Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “real-time measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Chatbots can guide experimentalists to avoid many common mistakes in measuring fluorescence spectra

The concepts of fluorescence spectroscopy are well established, yet the experimental collection of a spectrum is susceptible to a range of errors. A recent study showed that chatbots – derived from substantial advances in artificial intelligence – can provide practical assistance to the experimentalist during collection of absorption spectra and thereby achieve improved quality. Fluorescence, while the complement of absorption, is prone to a far richer array of experimental errors encompassing environmental factors, instrumental settings, and experimentalist mistakes. Here, 10 chatbots (ChatGPT 5, Gemini 2.5 Pro, Microsoft Copilot, Meta AI Llama 4, Claude Sonnet 4.5, X.ai Grok 4, Perplexity Pro, DeepSeek V3.1, Z.ai GLM-4.6, and KIMI K2) have been evaluated for the suitability in providing quality-improvement advice to the experimentalist during acquisition of fluorescence spectra. Significant opportunities for practical assistance are noted, although intervention by a domain expert is often required. Here, if combined with image recognition and/or signal processing, chatbots embedded in instruments may enable real-time guidance during fluorescence data acquisition.

Artificial intelligence↗

Irradiation Testing of Ultrasonic Transducers

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of numerous parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). This test will be an instrumented lead test; and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. By characterizing magnetostrictive and piezoelectric transducer survivability during irradiation, test results will enable the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers

Daw, J.↗

Ultrasonic Transducer Irradiation Test Results

Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 . A multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program also provided initial support for this effort. This irradiation, which started in February 2014, is an instrumented lead test and real-time transducer performance data are collected along with temperature and neutron and gamma flux data. The irradiation is ongoing and will continue to approximately mid-2015. To date, very encouraging results have been attained as several transducers continue to operate under irradiation.

Daw, Joshua↗

Progress Towards Developing Neutron Tolerant Magnetostrictive and Piezoelectric Transducers

Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two magnetostrictive transducers were fabricated with Remendur or Galfenol as the active elements. Pulse-echo ultrasonic measurements of these transducers are made in-situ. This paper will present an overview of the test design including selection criteria for candidate materials and optimization of test assembly parameters, data obtained from both out-of-pile and in-pile testing at elevated temperatures, and an assessment based on initial data of the expected performance of ultrasonic devices in irradiation conditions

Reinhardt1, Brian↗

In situ investigation of high-pressure hydrogen-induced swelling in elastomers and its correlation with material properties

The resistance of elastomeric materials to high-pressure hydrogen-induced damage is essential for ensuring the reliability of hydrogen infrastructure. Here, in this study, we systematically investigated the swelling behavior and hydrogen transport properties of four elastomer types – EPDM, NBR, FKM, and HNBR – using a custom in-situ view cell system capable of real-time monitoring during decompression from pressures up to 96.5 MPa. Each elastomer was formulated with and without fillers and plasticizers to assess the effects of formulation on swelling response. Thermal desorption analysis (TDA) was employed to determine equilibrium hydrogen content and diffusion coefficients, providing insight into gas uptake and mobility within each material. Correlation analyses using Pearson and Spearman coefficients revealed that the diffusion coefficient showed a stronger relationship with swelling behavior than hydrogen content, highlighting the dominant role of hydrogen mobility. Filled elastomers, particularly those with carbon black, consistently showed reduced swelling due to enhanced stiffness and reduced diffusivity. These results deepen our understanding of diffuso-mechanical interactions in elastomers and support the rational design of sealing materials for high-pressure hydrogen systems.

EPDM↗

Autonomous monitoring of algal biomass: Success stories and lessons learned from long-term field deployment

