The Aquarius ocean salinity mission high stability L-band radiometer

The NASA Earth Science System Pathfinder (ESSP) mission Aquarius, will measure global ocean surface salinity with ~120 km spatial resolution every 7-days with an average monthly salinity accuracy of 0.2 psu (parts per thousand) [1]. This requires an L-band low-noise radiometer with the long-term calibration stability of ≤0.15 K over 7 days. The instrument utilizes a push-broom configuration which makes it impractical to use a traditional warm load and cold plate in front of the feedhorns. Therefore, to achieve the necessary performance Aquarius utilizes a Dicke radiometer with noise injection to perform a warm – hot calibration. The radiometer sequence between antenna, Dicke load, and noise diode has been optimized to maximize antenna observations and therefore minimize NEDT. This is possible due the ability to thermally control the radiometer electronics and front-end components to 0.1 °Crms over 7 days.

Freedman, Adam↗

Lessons Learned from SMAP Radiometer Pre-/Post-launch Calibration

The Soil Moisture Active Passive(SMAP) mission was launched on 31stJanuary 2015 in a 6 AM/ 6 PM sun-synchronous orbit at 685 km altitude to measure soil moisture and free/thaw globally [1]. The passive instrument of SMAP is a fully polarimetric L-band radiometer (1.4GHz) operating with a bandwidth of 24MHz. The radiometer uses a combination of noise-diodes and Dicke-loads for internal calibration with a design similar to that used by the Aquarius or Jason series radiometers[2,3].Pre-launch calibration activities had been performed since 2012on the engineering model of the radiometer. Post-launch calibration activities have been performed to fine-tune and validate the results from the pre-launch calibration. The major calibration activities and lessons learned in the past 8 years will be described in the following sections.

Jinzheng Peng↗

Observing Ice Phase Clouds and Precipitation with Millimeter- and Submillimeter-wave Radiometry during the IMPACTS field campaign: Algorithm Development for the Emerging Class of Microwave Radiometers

Millimeter- and submillimeter-wave (mmWave, submm) radiometers provide significant information content on atmospheric water in liquid, ice, and vapor phases. Recent sensors, such as the Global Precipitation Measurement (GPM) or the Temporal Experiment for Storms and Tropical Systems Technology – Demonstration (TEMPEST-D), use mmWave bands to improve estimation of ice-phase precipitation, and future missions, such as the Atmosphere Observing System (AOS), will extend to submm to provide additional information on thinner ice clouds, linking clouds and precipitation and therefore elucidating the links between weather, climate, and the water cycle. To support the expanded use of mmWave/submm radiometry and exploit the available information content on condensed water mass, we demonstrate ice and liquid water path retrievals for NASA Goddard Space Flight Center's airborne radiometers the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) and the Configurable Scanning Submillimeter-wave Instrument/Radiometer (CoSSIR, formerly the Compact Scanning Submillimeter Imaging Radiometer). The analysis is based on data collected during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS) field campaign. A simulation study compares and contrasts retrievals for CoSMIR and CoSSIR, with CoSSIR demonstrating higher skill in ice retrievals, particularly for thin clouds, and the CoSMIR frequencies performing better for liquid. Additionally, we look at dual-polarized radiances observed by CoSMIR during the first two IMPACTS deployments to understand the polarization signatures induced by oriented hydrometeors. Results will be presented in the context of upcoming missions and sensors including AOS and the Ice Cloud Imager (ICI). We will describe the objectives for the expected first flight of the newly upgraded CoSSIR during the final IMPACTS deployment, and we will share novel science investigations we plan to undertake with CoSSIR's new capabilities. Popular Summary: Ice in clouds and falling snow is an important component of weather, climate, and water resources. To better use a new class of sensors that provide information on atmospheric ice, we developed an approach to measure ice clouds and falling snow using airborne data taken during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS), a field campaign to study winter storms. We look at the results for two similar instruments to understand how those differences affect these measurements of clouds and snow, and we further investigate the information the sensors can provide on properties of the clouds and snow.

