Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Six mechanisms used on the SSM/1 radiometer

Future USAF Block 5D Defense Meteorological Satellites will carry a scanning microwave radiometer sensor (SSM/1). SSM/1 senses the emission of microwave energy and returns to earth data used to determine weather conditions, such as rainfall rates, soil moisture, and oceanic wind speed. The overall design of the SSM/1 radiometer was largely influenced by the mechanisms. The radiometer was designed to be stowed in a cavity on the existing spacecraft. The deployment of the sensor is complex due to the constraint of this cavity and the need for precision in the deployment. The radiometer will continuously rotate, instead of oscillate, creating the need for a bearing and power transfer assembly and a momentum compensation device. The six mechanisms developed for this program are described.

Ludwig, H. R.↗

Performance of an airborne imaging 92/183 GHz radiometer during the Bering Sea Marginal Ice Zone Experiment (MIZEX-WEST)

An airborne imaging 92/183 GHz radiometer was recently flown onboard NASA's Convair 990 research aircraft during the February 1983 Bering Sea Marginal Ice Zone Experiment (MIZEX-WEST). The 92 GHz portion of the radiometer was used to gather ice signature data and to generate real-time millimeter wave images of the marginal ice zone. Dry atmospheric conditions in the Arctic resulted in good surface ice signature data for the 183 GHz double sideband (DSB) channel situated + or - 8.75 GHz away from the water vapor absorption line. The radiometer's beam scanner imaged the marginal ice zone over a + or - 45 degrees swath angle about the aircraft nadir position. The aircraft altitude was 30,000 feet (9.20 km) maximum and 3,000 feet (0.92 km) minimum during the various data runs. Calculations of the minimum detectable target (ice) size for the radiometer as a function of aircraft altitude were performed. In addition, the change in the atmospheric attenuation at 92 GHz under varying weather conditions was incorporated into the target size calculations. A radiometric image of surface ice at 92 GHz in the marginal ice zone is included.

Gagliano, J. A.↗

Effect of vegetation on soil moisture sensing observed from orbiting microwave radiometers

The microwave radiometric measurements made by the Skylab 1.4 GHz radiometer and by the 6.6 GHz and 10.7 GHz channels of the Nimbus-7 Scanning Multichannel Microwave Radiometer were analyzed to study the large-area soil moisture variations of land surfaces. Two regions in Texas, one with sparse and the other with dense vegetation covers, were selected for the study. The results gave a confirmation of the vegetation effect observed by ground-level microwave radiometers. Based on the statistics of the satellite data, it was possible to estimate surface soil moisture in about five different levels from dry to wet conditions with a 1.4 GHz radiometer, provided that the biomass of the vegetation cover could be independently measured. At frequencies greater than about 6.6 GHz, the radiometric measurements showed little sensitivity to moisture variation for vegetation-covered soils. The effects of polarization in microwave emission were studied also.

Wang, J. R.↗

An upward looking airborne millimeter wave radiometer for atmospheric water vapor sounding and rain detection

A 90/180 GHz multichannel radiometer is currently under development for NASA's 1985 Hurricane Mission onboard the Convair 990 research aircraft. The radiometer will be a fixed beam instrument with dual corrugated horns and a common lens antenna designed to operate simultaneously at 90 and 180 GHz. The all solid state front-end will contain three double side band data channels at 90 + or - 3 GHz, 180 + or - 3 GHz, and 180 + or - 7 GHz. The airborne radiometer will mount in a window port on the CV-990 and will maintain a fixed beam view approximately 14 degrees off zenith. The radiometer design is a Dicke chopper arrangement selected to achieve maximum absolute temperature accuracy and minimum brightness temperature sensitivity. Analog outputs of the three data channels will be calibrated dc voltages representing the observed radiometric brightness temperatures over the selected integration time.

Gagliano, J. A.↗

Design and development of a multibeam 1.4 GHz pushbroom microwave radiometer

The design and operation of a multiple beam, digital signal processing radiometer are discussed. The discussion includes a brief description of each major subsystem and an overall explanation of the hardware requirements and operation. A series of flight tests was conducted in which sea-truth sites, as well as an existing radiometer were used to verify the Pushbroom Radiometer performance. The results of these tests indicate that the Pushbroom Radiometer did meet the sensitivity design goal of 1.0 kelvin, and exceeded the accuracy requirement of 2.0 kelvin. Additional performance characteristics and test results are also presented.

