Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “rf source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Matrix of small-radius radio-frequency discharges as a volume-production based source of negative hydrogen ions

Based on experience from a work - both theoretical and experimental one - on negative hydrogen ion beam sources studied regarding fusion applications, a novel design of a rf source with volume production of the ions is proposed. The suggestion is for a source constructed as a matrix of small-radius tandem discharges (with magnetic filters largely extended over the discharge length), inductively driven (by a single coil, for the whole matrix) and with a single aperture extraction from each of them.

43 PARTICLE ACCELERATORS↗

RF-driven ion source with a back-streaming electron dump

A novel ion source is described having an improved lifetime. The ion source, in one embodiment, is a proton source, including an external RF antenna mounted to an RF window. To prevent backstreaming electrons formed in the beam column from striking the RF window, a back streaming electron dump is provided, which in one embodiment is formed of a cylindrical tube, open at one end to the ion source chamber and capped at its other end by a metal plug. The plug, maintained at the same electrical potential as the source, captures these backstreaming electrons, and thus prevents localized heating of the window, which due to said heating, might otherwise cause window damage.

47 OTHER INSTRUMENTATION↗

Radio-Frequency Resonances and Damping in Metallic Magnetic Calorimeter Sensors

Metallic magnetic calorimeters (MMCs) are particle detectors that combine ultra-high energy resolution with a predictable and smooth response based on the physics of paramagnetism. For best energy resolution, MMCs are read out with dc SQUID preamplifiers. Since the ac Josephson effect also makes dc SQUIDs broadband RF sources in the 1–100 GHz range, the SQUID can potentially excite RF modes of the MMC sensor, with negative consequences. Further, the importance of this possibility is magnified in direct-coupled MMCs, where the MMC sensor is part of the SQUID loop to maximize performance. For these reasons, the RF behavior of MMC sensors must be investigated. In this report, we present the results of exploratory RF simulations of MMC sensor modes and damping, and we assess three approaches to damp the parallel-meander direct-coupled MMC without excessive noise increase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design Features and Initial RF Performance of a Gradient Hardened 17 GHz TW Linac Structure

To avoid surface erosion damage and to assist in studying RF breakdown thresholds in 17 GHz TW linac structures, a gradient hardened structure has been fabricated with high temperature brazed and machined stainless steel surfaces located in the peak E-field region of the beam apertures and the peak H-field regions of the input coupler cavity. The microwave design parameters and physical dimensions of this 22 cavity, 120 degree phase advance structure were chosen to allow the high gradient performance to be compared against a similar design all-copper structure that has been tested in a dual ring, power recirculating amplifier system. The final design parameters of the gradient hardened structure are discussed; the influence of stainless steel RF losses on the power buildup of the resonant ring and on the structure gradient distribution are described; waveforms are shown of the unique ability of the power amplifier to rapidly quench RF breakdown discharges in the linac structure by automatically sensing and redirecting the RF source power to a matched load; and preliminary test results during high power RF processing of the gradient hardened linac structure are presented.

43 PARTICLE ACCELERATORS↗

Modeling of the rf discharge initiation in a negative ion source

The maintenance free rf ion source is expected to be one of the most promising candidates for the negative ion sources of plasma heating for future fusion reactors. As an alternative to the arc-discharge sources, the rf negative ion sources have been developed for H{sup -} production. In order to make clear the condition for the discharge initiation of the rf source, we are developing a numerical model using the finite difference time domain Monte Carlo method to analyze the electron energy distribution function in rf field. The numerical result shows that the discharge is not successfully initiated due to the wall loss unless the wall potential is considered. More self-consistent model including ion dynamics to evaluate the wall potential and the electron loss at the wall will be needed in the future.

