Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Localized keyhole pore prediction during laser powder bed fusion via multimodal process monitoring and X-ray radiography

Systematic fault detection and control during laser powder bed fusion (L-PBF) has been a long-standing objective for system manufacturers and researchers in the additive manufacturing (AM) industry. This manuscript investigates a data fusion approach for detection of keyhole porosity formation during laser irradiation of Ti-6Al-4V substrates by concurrent recording of thermally induced optical emission measured using both off-axis and coaxial photodiode sensors, and acoustic emission. Subsurface defect formation was monitored via high-speed synchrotron X-ray imaging at 20,000 frames per second, enabling temporal registration of keyhole pore formation events to the monitoring signals at a resolution of 50 µs. We developed data fusion machine learning (ML) models for localized prediction of keyhole pore formation at various time scales ranging from 0.5 ms to 2 ms. The signal segments were featurized using two independent approaches: (1) power spectral density (PSD) and (2) highly comparative time series analysis (HCTSA) framework. The extracted features from different sensor modalities were fused together to construct a multimodal feature space and sequential feature selection was used to determine the most informative features for training the ML models. The predictive performance was evaluated for three classifying algorithms: Support Vector Machine (SVM), K-Nearest Neighbor (KNN), and Gaussian Naive Bayes (GNB). As a result, pore formation events were predicted with up to 0.95 F1-score, 1.0 recall and 0.94 accuracy. The most heavily weighted features indicate that model performance is chiefly governed by the acoustic monitoring signal, with a secondary contribution from the optical emission sensors.

36 MATERIALS SCIENCE↗

A semiempirical transparency model for dual energy cargo radiography applications

Cargo containers passing through ports are scanned by non-intrusive inspection systems to search for concealed illicit materials. By using two photon beams with different energy spectra, dual energy inspection systems are sensitive to both the area density and the atomic number of cargo contents. Most literature on the subject assumes a simple exponential attenuation model for photon intensity in which only free streaming photons are detected. However, this approximation neglects second order effects such as scattering, leading to a biased model and thus incorrect material predictions. This work studies the accuracy of the free streaming model by comparing it to simulation outputs, finding that the model shows poor atomic number reconstruction accuracy at high- Z and suffers significantly if the source energy spectra and detector response function are not known exactly. To address these challenges, this work introduces a semiempirical transparency model which modifies the free streaming model by rescaling different components of the mass attenuation coefficient, allowing the model to capture secondary effects ignored by the free streaming model. The semiempirical model displays improvement agreement with simulated results at high- Z and shows excellent extrapolation to materials and thicknesses which were not included during the calibration step. Furthermore, this work demonstrates that the semiempirical model yields accurate atomic number predictions even when the source spectra and detector response are not known exactly. In conclusion, using the semiempirical model, manufacturers can perform a simple calibration to enable more precise Z reconstruction capabilities, which has the potential to significantly improve the performance of existing dual energy radiographic systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Demonstrating imaging plate detector stacks for proton radiography using exploding pusher capsules

A new detector design has been fielded on the Omega-60 laser facility using a D 3 He backlighter capsule to radiograph a magnetized experiment. D 3 He capsules produce a low flux (~ 10 8 total yield in 4π) of protons requiring detectors with close-to single-particle sensitivity to be employed. The new detector stack consisted of both imaging plate (IP) and CR-39 to detect 14.7 MeV protons where, historically, only CR-39 has been used. IP is sensitive to significant contributions in signal from both x-rays and protons so additional filtering has to be added to attenuate the x-rays. Here, the signals and features observed from a single shot are detected by both IP and CR-39, giving confirmation that it is protons creating the signatures on the IP. Measurements of PSL/pixel are used to calculate approximate on-shot proton yields and agree with commonly measured yields. A second IP is used at the rear of the stack to measure, and subsequently remove, a background signal. The spatial resolution at the IP is limited, primarily, by a range of proton energies with varying deflections being recorded at the detector, causing potential ‘blurring’ of features. We find for this setup that the blurring effect is less than the smallest identifiable features observed at the detector, and therefore of minimal impact. A large benefit to this new stack design is that IP can be scanned and processed on much faster timescales than CR-39 allowing for prompt shot feedback. Future designs and modifications to the stack design fielded on this experiment could help improve the contrast of the radiograph on IP, as well as detecting protons produced at alternative energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple monoenergetic gamma radiography (MMGR) with a compact superconducting cyclotron

