Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “resistive heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Electrical Resistivity Changes During Heating Experiments Unravel Heterogeneous Thermal‐Hydrological‐Mechanical Processes in Salt Formations

Abstract Rock salt is considered a suitable medium for the permanent disposal of heat‐generating radioactive waste due to its isolation properties. However, excavation damage and heating induce complex and heterogeneous thermal‐hydrological‐mechanical (THM) processes across different zones. Quantifying this heterogeneity is crucial for accurate long‐term performance assessment models, but traditional methods lack the necessary resolution. This study employs 4D electrical resistivity tomography (ERT) monitoring during controlled heating experiments in a salt formation to unravel the spatiotemporal dynamics of THM processes. Advanced time‐lapse inversion and clustering analysis quantify subsurface properties and map the heterogeneity of THM dynamics. The ERT results can estimate subsurface properties and delineate the damaged and intact zones, enabling appropriate parameterization and representation of processes for long‐term modeling. This approach may be used in further improving the predictive models and ensuring the safe long‐term disposal of radioactive waste in rock salt.

58 GEOSCIENCES↗

Heat and fire resistant gel seal

A combination seal connects a filter or an equipment component to a base. The combination seal includes a seal material and flecks or particles made of intumescent material interspersed within the seal material. The flecks or particles of intumescent material undergo a chemical change when exposed to flames or heat and expand to maintain seal effectiveness and longevity without compromise.

Brown, Eric P.↗

Burst resistant thin wall heat sink

An method for forming a cooling apparatus for cooling an electronic component. The apparatus has a planar top member of a thermal energy conductive material and a parallel planar bottom member of the material, the planar bottom member including a surface having regions configured for heat exchange contact with the electronic component. The planar top member has a plurality of stamped indent formations at a plurality of locations, each indent formation providing a contact surface such that the planar top member is affixed to the bottom member by braze or solder at each contact surface. Alternatively, the planar bottom member also has a plurality of stamped indent formations in alignment with indent formations of the top member. The planar top member is affixed to the bottom member by brazing or soldering each respective contact surface of an indent formation of the planar top member to an opposing contact surface of a corresponding indent formation of the parallel planar bottom member.

Coteus, Paul W.↗

Dissolution of Nb(C,N) During Post-weld Heat-Treatment of Electric Resistance Welded X70 Line Pipe

The effect of peak temperature for post-weld heat treatment (PWHT) on the dissolution of Nb-rich carbonitrides, Nb(C,N), in the weldline of an electric resistance welded (ERW) X70 grade pipeline steel was investigated. Selected-area electron diffraction patterns and corresponding electron energy loss spectroscopy mappings revealed both Nb-rich carbonitrides and Ti-rich nitrides, (Ti,Nb)N, in the sample heat-treated to 1080 °C peak temperature. However, only Ti-rich nitrides were revealed in the sample heat-treated to 1220 °C peak temperature. During continuous heating to higher than the Ac3 temperature, i.e., near 1100 °C temperature, the dissolution of Nb(C,N) was observed in dilation and derivative of dilation. Notably, this experimental result agreed with the predictions by a DICTRA model. Furthermore, a phenomenological model was developed to explain the volume shrinkage during the dissolution of Nb(C,N) precipitates.

36 MATERIALS SCIENCE↗

Thermal simulation of the EIC HSR interconnect module - RF fingers

The Electron Ion Collider (EIC) Hadron Storage Ring (HSR) will reuse most of the existing superconducting magnets from the RHIC storage ring. However, the existing beam vacuum chamber and stripline BPMs will not be compatible with the planned EIC hadron bunches that will have a 3x higher intensity and be 10x shorter, and some operational scenarios with large radial offsets of the beam in the vacuum chamber. To address these challenges, a copper coated beam screen will be implemented, the existing RHIC stripline BPMs will be shielded and an interconnect module design, including new BPM will be installed adjacent to the existing BPMs. A thermal analysis of the new arc BPM interconnect housing has been conducted to assess the heating caused by beam induced resistive wall heating and electron cloud heating. An analysis of the BPM module has been made and reported separately. This report will focus on the other side of the interconnect module, containing the RF fingers.