Ian S Adams↗

Using DSCOVR EPIC as a Transfer Radiometer to Scale Multiple VIIRS Sensors Over Tropical Earth Views

The NASA CERES project provides Energy Balanced and Filled (EBAF) product climate-quality observed TOA and computed surface fluxes to the climate community. The CERES instruments are on board the Terra, Aqua, Suomi-NPP, and NOAA-20 satellites. The CERES project radiometrically scales the MODIS and VIIRS imager visible channel radiances to the Aqua- MODIS reference to retrieve consistent imager cloud properties between sensors, which are used to retrieve cloud properties required for converting CERES radiance observations into fluxes. The NPP, NOAA-20, and the future NOAA-21 VIIRS imagers will be in the same sun- synchronous orbit but spaced equally apart, which means that no simultaneous nadir overpasses (SNO) may be used to inter-calibrate the VIIRS imagers to each one another. Currently, the CERES project uses Aqua-MODIS to radiometrically scale between VIIRS imagers. Once the Terra and Aqua satellites start drifting toward the terminator, Aqua-MODIS can no longer be utilized as the transfer radiometer between VIIRS sensors and there will be no SNOs in common between either MODIS and or VIIRS imagers. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth. The Earth Polychromatic Imaging Camera (EPIC) instrument on the Earth-facing side of DSCOVR takes images ranging from the UV to the NIR of the sunlit side of the Earth. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that the EPIC instrument response is radiometrically stable. The stability of the EPIC instrument allows it to be used as a transfer radiometer between all MODIS and VIIRS imagers and is especially suited for drifting orbits because EPIC imager frequently samples the Earth diurnally. The study will demonstrate the use of EPIC as a transfer radiometer to radiometrically scale the NPP and NOAA-20 VIIRS imagers. The scaling factors will be compared with the scaling factors using Aqua-MODIS as the transfer radiometer.

Conor Haney↗

Observing Ice Phase Clouds and Precipitation with Millimeter- and Submillimeter-wave Radiometry during the IMPACTS field campaign: Algorithm Development for the Emerging Class of Microwave Radiometers

Millimeter- and submillimeter-wave (mmWave, submm) radiometers provide significant information content on atmospheric water in liquid, ice, and vapor phases. Recent sensors, such as the Global Precipitation Measurement (GPM) or the Temporal Experiment for Storms and Tropical Systems Technology – Demonstration (TEMPEST-D), use mmWave bands to improve estimation of ice-phase precipitation, and future missions, such as the Atmosphere Observing System (AOS), will extend to submm to provide additional information on thinner ice clouds, linking clouds and precipitation and therefore elucidating the links between weather, climate, and the water cycle. To support the expanded use of mmWave/submm radiometry and exploit the available information content on condensed water mass, we demonstrate ice and liquid water path retrievals for NASA Goddard Space Flight Center's airborne radiometers the Conical Scanning Millimeter-wave Imaging Radiometer (CoSMIR) and the Configurable Scanning Submillimeter-wave Instrument/Radiometer (CoSSIR, formerly the Compact Scanning Submillimeter Imaging Radiometer). The analysis is based on data collected during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS) field campaign. A simulation study compares and contrasts retrievals for CoSMIR and CoSSIR, with CoSSIR demonstrating higher skill in ice retrievals, particularly for thin clouds, and the CoSMIR frequencies performing better for liquid. Additionally, we look at dual-polarized radiances observed by CoSMIR during the first two IMPACTS deployments to understand the polarization signatures induced by oriented hydrometeors. Results will be presented in the context of upcoming missions and sensors including AOS and the Ice Cloud Imager (ICI). We will describe the objectives for the expected first flight of the newly upgraded CoSSIR during the final IMPACTS deployment, and we will share novel science investigations we plan to undertake with CoSSIR's new capabilities. Popular Summary: Ice in clouds and falling snow is an important component of weather, climate, and water resources. To better use a new class of sensors that provide information on atmospheric ice, we developed an approach to measure ice clouds and falling snow using airborne data taken during the Investigation of Microphysics and Precipitation for Atlantic Coast-Threatening Storms (IMPACTS), a field campaign to study winter storms. We look at the results for two similar instruments to understand how those differences affect these measurements of clouds and snow, and we further investigate the information the sensors can provide on properties of the clouds and snow.

