At least 145 records · Page 8

Iodine effective diffusion coefficients through volcanic rock: Influence of iodine speciation and rock geochemistry

Accurate prediction of the subsurface transport of iodine species is important for the assessment of long-term nuclear waste repository performance, as well as monitoring compliance with the Comprehensive Nuclear-Test-Ban Treaty, given that radioiodine decays into radioxenon. However, the transport of iodine through intact geologic media is not well understood, compromising our ability to assess risk associated with radioiodine migration. The current study's goal is to quantify the matrix diffusion of iodine species through saturated volcanic rock, with particular attention paid to the redox environment and potential speciation changes. Here, diffusion experiments were run for iodide through lithophysae-rich lava, lithophysae-poor lava, and welded tuff, whereas iodate diffusion was studied through welded tuff. Iodine transport was compared with a conservative tracer, HDO, and effective diffusion coefficients were calculated. Likely due to a combination of size and anion exclusion effects, iodine species diffused more slowly than the conservative tracer through all rock types tested. Furthermore, oxidation of iodide to iodate was observed in the lithophysae-poor lava, affecting transport. Results provide much needed data for subsurface transport models that predict radioiodine migration from underground sources, and indicate the pressing need for geochemical and redox interactions to be incorporated into these models.

58 GEOSCIENCES↗

Xenon adsorption on geological media and implications for radionuclide signatures

Here, the detection of radioactive noble gases is a primary technology for verifying compliance with the pending Comprehensive Nuclear-Test-Ban Treaty. A fundamental challenge in applying this technology for detecting underground nuclear explosions is estimating the timing and magnitude of the radionuclide signatures. While the primary mechanism for transport is advective transport, either through barometric pumping or thermally driven advection, diffusive transport in the surrounding matrix also plays a secondary role. From the study of primordial noble gas signatures, it is known that xenon has a strong physical adsorption affinity in shale formations. Given the unselective nature of physical adsorption, isotherm measurements reported here show that non-trivial amounts of xenon adsorb on a variety of media, in addition to shale. A dual-porosity model is then discussed demonstrating that sorption amplifies the diffusive uptake of an adsorbing matrix from a fracture. This effect may reduce the radioxenon signature down to approximately one-tenth, similar to primordial xenon isotopic signatures.

58 GEOSCIENCES↗

Comparison of near-background concentrations of Argon-37 and Xenon-133 in the Atmosphere

Radioisotopes of noble gases xenon and argon can be important indicators of underground nuclear explosions. The Comprehensive Nuclear-Test-Ban Treaty (CTBT) includes monitoring capabilities to identify potential nuclear explosions conducted in violation of the CTBT. This monitoring currently focuses on measurement of the xenon isotopes 133Xe, 135Xe, 131mXe and 133mXe. However, it is predicted that within 100 days of an underground nuclear explosion (UNE) 37Ar would be released to the atmosphere at higher concentrations than xenon isotopes (Haas et al. 2010) and with a higher signal to background ratio, depending on the radioxenon background levels. Therefore, inclusion of 37Ar measurement capabilities at atmospheric International Monitoring System (IMS) stations may represent an improvement in the capability to detect a nuclear explosion. At an IMS station, it could be difficult to determine what constitutes an elevated concentration as a result of an UNE without first understanding the expected range of background concentrations. This work describes our analysis of atmospheric samples for 37Ar to evaluate the range of background concentrations. Samples were collected at multiple locations, with approximately half coming from a sampler co-located with an IMS xenon monitoring station (RN75). The range of 37Ar concentrations measured in atmospheric air samples was relatively narrow; for samples considered detectable, the minimum and maximum measured concentrations were 0.56 and 2.3 mBq/m3, respectively. Comparison of 37Ar and 133Xe concentrations measured at the IMS station indicated some correlation between the measured concentrations. The results presented here demonstrate the capability to detect background concentrations of 37Ar in atmospheric air and provide a basis for potential implementation of 37Ar monitoring at IMS stations.

