Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation physics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cherenkov-type three-dimensional breakdown behavior of the Bloch-point domain wall motion in the cylindrical nanowire

A three-dimensional breakdown behavior of the magnetic Bloch-point domain wall (BP-DW) propagation was investigated in a ferromagnetic nanowire with the variation of the external magnetic field by means of micromagnetic simulation. As magnetic field strength increases up to a threshold value, the BP-DW velocity approaches a critical phase velocity of the spontaneously emitting spin wave (SW), where a Cherenkov-type DW breakdown phenomenon is observed originating from an interaction between the spontaneously emitting SW and the BP-DW. It is found that the velocity of the BP-DW approaches a maximum value (~2000 m/s) due to the intrinsic reversal time of a BP spin texture. This suggests that although cylindrical ferromagnetic nanowires might be free from the two-dimensional Walker breakdown phenomenon, there exists a Cherenkov-type three-dimensional breakdown behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the parity-violating asymmetry in the 𝑁 → Δ transition at low 𝑄 2

Here, we report the measurement of the parity-violating asymmetry in the 𝑁 → Δ transition via the 𝑒 − + 𝑝 → 𝑒 − + Δ + reaction at two different kinematic points with low four-momentum transfer 𝑄 2 . Measurements were made with incident electron beam energies of 0.877 and 1.16 GeV, corresponding to 𝑄 2 values of 0.0111 and 0.0208 (GeV/c) 2 , respectively. These measurements put constraints on a low-energy constant in the weak Lagrangian, 𝑑 Δ , corresponding to a parity-violating electric-dipole transition matrix element. This matrix element has been shown to be large in the strangeness-changing channel, via weak hyperon decays such as Σ + → 𝑝⁢𝛾. The measurements reported here constrain 𝑑 Δ in the strangeness-conserving channel. The final asymmetries were −0.65±1.00⁢(stat.)±1.02⁢(syst.) ppm (parts per million) for 0.877 GeV and −3.59±0.82⁢(stat.)±1.33⁢(syst.) ppm for 1.16 GeV. With these results we deduce a small value for 𝑑 Δ , consistent with zero, in the strangeness-conserving channel, in contrast to the large value for 𝑑 Δ previously reported in the strangeness-changing channel.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Parity-violating inelastic electron-proton scattering at low Q 2 above the resonance region

We report the measurement of the parity-violating asymmetry for the inelastic scattering of electrons from the proton, at $Q^2 = 0.082$ GeV$^2$ and $ W = 2.23$ GeV, above the resonance region. The result $A_{\rm Inel} = - 13.5 \pm 2.0 ({\rm stat}) \pm 3.9 ({\rm syst})$ ppm agrees with theoretical calculations, and helps to validate the modeling of the $\gamma Z$ interference structure functions $F_1^{\gamma Z}$ and $F_2^{\gamma Z}$ used in those calculations, which are also used for determination of the two-boson exchange box diagram ($\Box_{\gamma Z}$) contribution to parity-violating elastic scattering measurements. A positive parity-violating asymmetry for inclusive $\pi^-$ production was observed, as well as positive beam-normal single-spin asymmetry for scattered electrons and a negative beam-normal single-spin asymmetry for inclusive $\pi^-$ production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Angular distribution of 𝛾 rays from a neutron-induced 𝑝-wave resonance of 132 Xe

A neutron-energy dependent angular distribution was measured for individual 𝛾 rays from the 3.2 eV 𝑝-wave resonance of 131 Xe+⁢𝑛, that shows enhanced parity violation owing to a mixing between 𝑠- and 𝑝-wave amplitudes. The 𝛾-ray transitions from the 𝑝-wave resonance were identified, and the angular distribution with respect to the neutron momentum was evaluated as a function of the neutron energy for 7132 keV 𝛾 rays, which correspond to a transition to the 1807 keV excited state of 132 Xe. The angular distribution is considered to originate from the interference between 𝑠- and 𝑝-wave amplitudes, and will provide a basis for a quantitative understanding of the enhancement mechanism of the fundamental parity violation in compound nuclei.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

QED nuclear medium effects at EIC energies

Here, we present the first calculation of quantum electrodynamics (QED) nuclear medium effects under the experimental conditions of future Electron-Ion Collider (EIC) experiments. Our work offers numerical estimates, particularly in the context of inclusive deep inelastic scattering on a $^{208}_{82}$Pb nucleus. While prior studies have predominantly focused on elastic scattering, our investigation extends to the more complex scenarios of inelastic processes within a nuclear medium. Our findings suggest that the cross section corrections due to QED nuclear medium effects could be substantial, reaching or exceeding the level of experimental precision. This work further compares the effects of single rescattering events with those of multiple rescatterings, as particles travel the nuclear volume. We estimate the dominant source of the uncertainties associated with our formalism by varying the scale of the atomic physics where the screening of the electric field of the nucleus happens. This calculation not only contributes to the understanding of QED nuclear medium effects, but also offers a path to a more precise extraction of the process-independent nonperturbative structure of nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Analytical Bit-Error Model of NAND Flash Memories for Dosimetry Application

In this work, we provide an analytical model for the total ionizing dose (TID) effects on the bit error statistics of commercial flash memory chips. We have validated the model with experimental data collected by irradiating several commercial NAND flash memory chips from different technology nodes. We find that our analytical model can project bit errors at higher TID values (~ 20 krad(Si)) from measured data at lower TID values (<1 krad(Si)). Based on our model and the measured data, we have formulated basic design rules for using a commercial flash memory chip as a dosimeter. We discuss the impact of NAND chip-to-chip variability, noise margin and the intrinsic errors on the dosimeter design using detailed experimentation.