Lawrence, R. W.↗

A cavity radiometer for Earth albedo measurement, phase 1

Radiometric measurements of the directional albedo of the Earth requires a detector with a flat response from 0.2 to 50 microns, a response time of about 2 seconds, a sensitivity of the order of 0.02 mw/sq cm, and a measurement uncertainty of less than 5 percent. Absolute cavity radiometers easily meet the spectral response and accuracy requirements for Earth albedo measurements, but the radiometers available today lack the necessary sensitivity and response time. The specific innovations addressed were the development of a very low thermal mass cavity and printed/deposited thermocouple sensing elements which were incorporated into the radiometer design to produce a sensitive, fast response, absolute radiometer. The cavity is applicable to the measurement of the reflected and radiated fluxes from the Earth surface and lower atmosphere from low Earth orbit satellites. The effort consisted of requirements and thermal analysis; design, construction, and test of prototype elements of the black cavity and sensor elements to show proof-of-concept. The results obtained indicate that a black body cavity sensor that has inherently a flat response from 0.2 to 50 microns can be produced which has a sensitivity of at least 0.02 mw/sq cm per micro volt ouput and with a time constant of less than two seconds. Additional work is required to develop the required thermopile.

Source record↗

Multiwavelength scanning radiometer for airborne measurements of scattered radiation within clouds

A multi-wavelength scanning radiometer has been developed for measuring the angular distribution of scattered radiation deep within a cloud layer. The purpose of the instrument is to provide measurements from which the single scattering albedo of clouds can be derived as a function of wavelength. The radiometer has a 1-deg field of view and scans in the vertical plane from 5 deg before zenith to 5 deg past nadir (190 deg aperture). The thirteen channels of the cloud absorption radiometer are located between 0.5 and 2.3 microns and were selected to avoid the molecular absorption bands in the near-infrared. The first seven channels of the radiometer are simultaneously and continuously sampled, while the eighth registered channel is selected from among the six channels on a filter wheel. This paper describes the optical, mechanical and electrical design of the instrument and presents some early results obtained from measurements taken aboard the University of Washington's B-23 aircraft to illustrate the performance of the instrument.

King, Michael D.↗

Airborne Calibration Of An Orbiting Radiometer

Experiment demonstrates feasibility of using recently calibrated airborne radiometer to calibrate satellite-borne radiometer monitoring Earth and not calibrated since before launch. Calibration technique helps to assure Earth scientists of accuracy of satellite radiometric measurements taken during long time. Optical train of orbiting radiometer degraded slowly and sensitivities of detectors and gains of amplifiers changed slowly in outer-space environment, but frequent calibrations by airborne-radiometer technique make it possible to compensate for these changes.

Smith, Gilbert R.↗

The measurement of atmospheric water vapor - Radiometer comparison and spatial variations

Two water vapor radiometer (WVR) experiments were conducted to evaluate whether such instruments are both suitable and necessary to correct for propagation effects that are induced by precipitable water vapor (PWV) on signals from GPS and VLBI. WVRs are suitable for these corrections if they provide wet path delays to better than 0.5 cm. They are needed if spatial variations of PWV result in complicated, direction-dependent propagation effects that are too complex to be parametrized in the GPS or VLBI geodetic solution. The suitability of radiometers was first addressed by comparing six airport WVRs for two weeks. While two WVRs showed an average wet path delay bias of only 0.1 cm, others were biased by 1-3 cm relative to each other and relative to radiosondes. The second experiment addressed the question whether radiometers are needed for the detection of inhomogeneities in the wet delay. Three JPL D-series radiometers were operated at three sites 50 km apart. The WVRs simultaneously sampled PWV at different azimuths and elevations in search of spatial variations of PWV. On one day of this second experiment evidence was found for spatial variations of the wet path delay as high as 20 percent of the total wet path delay.

Rocken, C.↗

A validation tool for the Earth Radiation Budget Experiment nonscanning radiometers

Two data sets for one geographical scene are used as a comparative validation tool to verify the quality of radiometer measurements taken for NASA's Earth Radiation Budget Experiment (ERBE). The measurements are taken from four independent nonscanning radiometers installed on the Earth Radiation Budget Satellite and two NOAA spacecraft. Two radiometers measure radiation in the 0.2-50-micron range, and two measure solar reflected energy in spectral band ranging from 0.2 to 5 microns. Calculated top-of-atmosphere flux-value measurements for day and night demonstrate significant correlation as well as consistency and stability over a three-year period. It is concluded that intercomparisons of intersections between the satellites are necessary over varied geographical scenes to utilize the subject method in validating the measurements of the ERBE nonscanning radiometer.

