Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation detection systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Classifying Microwave Radiometer Observations Over the Netherlands Into Dry, Shallow-, and Non-Shallow Precipitation Using A Random Forest Model

Spaceborne microwave radiometers represent an important component of the Global Precipitation Measurement (GPM) mission due to their frequent sampling of rain systems. Microwave radiometers measure microwave radiation (brightness temperatures, Tb), which can be converted into precipitation estimates with appropriate assumptions. However, detecting shallow precipitation systems using space-borne radiometers is challenging, especially over land, as their weak signals are hard to differentiate from those associated with dry conditions. This study uses a random forest model (RF) to classify microwave radiometer observations as dry, shallow, or nonshallow over the Netherlands - a region with varying surface conditions and frequent occurrence of shallow precipitation. The RF is trained on five years of data (2016-2020) and tested with two independent years (2015, 2021). The observations are classified using ground-based weather radar echo top heights. Various RF models are assessed, such as using only GPM’s Microwave Imager (GMI) Tb values as input features or including spatially aligned ERA-5 2-meter temperature and freezing level reanalysis and/or Dual Precipitation Radar (DPR) observations. Independent of the input features, the model performs best in summer and worst in winter. The model classifies observations from high-frequency channels (≥85 GHz) with lower Tb-values as non-shallow, higher values as dry, and those in between as shallow. Misclassified footprints exhibit radiometric characteristics corresponding to their assigned class. Case studies reveal dry observations misclassified as shallow are associated with lower Tb-values, likely resulting from the presence of ice particles in non-precipitating clouds. Shallow footprints misclassified as dry are likely related to the absence of ice particles.

Linda Bogerd↗

Wide Operational Range Thermal Sensor

Bolometer system and method for detecting, at BLIP levels, presence of radiation over a broad range of wavelengths in an infrared spectrum and in a temperature range from 20 K to as high as room temperature. The radiation is received by a Si crystal having a region that is doped with one or more of In, Ga, S, Se, Te, B, Al, P, As and Sb in a concentration ratio in a range such as 5 x 10(exp -11) to 5 x 10(exp -6). Change in electrical resistance delta R due to receipt of the radiation is measured through a change in voltage difference or current within the crystal, and the quantity delta R is converted to an estimate of the amount of radiation received. Optionally, incident radiation having an energy high enough to promote photoconductivity is removed before detection.

John H Goebel↗

Contextually aware roadside radiation measurement testbed

Here we demonstrate a contextually aware multimodal roadside radiation measurement detection testbed for traffic monitoring applications in nuclear nonproliferation. Many variables in traffic such as vehicle or cargo size, mass, speed, shape, and distance of closest approach can have significant impacts on the radiation measured from a vehicle-transported radiation source. These factors can lead to uncertainties in the analysis of the radiation source, especially for lower-strength radiation sources of interest. Our testbed, known as the Multimodal Measurement System (MMS) uses non-radiation sensors including magnetometers, geophones, radiofrequency receivers, cameras, and LiDAR to extract contextual information about vehicles passing by the system. These contextual data can then be fused with data from radiation measurements to increase the system’s sensitivity and accuracy in nuclear threat detection applications. This work describes the instrumentation of the MMS and its data acquisition pipeline. Furthermore, we describe the pre-analysis performed on the raw multimodal data streams for data fusion, and the high-level machine learning analyses for detection and characterization. The variety of sensors within the MMS provides a valuable testbed that can be used to identify the combinations of contextual sensors that provide the greatest improvements to radiation source detection and characterization within the restrictions for various proliferation detection applications. The MMS is also modular so that additional combinations of sensors can be explored in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

The physics of heterodyne detection in the far-infrared: Transition from electric-field to photon-absorption detection in a simple system

The history of heterodyne detection is reviewed from the radiowave to the optical regions of the electromagnetic spectrum with emphasion the submillimeter/far infrared. The transition from electric field to photon absorption detection in a simple system is investigated. The response of an isolated two level detector to a coherent source of incident radiation is calculated for both heterodyne and video detection. When the processes of photon absorption and photon emission cannot be distinguished, the relative detected power at double- and sum-frequencies is found to be multiplied by a coefficient, which is less than or equal to unity, and which depends on the incident photon energy and on the effective temperature of the system.

Teich, M. C.↗

Methods and apparatus for improved thermal monitoring by correlating infrared emissivity to surface topography

Embodiments of the present disclosure provide an improved method and apparatus for thermal monitoring for a metal additive manufacturing system. An emissivity value of a top surface of an object to be manufactured is determined based, at least in part, on an arithmetic product of a predetermined roughness value and a predetermined slope-related value. The predetermined roughness value and slope-related values are predetermined based, at least in part, on measurements of a previously manufactured object. The system sinters a metal to form the top surface of the object to be manufactured. An infrared sensor detects radiation from at least a portion of the top surface of the object to be manufactured. A temperature is generated based, at least in part, on the detected infrared radiation and the emissivity value and the generated temperature is applied to a temperature utilization component of the system.