43 PARTICLE ACCELERATORS↗

Multi-Cavity Proton Cyclotron Accelerator: An Electron Counterpart

A multi-cavity multi-frequency proton cyclotron accelerator has been proposed. It would utilize cyclotron resonance in each of eight cavities of uniformly diminishing frequency in a uniform magnetic field to comprise a compact (25 m) 1 GeV pro ton accelerator, according to simulation results*. A four cavity electron counterpart is under construction to test the mechanism of the multi-cavity setup, including phase acceptance, energy gain, and growth of energy spread and emittance for parameters equivalent to the proton case. The four electron counterpart cavities are driven by kW-level phase coherent RF sources at 1.5, 1.8, 2.1 and 2.4 GHz. Each cavity operates in the rotating TE111 mode and includes two feeds in quadrature to drive the rotating mode and two RF pickoffs for diagnostics. The electron beam source is a low-current gun with a BaO cathode which operates at -1200V and <50 microamps. After traversing the cavities, the beam is collected on either a Faraday cup or is imaged with a phosph or screen. Details of the setup and initial results from experiments with the four cavity electron counterpart will be presented.

43 PARTICLE ACCELERATORS↗

Progress in the Development of a High Power Helicon Plasma Source for the Materials Plasma Exposure Experiment

Proto-MPEX is a linear plasma device being used to study a novel RF source concept for the planned Material Plasma Exposure eXperiment (MPEX), which will address plasma-materials interaction (PMI) for nuclear fusion reactors. Plasmas are produced using a large diameter helicon source operating at a frequency of 13.56 MHz at power levels up to 120 kW. In recent experiments the helicon source has produced deuterium plasmas with densities up to ~6 × 1019 m–3 measured at a location 2 m downstream from the antenna and 0.4 m from the target. Previous plasma production experiments on Proto-MPEX have generated lower density plasmas with hollow electron temperature profiles and target power deposition peaked far off axis. The latest experiments have produced flat Te profiles with a large portion of the power deposited on the target near the axis. This and other evidence points to the excitation of a helicon mode in this case.

Goulding, Richard↗

50 MW X-BAND RF SYSTEM FOR A PHOTOINJECTOR TEST STATION AT LLNL

In support of X-band photoinjector development efforts at LLNL, a 50 MW test station is being constructed to investigate structure and photocathode optimization for future upgrades. A SLAC XL-4 klystron capable of generating 50 MW, 1.5 microsecond pulses will be the high power RF source for the system. Timing of the laser pulse on the photocathode with the applied RF field places very stringent requirements on phase jitter and drift. To achieve these requirements, the klystron will be powered by a state of the art, solid-state, high voltage modulator. The 50 MW will be divided between the photoinjector and a traveling wave accelerator section. A high power phase shifter is located between the photoinjector and accelerator section to adjust the phasing of the electron bunches with respect to the accelerating field. A variable attenuator is included on the input of the photoinjector. The distribution system including the various x-band components is being designed and constructed. In this paper, we will present the design, layout, and status of the RF system.

42 ENGINEERING↗

SLED-II: A New Method of RF Pulse Compression

In the SLED 1 method of RF pulse compression, two high Q resonators store energy from an RF source for a relatively long time interval (typically 3 to 5 J.1sec). Triggered by a reversal in RF phase, this stored energy is then released during a much shorter interval equal to the filling time of the accelerating structure. A peak power gain on the order of three and a compression efficiency on the order of 60% are typically attained. The shape of the output pulse is, however, a sharply decaying expo- nential. In SLED-II the two cavities are replaced by two lengths of resonant line, forming a Resonant Line SLED (RELS) and resulting in a flat output pulse. Therefore, RELS stages can be cascaded to give a greater peak power gain. Using two stages, a peak power gain greater than ten can be achieved with a reasonable compression efficiency. Unlike the BEC,2 the RELS compression fac- tor per stage is not limited to two, albeit at the expense of intrinsic efficiency. Like the BEC, it uses long lines rather than short cavities.

Farkas, Z.↗

Diagnostics of the ITER neutral beam test facility

The ITER heating neutral beam (HNB) injector, based on negative ions accelerated at 1 MV, will be tested and optimized in the SPIDER source and MITICA full injector prototypes, using a set of diagnostics not available on the ITER HNB. The RF source, where the H{sup -}/D{sup -} production is enhanced by cesium evaporation, will be monitored with thermocouples, electrostatic probes, optical emission spectroscopy, cavity ring down, and laser absorption spectroscopy. The beam is analyzed by cooling water calorimetry, a short pulse instrumented calorimeter, beam emission spectroscopy, visible tomography, and neutron imaging. Design of the diagnostic systems is presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling and simulation of a beam emission spectroscopy diagnostic for the ITER prototype neutral beam injector