Autonomous, high-frequency monitoring of outdoor algal ponds is needed to quantify biomass productivity and detect culture decline in environments prone to contamination, grazers, and variable operating conditions. We report successes and lessons learned in translating a laboratory spectroradiometric monitoring approach to a multi-year autonomous field deployment at the Arizona Center for Algae Technology and Innovation (AzCATI). The system measures spectrally resolved pond reflectance by ratioing upwelling radiance from each raceway to simultaneous downwelling sky irradiance using fiber-coupled spectrometers. A physics-based reflectance model (ASHARP) is fit to each spectrum pair to estimate optical parameters, including a biomass-proxy coefficient (C a ) which enables near-real-time tracking of biomass accumulation and culture state at 2–5 min intervals. From May 2022 through September 2025 the platform operated continuously while scaling from two to six raceway ponds. Several strains of algae were monitored successfully, including the high productivity Tetraselmis striata and Picochlorum celeri. Transitioning data acquisition from a Windows laptop to a Raspberry Pi improved uptime from 57% (2022) to ~89% (2024–2025) and enabled routine real-time analysis. Further, we converted relative biomass estimates to absolute ash-free dry weight (AFDW) using experimentally-derived calibrations, providing field-relevant biomass predictions with conservative confidence bounds. These results demonstrate the feasibility of long-term, autonomous optical monitoring for well-mixed open-raceway algal cultivation and provide practical guidance for reliable field operation and scaling.

Katinas, Christopher Michael [Sandia National Labo↗

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bayesian Gaussian process inference for neutron spin echo measurement

Neutron spin echo (NSE) spectroscopy provides unique access to microscopic dynamics, but its application is often constrained by low neutron flux, long acquisition times, and significant noise. Here, we present a Bayesian inference approach based on Gaussian process regression (GPR) to reconstruct high-quality spin echo signals from sparse and noisy data by exploiting correlations in reciprocal space. Benchmarks on synthetic datasets and validation with experimental NSE measurements of dendrimers show that GPR suppresses noise, interpolates missing intensity values, and accommodates irregular observations. The method improves accuracy, shortens acquisition times, and enables high-throughput and real-time studies. Beyond NSE, the framework is broadly applicable to other low signal-to-noise ratio scattering techniques, thereby extending the scope of neutron spectroscopy.

Tung, Chi-Huan [Oak Ridge National Laboratory (ORN↗

Quantum utility in simulating the real-time dynamics of the Fermi–Hubbard model using superconducting quantum computers

The Fermi–Hubbard model is a fundamental model in condensed matter physics that describes strongly correlated electrons. On the other hand, quantum computers are emerging as powerful tools for exploring the complex dynamics of these quantum many-body systems. In this work, we demonstrate the quantum simulation of the one-dimensional Fermi–Hubbard model using IBM's superconducting quantum computers, employing over 100 qubits. We introduce a first-order Trotterization scheme and extend it to an optimized second-order Trotterization for the time evolution in the Fermi–Hubbard model, specifically tailored for the limited qubit connectivity of quantum architectures, such as IBM's platforms. Notably, both Trotterization approaches are scalable and maintain a constant circuit depth at each Trotter step, regardless of the qubit count, enabling us to precisely investigate the relaxation dynamics in the Fermi–Hubbard model by measuring the expectation value of the Néel observable (staggered magnetization) for time-evolved quantum states. Lastly, our successful measurement of expectation values in such large-scale quantum many-body systems, especially at longer time scales with larger entanglement, highlights the quantum utility of superconducting quantum platforms over conventional classical approximation methods.

97 MATHEMATICS AND COMPUTING↗

Single-shot ultrafast dynamics of nanosecond pulsed plasmas: Transition from ps–ns nonequilibrium to near-full ionization

The ultrafast multi-stage evolution of state-defining properties in atmospheric-pressure nanosecond pulsed plasmas is quantified using single-discharge, jitter-free, continuous streak-sweep spectroscopy of N 2 (C → B) molecular and N + /O + ionic species with a single-shot time resolution as short as ∼160 ps. An early period of extreme nonequilibrium is observed with vibrational temperatures [T V (C)] dropping from ∼8000 K at <200 ps after plasma breakdown to <4000 K within ∼1 ns, with near-ambient rotational temperatures [T R (C)] ∼ 300 K due to limited collisional energy transfer. This early-time T V (C) trend is representative of a direct and unquenched look into the high-energy tail of the electron energy distribution function; thus, it tracks real-time changes in the mean electron energy via the N2(C) emission signatures. This is followed by the rapid onset of N + /O + ionic emission after a distinct time delay of ∼14.9 ns due to multistep chemical kinetics. The ionic emission enables determination of electron densities (n e ) >2 × 10 19 cm −3 and electron temperatures (T e ) >36 000 K, indicating the transition to a nearly fully ionized regime. The ps–ns temporal dynamics are also compared between air and N 2 plasmas to assess the influence of collisional partners, as well as across the anode, cathode, and central gap regions to identify spatial variations in plasma behavior. Finally, this work demonstrates versatile continuously probing approach capable of spectro-temporal and spatially resolved single-shot measurements of key state variables in the ps–ns evolution of atmospheric-pressure nanosecond pulsed plasmas.