Bolden, William C.↗

Multi-frequency, multi-polarization SAR and radiometer sea ice classification

Microwave remotely sensed data were acquired simultaneously in March 1988 over Beaufort, Chukchi, and Bering Sea ice using the JPL multifrequency, polarimetric synthetic aperture radar (SAR), and multifrequency dual-polarization GSFC radiometer. The experiment was conducted as a series of coordinated underflights of the DMSP SSM/I satellite radiometer to validate ice products derived from its radiance values. Concurrent flights by an NRL P-3 aircraft enabled overlapping high-resolution, single-frequency images to be acquired over the same surfaces using a Ka-band scanning microwave radiometer. Precise coregistration to an accuracy of 100 m, +/- 25 m enables comparison of temporally and spatially coincident active and passive microwave datasets. Three-channel polarimetric SAR data are compared with dual-polarized radiometer data at several SSM/I frequencies, showing backscatter signatures to be highly correlated with radiometric temperatures. Further comparisons are used to evaluate ice concentration retrievals and to show how multiparameter datasets can be used to resolve ambiguities present in identifying certain sea ice forms with a single microwave instrument.

Drinkwater, Mark R.↗

Design studies of large aperture, high-resolution Earth science microwave radiometers compatible with small launch vehicles

High-spatial-resolution microwave radiometer sensing from space with reasonable swath widths and revisit times favors large aperture systems. However, with traditional precision antenna design, the size and weight requirements for such systems are in conflict with the need to emphasize small launch vehicles. This paper describes tradeoffs between the science requirements, basic operational parameters, and expected sensor performance for selected satellite radiometer concepts utilizing novel lightweight compactly packaged real apertures. Antenna, feed, and radiometer subsystem design and calibration are presented. Preliminary results show that novel lightweight real aperture coupled with state-of-the-art radiometer designs are compatible with small launch systems, and hold promise for high-resolution earth science measurements of sea ice, precipitation, soil moisture, sea surface temperature, and ocean wind speeds.

Schroeder, Lyle C.↗

Polarimetric measurements of sea surface brightness temperatures using an aircraft K-band radiometer

This paper presents the first experimental evidence that the polarimetric brightness temperatures of sea surfaces are sensitive to ocean wind direction in the incidence angle range of 30 to 50 degrees. Our experimental data were collected by a K-band (19.35 GHz) polarimetric wind radiometer (WINDRAD) mounted on the NASA DC-8 aircraft. A set of aircraft radiometer flights was successfully completed in November 1993. We performed circle flights over National Data Buoy Center (NDBC) moored buoys deployed off the northern California coast, which provided ocean wind measurements. The first WINDRAD flight was made on November 4, 1993. There was clear weather with a wind speed of 12 m/s at 330 degrees around the Pt. Arena buoy. We circled the buoy at three incidence angles, and all data when plotted as functions of azimuth angles show clear modulations of several Kelvin. At 40 degrees incidence angle, there is a 5 Kelvin peak-to-peak signal in the second Stokes parameter Q and the third Stokes parameter U. The Q data maximum is in the upwind direction and U has a 45 degrees phase shift in azimuth as predicted by theory. There is also an up/downwind asymmetry of 2 Kelvin in the Q data, and 1 Kelvin in the U data. At 50 degrees incidence angle, the collected data show very similar wind direction signatures to the SSM/I model function. Additional flights were made on other days under cloudy conditions. Data taken at a wind speed of 8 m/s show that at 40 degrees incidence Q and U have a smaller azimuthal modulation of 3 Kelvin, probably due to the lower wind speed. Additionally, the simultaneously recorded video images of sea surfaces suggested that Q and U data were less sensitive to unpolarized geophysical variations, such as clouds and whitecaps, while the T(v) and T(h) increased by a few Kelvin when the radiometer beam crossed over clouds, or there was a sudden increase of whitecaps in the radiometer footprint. The results of our aircraft flights indicate that passive polarimetric radiometry has a strong potential for global ocean wind speed and direction measurements from space.

Yueh, Simon H.↗

Inflatable Antenna Microwave Radiometer for Soil Moisture Measurement

Microwave measurements of soil moisture are not being obtained at the required spatial Earth resolution with current technology. Recently, new novel designs for lightweight reflector systems have been developed using deployable inflatable antenna structures which could enable lightweight real-aperture radiometers. In consideration of this, a study was conducted at the NASA Langley Research Center (LaRC) to determine the feasibility of developing a microwave radiometer system using inflatable reflector antenna technology to obtain high spatial resolution radiometric measurements of soil moisture from low Earth orbit and which could be used with a small and cost effective launch vehicle. The required high resolution with reasonable swath width coupled with the L-band measurement frequency for soil moisture dictated the use of a large (30 meter class) real aperture antenna in conjunction with a pushbroom antenna beam configuration and noise-injection type radiometer designs at 1.4 and 4.3 GHz to produce a 370 kilometer cross-track swath with a 10 kilometer resolution that could be packaged for launch with a Titan 2 class vehicle. This study includes design of the inflatable structure, control analysis, structural and thermal analysis, antenna and feed design, radiometer design, payload packaging, orbital analysis, and electromagnetic losses in the thin membrane inflatable materials.