Ian S Adams↗

Total Variation Majorization Minimization (TV-MM) Approach to Radiometer Brightness Temperature Gridding and Reconstruction

This paper presents the implementation of an algorithm to enhance the image resolution of the Earth's surface brightness temperature (T B ) data measured by radiometers such as the one onboard of the Soil Moisture Active Passive (SMAP) mission. A key step in radiometer T B processing is the conversion of the swath-based calibrated antenna temperature (T A ) measurements to the Level 3 Earth-centered grid. The simplest algorithm to transform this data from swath to gridded format is called drop-in-the-bucket which simply averages surrounding noisy T A samples to form a T B value at the gridded location. This method reduces noise, however produces low resolution products. To obtain a higher resolution product, SMAP uses other techniques such the Backus-Gilbert (BG) algorithm, which is the conventional method used in microwave radiometry. Although this method performs the required interpolation, it is not effective in denoising and removing blurring effects due to antenna filtering of the radiometer image data. Our motivation for this development is to further improve the resolution through post-processing of the radiometer T B image, a highly cost-effective method of image enhancement. The approach adapted in this work is based on the minimization of the Total Variation (TV) regularized objective function that is used extensively in solving general ill-posed linear inverse problems in image processing. Since the TV-based objective function is convex but not everywhere differentiable, there exists many numerical algorithms that can estimate the solution and the one selected for this work is called Majorization- Minimization (MM). By applying this algorithm, simulation experiments were performed based on synthetic data from the Geophysical model as well as real SMAP data to demonstrate the effectiveness of the technique. Results were then compared against the BG method.

Wing Lee↗

Classifying Microwave Radiometer Observations Over the Netherlands Into Dry, Shallow-, and Non-Shallow Precipitation Using A Random Forest Model

Spaceborne microwave radiometers represent an important component of the Global Precipitation Measurement (GPM) mission due to their frequent sampling of rain systems. Microwave radiometers measure microwave radiation (brightness temperatures, Tb), which can be converted into precipitation estimates with appropriate assumptions. However, detecting shallow precipitation systems using space-borne radiometers is challenging, especially over land, as their weak signals are hard to differentiate from those associated with dry conditions. This study uses a random forest model (RF) to classify microwave radiometer observations as dry, shallow, or nonshallow over the Netherlands - a region with varying surface conditions and frequent occurrence of shallow precipitation. The RF is trained on five years of data (2016-2020) and tested with two independent years (2015, 2021). The observations are classified using ground-based weather radar echo top heights. Various RF models are assessed, such as using only GPM’s Microwave Imager (GMI) Tb values as input features or including spatially aligned ERA-5 2-meter temperature and freezing level reanalysis and/or Dual Precipitation Radar (DPR) observations. Independent of the input features, the model performs best in summer and worst in winter. The model classifies observations from high-frequency channels (≥85 GHz) with lower Tb-values as non-shallow, higher values as dry, and those in between as shallow. Misclassified footprints exhibit radiometric characteristics corresponding to their assigned class. Case studies reveal dry observations misclassified as shallow are associated with lower Tb-values, likely resulting from the presence of ice particles in non-precipitating clouds. Shallow footprints misclassified as dry are likely related to the absence of ice particles.

Linda Bogerd↗

Operational Correction for the Temperature Dependence of A Class of Hyperspectral Radiometers

The correction for temperature response of optical radiometers implies access to their working temperature (i.e., either the internal or ambient one with the radiometers in thermal equilibrium). With specific reference to a class of widely used hyperspectral radiometers lacking a thermistor to measure the internal temperature, this work investigated the potential for operational corrections relying on the ambient temperature derived from the radiometer dark digital counts. With the objective to keep within approximately 1% the uncertainty for radiometric corrections in the 400–800-nm spectral range, findings showed the applicability of the method for ambient temperatures higher than approximately 30°C. The alternative use of an ambient temperature proxy, determined from the air temperature incremented by a few degrees Celsius, was shown a valid solution to constrain the uncertainty of radiometric corrections to within 1% over the entire 0°–40°C interval.