Taylor, Samantha↗

Diffraction effects on infrared-system performance

An expression for the incidence detected by an ideal quantum detector is derived using incoherent imaging of square waves with one wavelength or in a wavelength band. The detected incidence contains a correction term that becomes appreciable when the width of the square waves becomes comparable in size to the F-number of the imaging system. The correction term is evaluated for a Lambertian self-radiating body with stripes at two temperatures. The quality of the detected image is shown to depend on the temperatures and the dimensions of the body, the wavelength band of the detection system, and the F-number of the imaging system.

Scholl, Marija S.↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

BioSentinel: Optimizing Growth Conditions for Improved Yeast Cell Viability After Long-Term Desiccation

NASA's BioSentinel mission is one of thirteen secondary payloads to be deployed on the Space Launch System Exploration Mission-1 (SLS EM-1). The BioSentinel nanosatellite will be sent into a heliocentric orbit beyond Low Earth Orbit (LEO), to study the effects of deep space radiation on the budding yeast, Saccharomyces cerevisiae. Ionizing radiation encountered in deep space can create damaging lesions in DNA, including double strand breaks (DSBs). Budding yeast is suitable as a biological model to study these effects, as it is eukaryotic, and can be desiccated for prolonged periods while retaining viability, thus serving as a robust analog for human cells. On the ground, yeast cells are grown in liquid medium, then loaded into the wells of microfluidic cards and air dried prior to integration into the payload. Once the spacecraft reaches its target heliocentric orbit, a mixture of growth medium and metabolic indicator dye will be pumped into the microwells at specific time points to rehydrate the cells and allow them to grow. A 3-color LED detection system will measure changes in growth and metabolism resulting from ionizing radiation exposure. BioSentinel contains a wild type control strain and a rad51 mutant that is defective for DNA damage repair. In this study, we will determine the optimal amount of time to grow diploid yeast cells in liquid culture before they are desiccated for space flight. After an extended time in stationary phase, they become more tolerant to desiccation due to stress caused by nitrogen starvation. However, excessive exposure can lead to loss of viability and to a heterogeneous cell population due to sporulation. Since viability loss during desiccation poses a risk to mission success, a stress preconditioning process during initial growth may increase long-term cell viability. To determine the growth period that improves desiccation tolerance but allows for retention of uniform radiation sensitivity, we will grow both strains in liquid medium for a varying number of days (4 to 7), desiccate the cells, and then observe changes to cell viability and ionizing radiation sensitivity over time. Supported by the Space Life Sciences Training Program at NASA Ames Research Center.

Cui, Kaixin↗

The enigmatic T Tauri radio source

We have analyzed eight high angular resolution images of the prototype low mass pre-main-sequence star T Tauri obtained with the Very Large Array between 1987 and 1990. Our objectives were to confirm a recent report that the radio emission is both variable and circularly polarized, to determine whether this behavior originates in the optical star or in the infrared source lying 0.6 sec to its south, and to identify possible emission mechanisms. No variability or circular polarization was detected in the weak (approximately equals 1 mJy) radio emission associated with the visible star, down to levels of approximately equals 10%. The observed flux can be accounted for by free-free emission from an ionized wind with a mass-loss rate M = 3.7 x 10(exp -8) solar mass yr(exp -1), but a more accurate determination of the spectral index is needed to test the validity of sperical wind models. In sharp contrast, the 3.6 cm emission of the infrared source is variable (approximately equals 4-7 mJy) on time scales less than or equal to 3 days and circularly polarized at low levels of approximately equals 3% - 5%. The polarization was left circular when detected during periods of low radio activity but changed to right circular during a radio outburst, similar to the reversals that have been seen in some RS CVn binary systems. The spectral index is negative during 'quiescence,'and we argue that the emission is nonthermal gyrosynchrotron radiation. The detection of magnetic radio activity in this optically invisible infrared source sparks new interest in clarifying its evolutionary status. Sensitive 3.6 cm images reveal weak emission extending approximately equals 1 sec west of the T Tau system that is probably associated with high-velocity shock-excited gas flowing toward HH-1555. We find no radio evidence for a putative third component north of the visible star.

Skinner, Stephen L.↗

Study of a Proposed Infrared Horizon Scanner for Use in Space-Orientation Control Systems

An attitude-sensing device for space vehicles which detects the thermal radiation discontinuity at opposite horizons of a planetary body to produce an attitude error signal is described. The planetary body may be the Earth, its Moon, Mars, or Venus. The sensor is expected to have an accuracy of 0.25 degrees for the Earth, a long continuous operating lifetime, a wide altitude range, a wide capture capability, and an inherent ability to produce signals indicating vehicle altitude. An experimental model incorporating many of the features of the proposed sensor indicates that the proposed sensor will be low in weight, volume, and power consumption. The sensor's altitude range, accuracy, lifetime, and sensitivity to radiation from the Moon and planets are discussed.