43 PARTICLE ACCELERATORS↗

Review of liquid desiccant air dehumidification systems coupled with heat pump: System configurations, component design, and performance

Vapor Compression Systems (VCS) are the most common air conditioning technology. VCS cool the air to its dew point temperature (overcooling) to remove water vapor in the air through condensation and then reheats the air back to the comfort temperature for direct use. The VCS process is inefficient due to overcooling and reheating. Liquid Desiccant Dehumidification (LDD) is a potentially energy-efficient air conditioning. LDD removes water vapor in the process air using liquid desiccant’s high-water affinity. It hybrids with sensible cooling to control temperature and humidity separately. The LD in the LDD becomes weak after dehumidification. The LDD needs additional heating to regenerate the weak Liquid Desiccant (LD) to a high concentration for dehumidification. Earlier versions of the LDD systems use highly concentrated liquid desiccant (large water removal capability) to dehumidify the air by only dealing with latent load. It leads to highly elevated temperatures above 60 °C of heat sources (combustion or electric resistance-based heating) for regeneration. The energy needed for the elevated temperature heat resource significantly reduces or demolishes the benefit of LDD systems. In the recent two decades, researchers have investigated a new configured LDD system that couples an LDD with a heat pump at both dehumidification and regeneration sides for better efficiency. The heat pump provides cooling (from the evaporator) for both dehumidification and sensible cooling and simultaneous heating from the condenser for regeneration. The highly integrated system (HP-LDD) with improved efficiency enables the LDD to operate at lower concentrations and temperatures in dehumidification and regeneration. This paper depicts the working principle behind HP-LDD and its heating and cooling requirements. It reviews the comparison between the HP-LDD systems and the conventional LDD systems regarding system configurations, component design, energy efficiency, and dehumidification performance characteristics. The main findings from the review include the preferred use of packed bed over membrane-based dehumidifiers, the use of internally cooled dehumidifiers enabled by the HP cooling capacity, the high dispersion of HP operation conditions, and the dependence of dehumidification performance on various dehumidifiers. Finally, an outlook for future research on HP-LDD strategies is presented based on the reviewed works and their limitations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improvement of Coal Power Plant Dry Cooling Technology through Application of Cold Thermal Energy Storage