Giuseppe Zibordi↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Calibration of the DSCOVR EPIC Visible and NIR Channels using Multiple LEO Radiometers

The first five years of operation of the Deep Space Climate Observatory (DSCOVR) Earth Polychromatic Imaging Camera (EPIC) at the Lagrange one point have produced results that uniquely complement the data from currently operating low orbit Earth-observing instruments. In this paper we describe an updated unified approach to EPIC calibration. In this approach, calibration coefficients and their trends were obtained by comparing EPIC observations to the measurements from polar orbiting radiometers. In this study L1B reflectances from Moderate Resolution Imaging Spectroradiometer (MODIS) onboard the Aqua and Terra satellites, Multi-angle Imaging Spectroradiometer (MISR) onboard Terra and Visible Infrared Imaging Radiometer (VIIRS) onboard the Suomi National Polar-orbiting Partnership (Suomi NPP) spacecraft were used to infer calibration coefficients for four EPIC visible and near-infrared channels: 443 nm, 551 nm, 680 nm, and 780 nm. EPIC Version three measurements made between June 2015 and August 2020 were used for comparison. The calibration procedure identifies the most homogeneous low Earth orbit radiometer scenes matching scattering angles that are temporarily and spatially collocated with EPIC observations. These scenes are used to determine reflectance to count (R/C) ratios in spectrally analogous channels. Seasonal average R/C ratios were analyzed to obtain EPIC calibration gains and trends. The trends for the full dataset period are not statistically significant except in the 443 nm channel. No significant changes in calibration were found after the instrument’s exit from safe hold in March 2020. The R/C ratios were also used to determine the differences in EPIC gains resulting from separate calibrations: against MODIS Aqua or Terra, as well as against forward or aftward MISR cameras. Statistical tests indicate that the differences between the two datasets are not significant except in the 780 nm channels where Aqua-derived coefficients may be around 2% lower compared to Terra. The dependence of EPIC calibration gains on the instrument scattering angle and on DSCOVR-Earth distance were investigated. Lastly, model Low Earth Orbit (LEO) reflectances calculated to match the EPIC viewing geometry were employed to study how EPIC calibration coefficients depend on EPIC-LEO viewing geometry differences. The effect of LEO and EPIC angular mismatch on calibration was shown to be small.

deep space climate observatory/earth polychromatic↗

Microwave radiometer and scatterometer design for the aquarius sea surface Salinity Mission

The measurement of sea surface salinity with L-band microwave radiometers is a very challenging task. Since the L-band brightness temperature variations associated with salinity changes are small, it is necessary to have a very sensitive and stable radiometer. In addition, the corrections for the ocean surface roughness require real time scatterometer measurements. The designs of the Aquarius radiometer and scatterometer are described in this paper.

sea surface salinity↗

Radio Frequency Interference Mitigation for the Planned SMAP Radar and Radiometer

NASA's planned SMAP mission will utilize a radar operating in a band centered on 1.26 GHz and a co-observing radiometer operating at 1.41 GHz to measure surface soil moisture. Both the radar and radiometer sub-systems are susceptible to radio frequency interference (RFI). Any significant impact of such interference requires mitigation in order to avoid degradation in the SMAP science products. Studies of RFT detection and mitigation methods for both the radar and radiometer are continuing in order to assess the risk to mission products and to refine the performance achieved.

radiometer↗

Imager-to-Radiometer In-flight Cross Calibration: RSP Radiometric Comparison with Airborne and Satellite Sensors

This work develops a method to compare the radiometric calibration between a radiometer and imagers hosted on aircraft and satellites. The radiometer is the airborne Research Scanning Polarimeter (RSP), which takes multi-angle, photo-polarimetric measurements in several spectral channels. The RSP measurements used in this work were coincident with measurements made by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS), which was on the same aircraft. These airborne measurements were also coincident with an overpass of the Landsat 8 Operational Land Imager (OLI). First we compare the RSP and OLI radiance measurements to AVIRIS since the spectral response of the multispectral instruments can be used to synthesize a spectrally equivalent signal from the imaging spectrometer data. We then explore a method that uses AVIRIS as a transfer between RSP and OLI to show that radiometric traceability of a satellite-based imager can be used to calibrate a radiometer despite differences in spectral channel sensitivities. This calibration transfer shows agreement within the uncertainty of both the various instruments for most spectral channels.