Electric discharges↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Autoregressive long-horizon prediction of plasma edge dynamics *

Accurate modeling of scrape-off layer (SOL) and divertor-edge dynamics is vital for designing plasma-facing components in fusion devices. High-fidelity edge fluid/neutral codes such as SOLPS-ITER capture SOL physics with high accuracy, but their computational cost limits broad parameter scans and long transient studies. We present transformer-based, autoregressive surrogates for efficient prediction of 2D, time-dependent plasma edge state fields. Trained on SOLPS-ITER spatiotemporal data for the KSTAR tokamak, the surrogates forecast electron temperature, electron density, and radiated power over extended horizons. We evaluate model variants trained with increasing autoregressive horizons (1–100 steps) on short- and long-horizon prediction tasks. Longer-horizon training systematically improves rollout stability and mitigates error accumulation, enabling stable predictions over hundreds to thousands of steps and reproducing key dynamical features such as the motion of high-radiation regions. Measured end-to-end wall-clock times show the surrogate is orders of magnitude faster than SOLPS-ITER, enabling rapid parameter exploration. Prediction accuracy degrades when the surrogate enters physical regimes not represented in the training dataset, motivating future work on data enrichment and physics-informed constraints. Overall, this approach provides a fast, accurate surrogate for computationally intensive plasma edge simulations, supporting rapid scenario exploration, control-oriented studies, and progress toward real-time applications in fusion devices.

autoregressive deep learning↗

Strong-field Driven Sub-cycle Band Structure Modulation and Dephasing Control

In this work, we present measurements of ultrafast electric-field observables in magnesium oxide using a non-resonant nonlinear optical interaction. Using field observables, we show that strong laser fields modulate the band structure on sub-cycle timescales, thereby altering the material’s nonlinear optical response. We perform time-dependent perturbation theory calculations using a field-dependent dispersion relation and semiconductor Bloch equation calculations, both of which agree with experimental observations. Furthermore, we extract pulse decay times from the real-time signal electric field envelope and show sub-cycle control of dephasing times. Our work offers a new perspective on strong-field-driven electron dynamics in solids through electric-field observables. The demonstrated attosecond modulation of the nonlinear response could have important implications for quantum light generation and quantum spectroscopy using nonlinear optical processes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ML–Enabled FPGA Framework for Fast Quantum State Discrimination in Mid-Circuit Measurement Regimes

Accurate and low-latency quantum state discrimination is essential for protocols involving mid-circuit measurement (MCM) and conditional feed-forward. In superconducting quantum systems, conventional readout pipelines transfer measurement data to host processors for post-processing, introducing millisecond-scale delays that far exceed qubit coherence times. To overcome this bottleneck, we present an in-situ machine learning (ML) inference engine implemented on an FPGA for real-time quantum state discrimination. Our design performs inference directly on digitized readout signals with 40 ns latency, supports both qubit and qutrit readout, and enables conditional operations without host-side intervention. This capability is critical for MCM and for feedback-driven protocols such as quantum error correction. We validate the system on superconducting transmon hardware, demonstrating robust discrimination fidelity across multiple qubit and qutrit channels. We further demonstrate conditional qutrit logic driven by FPGA-resident classification, highlighting the potential of low-latency ML-on-FPGA control for NISQ applications and scalable fault-tolerant quantum computing.

Vora, Neel [Lawrence Berkeley National Laboratory ↗

Non-Invasive Electrode Impedance Estimation for Optimized Charge Profile Parameterization of Lithium-Ion Batteries

This work presents a non-invasive method for parameterizing a physically motivated equivalent circuit model of lithium-ion batteries using operando electrochemical impedance spectroscopy and time-domain data. The proposed model consists exclusively of linear circuit elements, enabling computationally efficient simulation and real-time implementation on battery management system chips. By integrating frequency- and time-domain measurements, the model accurately estimates internal states such as the negative electrode potential, achieving a root mean square error of 12.3 mV during fast charging validation. Parameterization requires only rate tests with sinusoidal perturbations at three different ambient temperatures, making the approach experimentally accessible. The model reveals key insights into battery behavior, including rate-dependent overpotentials primarily governed by charge transfer kinetics at the positive electrode, and temperature-dependent impedance contributions from both charge transfer and solid-state diffusion processes. Validation using reference electrodes confirms the model’s ability to detect lithium plating onset and reproduce impedance behavior across a wide range of operating conditions. The approach enables in situ optimization of fast charging profiles and lays the foundation for future extensions incorporating aging effects and plating dynamics.

