Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “refrigerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Shock isolator for diode laser operation on a closed-cycle refrigerator

Closed-cycle helium refrigerators are widely used as coolers for semiconductor diode lasers. These refrigerators pose several difficulties including temperature oscillations due to varying refrigerator capacity during the Solvay cycle, and impact shocks delivered to the diode in the cycle's expansion phase. A shock isolator has been designed to isolate diode lasers from such impact shocks. Slow diode current scans have been made before installation of the shock isolator, with the isolator but no thermal damper, and with both devices. With the isolator and no damper, the diode output frequency oscillated at the refrigerator cycle rate, deviating by plus or minus 40 MHz. Using the isolator and the damper no frequency fluctuation was detected.

Jennings, D. E.↗

Spacecraft-borne long life cryogenic refrigeration: Status and trends

The status of cryogenic refrigerator development intended for, or possibly applicable to, long life spacecraft-borne application is reviewed. Based on these efforts, the general development trends are identified. Using currently projected technology needs, the various trends are compared and evaluated. The linear drive, non-contacting bearing Stirling cycle refrigerator concept appears to be the best current approach that will meet the technology projection requirements for spacecraft-borne cryogenic refrigerators. However, a multiply redundant set of lightweight, moderate life, moderate reliability Stirling cycle cryogenic refrigerators using high-speed linear drive and sliding contact bearings may possibly suffice.

Johnson, A. L.↗

Joule Thomson refrigerator

A bi-directional Joule Thomson refrigerator is described, which is of simple construction at the cold end of the refrigerator. Compressed gas flowing in either direction through the Joule Thomson expander valve and becoming liquid, is captured in a container in direct continuous contact with the heat load. The Joule Thomson valve is responsive to the temperature of the working fluid near the valve, to vary the flow resistance through the valve so as to maintain a generally constant flow mass between the time that the refrigerator is first turned on and the fluid is warm, and the time when the refrigerator is near its coldest temperature and the fluid is cold. The valve is operated by differences in thermal coefficients of expansion of materials to squeeze and release a small tube which acts as the expander valve.

Chung K Chan↗

Efficiency Calculations For a Magnetic Refrigerator Operating Between 2K and 10K

An adiabatic demagnetization refrigerator (ADR) is being developed at NASA-Ames Research Center. The ADR will operate between 2 K and 10 K and will provide 50 mW of cooling at 2 K. The refrigerant in the ADR is Gadolinium Gallium Garnet (GGG). Absorption of heat at 2 K and heat rejection at 10 K in this fully static refrigerator is made possible by the incorporation of 2 K and 10 K heat switches. Physical layout and experimental results are presented in a parallel paper. The present paper discusses the thermal losses associated with components of the ADR as they occur in various parts of the refrigeration cycle. The results are summarized in terms of a prediction for the ADR efficiency.

Helvensteijn, Ben P. M.↗

Solar-Powered Refrigeration System

A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure. and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

Ewert, Michael K.↗

Solar Powered Refrigeration System

A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

Michael K Ewert↗

Solar-Powered Refrigeration System

A solar powered vapor compression refrigeration system is made practicable with thermal storage and novel control techniques. In one embodiment, the refrigeration system includes a photovoltaic panel, a variable speed compressor, an insulated enclosure, and a thermal reservoir. The photovoltaic (PV) panel converts sunlight into DC (direct current) electrical power. The DC electrical power drives a compressor that circulates refrigerant through a vapor compression refrigeration loop to extract heat from the insulated enclosure. The thermal reservoir is situated inside the insulated enclosure and includes a phase change material. As heat is extracted from the insulated enclosure, the phase change material is frozen, and thereafter is able to act as a heat sink to maintain the temperature of the insulated enclosure in the absence of sunlight. The conversion of solar power into stored thermal energy is optimized by a compressor control method that effectively maximizes the compressor's usage of available energy. A capacitor is provided to smooth the power voltage and to provide additional current during compressor start-up. A controller monitors the rate of change of the smoothed power voltage to determine if the compressor is operating below or above the available power maximum, and adjusts the compressor speed accordingly. In this manner, the compressor operation is adjusted to convert substantially all available solar power into stored thermal energy.

Michael K Ewert↗

Integrated Electron-tunneling Refrigerator and TES Bolometer for Millimeter Wave Astronomy

We describe progress in the development of a close-packed array of bolometers intended for use in photometric applications at millimeter wavelengths from ground- based telescopes. Each bolometer in the may uses a proximity-effect Transition Edge Sensor (TES) sensing element and each will have integrated Normal-Insulator-Superconductor (NIS) refrigerators to cool the bolometer below the ambient bath temperature. The NIS refrigerators and acoustic-phonon-mode-isolated bolometers are fabricated on silicon. The radiation-absorbing element is mechanically suspended by four legs, whose dimensions are used to control and optimize the thermal conductance of the bolometer. Using the technology developed at NIST, we fabricate NIS refrigerators at the base of each of the suspension legs. The NIS refrigerators remove hot electrons by quantum-mechanical tunneling and are expected to cool the biased (approx.10 pW) bolometers to <170 mK while the bolometers are inside a pumped 3He-cooled cryostat operating at approx.280 mK. This significantly lower temperature at the bolometer allows the detectors to approach background-limited performance despite the simple cryogenic system.