INFRARED HORIZON SCANNER↗

BioSentinel ISS Control Experiment Final Investigation Summary Form

Each payload has 18 fluidic cards and each fluidic card has 16 microfluidic wells, for a total of 288 wells. Card activation occurs at different time points throughout the 6-month mission and following ground commands. At each timepoint, two fluidic cards are filled with growth medium containing nutrients and a metabolic indicator dye. In addition to card filling, the temperature of the cards increases from ~4°C (stasis mode) to 23°C to allow for cell growth. The metabolic dye changes color from blue to pink, then pink to clearin the presence of metabolically active yeast cells. The colorimetric changes and cell growth are monitored using a 3-light-emitting diode(LED)optical detection system. The optical data determines how fast the cells are able to recover after accumulating radiation damage over time.After ground command initiation, all the fluidics, thermal and optical detection steps in BioSentinel are fully automated.The biosensor response data is compared to physical dosimetry data collected onboard the same payload. This dosimeter or linear energy transfer (LET)spectrometer is based on TimePix chip technology. This chip measures the total ionizing radiation dose in addition to calculating the LET of each particle that traverses its sensor, thus allowing researchers to characterize the radiation environment around the payload.The biological response (and physical dosimetry) on ISS over time is compared to the deep space mission and to data obtained on the ground.This analysis provides insight on the biological effects of the space radiation exposure in preparation for future long-duration missions to space and inhabitation beyond low-Earth orbit (LEO).

BioSentinel↗

Observing System Simulation Experiment (OSSE) for the HyspIRI Spectrometer Mission

The OSSE software provides an integrated end-to-end environment to simulate an Earth observing system by iteratively running a distributed modeling workflow based on the HyspIRI Mission, including atmospheric radiative transfer, surface albedo effects, detection, and retrieval for agile exploration of the mission design space. The software enables an Observing System Simulation Experiment (OSSE) and can be used for design trade space exploration of science return for proposed instruments by modeling the whole ground truth, sensing, and retrieval chain and to assess retrieval accuracy for a particular instrument and algorithm design. The OSSE in fra struc ture is extensible to future National Research Council (NRC) Decadal Survey concept missions where integrated modeling can improve the fidelity of coupled science and engineering analyses for systematic analysis and science return studies. This software has a distributed architecture that gives it a distinct advantage over other similar efforts. The workflow modeling components are typically legacy computer programs implemented in a variety of programming languages, including MATLAB, Excel, and FORTRAN. Integration of these diverse components is difficult and time-consuming. In order to hide this complexity, each modeling component is wrapped as a Web Service, and each component is able to pass analysis parameterizations, such as reflectance or radiance spectra, on to the next component downstream in the service workflow chain. In this way, the interface to each modeling component becomes uniform and the entire end-to-end workflow can be run using any existing or custom workflow processing engine. The architecture lets users extend workflows as new modeling components become available, chain together the components using any existing or custom workflow processing engine, and distribute them across any Internet-accessible Web Service endpoints. The workflow components can be hosted on any Internet-accessible machine. This has the advantages that the computations can be distributed to make best use of the available computing resources, and each workflow component can be hosted and maintained by their respective domain experts.

Turmon, Michael J.↗

Real-time gross actinide monitoring in extreme (10 6 :1) beta-gamma background fluid streams using mini-ATMFDs

Real-time, trace alpha activity monitoring in extreme mixed radiation fields is a well-known challenge in fission product-rich streams containing mixtures of beta-gamma-alpha radiation-emitting isotopes, arising due to the extreme 10 6 :1 ratio of background beta-gamma vs. alpha radiation activity levels. This paper presents results from a novel approach to addressing this challenge, based on Tensioned Metastable Fluid Detector (TMFD) sensing technology. An acoustically driven technique was developed and tested at Purdue University (using dissolved Rn-Po and U-chain alpha emitters), and validated (with dissolved Pu) at Savannah River National Laboratory for real-time monitoring of alpha activity in the 100–10,000 dpm/mL range.