25 ENERGY STORAGE↗

Development of an FGPA-Based Cavity Simulator for Testing RF Controls

LLRF is used to precisely control the amplitude and phase of the RF field in cavities. Often times, access to test the control algorithms with RF equipment, especially in the presence of beam, is limited or beyond reach. In such cases, testing must be done through computer modeling or simulations. Computer modeling is often too slow and difficult to interface with the LLRF hardware. Analog or digital cavity simulators are preferred as they allow for interaction with the LLRF controls platform in real-time, and compared to their analog counterparts, FPGA-based digital cavity simulators allow for a more adjustable and sophisticated implementation. The newly developed FPGA-based cavity simulator includes the cavity electrical model, the cavity mechanical model including Lorentz Force Detuning and microphonics, an amplifier model which can simulate real amplifier nonlinearities, and a beam model. The simulator has been validated using measurements from BNL’s CeC 704 MHz 5-cell SRF cryomodule.

43 PARTICLE ACCELERATORS↗

Ultrasonic Characterization of Lithium Ion Thermal Runaway Conditions for Real-time Ultrasonic Enabled BMS Integration

The demand for energy storage is growing, and lithium-ion batteries are a promising technology to meet this need due to their high power/energy density, high round-trip efficiency, rapid response time, and portability. However, recent catastrophic events caused by thermal runaway have slowed their adoption, highlighting the need for an early warning system for battery failure. In this work, ultrasound is used to detect physical changes in 950 mAh batteries by identifying material property changes independent of voltage and current. [Ultrasound signal features (e.g., time of flight, maximum frequency component) were extracted as the batteries were cycled and subjected to both constant current and constant voltage overcharge and were used to develop two metrics identifying failure: a warning to detect the start of overcharge and an emergency stop (E-stop) to immediately take the battery out of service. The identification method involved locating magnitude differences of several ultrasound features compared to baseline operation considering different currents and temperatures, and the warning/stopping metrics were consistent across all experiments. For an average overcharge time of 140 minutes, the average warning was issued 124 minutes before the failure and the average E-stop was triggered 94 minutes before failure. As a test of using ultrasound for early warning detection, a battery was forced into overcharge and returned to normal cycling conditions based on the previously determined warning metric. Both the voltage profile and the ultrasound measurements returned to their baseline behavior, indicating that ultrasonic detection can not only identify battery failure before a catastrophic event, but can also provide early enough warnings such that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.]

25 ENERGY STORAGE↗

Overview of IMPACT Data Acquisition System and Data Reduction Process

This report documents the development of the data acquisition system (DAS) and data reduction methodologies for the Irradiated Material Property Accelerated Characterization Test (IMPACT) experiment at the Advanced Test Reactor (ATR). The IMPACT experiment is designed to enable in-pile measurement of thermal conductivity in metallic nuclear fuels, specifically U-10Zr, using an instrumented thermal conductivity probe. The DAS supports both passive temperature monitoring and active thermal interrogation of the probe through controlled AC and DC excitation. Significant modifications to laboratory-scale systems were required to accommodate the higher resistance paths associated with the in-pile application. Custom electronics and relay-controlled measurement sequencing were developed to enable the measurement and sufficient power delivery to the sensing region. A reduced-order, axisymmetric thermal model based on the thermal quadrupoles method is presented to support data interpretation. This model enables efficient evaluation of transient heat transfer behavior and facilitates solution of the inverse problem required to extract thermal properties from measured signals. Multiple boundary condition formulations are discussed to address varying experimental time scales and geometries. Additionally, machine learning techniques are introduced to support data reduction and improve confidence in inverse solutions. Convolutional neural networks are applied to identify the presence of gas gaps and other evolving geometric features that significantly impact thermal response during irradiation. These efforts contribute to the broader integration of digital twin frameworks and real-time modeling capabilities within the Advanced Fuels Campaign.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