Silverberg, R. F.↗

Control system for thermoelectric refrigerator

Apparatus including a power supply (202) and control system is provided for maintaining the temperature within an enclosed structure (40) using thermoelectric devices (92). The apparatus may be particularly beneficial for use with a refrigerator (20) having superinsulation materials (46) and phase change materials (112) which cooperate with the thermoelectric device (92) to substantially enhance the overall operating efficiency of the refrigerator (20). The electrical power supply (202) and control system allows increasing the maximum power capability of the thermoelectric device (92) in response to increased heat loads within the refrigerator (20). The electrical power supply (202) and control system may also be used to monitor the performance of the cooling system (70) associated with the refrigerator (20).

Nelson, John L.↗

Enclosure for thermoelectric refrigerator and method

An enclosed structure is provided for use with a refrigerator having a door assembly. The enclosed structure preferably contains superinsulation materials and a plurality of matching drawers. The enclosed structure preferably includes corner joints which minimize thermal energy transfer between adjacent superinsulation panels. The refrigerator may include a cooling system having a thermoelectric device for maintaining the temperature within the refrigerator at selected values. If desired, a fluid cooling system and an active gasket may also be provided between the door assembly and the enclosed structure. The fluid cooling system preferably includes a second thermoelectric device to maintain the temperature of fluid flowing through the active gasket at a selected value. The drawers associated with the refrigerator may be used for gathering, processing, shipping and storing food or other perishable items.

Park, Brian V.↗

A Reversible Thermally Driven Pump for Use in a Sub-Kelvin Magnetic Refrigerator

A document describes a continuous magnetic refrigerator that is suited for cooling astrophysics detectors. This refrigerator has the potential to provide efficient, continuous cooling to temperatures below 50 mK for detectors, and has the benefits over existing magnetic coolers of reduced mass because of faster cycle times, the ability to pump the cooled fluid to remote cooling locations away from the magnetic field created by the superconducting magnet, elimination of the added complexity and mass of heat switches, and elimination of the need for a thermal bus and single crystal paramagnetic materials due to the good thermal contact between the fluid and the paramagnetic material. A reliable, thermodynamically efficient pump that will work at 1.8 K was needed to enable development of the new magnetic refrigerator. The pump consists of two canisters packed with pieces of gadolinium gallium garnet (GGG). The canisters are connected by a superleak (a porous piece of VYCOR glass). A superconducting magnetic coil surrounds each of the canisters. The configuration enables driving of cyclic thermodynamic cycles (such as the sub-Kelvin Active Magnetic Regenerative Refrigerator) without using pistons or moving parts.

Miller, Franklin K.↗

Continuous Sub-Kelvin Cooling from an Adiabatic Demagnetization Refrigerator

We present the current state of development for a continuous magnetic refrigeration system capable of cooling a detector array or other payload to temperatures below 50 mK. This adiabatic demagnetization refrigerator contains four-stages that are cycling continuously yet present a constant ultra-low temperature heat sink at one physical location within the refrigerator. Two different configurations of essentially the same cooler will be presented where the difference is in the physical layout of the stages and the type of heat sink used for the refrigerator's heat rejection.

Magnetic Cooling↗

Electrohydrodynamic (EHD) Refrigerant Pump

An electrohydrodynamic (EHD) pump increases refrigerant flow rate and the resulting pressure in a vapor compression based cooling system for permitting reduced compressor sizes and power demands. The EHD pump disposes electrodes in a liquid path of the refrigerant flow, and increases fluid flow and resulting pressure by an induced liquid flow between a pair of asymmetric electrodes. Voltage applied to these electrodes results in a conduction pumping mechanism associated with heterocharge layers in the vicinity of the electrodes based on disassociation of a neutral electrolyte species in the refrigerant fluid and recombination of the generated ions. The induced flow draws the liquid due to a net fluid flow toward one of the electrodes based on the asymmetry of the electrode pair. Electrodes are disposed on an inner surface of a refrigerant vessel, in communication with an annular liquid film that forms around the inner circumference in two-phase fluid systems.

Yagoobi, Jamal S.↗

Development of a Portable Stand-Alone 20 K Brayton Cycle Helium Refrigeration System

From 2012 to 2015, NASA funded development of the Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) at Kennedy Space Center that scaled up and matured Integrated Refrigeration and Storage (IRAS) technology. IRAS involves the integration of an external helium refrigeration system with a cryogenic storage tank via an internal heat exchanger and allows advanced operations such as zero boiloff and densification of the liquid. The refrigeration system employed for GODU-LH2 was a Linde LR1620 piston-Brayton cycle machine with an RSX helium compressor. The GODU-LH2 system was installed in two separate shipping containers—one housing the cold-box, compressor, and gas management hardware, and the other the water chiller unit—with 480 VAC and 120 VAC electrical power fed from external hardware at the test site, and data capture and controls achieved using four different, independent software packages. From 2017 to 2019, in support of a densified hydrogen loading test program, the entire system was repackaged into a single, 40’ (12 m) shipping container, including the refrigeration system, water chiller, and electrical power distribution hardware, and controls were consolidated into a single Allen Bradley PanelView. Details regarding the design, build-out, and testing of the system will be presented and discussed.