The U.S. power infrastructure is currently heavily reliant on water cooling. The power plants in the U.S. account for approximately 40% of freshwater withdrawals, with 90% of it used in condenser cooling. The most used cooling technology in coal-fired power plants is a once-through condenser; however, this cooling method requires high water withdrawal rates and results in thermal pollution of the water source. Wet WCTs offer an alternative to once-through condensers due to much lower water withdrawals. However, these systems suffer from water consumption through evaporation making them undesirable options in areas subject to droughts and in arid areas. The direct dry cooled condensers (ACCs) and dry cooling towers (DCT) account for 1.8%, hybrid cooling (ACC + WCT) accounts for 0.5%, while other cooling technologies represent the rest (0.7%). The ACC/DCTs represent an attractive alternative for power plants; however, this technology has not been widely adopted in the US (less than 2% of power plants) due to its negative impact on plant performance. As a rule of thumb, dry cooling results in performance penalty equivalent to approximately 2%-point efficiency loss compared to wet cooling, although the actual magnitude varies with ambient dry bulb temperature, DBT which may vary considerably during the day. As DBT increases, the plant power output decreases, reaching a minimum at the hottest period of the day, which usually coincides with the highest electricity demand for air condition load. Therefore, performance of power plants using DCT/ACC cooling technology is the lowest during the summer mid-day when ambient temperature is the highest. For example, the decrease of the inlet air temperature to the DCT/ACC by 2 Deg C could generate up to 5% additional power at peak demand. It is, therefore, important to improve dry cooling technology to maintain the viability of coal-fired power plants in a carbon constrained future. The method for reducing the cooling air temperature and keeping it constant would mitigate this problem significantly. Objectives of this project were to develop, design, evaluate, and demonstrate a cost-effective system for improving performance of a DCT or ACC for thermal (coal-fired) power plant applications using a low-cost heat storage materials, such as pervious concrete (PC) and phase change material (PCM). Thus, the study focused on development of the system(s) that could be used to alleviate the difficulties in operating DCT/ACC during the summer months by storing cold energy during the nighttime in inexpensive materials PC and PCM and using it during the hottest period(s) of the day. Since very large quantities of cold energy need to be stored to make an impact on performance of a large power plant, it is essential that the storage materials and associated cold energy storage design(s) are inexpensive and the system is simple to build, maintain and operate. To achieve the project objectives, a comprehensive approach, including material development and characterization, component and system modeling, and laboratory- and prototype-scale experiments, was employed including modeling of the system components and of the entire system, development (engineering) of the materials for the heat storage modules of the Cold Thermal Energy Storage System (CTESS) and determination of their properties, design, manufacturing and setup of the laboratory- and prototype-scale test facility and testing, design, manufacturing and setup of the prototype-scale test facility. A modular design of CTESS was employed, where representative modules were designed as the integrated direct contact heat exchanger and thermal energy storage (TES) system. CTESS modules were manufactured and tested. Two prototype-scale designs of the CTESS modules were developed and tested. The use of CTESS increases plant generation increases since it lowers air temperature entering ACC/DCT and keeps it constant during the hottest time of the day. For a PCM-based CTESS, the ambient air temperature is lowered close to the PCM phase change temperature. The duration of the cooling effect depends on the latent heat and mass of PCM in the CTESS. For this project, commercial grade CaCl2 hexahydrate (CaCl2·6H2O or CC6) PCM with phase change temperature of 25 Deg. C was used due to its low cost. For practical reasons, the CTESS was designed to maintain the cooling effect for four hours. The low phase change temperature associated with the commercial grade PCM used in CTESS results in considerably higher improvement in net generation compared to the laboratory (pure) grade. The resistance to heat transfer results in lower net generation compared to the ideal case where resistance to heat transfer is zero. The results demonstrate that CTESS is effective in improving the performance of a dry cooling system. However, its effectiveness depends on the relationship between the ambient air conditions and PCM phase change temperature. As is the case with the heat rejection system, for the best performance, the PCM used in CTESS would need to be matched to the ambient air conditions. The results obtained in this report for selected geographical locations are valid for CC6 and demonstrate that the level of performance to be achieved by the technology will be location-dependent, as is the case with the air cooled condensers. The methodology for engineering of PC-PCM-based heat storage medium is applicable to other PCMs that may need to be used for other ambient air conditions and geographical locations.

01 COAL, LIGNITE, AND PEAT↗

Harnessing dimethyl ether with ultra-low-grade heat for scaling-resistant brine concentration and fractional crystallization

Solvent-driven separations may enable scalable concentration of hypersaline brines, supporting a circular resource economy from the extraction of lithium and rare earth elements from spent battery and magnet leachates. This work analyses a novel solvent-driven water extraction (SDWE) system employing dimethyl ether (DME) and ultra-low-grade heat for brine concentration and fractional crystallization. SDWE exploits DME’s unique properties: (1) a low dielectric constant that promotes water solubility over charged solutes by a factor of 10 3 , and (2) a high volatility that facilitate efficient DME reconcentration with ultra-low-grade heat. The techno-economic viability of SDWE is assessed with a computational framework that encompasses a liquid–liquid separator and a solvent concentrator. We integrate the extended universal quasichemical model with the virial equation of state to predict the compositions of the complex three-phase DME-water mixture at vapor–liquid and liquid–liquid equilibrium. Subsequently, we optimize the thermodynamic and economic performance of SDWE, by controlling the interstage flash pressure, heat source temperature, and the number of concentrating stages. DME-based SDWE concentrates an input saline feed to 5.5 M and regenerates over 99 % of the DME using ultra-low-grade heat below 50 °C, with a DME/water selectivity ratio of 125. Here our calculations reveal that optimal performance is achieved at interstage flash pressures of 0.4 – 0.5 bar for heat source temperatures between 323–373 K, with improved exergetic efficiencies at lower temperatures. At a heat source temperature of 323 K and an interstage pressure of 0.489 bar, DME-driven SDWE achieves an optimal thermodynamic efficiency of 20.5 % and a projected specific cost of US$ 1.93 m -3 . These specific costs suggest that SDWE is competitive with commercialized thermal distillation technologies, while mitigating the traditional risks associated with scaling in heat and mass exchangers with hypersaline brines.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Superconductivity in WBe 2