Bailey, M. C.↗

Radiometric Measurement Comparisons Using Transfer Radiometers in Support of the Calibration of NASA's Earth Observing System (EOS) Sensors

EOS satellite instruments operating in the visible through the shortwave infrared wavelength regions (from 0.4 micrometers to 2.5 micrometers) are calibrated prior to flight for radiance response using integrating spheres at a number of instrument builder facilities. The traceability of the radiance produced by these spheres with respect to international standards is the responsibility of the instrument builder, and different calibration techniques are employed by those builders. The National Aeronautics and Space Administration's (NASA's) Earth Observing System (EOS) Project Science Office, realizing the importance of preflight calibration and cross-calibration, has sponsored a number of radiometric measurement comparisons, the main purpose of which is to validate the radiometric scale assigned to the integrating spheres by the instrument builders. This paper describes the radiometric measurement comparisons, the use of stable transfer radiometers to perform the measurements, and the measurement approaches and protocols used to validate integrating sphere radiances. Stable transfer radiometers from the National Institute of Standards and Technology, the University of Arizona Optical Sciences Center Remote Sensing Group, NASA's Goddard Space Flight Center, and the National Research Laboratory of Metrology in Japan, have participated in these comparisons. The approaches used in the comparisons include the measurement of multiple integrating sphere lamp levels, repeat measurements of select lamp levels, the use of the stable radiometers as external sphere monitors, and the rapid reporting of measurement results. Results from several comparisons are presented. The absolute radiometric calibration standard uncertainties required by the EOS satellite instruments are typically in the +/- 3% to +/- 5% range. Preliminary results reported during eleven radiometric measurement comparisons held between February 1995 and May 1998 have shown the radiance of integrating spheres agreed to within +/- 2.5% from the average at blue wavelengths and to within +/- 1.7% from the average at red and near infrared wavelengths. This level of agreement lends confidence in the use of the transfer radiometers in validating the radiance scales assigned by EOS instrument calibration facilities to their integrating sphere sources.

Butler, James J.↗

Comparison of Profiling Microwave Radiometer, Aircraft, and Radiosonde Measurements From the Alliance Icing Research Study (AIRS)

Measurements from a profiling microwave radiometer are compared to measurements from a research aircraft and radiosondes. Data compared is temperature, water vapor, and liquid water profiles. Data was gathered at the Alliance Icing Research Study (AIRS) at Mirabel Airport outside Montreal, Canada during December 1999 and January 2000. All radiometer measurements were found to lose accuracy when the radome was wet. When the radome was not wetted, the radiometer was seen to indicate an inverted distribution of liquid water within a cloud. When the radiometer measurements were made at 15 deg. instead of the standard zenith, the measurements were less accurate.

Reehorst, Andrew L.↗

Analytical and Experimental Characterization of a Linear-Array Thermopile Scanning Radiometer for Geo-Synchronous Earth Radiation Budget Applications

The Thermal Radiation Group, a laboratory in the department of Mechanical Engineering at Virginia Polytechnic Institute and State University, is currently working towards the development of a new technology for cavity-based radiometers. The radiometer consists of a 256-element linear-array thermopile detector mounted on the wall of a mirrored wedgeshaped cavity. The objective of this research is to provide analytical and experimental characterization of the proposed radiometer. A dynamic end-to-end opto-electrothermal model is developed to simulate the performance of the radiometer. Experimental results for prototype thermopile detectors are included. Also presented is the concept of the discrete Green's function to characterize the optical scattering of radiant energy in the cavity, along with a data-processing algorithm to correct for the scattering. Finally, a parametric study of the sensitivity of the discrete Green's function to uncertainties in the surface properties of the cavity is presented.

Sorensen, Ira J.↗

The Aquarius Ocean Salinity Mission High Stability L-band Radiometer

The NASA Earth Science System Pathfinder (ESSP) mission Aquarius, will measure global ocean surface salinity with approx.120 km spatial resolution every 7-days with an average monthly salinity accuracy of 0.2 psu (parts per thousand). This requires an L-band low-noise radiometer with the long-term calibration stability of less than or equal to 0.15 K over 7 days. The instrument utilizes a push-broom configuration which makes it impractical to use a traditional warm load and cold plate in front of the feedhorns. Therefore, to achieve the necessary performance Aquarius utilizes a Dicke radiometer with noise injection to perform a warm - hot calibration. The radiometer sequence between antenna, Dicke load, and noise diode has been optimized to maximize antenna observations and therefore minimize NEDT. This is possible due the ability to thermally control the radiometer electronics and front-end components to 0.1 Crms over 7 days.

Pellerano, Fernando A.↗