Fritz, Brad G.↗

Projected network performance for multiple isotopes using next-generation xenon monitoring systems

Since about 2000 (Bowyer et al., 1998), radioxenon monitoring systems have been under development and testing for the verification of the Comprehensive Nuclear Test-Ban Treaty (CTBT). Operation of the systems since then has resulted in development of a next-generation of systems that are nearly ready for operational deployment. By 2010, the need to screen out civilian sources was well known (Auer et al., 2010; Saey, 2009), and isotopic ratio approaches were soon considered (Kalinowski et al., 2014) to identify specific sources. New generation systems are expected to improve the ability to verify the absence of nuclear tests by using isotopic ratios when multiple isotopes are detected. In this work, thousands of releases were simulated to compute the global detection probability of 131m Xe, 133m Xe, 133 Xe, and 135 Xe at 39 noble gas systems in the International Monitoring System (IMS) for both current and next-generation systems. Three release scenarios are defined at 1 h, 1 d, and 10 d past a 1 kt TNT equivalent 235U explosion event. Multiple cases using from one part in a million to the complete release of the xenon isotopic activity are evaluated for each scenario. Coverage maps and global integrals comparing current and next-generation monitoring systems are presented showing that next-generation noble gas systems will create measurable improvements in the IMS. The global detection probability for 133 Xe is shown to be strong in all scenarios, but only modestly improved by next-generation equipment. However, the detection probability for 131m Xe and 133m Xe increased to about 50% in different scenarios, providing a second detectable isotope for many events. As anticipated from shorter sampling intervals, the expected number of detecting samples roughly doubled and the expected number of detecting stations rose by approximately 50% for all release scenarios. Thus, it might be anticipated that future events would consist of multiple 133 Xe detections and one or more second isotope detections. In conclusion, signals of this nature should increase detection confidence, tighten release location estimates, improve rejection of civilian signals, and lessen the impacts from individual systems being offline for maintenance or repair reasons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Projected network performance for next-generation xenon monitoring systems

Next-generation radioxenon monitoring systems are reaching maturity and are expected to improve certain aspects of performance in verifying the absence of nuclear tests. To predict the improvement in detecting and locating nuclear releases, thousands of releases all over the globe were simulated and the global detection probability was calculated. This was done for the International Monitoring System network of noble gas samplers as it currently exists (25 certified stations), and how it would be for potential future network sizes of 39 and 79 stations. The probability of detection was calculated for releases ranging from 10 10 Bq to 10 16 Bq of 133 Xe and presented as coverage maps and global integrals for both current and next-generation monitoring systems. Similarly, the number of detecting stations and the number of detecting samples were tabulated to elucidate the possibilities for enhanced location capability. Improvements in global detection coverage are maximized at different release sizes in a way that depends on the station density. For example, for releases of 3×10 14 Bq and 39 stations, the detection probability would rise from 60% to 70% with next-generation systems, while for releases of 10 13 Bq and 79 stations, it would rise from 37% to 52%. Achieving an average of two detecting stations requires a 1015 Bq release for a 39-station network and a 10 14 Bq release for a 79-station network. The largest impact of using next-generation systems may be the confidence, failure tolerance, and location capability that arise from obtaining multiple samples associated with a single release event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preferential adsorption of noble gases in zeolitic tuff with variable saturation: A modeling study of counter-intuitive diffusive-adsorptive behavior

Noble gas transport through geologic media has important applications in the prediction and characterization of measured gas signatures related to underground nuclear explosions (UNEs). Retarding processes such as adsorption can cause significant species fractionation of radionuclide gases, which has implications for measured and predicted signatures used to distinguish radioxenon originating from civilian nuclear facilities or from UNEs. Accounting for the effects of variable water saturation in geologic media on tracer transport is one of the most challenging aspects of modeling gas transport because there is no unifying relationship for the associated tortuosity changes between different rock types, and reactive transport processes such as adsorption that are affected by the presence of water likewise behave differently between gas species. In this study, we perform numerical diffusive-adsorptive transport simulations to estimate gas transport parameters associated with bench-scale laboratory diffusion cell experiments measuring breakthrough in zeolitic and non-zeolitic rocks for a gaseous mixture of xenon, krypton, and SF 6 at varying degrees of water saturation (S w ). Counter-intuitive transport behavior was observed in the zeolitic rock experiments whereby breakthrough concentrations were significantly higher when the core was partially saturated (S w = 17 %) than under dry (S w = 0 %) conditions. Breakthrough of xenon was especially retarded in the dry core – likely due to comparatively high affinity of xenon for zeolitic adsorption sites – and estimated effective diffusion coefficients for all gases were approximately an order of magnitude lower than what is predicted by porosity-tortuosity models. We propose the counter-intuitive behavior observed is because water infiltration of zeolite nanopores reduces both the adsorptive capacity of the rock and the tortuosity of connected flow paths. We developed a two-site competitive kinetic Langmuir adsorption reaction for the porous media transport simulator in order to constrain transport parameters within zeolitic tuff, where differential adsorption to zeolite and non-zeolite pores was observed. We determined that liquid saturation-dependent diffusive-adsorptive transport is affected by subtle and at times competing processes that are specific to different gases, which have a significant overall influence on effective transport parameters.