WBe 2 , which occurs in space group 194, with hexagonal symmetry P6 3 /mmc, is prepared by arc-melting at temperatures above 2200 C, where Be vapor loss is significant. This study is motivated by recent work on MoB 2 and WB 2 , both superconductors (T c =32 and 17 K respectively) under high (∼70 GPa) pressure. In order to avoid the known Be-rich superconducting phases (WBe 13 and WBe 22 ) in the complex phase diagram, both known to be superconducting at 4.1 K, the sample was prepared with a slight (∼5 %) excess of W. The resultant sample, prepared using high purity (99.999 %) Be, is essentially single phase WBe 2 , with some spread in its superconducting properties due to the known homogeneity range. (WBe 2 forms in space group 194 between approximately W 1.02 Be 1.98 and W 0.88 Be 2.12 .) Characterization was carried out with x-ray diffraction, electrical resistivity, ρ, in zero and applied magnetic fields, and specific heat. The resistivity in zero and applied fields and specific heat data indicate that our sample of WBe 2 is a bulk superconductor at ambient pressure with a T c onset in ρ at 1.05 K, and T c (ρ→0) at ∼0.86 K. Furthermore, there is no signature of superconductivity in ρ at 4.1 K, indicating successful avoidance of WBe 13 and WBe 22 . The ρ data in field indicate an upper critical field of approximately 400 gauss.

Electrical transport↗

Cast Alumina-Forming Austenitic Stainless Steels for High Temperature Heat Treatment Furnace Rolls

Alloy developers worldwide have struggled to create creep-resistant alumina-forming, iron-based austenitic stainless steels for use as high-temperature structural alloys, but with limited success in balancing alloy cost, oxidation, and creep resistance. Here, this article describes the research and development of a novel cast alumina-forming austenitic stainless steel. This work won the prestigious Engineering Materials Achievement Award presented at IMAT 2023 in Detroit.

36 MATERIALS SCIENCE↗

A New Analytical Expression for Estimating the Adiabatic Temperature Rise in Lithium-Ion Batteries During High-Power Pulses

A coupled, thermal-electrochemical model is used to explain why the Joule heating assumption (i.e., I 2 R) does not provide a good representation of the temperature rise during high power pulses in lithium-ion batteries, even in cases where the reversible heat generation can be neglected. The poor agreement occurs because the internal resistance changes during the pulse due to the opposing effects of mass transport in the electrolyte, which raises the resistance, and heat generation (temperature rise), which lowers the resistance. These insights are used to propose a new analytical expression for predicting the temperature rise during adiabatic pulses with limited experimental and physical data. The expression accounts for thermal effects using a Taylor series expansion of an Arrhenius-type equation. It accounts for transport effects using an approximate solution to the one-dimensional diffusion equation. The new expression is shown to accurately estimate the simulated, adiabatic temperature rise across a range of loadings (1 to 4 mAh cm -2 ) and C-rates (1C to 10C) for cells containing LiNi 0.5 Mn 0.3 Co 0.2 O 2 positive electrodes and graphite negative electrodes. In conclusion, it is also shown to accurately estimate the experimental, adiabatic temperature rise measured for cells with LiFePO 4 positive electrodes and mesocarbon negative electrodes with minimal changes to the fitted parameters.