Environmental Monitoring↗

Multiplicity counting using organic scintillators to distinguish neutron sources: An advanced teaching laboratory

In this advanced instructional laboratory, students explore complex detection systems and nondestructive assay techniques used in the field of nuclear physics. After setting up and calibrating a neutron detection system, students carry out timing and energy deposition analyses of radiation signals. Through the timing of prompt fission neutron signals, multiplicity counting is used to carry out a special nuclear material (SNM) nondestructive assay. Our experimental setup is comprised of eight trans-stilbene organic scintillation detectors in a well-counter configuration, and measurements are taken on a spontaneous fission source as well as two (α,n) sources. By comparing each source's measured multiplicity distribution, the resulting measurements of the (α,n) sources can be distinguished from that of the spontaneous fission source. Such comparisons prevent the spoofing, i.e., intentional imitation, of a fission source by an (α,n) neutron source. This instructional laboratory is designed for nuclear engineering and physics students interested in organic scintillators, neutron sources, and nonproliferation radiation measurement techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Explorer's Guide to the Universe: A Reading List for Planetary and Space Science

During the last decade, both scientists and the public have been engulfed by a flood of discoveries and information from outer space. Distant worlds have become familiar landscapes. Instruments in space have shown us a different Sun by the "light" of ultraviolet radiation and X-rays. Beyond the solar system, we have detected a strange universe of unsuspected violence, unexplained objects, and unimaginable energies. We are completely remarking our picture of the universe around us, and scientists and the general public alike are curious and excited about what we see. The public has participated in this period of exploration and discovery to an extent never possible before. In real time, TV screens show moonwalks, the sands of Mars, the volcanoes of Io, and the rings of Saturn. But after the initial excitement, it is hard for the curious non-scientist to learn more details or even to stay in touch with what is going on. Each space mission or new discovery is quickly skimmed over by newspapers and TV and then preserved in technical journals that are neither accessible nor easily read by the average reader. This reading list is an attempt to bridge the gap between the people who make discoveries in space and the people who would like to read about them. The aim has been to provide to many different people--teachers, students, scientists, other professionals, and curious citizens of all kinds--a list of readings where they can find out what the universe is like and what we have learned about it. We have included sections on the objects that seem to be of general interest--the Moon, the planets, the Sun, comets, and the universe beyond. We have also included material on related subjects that people are interested in--the history of space exploration, space habitats, extraterrestrial life, and U F O ' s . The list is intended to be self-contained; it includes both general references to supply background and more specific sources for new discoveries. Although the list can be used by a wide range of people, it has been compiled with the non-scientist specifically in mind. A s a general rule, we have not included technical symposia or the special issues of

French, Bevan M.↗

New Astrophysical Discovery with Ground and Space-Based Observatories

Astronomy is robust with discovery thanks to a wide range of international observing facilities in space and on the ground. For example, space telescopes such as Webb and Hubble are now detecting the most distant galaxies in the universe, as well as the cosmological effects of dark matter and dark energy. Ground based radio telescope arrays are peering into nurseries of star-formation, finding regions of infant stars and also their circumstellar disks in which planetary systems are forming. Even black holes have now been imaged. This overview talk will highlight recent advances in observational astrophysics, especially the scientifically powerful examples where multiple facilities are used in complement. Examples include the study of solar system bodies, the characterization of exoplanet atmospheres, and detections of electromagnetic radiation associated with cosmic sources of gravitational waves.

Jennifer J Wiseman↗

An Artificial Neural Network System for Photon-Based Active Interrogation Applications

Active interrogation (AI) is a promising technique to detect shielded special nuclear materials (SNMs). At the University of Michigan, we are developing a photon-based AI system that uses bremsstrahlung radiation from an electron linear accelerator (linac) as an ionizing source and stilbene organic scintillating detectors for neutron detection. Stilbene scintillators are sensitive to fast neutrons and photons and have excellent pulse shape discrimination (PSD) capabilities. The traditional charge integration (CI) method commonly used for PSD analysis eliminates piled-up pulses and relies on a particle discrimination line to separate neutrons and photons. The presence of the intense photon flux during AI creates a significant number of piled-up events in the stilbene scintillator, thereby posing a great challenge to the traditional CI method. Identifying true single neutron pulses becomes challenging due to the presence of a pile-up cloud and overlapping neutron, photon and pile-up clouds in the PSD analysis. To mitigate the effect of pulse pile up and identify true single neutron pulses from stilbene scintillators, an artificial neural network (ANN) system is developed. The developed ANN system identifies single neutron pulses and neutron-photon combinations from piled-up events. The results obtained from a 252Cf measurement in the presence of the intense photon flux show that the developed ANN system outperforms the traditional CI method. Since many piled-up events lie above the particle discrimination line, they get misclassified as neutrons by the traditional CI method resulting in 25% overestimation of the net neutron count rate during the linac pulse. The overall net neutron count rate (single and restored neutrons) during the linac pulse, estimated by the ANN system is 60% of the ground truth. Energy spectroscopy of the ANN attributed single neutron pulses further provides evidence on the detection of prompt fission neutrons from the 252Cf fission source.

42 ENGINEERING↗