58 GEOSCIENCES↗

A statistical approach to screening isotopic signatures in monitoring for underground nuclear explosions

The ability to differentiate between atmospheric radionuclide signatures from underground nuclear explosions (UNEs) and signals from other sources, such as medical isotope-production facilities and nuclear reactors, can be critical to the detection and monitoring of unannounced, low-yield nuclear events. Signatures having anomalously high amplitudes, compared to background levels, remain the best indicator in screening for a UNE. However, isotopic composition can further validate a suspected UNE signature, but separation from any atmospheric background composition is first necessary. To date, evaluating the challenges of performing this separation has typically involved comparing an observed background with a highly idealized deterministic model of radioxenon signature production by a UNE that does not consider the influence of post-detonation chemical/physical processes in the detonation cavity or the subsequent gas transport mechanisms that can also affect the isotopic composition of the detected gas signature. In addition, purely deterministic models, as previously employed, overlook the uncertainty inherent in estimating critical parameters characterizing the UNE and its detonation environment. In this paper, we create detailed, multi-parameter models of radionuclide evolution using the widely accepted England and Rider post-detonation radionuclide decay-chain network coupled to detailed models simulating physical production and transport processes affecting the gas signature. Because these models are governed by uncertain parameters including barometric fluctuations, realistic ranges of variation for each of the parameters influencing isotopic composition are then defined. A Latin-Hypercube sampling approach is used to obtain a random distribution of isotopic production and gas transport results associated with a given value of each parameter. We apply these results to background histories of two stations, one providing 4-isotope background measurements and the other providing two-isotope measurements associated with the 2013 DPRK announced UNE.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Gas transport across the low-permeability containment zone of an underground nuclear explosion

Understanding the nature of gas transport from an underground nuclear explosion (UNE) is required for evaluating the ability to detect and interpret either on-site or atmospheric signatures of noble gas radionuclides resulting from the event. We performed a pressure and chemical tracer monitoring experiment at the site of an underground nuclear test that occurred in a tunnel in Nevada to evaluate the possible modes of gas transport to the surface. The site represents a very well-contained, low gaspermeability end member for past UNEs at the Nevada National Security Site. However, there is very strong evidence that gases detected at the surface during a period of low atmospheric pressure resulted from fractures of extremely small aperture that are essentially invisible. Our analyses also suggest that gases would have easily migrated to the top of the high-permeability collapse zone following the detonation minimizing the final distance required for migration along these narrow fractures to the surface. This indicates that on-site detection of gases emanating from such low-permeability sites is feasible while standoff detection of atmospheric plumes may also be possible at local distances for sufficiently high fracture densities. Finally, our results show that gas leakage into the atmosphere also occurred directly from the tunnel portal and should be monitored in future tunnel gas sampling experiments for the purpose of better understanding relative contributions to detection of radioxenon releases via both fracture network and tunnel transport.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Xenon International Automated Control

The Xenon International Automated Control software monitors, displays status, and allows for manual operator control as well as fully automatic control of multiple commercial and PNNL designed hardware components to generate and transmit atmospheric radioxenon concentration measurements every six hours.

Source record↗

Requirements for Xenon International

This document defines the requirements for the new Xenon International radioxenon system. The output of this project will be a Pacific Northwest National Laboratory (PNNL) developed prototype and a manufacturer-developed production prototype. The two prototypes are intended to be as close to matching as possible; this will be facilitated by overlapping development cycles and open communication between PNNL and the manufacturer.