25 ENERGY STORAGE↗

Quantum criticality in Ce 1 - x Sm x Co In 5

Motivated by the possibility of observing the coexistence between magnetism and unconventional superconductivity in heavy-fermion Ce 1-x Sm x CoIn 5 alloys, we studied how the samarium substitution on the cerium site affects the magnetic field-tuned-quantum criticality of stoichiometric CeCoIn 5 by performing specific heat and resistivity measurements. By applying an external magnetic field, we have observed Fermi-liquid to non-Fermi-liquid crossovers in the temperature dependence of the electronic specific heat normalized by temperature and of the resistivity. We obtained the magnetic-field-induced quantum critical point (QCP) by extrapolating to zero temperature the temperature-magnetic field dependence at which the crossovers take place. Furthermore, a scaling analysis of the electronic specific heat is used to confirm the existence of the QCP. We have found that the magnitude of the magnetic-field-induced QCP decreases with increasing samarium concentration. Our analysis of heat capacity and resistivity data reveals a zero-field QCP for x cr ≈0.15, which falls inside the region where Sm ions antiferromagnetism and superconductivity coexist.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Seeding the explosion of a high-current-density conductor in a controlled manner through the addition of micron-scale surface defects

Inhomogeneities in a current-carrying conductor promote non-uniform heating and expansion through the complex feedback between current density, electrical resistivity, Ohmic heating, temperature, and hydrodynamics. Three-dimensional-magnetohydrodynamic (3D-MHD) simulations suggest that μm-scale resistive inclusions or voids seed local overheating and through hydrodynamic explosion generate continuously growing craters which become several times larger than the initial perturbation. The ejected mass is the genesis of an electrothermally driven plasma filament which develops at lower current than plasmas on uniform surfaces adjacent to the defect. This result suggests that 1D or even 2D treatments are largely inadequate for detailed prediction of plasma formation. To test computational predictions, z-pinch experiments driven to 1 MA studied ultra-high-purity aluminum rods which were then machined to include pairs of quasi-hemispherical voids or “engineered defects (ED)” on the current-carrying surface. ED are the dominant current-density perturbation and reproducibly drive local overheating which can be compared with 3D-MHD simulation. Data from high-resolution-gated imagers of visible surface emissions confirm many simulation predictions, including the surface topography of local overheating, and the propensity for neighboring ED to prematurely source plasmas which then connect to form a plasma filament. Results also provide conditional support of theory which suggests heating similarity; that is, heating is independent of ED size for geometrically scaled ED.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement and analysis of clothes dryer air leakage

Each year clothes dryer appliances are sold globally in the tens of millions. Both vented and ventless types are common and are heated by combustion, electric resistance, or electric heat pumps. In the dyer air path, segments can be defined between components such as the drum, blower, filter, screens or grills, and heat exchangers (where applicable). In this work, a technique was developed to experimentally measure air leakage into and from the segments of a clothes dryer. Detailed leakage measurements were taken on two vented and one ventless residential clothes dryer. The measurements were quantified as a leakage flow coefficient for each segment. For two dryers (one vented and one ventless), these flow coefficients were combined with in situ operating pressure measurements to determine leakage flow rates for each segment. For these two units under normal operation with air pressures within 0.5 kPa (50 mm water column) of ambient pressure, volumetric system air leakage was found to be about 20–60% of the blower airflow. Furthermore, a quasi–steady state psychrometric analysis was conducted on vented dryers with negatively pressurized drums. The analysis revealed that leakage quantity, location, and direction are essential to achieving an acceptable energy balance and accurate modeling results for a vented heat pump clothes dryer but are of limited significance for vented electric resistance clothes dryers.

42 ENGINEERING↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air-Source Heat Pumps

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climate conditions. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in northwest United States and one in Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five-seconds, to calculate heat pump's capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides valuable insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving the overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Auxiliary Heat Use for Cold Climate Operation of Air Source Heat Pumps: Preprint

This paper investigates the auxiliary heat use for air-source heat pumps (ASHPs) operating in cold climates. Twelve variable-capacity, central ducted ASHPs installed in single-family homes in cold climate regions (eleven in the northwest United States and one in a Denver suburb) were monitored for an entire winter season to collect data at cold temperatures. The methodology employed airside and power measurements that were taken every five seconds, to calculate the heat pump’s capacity, coefficient of performance (COP), and auxiliary heat energy consumption. This paper provides insights into the practical implications of auxiliary heat utilization in centrally ducted ASHPs and suggests opportunities to mitigate the usage of auxiliary heat, improving overall system efficiency during cold climate operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