W F Reaves↗

Material Compatibility of 3D Printed Polymer Composites with Low GWP Refrigerants

The recent development of 3D printing brings numerous opportunities to develop polymer heat exchangers with desired configurations and allows access to the new complex engineering design for better performance. To be used in the HVAC&R system, the compatibility of these materials to refrigerants needs to be thoroughly investigated and understood. This study tested the material compatibility of the printed polymer composites according to the ASHRAE Guideline 38 using metal pressure vessels. These printed parts were tested with R-134A, R-1234YF, R-1234ZE, R-1233ZD(E), and 32-3 MAF POE (10 wt.%) was used as the lubricants. The change in volume, mass, hardness, and mechanical properties was studied in detail. Different compatibility of the composites with refrigerants was observed when the composition of the composite changed. After exposure to refrigerants, the morphological and thermal properties were studied with the scanning electron microscope, thermogravimetric analysis, and differential scanning calorimetry to further reveal the influence of these refrigerants.

Li, Kai↗

Optimization of a Residential Air Source Heat Pump using Refrigerants with GWP <150 for Improved Performance and Reduced Emission

Using low-GWP refrigerants can reduce the Green House Gas (GHG) emission of heat pump systems. Heat exchangers and compressors are the key components and have a prominent impact on system performance, significant research is devoted to reducing the cost of the heat exchangers while achieving the same or better system performance with refrigerant charge reduction.To better understand the environmental impacts of optimized systems with low-GWP refrigerants, Life Cycle Climate Performance (LCCP) evaluation method was used to evaluate the direct and indirect emissions of the system over the course of its lifetime from manufacturing to disposal. The DOE/ORNL Heat Pump Design Model (HPDM) is used to evaluate the performance of heat pumps. Multi-objective optimizations using Particle Swarm Optimization (PSO) algorithm are performed on a 3-ton R410A residential air source heat pump on market. Seven R410A alternatives, i.e., R32, R454B, R454C, R455A, R457A, R1234yf and R1234ze(E) are investigated. The last five fluids have GWP lower than 150.As a result, 5.5%-12.8% seasonal energy efficiency ratio 2 (SEER2) improvement is achieved, and the optimized systems reduce life cycle CO2 emission by 8.5%-28.6% with GWP lower than 150 refrigerants. The optimal heat exchangers can fit into the original R410A fan-coil units; therefore, the proposed design method establishes a production and installation path to produce cost-effective low-GWP heat pumps easily accepted by end users.

Li, Zhenning↗

Direct Expansion Heat Pump Using High Glide Low GWP Refrigerant

Next generation of refrigerants require drastically lower global warming potential (GWP). The refrigerant mixtures, with a GWP < 150, e.g., R-457A, etc., tend to have significant temperature glide, which prefer multi-row, cross counter flow configuration. Typical heat pump operation reverses the refrigerant flow direction, compared to the air flow, from cooling mode to heating mode. It is difficult to configurate cross counter-flow heat exchangers in heat pumps. We invented an innovative configuration, having check valve assembly to maintain uniform cross counter flow configuration in both cooling and heat modes, which optimizes the performance of a high temperature slide refrigerant mixture, i.e. R-457A. Based on it, we developed a laboratory prototype, using a 2-stage compressor, achieved a cooling SEER (cooling seasonal energy efficiency rating) of 16.0 (cooling seasonal COP of 4.69) and a heating HSPF (heating seasonal performance factor) > 9.5 (heating seasonal COP of 2.78). The unit was tested in an extensive ambient condition, heating operation from 5˚F to 62˚F (-15˚C to 16.7˚C); cooling operation from 82˚F to 95˚F (27.8˚C to 35˚C). The paper will introduce the system configuration, heat exchanger dimensions and laboratory investigations.

Shen, Bo↗

Experimental Study on Flow Condensation of Low Global Warming Potential Refrigerants in a Micro-fin Aluminum Tube

This study investigates the dynamic shifts in refrigerant technologies driven by environmental regulations, particularly emphasizing low global warming potential (GWP). Moreover, there is a rising trend in the adoption of aluminum tubes with internal axial micro-fin structures in heat exchangers to reduce costs. The research focuses on the condensation process within an expanded axial micro-fin aluminum tube with a 5.96 mm fin-tip diameter. Various refrigerants are analyzed, including both single compounds (R-32, R-1234yf, R-1234ze(E)) and zeotropic mixtures (R-454B, R-454C, R-455A). Experimental procedures cover a range of condensation temperatures (35~45 °C), reduced pressures (0.21~0.55), and mass fluxes (150~350 kg/(m² s)), providing crucial data on heat transfer coefficients (HTC) and frictional pressure gradient (FPG). This data is particularly significant for high-glide refrigerants and is instrumental in the design of advanced air conditioning and refrigeration systems aimed at mitigating global warming.

Hu, Yifeng↗