A test facility for the development of the neutral beam injection system for ITER is under construction at Consorzio RFX. It will host two experiments: SPIDER, a 100 keV H{sup −}/D{sup −} ion RF source, and MITICA, a prototype of the full performance ITER injector (1 MV, 17 MW beam). A set of diagnostics will monitor the operation and allow to optimize the performance of the two prototypes. In particular, beam emission spectroscopy will measure the uniformity and the divergence of the fast particles beam exiting the ion source and travelling through the beam line components. This type of measurement is based on the collection of the H{sub α}/D{sub α} emission resulting from the interaction of the energetic particles with the background gas. A numerical model has been developed to simulate the spectrum of the collected emissions in order to design this diagnostic and to study its performance. The paper describes the model at the base of the simulations and presents the modeled H{sub α} spectra in the case of MITICA experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipulse Optical-Rectification-Based THz Source for Accelerator Applications

THz sources offer the potential for higher frequencies and higher breakdown thresholds in accelerating structures in comparison with conventional RF sources. They also benefit from larger field strengths, field gradients, better beam synchronization and compactness. In this work, we first present the development of a 49μJ single-cycle THz source centered at 0.6 THz that provides fields over 30 MV/m. With further modifications, multicycle pulses were produced, narrowing the bandwidth of the source and potentially easing the coupling of THz radiation to relativistic electron beams and increasing the usability in other areas of research.

Lenz, Maximilian (ORCID:0009000579693042)↗

High efficiency normal conducting linac for environmental water remediation

A continuous wave (CW) electron accelerator for the treatment of industrial streams including an electron beam source, a modified high efficiency slot coupled cavity, at least one focusing magnet positioned surrounding the accelerator to contain the beam in the accelerator, an efficient radio frequency power supply means for supplying power of a radio frequency to the cavity to induce a TM01 accelerating mode in the cavity, an electron beam spreader or raster, a fixed magnet array or two-dimensional scanning magnet for deflecting the accelerated beam into a desired shape, and an exit window for extracting the deflected electron beam. The accelerator includes a graded-beta cavity to enable use with a low-power pulsed electron source. The accelerator benefits from a low wall-power loss accelerating cavity that is energized with efficient RF sources, enabling it to be operated in continuous wave mode.

Hannon, Fay↗

Python-EPICS RF Conditioning Automatic Control System at the Spallation Neutron Source

The RF Test Facility (RFTF) at the Spallation Neutron Source (SNS) is used for the conditioning of RF compo-nents such as ceramic vacuum windows and power cou-plers prior to their installation in the H- ion linear accel-erator. This process exposes components to high-power RF fields and thermal cycling to improve performance and remove surface impurities. To automate and optimize this process, a Python-based EPICS control system was developed alongside targeted hardware upgrades. The system enables real-time monitoring and control of RF power levels, temperature, and vacuum pressure. A user-friendly graphical interface was implemented using CS-Studio (Phoebus), allowing operators to adjust parameters and collect data efficiently. The system integrates a High-Power Protection Module (HPM) for interlocks based on vacuum and arc detection, ensuring safe operation. These upgrades have significantly improved the efficiency, accuracy, and safety of RF conditioning at the SNS RFTF. This paper describes the updated RF conditioning sys-tem, highlighting the software and hardware develop-ments and their application in support of the Proton Pow-er Upgrade (PPU) project.

Lee, Sung-Woo [ORNL] (ORCID:000000030915835X)↗

Development of a radio-frequency ion beam source for fast-ion studies on the large plasma device

A helium ion beam source (23 kV/2.0 A) has been constructed for studying fast-ion physics in the cylindrical magnetized plasma of the large plasma device (LAPD). An inductive RF source produces a 10{sup 19} m{sup -3} density plasma in a ceramic dome. A multi-aperture, rectangular (8 cm x 8 cm) three-grid system extracts the ion beam from the RF plasma. The ion beam is injected at a variety of pitch angles with Alfvenic speeds in the LAPD. The beam current is intense enough to excite magnetic perturbations in the ambient plasma. Measurements of the ion beam profile were made to achieve an optimum beam performance and a reliable source operation was demonstrated on the LAPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical modeling of the SNS H{sup −} ion source

