Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ramp forecasting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

136 records · Page 8

Transactive Control and Coordination of Distributed Assets for Ancillary Services

The need to diversify energy supplies, the need to mitigate energy-related environmental impact, and the entry of electric vehicles in large numbers present challenges and opportunities to power system professionals. Wind and solar power provide many benefits, and to reap the benefits the resulting increased variability—forecasted as well as unforecasted—should be addressed. A majority of states and the District of Columbia, representing over half of the total load, have passed renewable portfolio standards. California’s plans call for 33% renewable energy by 2020. For grid balancing and for meeting reliability standards, ancillary services are needed. The needs for these services are poised to increase significantly. Demand resources are receiving increasing attention as one means of providing the ancillary services. Control and coordination of a large number (~millions) of distributed smart grid assets requires innovative approaches. One such approach is transactive control and coordination (TC2)—a distributed, hierarchical, agent-based incentive and control system. The TC2 paradigm is to create a market-like control system in which participation is voluntary and the participant sets the price for participation. For transactions that are frequent, automation of bids and responses is necessary. Such an approach has been developed and demonstrated at the Pacific Northwest National Laboratory. The devices, typically thermostatically controlled heating, ventilating, and air conditioning (HVAC) loads, send their bids—the quantity of energy they need and, based on the consumer preferences encoded in a simple user interface, the price they are willing to pay. The typical bid period is 5 minutes. By aggregating all the bids, a demand curve is generated by the aggregating entity, and matched with a supply curve or supply constraint. The aggregator transmits the clearing price to the devices. The winning devices proceed to consume the energy they bid for and won. It is the purpose of this project to develop a similar approach for ancillary services. In this report, the following ancillary services are considered: spinning reserve, ramping, and regulation. These services are to be provided by the following devices: refrigerators, water heaters, clothes dryers, variable speed drives. We will assume that the variable speed drives operate an air handling fan in a commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Guide for Improved Resource Adequacy Assessments in Evolving Power Systems: Institutional and Technical Dimensions

This paper identifies and evaluates issues in traditional resource adequacy (RA) assessment practices, and how adjusting these practices may affect and depend on existing institutional arrangements for planning and procurement. The paper proposes a technical-institutional roadmap that would allow regulators in vertically-integrated jurisdictions and system planners and operators in restructured jurisdictions to revise RA practices across a range of components. First, we compile a critical review of current RA assessment practices based on (1) interviews with RA practitioners and (2) a review of recent technical literature. We find that (i) RA may need to expand beyond capacity adequacy to ensure energy adequacy – relevant for energy-limited resources such as storage – and potentially some form of ancillary service adequacy (e.g. enough ramping-up and ramping-down capability in the system); (ii) chronological hourly simulations for all hours in the year are the current best practice; (iii) metrics and models used do not reflect economic criteria in system operation and loss of load; and (iv) there is a need to improve representation of weather dependencies and weather data. Second, we review planning and RA reports for several private and public entities that plan generation and/or transmission infrastructure in the continental U.S. to look for existing practices involving resilience assessments. We find no systematic treatment of the costs of extreme weather and other hazards, the benefits of resilience, and resilience metrics in planning analyses and no systematic treatment of resilience metrics, methods, and outcomes for resource adequacy purposes. Third, we create a technical framework for probabilistic RA assessment and use it to study how key choices about how to model power system operations affect the values that are obtained for RA metrics. We find that (i) non-economic dispatch schemes that ignore economic objectives can lead to accurate RA assessments when coordinated with detailed operational strategies; (ii) multi-year data is critical to capture a wide variety of system conditions; (iii) not incorporating transmission limits into RA assessment could lead to substantial underestimation of traditional “expected value” RA metrics; and (iv) new RA metrics that capture event-specific shortfall characteristics should be used as supplements to traditional metrics. Finally, we examine RA assessments and use this information to propose a guide of evolving industry standards for resource adequacy assessments in resource planning and transmission planning. We report minimum, best, and frontier practices for temporal resolution of assessments, metrics and targets, weather data, load forecasting, characterization of variable renewable resources, characterization of transmission and market transactions, RA modeling and integration with planning processes, and capacity accreditation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Regime Characterization of Offshore Wind Resource Using Unsupervised Learning