Smuggling of special nuclear materials and nuclear devices through borders and ports of entry constitutes a major risk to global security. Technologies are needed to reliably screen the flow of commerce for the presence of high-Z materials such as uranium and plutonium. Here, we present an experimental proof-of-concept of a technique that uses inelastic (p,p') nuclear reactions to generate monoenergetic photons, which provide means to measure the areal density and the effective-Z (Z eff ) of an object with an accuracy surpassing that achieved by current methods. We use an ION-12 SC superconducting 12 MeV proton cyclotron to produce 4.4, 6.1, 6.9, and 7.1 MeV photons from a variety of nuclear reactions. Using these photons in a transmission mode, we show that we are able to accurately reconstruct the areal densities and Zeff of a test object. This methodology could enable mobile applications to screen commercial cargoes with high material specificity, providing a means of distinguishing common cargo materials from high-Z materials that include uranium and plutonium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

Causes of fuel–ablator mix inferred from modeling of monochromatic time-gated radiography of OMEGA cryogenic implosions

Here, we present evidence, in the context of OMEGA cryogenic target implosions, that laser imprint, known to be capable of degrading laser-direct-drive target performance, plays a major role in generating fuel–ablator mix. OMEGA cryogenic target implosions show a performance boundary correlated with acceleration-phase shell stability; for sufficiently low adiabats (where the adiabat is the ratio of the pressure to the Fermi pressure) and high in-flight aspect ratios (IFAR's), the neutron-weighted shell areal density and neutron yield relative to the clean simulated values sharply decline. Direct evidence of Rayleigh–Taylor fuel–ablator mixing was previously obtained using a Si Heα backlighter driven by an ~20-ps short pulse generated by OMEGA EP. The shadow cast by the shell shortly prior to stagnation, as diagnosed using backlit radiographs, shows a softening near the limb, which is evidence of an ablator–fuel mix region for a low-adiabat implosion (α ~ 1.9, IFAR = 14) but not for a moderate adiabat implosion (α ~ 2.5, IFAR = 10). We find good agreement between experimental and synthetic radiographs in simulations that model laser imprint and account for uncertainty in the initial ablator thickness. Furthermore, we further explore the role of other mechanisms such as classical instability growth at the fuel–ablator interface, species concentration diffusion, and long-wavelength drive and target asymmetries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High spatial resolution and contrast radiography of hydrodynamic instabilities at the National Ignition Facility

In this work, we are developing techniques for studying the Rayleigh–Taylor (RT) and Richtmyer–Meshkov (RM) instabilities in a planar geometry at high-energy-densities at the National Ignition Facility (NIF). In particular, through the improvement of experimental imaging quality, we are progressing toward the study of the turbulent regime of the mixing regions in capsule implosion experiments for inertial confinement fusion, which requires few micrometers resolution. Using 60 NIF beams, a solid shock tube is driven launching a shock wave that crosses the interface between a dense and a light material pre-machined in the target to obtain sinusoidal ripples, which results in RM and RT instabilities that are imaged using the NIF Crystal Backlighter Imager. High-quality images were obtained with a mean resolution of 7 μm and improved contrast. While the obtained resolution does not allow the observation of the smallest scale of the “turbulent” energy spectrum, the generated image encompasses 63% of the total flow energy, a 50% improvement over previous studies, which is observed for the first time a roll-up feature in a high energy density-type RT experiment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of an x-ray radiography platform to study laser-direct-drive energy coupling at the National Ignition Facility

A platform has been developed to study laser-direct-drive energy coupling at the National Ignition Facility (NIF) using a plastic sphere target irradiated in a polar-direct-drive geometry to launch a spherically converging shock wave. To diagnose this system evolution, eight NIF laser beams are directed onto a curved Cu foil to generate Heα line emission at a photon energy of 8.4 keV. These x rays are collected by a 100-ps gated x-ray imager in the opposing port to produce temporally gated radiographs. The platform is capable of acquiring images during and after the laser drive launches the shock wave. A backlighter profile is fit to the radiographs, and the resulting transmission images are Abel inverted to infer radial density profiles of the shock front and to track its temporal evolution. Here, the measurements provide experimental shock trajectories and radial density profiles that are compared to 2D radiation-hydrodynamic simulations using cross-beam energy transfer and nonlocal heat-transport models.