Ion source rf antennas that produce H- ions can fail when plasma heating causes ablation of the insulating coating due to small structural defects such as cracks. Reducing antenna failures that reduce the operating capabilities of the Spallation Neutron Source (SNS) accelerator is one of the top priorities of the SNS H- Source Program at ORNL. Numerical modeling of ion sources can provide techniques for optimizing design in order to reduce antenna failures. There are a number of difficulties in developing accurate models of rf inductive plasmas. First, a large range of spatial and temporal scales must be resolved in order to accurately capture the physics of plasma motion, including the Debye length, rf frequencies on the order of tens of MHz, simulation time scales of many hundreds of rf periods, large device sizes on tens of cm, and ion motions that are thousands of times slower than electrons. This results in large simulation domains with many computational cells for solving plasma and electromagnetic equations, short time steps, and long-duration simulations. In order to reduce the computational requirements, one can develop implicit models for both fields and particle motions (e.g. divergence-preserving ADI methods), various electrostatic models, or magnetohydrodynamic models. We have performed simulations using all three of these methods and have found that fluid models have the greatest potential for giving accurate solutions while still being fast enough to perform long timescale simulations in a reasonable amount of time. We have implemented a number of fluid models with electromagnetics using the simulation tool USim and applied them to modeling the SNS H- ion source. We found that a reduced, single-fluid MHD model with an imposed magnetic field due to the rf antenna current and the confining multi-cusp field generated increased bulk plasma velocities of > 200 m/s in the region of the antenna where ablation is often observed in the SNS source. We report here on comparisons of simulated plasma parameters and code performance using more accurate physical models, such as two-temperature extended MHD models, for both a related benchmark system describing a inductively coupled plasma reactor, and for the SNS ion source. We also present results from scaling studies for mesh generation and solvers in the USim simulation code.

07 ISOTOPE AND RADIATION SOURCES↗

Installation of spectrally selective imaging system in RF negative ion source

A spectrally selective imaging system has been installed in the RF negative ion source in the International Thermonuclear Experimental Reactor-relevant negative ion beam test facility ELISE (Extraction from a Large Ion Source Experiment) to investigate distribution of hydrogen Balmer-α emission (H{sub α}) close to the production surface of hydrogen negative ion. We selected a GigE vision camera coupled with an optical band-path filter, which can be controlled remotely using high speed network connection. A distribution of H{sub α} emission near the bias plate has been clearly observed. The same time trend on H{sub α} intensities measured by the imaging diagnostic and the optical emission spectroscopy is confirmed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-consistent electrodynamics of large-area high-frequency capacitive plasma discharge

Capacitively coupled plasmas (CCPs) generated using high frequency (3-30 MHz) and very high frequency (30-300 MHz) radio-frequency (rf) sources are used for many plasma processing applications including thin film etching and deposition. When chamber dimensions become commensurate with the effective rf wavelength in the plasma, electromagnetic wave effects impose a significant influence on plasma behavior. Because the effective rf wavelength in plasma depends upon both rf and plasma process conditions (e.g., rf power and gas pressure), a self-consistent model including both the rf power delivery system and the plasma discharge is highly desirable to capture a more complete physical picture of the plasma behavior. A three-dimensional model for self-consistently studying both electrodynamic and plasma dynamic behavior of large-area (Gen 10, >8 m{sup 2}) CCP is described in this paper. This model includes Maxwell's equations and transport equations for charged and neutral species, which are coupled and solved in the time domain. The complete rf plasma discharge chamber including the rf power delivery subsystem, rf feed, electrodes, and the plasma domain is modeled as an integrated system. Based on this full-wave solution model, important limitations for processing uniformity imposed by electromagnetic wave propagation effects in a large-area CCP (3.05x2.85 m{sup 2} electrode size) are studied. The behavior of H{sub 2} plasmas in such a reactor is examined from 13.56 to 200 MHz. It is shown that various rectangular harmonics of electromagnetic fields can be excited in a large-area rectangular reactor as the rf or power is increased. The rectangular harmonics can create not only center-high plasma distribution but also high plasma density at the corners and along the edges of the reactor.

36 MATERIALS SCIENCE↗