Predictability of wind resource conditions is critical for offshore wind design and operations. While many studies of extreme wind conditions focus on specific events such as low-level jets or ramps, these rely on threshold definitions that limit generality. Here we present a data-driven framework that combines principal component analysis (PCA), self-organizing maps (SOM), and k-means clustering to classify wind resource conditions as typical and anomalous from climatological data. Anomalies are defined not by fixed thresholds but by flagging samples located far from SOM node centers inside the baseline SOM structure. This reframes extremes as rare ebents and hence, likely difficult to anticipate by numerical weather prediction models. We applied this approach to 23 years (2000–2022) of hourly profiles from the NOW-23 hindcast model at the Humboldt Wind Energy Area. Classification is conducted on a feature space consisting of 10 m wind speed and direction, bulk shear and veer across 30–270 m, and a low-level jet index. Dimensionality reduction is achieved through PC. A 2 × 3 OM lattice trained on the PCA vectors identified six baseline regimes spanning weak to strong flow states. High quantization-error profiles are identified and re-clustered into four anomalous regimes. The baseline regimes exhibited clear seasonal and diurnal cycles. Meanwhile, the anomalous regimes represented <10 % of all hours but showed distinct combinations of speed, shear, and veer, when compared to the baseline regimes. Anomalous regimes are typically short-lived (~few hours), yet their transitions can lead to hub-height wind changes of −18 to +9 m s -1 . For a representative 15 MW turbine, these shifts imply rapid swings in capacity factor from near-full output to negligible generation. Validation with lidar buoy data showed 51% agreement in SOM labels across ~6,000 overlapping hours, with most mismatches confined to adjacent speed classes. HRRR comparisons further revealed that anomalous regimes were disproportionately associated with forecast biases exceeding 5 m s -1 . Together, these results reframe extremes in offshore wind from absolute maxima or minima to weather states that are difficult to anticipate from models.

17 WIND ENERGY↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Radiation Induced Corrosion of Copper in Deep Geological Repositories - 19493

This paper presents an overview of the Cu corrosion research being conducted by the Radiation Assisted Materials Performance Science (RAMPS) group at Western University, in collaboration with the Canadian Nuclear Waste Management Organization (NWMO) and Canada Natural Science and Engineering Research Council (NSERC). This paper presents an overview of our research in three areas to develop a high-fidelity copper corrosion model. Copper is an important candidate material for corrosion protection of used nuclear fuel containers (UFC). The UFC and its environment will be exposed to a continuous flux of γ-radiation. The three areas are chemical kinetics of γ-radiolysis of humid air and groundwater, the effects of solution parameters on Cu corrosion dynamics without γ-radiation and the effects of γ-radiation on Cu corrosion dynamics. These studies show that because of the strong feedback loops between processes occurring during copper corrosion, the overall corrosion mechanism may not follow linear dynamics. Presented here are our key findings, their implications for corrosion science in general, and the potential implications of these results for predictions of the adequacy of a UFC copper corrosion allowance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

What Sets the Massive Star Formation Rates and Efficiencies of Giant Molecular Clouds?

Galactic star formation scaling relations show increased scatter from kpc to sub-kpc scales. Investigating this scatter may hold important clues to how the star formation process evolves in time and space. Here, we combine different molecular gas tracers, different star formation indicators probing distinct populations of massive stars, and knowledge of the evolutionary state of each star-forming region to derive the star formation properties of ∼150 star-forming complexes over the face of the Large Magellanic Cloud (LMC). We find that the rate of massive star formation ramps up when stellar clusters emerge and boost the formation of subsequent generations of massive stars. In addition, we reveal that the star formation efficiency of individual giant molecular clouds (GMCs) declines with increasing cloud gas mass (M{sub cloud}). This trend persists in Galactic star-forming regions and implies higher molecular gas depletion times for larger GMCs. We compare the star formation efficiency per freefall time (ϵ{sub ff}) with predictions from various widely used analytical star formation models. While these models can produce large dispersions in ϵ{sub ff} similar to those in observations, the origin of the model-predicted scatter is inconsistent with observations. Moreover, all models fail to reproduce the observed decline of ϵ{sub ff} with increasing M{sub cloud} in the LMC and the Milky Way. We conclude that analytical star formation models idealizing global turbulence levels and cloud densities and assuming a stationary star formation rate (SFR) are inconsistent with observations from modern data sets tracing massive star formation on individual cloud scales. Instead, we reiterate the importance of local stellar feedback in shaping the properties of GMCs and setting their massive SFR.