calibrating↗

Tracking Radiometer Calibration Stability Using Three-Point Onboard Calibration

Absolute calibration of radiometers is implemented onboard using one hot and one cold external calibration targets. However, two-point calibration methods are unable to differentiate calibration drifts and associated errors from fluctuations in receiver gain and offset. This paper investigates the use of onboard three-point calibration algorithm for microwave radiometers to track calibration drifts and characterize associated errors in Earth and Space measurements of the radiometer.

Calibration↗

Broadband and filter radiometers at Ross Island, Antarctica: detection of cloud ice phase versus liquid water influences on shortwave and longwave radiation

Abstract. Surface radiometer data from Ross Island, Antarctica, collected during the austral summer 2015–2016 by the US Department of Energy Atmospheric Radiation Measurement (ARM) program West Antarctic Radiation Experiment (AWARE), are used to evaluate how shortwave and longwave irradiance respond to changing cloud properties as governed by contrasting meteorological regimes. Shortwave atmospheric transmittance is derived from pyranometer measurements, and cloud conservative-scattering optical depth is derived from filter radiometer measurements at 870 nm. With onshore flow associated with marine air masses, clouds contain mostly liquid water. With southerly flow over the Transantarctic Mountains, orographic forcing induces substantial cloud ice water content. These ice and mixed-phase clouds attenuate more surface shortwave irradiance than the maritime-influenced clouds and also emit less longwave irradiance due to colder cloud base temperature. These detected irradiance changes are in a range that can mean onset or inhibition of surface melt over ice shelves. This study demonstrates how basic and relatively low-cost broadband and filter radiometers can be used to detect subtle climatological influences of contrasting cloud microphysical properties at very remote locations.

54 ENVIRONMENTAL SCIENCES↗

Development of a satellite microwave radiometer to sense the surface temperature of the world oceans

A proposed S-band radiometer for determining the ocean surface temperature with an absolute accuracy of + or - 1 Kelvin and a resolution of + or - .1 Kelvin was placed under the Advanced Applications Flight Experiment for further development into Nimbus readiness state. The results of assessing the following are described: effects due to the state of the sea surface, effects caused by the intervening atmosphere, and effects associated with imperfections in the instrument itself. An extensive sea truth program is also described for correlation of aircraft test flight measurements or of satellite remote measurement to in-situ data. An improved radiometer design is a modified Dicke-switch type with temperature stabilized, microwave integrated circuit, front-end and with a pulsed injection-noise nulling system. The radiometer has a multimode rectangular horn antenna with very low ohmic losses and a beam efficiency of 98% or better.

Hidy, G. M.↗

Studies with satellite radiometer data

The application of satellite radiometer data for analyzing and predicting global winds is discussed. The data obtained from the vertical temperature profile radiometer of the ITOS D satellite are described. The development of a nine level model for analyzing the physical properties of radiative transfer and cloud effects in the atmosphere is presented. Comparisons are made between various methods of applying the satellite radiometer data.

Halem, M.↗

High performance S-band horn antennas for radiometer use

Horn antennas of four types: pyramidal corrugated, conical corrugated, pyramidal dual mode and conical dual mode, have been constructed and evaluated for use as S-band radiometer antennas. Each of the structures is described and radiation patterns and impedance and resistive loss measurements including a layer of foreign material on a thin radome, are presented. A precision method for determining reflection losses is described using a multiprobe reflectometer technique. The same technique is also applied to the measurement of resistive losses by closing the ends of the antennas with short circuit plates and determining the losses from an accurate measurement of the reflection coefficient. The radiation patterns were recorded with the aid of a real-time digital computer. The stored patterns were then processed to yield gain and beam efficiency. It was concluded that it is possible to design a highly efficient antenna for radiometer use and to measure its parameters precisely. However, it was found that it is necessary to modify the conventional definition of beamwidth somewhat if this term is to be meaningful for radiometer applications.

Caldecott, R.↗