le required for onset of instability. To isolate and better understand the mechanisms which drive the observed patterns and their dynamics, 1-g and microgravity (micro-g) experiments are being conducted to determine: (1) the structure and dynamics of the patterns, (2) a map of the critical Le and heat loss for their occurrence, (3) the relative significance of the chemical kinetics, and (4) the effect of curvature (local wave and global flame front) on wave propagation. With this in hand, we will be better prepared to discuss an additional mode, a state of 'chemical turbulence,' which seems to be the ultimate fate of many of these near-limit flames prior to extinction.

Pearlman, Howard↗

Droplet distributions from melt displacement and ejection mechanism during Al ns-laser ablation and deposition experiments: Influence of laser spot position

Experimental observations of the angular distribution of droplets during laser ablation and deposition of Al thin films are presented and discussed. The experimental results, obtained by simply moving the laser spot position with respect to the rotation axis of the target, allow clarification of the unexpected symmetric double peaked angular droplet distribution on the films. These results provide direct evidence that a laser fluence threshold exists, beyond which droplets are generated from a melt displacement and ejection mechanism rather than from a phase explosion. The main directions of particulate ejection are related to the particular geometry of the laser generated tracks, whose profiles depend on the relative position of the incident beam with respect to the rotation axis of the target.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dosimetric Changes Resulting From Patient Rotational Setup Errors in Proton Therapy Prostate Plans

Purpose: To evaluate the dose changes to the target and critical structures from rotational setup errors in prostate cancer patients treated with proton therapy. Methods and Materials: A total of 70 plans were analyzed for 10 patients treated with parallel-opposed proton beams to a dose of 7,600 {sup 60}Co-cGy-equivalent (CcGE) in 200 CcGE fractions to the clinical target volume (i.e., prostate and proximal seminal vesicles). Rotational setup errors of +3{sup o}, -3 deg., +5 deg., and -5 deg. (to simulate pelvic tilt) were generated by adjusting the gantry. Horizontal couch shifts of +3 deg. and -3 deg. (to simulate longitudinal setup variability) were also generated. Verification plans were recomputed, keeping the same treatment parameters as the control. Results: All changes shown are for 38 fractions. The mean clinical target volume dose was 7,780 CcGE. The mean change in the clinical target volume dose in the worse case scenario for all shifts was 2 CcGE (absolute range in worst case scenario, 7,729-7,848 CcGE). The mean changes in the critical organ dose in the worst case scenario was 6 CcGE (bladder), 18 CcGE (rectum), 36 CcGE (anterior rectal wall), and 141 CcGE (femoral heads) for all plans. In general, the percentage of change in the worse case scenario for all shifts to the critical structures was <5%. Deviations in the absolute percentage of volume of organ receiving 45 and 70 Gy for the bladder and rectum were <2% for all plans. Conclusion: Patient rotational movements of 3 deg. and 5 deg. and horizontal couch shifts of 3 deg. in prostate proton planning did not confer clinically significant dose changes to the target volumes or critical structures00.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deposition of ultrathick heavy-metal alloys on rotating substrates by high-power impulse magnetron sputtering: Target erosion effects

Sputter deposition of ultrathick (≈20μm) Au–Ta alloy coatings on sphero-cylindrical substrates is key for the fabrication of hohlraums for magnetically assisted inertial confinement fusion. In this work, we study the deposition of AuTa 4 alloy coatings onto rotating substrates. We use high-power impulse magnetron sputtering (HiPIMS) in a constant peak target voltage mode. Results show that the target erosion state has a strong impact on the dominant crystallographic phase, microstructure, surface morphology, and electrical resistivity of AuTa 4 films. This is due to effects of changes in the confining magnetic field with target erosion on the HiPIMS discharge characteristics and the sputter source output. We quantify these effects via plasma diagnostics and discuss the optimization of HiPIMS deposition of ultrathick films for cases when target erosion effects dominate film properties.

36 MATERIALS SCIENCE↗

Circular and linear polarization inverse SAR imaging of simple deterministic targets and statistically known randomly rough surfaces using constant and varying illumination

In order to study mechanisms of scattering and their relative contributions to synthetic aperture radar (SAR) and inverse SAR images, a special measurement facility has been constructed. It can be used to generate images in which the target is illuminated from a constant direction as the receiver is rotated in azimuth, and the target is illuminated from various directions as the receiver is rotated in azimuth. The imaging system performance is discussed, and images obtained using both approaches are compared, for a variety of simple targets and statistically known randomly rough surfaces.

Bredow, J. W.↗

Simultaneous stabilization and control of the n = 1 and n = 2 resistive wall mode

Abstract DIII-D experiments demonstrate simultaneous stability measurements and control of resistive wall modes (RWMs) with toroidal mode numbers n = 1 and n = 2. RWMs with n > 1 are sometimes observed on DIII-D following the successful feedback stabilization of the n = 1 mode, motivating the development of multi- n control. A new model-based multi-mode feedback algorithm based on the VALEN physics code has been implemented on the DIII-D tokamak using a real-time GPU installed directly into the DIII-D plasma control system. In addition to stabilizing RWMs, the feedback seeks to control the stable plasma error field response, enabling compensation of the typically unaddressed DIII-D n = 2 error field component. Experiments recently demonstrated this algorithm’s ability to simultaneously control n = 1 and n = 2 perturbed fields for the first time in a tokamak, using reactor relevant external coils. Control was maintained for hundreds of wall-times above the n = 1 no-wall pressure limit and approaching the n = 1 and n = 2 ideal-wall limits. Furthermore, a rotating non-zero target was set for the feedback, allowing stability to be assessed by monitoring the rotating plasma response (PR) while maintaining control. This novel technique can be viewed as a closed-loop extension of active MHD spectroscopy, which has been used to validate stability models through comparisons of the PR to applied, open-loop perturbations. The closed-loop response measurements are consistent with open-loop MHD spectroscopy data over a wide range of β N approaching the n = 1 ideal-wall limit. These PR measurements were then fit to produce both VALEN and single-mode stability models. These models allowed for important plasma stability information to be determined and have been shown to agree with experimentally observed RWM growth rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