Hayes, James C.↗

Requirements for Xenon International

This document defines the requirements for the new Xenon International radioxenon system. The output of this project will be a Pacific Northwest National Laboratory (PNNL) developed prototype and a manufacturer-developed production prototype. The two prototypes are intended to be as close to matching as possible; this will be facilitated by overlapping development cycles and open communication between PNNL and the manufacturer.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Evaluation and Uncertainty of a New Method to Detect Suspected Nuclear and WMD Activity: Project Report

The Atmospheric Technology Group at SRNL developed a new method to detect signals from Weapons of Mass Destruction (WMD) activities in a time series of chemical measurements at a downwind location. This method was tested with radioxenon measured in Russia and Japan after the 2013 underground test in North Korea. This LDRD calculated the uncertainty in the method with the measured data and also for a case with the signal reduced to 1/10 its measured value. The research showed that the uncertainty in the calculated probability of origin from the NK test site was small enough to confirm the test. The method was also wellbehaved for small signal strengths.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Subsurface Noble Gas Sampling Manual

The intent of this document is to provide information about best available approaches for performing subsurface soil gas sampling during an On Site Inspection or OSI. This information is based on field sampling experiments, computer simulations and data from the NA-22 Noble Gas Signature Experiment Test Bed at the Nevada Nuclear Security Site (NNSS). The approaches should optimize the gas concentration from the subsurface cavity or chimney regime while simultaneously minimizing the potential for atmospheric radioxenon and near-surface Argon-37 contamination. Where possible, we quantitatively assess differences in sampling practices for the same sets of environmental conditions. We recognize that all sampling scenarios cannot be addressed. However, if this document helps to inform the intuition of the reader about addressing the challenges resulting from the inevitable deviations from the scenario assumed here, it will have achieved its goal.

58 GEOSCIENCES↗

Conceptual Silicon Beta Cell Design

Silicon detectors have the potential to significantly improve the sensitivity limits for radioxenon detection. While silicon has beneficial attributes like improved energy resolution and memory effect, the sensitivity improvements will not occur without a properly designed beta cell that utilizes silicon detectors. This report details the key parameters that have been incorporated into the design of a silicon beta cell. Parameters that have the potential to change as a prototype silicon beta cell is developed and during the future commercialization process are also discussed. The design of the silicon beta cell has focused primarily on simulations and analytical models to optimize the mechanical properties. Additionally, a team of experts provided guidance and potential alternatives for the silicon detectors and electronics fabrication. A conceptual design for a silicon beta cell was completed, with an emphasis on the modularity of the system. The modularity allows for any potential changes that may be of interest during the prototyping phase or future spiral development to be implemented with minimal impact on the complete system. The impact of the silicon based beta cell is discussed in the conclusions, along with potential next steps. Mechanical design drawings for the beta cell could be used to manufacture a prototype beta cell and are available in an appendix document.

36 MATERIALS SCIENCE↗

Xenon International Overview

The Xenon International system is a fully automated unattended system designed to collect, separate, purify, quantify, and perform nuclear counting on radioxenon isotopes as well as transmit data using two-way communications (Figure 1). Xenon International is designed to stringent requirements that make it an high performance next-generation-system for use in nuclear explosion monitoring networks such as the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Minimum Detectable Concentration and Concentration Calculations

This report highlights the work that has been completed on concentration calculations, uncertainties and minimum detectable concentration (MDC) for radioxenon collection systems. A discussion on the theory behind MDC calculations is given. In addition, regions of interest (ROI) and their role in correcting for both memory effects and interference terms are given in detail. A detailed derivation and walkthrough of the calculation is given with some discussion at each stage of the equation. Finally, some specific examples are given with typical numbers from an ARSA system as a guide.

61 RADIATION PROTECTION AND DOSIMETRY↗

Requirements for Xenon International (Rev. 2)

This document defines the requirements for the new Xenon International radioxenon system. The output of this project will be a Pacific Northwest National Laboratory (PNNL) developed prototype and a manufacturer-developed production prototype. The two prototypes are intended to be as close to matching as possible; this will be facilitated by overlapping development cycles and open communication between PNNL and the manufacturer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Xenon Abatement Simulations to Support the KAERI Medical Isotope Facility

To maintain and improve the verification regime that is outlined by the Preparatory Commission of the Comprehensive Nuclear Test-Ban Treaty there is a need to understand and reduce the radioxenon releases from medical isotope production facilities. In support of this objective Pacific Northwest National Laboratory (PNNL) was tasked with, modeling and evaluate the abatement process and delay bed designs for the medical isotope production facility under construction by the Korea Atomic Energy Research Institute (KAERI). This report includes this analysis and provides PNNL proposed modifications to the KAERI adsorption bed design.

07 ISOTOPE AND RADIATION SOURCES↗