3-D NAND↗

Results of a Geant4 benchmarking study for bio‐medical applications, performed with the G4‐Med system

Geant4, a Monte Carlo Simulation Toolkit extensively used in bio-medical physics, is in continuous evolution to include newest research findings to improve its accuracy and to respond to the evolving needs of a very diverse user community. In 2014, the G4-Med benchmarking system was born from the effort of the Geant4 Medical Simulation Benchmarking Group, to benchmark and monitor the evolution of Geant4 for medical physics applications. The G4-Med system was first described in our Medical Physics Special Report published in 2021. Results of the tests were reported for Geant4 10.5. Purpose In this work, we describe the evolution of the G4-Med benchmarking system. Methods The G4-Med benchmarking suite currently includes 23 tests, which benchmark Geant4 from the calculation of basic physical quantities to the simulation of more clinically relevant set-ups. New tests concern the benchmarking of Geant4-DNA physics and chemistry components for regression testing purposes, dosimetry for brachytherapy with a 125 I source, dosimetry for external x-ray and electron FLASH radiotherapy, experimental microdosimetry for proton therapy, and in vivo PET for carbon and oxygen beams. Regression testing has been performed between Geant4 10.5 and 11.1. Finally, a simple Geant4 simulation has been developed and used to compare Geant4 EM physics constructors and physics lists in terms of execution times. Results In summary, our EM tests show that the parameters of the multiple scattering in the Geant4 EM constructor G4EmStandardPhysics_option3 in Geant4 11.1, while improving the modeling of the electron backscattering in high atomic number targets, are not adequate for dosimetry for clinical x-ray and electron beams. Therefore, these parameters have been reverted back to those of Geant4 10.5 in Geant4 11.2.1. The x-ray radiotherapy test shows significant differences in the modeling of the bremsstrahlung process, especially between G4EmPenelopePhysics and the other constructors under study (G4EmLivermorePhysics, G4EmStandardPhysics_option3, and G4EmStandardPhysics_option4). These differences will be studied in an in-depth investigation within our Group. Improvement in Geant4 11.1 has been observed for the modeling of the proton and carbon ion Bragg peak with energies of clinical interest, thanks to the adoption of ICRU90 to calculate the low energy proton stopping powers in water and of the Linhard–Sorensen ion model, available in Geant4 since version 11.0. Nuclear fragmentation tests of interest for carbon ion therapy show differences between Geant4 10.5 and 11.1 in terms of fragment yields. In particular, a higher production of boron fragments is observed with Geant4 11.1, leading to a better agreement with reference data for this fragment. Conclusions Based on the overall results of our tests, we recommend to use G4EmStandardPhysics_option4 as EM constructor and QGSP_BIC_HP with G4EmStandardPhysics_option4, for hadrontherapy applications. The Geant4-DNA physics lists report differences in modeling electron interactions in water, however, the tests have a pure regression testing purpose so no recommendation can be formulated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

𝐹 𝐾 ⁡/𝐹 𝜋 from Möbius domain-wall fermions solved on gradient-flowed HISQ ensembles

We report the results of a lattice quantum chromodynamics calculation of 𝐹 𝐾 ⁡/𝐹 𝜋 using Möbius domain-wall fermions computed on gradient-flowed 𝑁 𝑓 =2 +1 +1 highly improved staggered quark (HISQ) ensembles. The calculation is performed with five values of the pion mass ranging from 130 ≲ 𝑚 𝜋 ≲ 400 MeV , four lattice spacings of 𝑎 ∼ 0.15, 0.12, 0.09 and 0.06 fm and multiple values of the lattice volume. The interpolation/extrapolation to the physical pion and kaon mass point, the continuum, and infinite volume limits are performed with a variety of different extrapolation functions utilizing both the relevant mixed-action effective field theory expressions as well as discretization-enhanced continuum chiral perturbation theory formulas. We find that the 𝑎 ∼ 0.06 fm ensemble is helpful, but not necessary to achieve a subpercent determination of 𝐹 𝐾 ⁡/𝐹 𝜋 . We also include an estimate of the strong isospin breaking corrections and arrive at a final result of 𝐹 $\hat{K}$ + ⁡ /𝐹 $\hat{𝜋}$ + = 1.1942⁢(45) with all sources of statistical and systematic uncertainty included. This is consistent with the Flavour Lattice Averaging Group average value, providing an important benchmark for our lattice action. Combining our result with experimental measurements of the pion and kaon leptonic decays leads to a determination of |𝑉 𝑢⁢𝑠 |/|𝑉 𝑢⁢𝑑 | = 0.2311⁢(10).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