79 ASTRONOMY AND ASTROPHYSICS↗

A trait-based framework for linking microbial communities with carbon transformations under precipitation change

Droughts are common throughout the world. As the climate changes, droughts may become more frequent and intense. Still, scientists are uncertain about how drought will affect the natural world, particularly the bacteria, fungi, and other microbes that live in soils. These tiny life forms are crucial because they control the Earth’s flows of carbon and essential nutrients. Researchers at the University of California, Irvine, and Lawrence Berkeley National Laboratory teamed up to study how the microbiome, or collection of bacteria and fungi in the soil, deals with drought. Since 2007, the researchers have used shelters with retractable roofs to prevent nearly half of normal rainfall from reaching grass and shrub ecosystems, and their soil microbiomes, in Southern California. The study team discovered that microbes have some clever tricks up their sleeve for surviving drought. When growing on dead grass as a food source, microbes ramp up production of specialized chemicals called osmolytes that keep their cells from drying out. But microbes growing on dead shrubs face another problem. Unlike grass, shrub leaves are a lousy food source. To digest and consume shrub leaves, microbes have to exude more enzymes, which act like biochemical chef knives that chop complex leaf molecules into bite-sized pieces. Carbon is the coin of the microbial realm, earned via enzyme action or slurping up dead plant juices. Microbes growing under normal conditions on tasty dead grass have it easy: they can spend most of their carbon currency on growth. With drought, life gets harder as microbes need to pay up for osmolytes and ramp down their growth. It gets worse with shrub leaves because microbes have to multi-task among growth, enzyme secretion, and osmolyte production. When drought hits, microbes on shrub leaves forgo the osmolytes, probably because losing the carbon revenue from enzyme investment would be a deal-breaker for survival. The next question tackled by the researchers asked how the genes controlling microbial lifestyles sort out across the tree of life. Most microbiologists thought these lifestyles would correspond to rather large branches on the tree. But the study team found that in fact, very closely related microbes differ in important and interesting ways. For example, bacteria that have nearly identical housekeeping genes respond distinctively to warming, rainfall, and plant chemistry. As a result, soil microbiomes are much richer in diversity than originally thought. And studying microbial diversity in much greater detail could open up many more possibilities for how microbial life deals with changing environmental conditions. Trying to understand microbial life without the fine details of genetic diversity is like trying to stream Netflix on a dial-up connection. By looking across the landscape, the researchers revealed that microbial diversity is absolutely critical for maintaining the planet’s flows of carbon and nutrients. The study team designed a new technology—microbial cages—for transplanting intact microbiomes. With the cages, the researchers could move microbiomes to novel environments and compare their ability to cycle carbon and nutrients. In some cases, performance tailed off when microbiomes found themselves in a new environment, but in other cases, performance rivaled or even exceeded that of the resident microbiome. And even the low performers eventually caught up to the native microbiomes if given sufficient time. These findings mean that microbiomes—at least in Southern California—may be resilient to climate shifts due to a high diversity of microbial lifestyles. Coping with heat and drought may literally be in their DNA. The last piece of the research puzzle, and a “Holy Grail” for microbial ecologists, is to forecast the behavior of diverse microbiomes. To meet this challenge, the study team developed new theory and computer models. For the first time, these models account for hundreds of different microbes and how their intricate lifestyles cope with drought. The models are starting to connect the tiniest microbes with the global cycles that sustain Earth’s farms, fields, and forests. With that connection, it will be easier for society to plan for a world with more droughts and other climate disruptions.

54 ENVIRONMENTAL SCIENCES↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Corrosion of Carbon Steel Inside Used Nuclear Fuel Containers - 19492

This paper presents an overview of the carbon steel (CS) corrosion research being conducted by the Radiation Assisted Materials Performance Science (RAMPS) group at Western University, in collaboration with the Canadian Nuclear Waste Management Organization (NWMO) and Canada Natural Science and Engineering Research Council (NSERC). The objective of our studies is to develop a high-fidelity CS corrosion dynamic model that can be used to assess the integrity of the current Canadian used fuel container (UFC) design with confidence. Our key findings, the implications of the findings on corrosion science in general, and the potential consequences of these results on the predictions for long-term UFC integrity are described. Results are presented on the following five themes: chemical kinetics of γ-radiolysis of liquid water and humid air, aqueous corrosion of CS under γ-radiation, corrosion of CS under small water volumes and water filled gaps, Liesegang ring formation in a gel medium, and radiation-induced iron oxide nanoparticle formation from dissolved metal ions. These studies together represent a detailed and integrated examination of the whole CS corrosion system, and in particular, its behaviour under γ-radiation. The key finding of this research is that under certain conditions, the CS corrosion system can exhibit non-linear dynamic behaviours - which can be seen in periodic precipitation patterns and oscillations in measurable system properties such as corrosion potential. This throws into question existing corrosion models that do not account for these types of behaviours. We describe the preliminary steps we have taken in integrating these new understandings into a CS corrosion dynamic model that will be able to make long-term predictions of CS corrosion in the UFC environment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