47 OTHER INSTRUMENTATION↗

Quantitative radiography for determining density fluctuations in HED experiments

We have developed a method to extract density fluctuation measurements from x-ray radiographs of high-energy density (HED) instability growth and turbulence experiments. We use this information to calculate density fluctuation statistics for constraining the performance of turbulent mix models in HED systems. The density calculation combines image filtering, removal of systemic effects such as backlighter variation, calculation of transmission across multiple materials, and use of tracer materials to generate an approximate single-material density field. From the density map, we calculate both average density and a variance-like moment b (density-specific-volume covariance), which we compare to our models. We infer both quantities from a single image, which is significantly more information than the historic single scalar mix width measurements. We also develop a method of analyzing simulation outputs that incorporate both the density fluctuation metric from a turbulence model and the bulk material maps from the hydrodynamic code. This analysis helps address the question of how to initialize the simulations for best comparison to data from systems with large separations of scale in the mixing perturbation initial condition. We find that our data analysis method yields 1D average density and b curves with similar morphology and amplitudes as those from preliminary simulation comparisons.

47 OTHER INSTRUMENTATION↗

Optimizing time integration for accurate recovery of shockwave interface location in radiography

We present simulations and experiments of time integrated radiographic imaging of a moving 1D shock wave front and a quantitative method for determining the statistical error in locating the shock front as a function of integration time and noise in the radiograph. We discuss the trade-off between increasing motion blur, which leads to decreased shock front location certainty, and increasing signal-to-noise, which leads to improved image quality with increasing integration time. We find an optimum integration time between a short integration time, where noise limits the error, and a long integration time, where motion blurring limits the error. This methodology can be used to tune experimental configurations to obtain the highest quality radiograph for a given experimental configuration.

Bremsstrahlung↗

Deep learning-based spatio-temporal fusion for high-fidelity ultra-high-speed X-ray radiography

Full-field ultra-high-speed (UHS) X-ray imaging experiments have been well established to characterize various processes and phenomena. However, the potential of UHS experiments through the joint acquisition of X-ray videos with distinct configurations has not been fully exploited. In this paper, we investigate the use of a deep learning-based spatio-temporal fusion (STF) framework to fuse two complementary sequences of X-ray images and reconstruct the target image sequence with high spatial resolution, high frame rate and high fidelity. We applied a transfer learning strategy to train the model and compared the peak signal-to-noise ratio (PSNR), average absolute difference (AAD) and structural similarity (SSIM) of the proposed framework on two independent X-ray data sets with those obtained from a baseline deep learning model, a Bayesian fusion framework and the bicubic interpolation method. The proposed framework outperformed the other methods with various configurations of the input frame separations and image noise levels. With three subsequent images from the low-resolution (LR) sequence of a four times lower spatial resolution and another two images from the high-resolution (HR) sequence of a 20 times lower frame rate, the proposed approach achieved average PSNRs of 37.57 dB and 35.15 dB, respectively. When coupled with the appropriate combination of high-speed cameras, the proposed approach will enhance the performance and therefore the scientific value of UHS X-ray imaging experiments.

deep learning↗

Overview of the LANL Multi-Probe Radiography Project [Slides]

Future radiographic facilities for the U.S. defense program will be required to provide more information as simulation codes improve in both physics’ fidelity and resolution. A possible approach is to use more types of probe beams in addition to, or instead of X-rays, generated by 20-MeV electron accelerators from a small number of directions. High power short-pulse laser systems can generate beams of protons, neutrons and electrons, as well as X-rays. The cost of these systems is falling rapidly. So, it can be imagined that deploying multiple short-pulse lasers along with other, more traditional probes, will become feasible. In this project, we are following three paths to determine if such an approach will succeed for cm-scale objects. The first is an experimental one to determine if the presence of multiple short-pulse probes cause interference with each other, especially while radiographing dynamic objects. The second leg of this project is to determine if having multiple types of probes really does give more information on composition. Finally, an overall assessment of the viability of this approach will be made. Examples from recent experiments at the Omega EP laser will be presented. The initial approach to evaluating radiographs with multiple probes using the Bayesian Inference Engine (BIE) also will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