Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “process quality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

TU-C-BRE-01: KEYNOTE PRESENTATION - Emerging Frontiers in IMRT QA

As IMRT treatment processes advance and mature, so must the quality assurance processes being used to validate their delivery. In some respects, treatment delivery advancements (e.g. VMAT) have out-paced QA advancements. The purpose of this session is to describe new processes that are being implemented to bring IMRT QA up-to-date with the treatment delivery advances. It would explore emerging IMRT QA paradigms, including requirements-based IMRT QA which necessitates definition of delivery errors (e.g. patient dose error, leaf positioning error) and development of processes to ensure reliable error detection. Engineeringbased QA approaches, including use of IMRT treatment delivery process trees, fault tree analysis and failure modes effects analysis would be described. Approaches to detect errors such as (1) during treatment delivery validation using exit fluence detectors (e.g. EPIDs); (2) analysis of treatment delivery via use of machine parameter log files; (3) dose recalculation using (3a) treatment planning system; (3b) record-and-verify; or (3c) entrance and exit fluence measurement parameters would be explained. The relative advantages and disadvantages of each method would be discussed. Schemes for error classification and root cause analysis would be described – steps which are essential for future error prevention. For each QA method, testing procedures and results would be presented indicating the types of errors that can be detected, those that cannot be detected, and the reliability of the error detection method (for example determined via ROC analysis). For speakers, we are seeking to engage non-commercially biased experts. Those listed below are a sub-sample of possible qualified individuals.

60 APPLIED LIFE SCIENCES↗

Modeling strength and failure variability due to porosity in additively manufactured metals

To model and quantify the variability in plasticity and failure of additively manufactured metals due to imperfections in their microstructure, we have developed uncertainty quantification methodology based on pseudo marginal likelihood and embedded variability techniques. We account for both the porosity resolvable in computed tomography scans of the initial material and the sub-threshold distribution of voids through a physically motivated model. Calibration of the model indicates that the sub-threshold population of defects dominates the yield and failure response. Finally, the technique also allows us to quantify the distribution of material parameters connected to microstructural variability created by the manufacturing process, and, thereby, make assessments of material quality and process control.

36 MATERIALS SCIENCE↗

Barnett Shale Natural Gas, Water Use and Water Quality

This unit process quantifies water use and water quality emissions resulting from the production of natural gas from a Barnett Shale natural gas well. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=1F910889-E06A-4F5A-BCC7-C5833665E894

03 NATURAL GAS↗

Coal Bed Methane Natural Gas, Water Use and Water Quality

This unit process quantifies water use and water quality emissions resulting from the production of natural gas from a Coal Bed Methane (CBM) natural gas well. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=B4A8BD58-1293-424A-8741-6077215F8E39

03 NATURAL GAS↗

Conventional Offshore Natural Gas, Water Use and Water Quality

This unit process quantifies water use and water quality emissions resulting from the production of natural gas from a conventional offshore natural gas well. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=4908A090-F275-4EC0-9DBC-CE899CEDB1E8

03 NATURAL GAS↗

Conventional Onshore Natural Gas, Water Use and Water Quality

This unit process quantifies water use and water quality emissions resulting from the production of natural gas from a conventional onshore natural gas well. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=165BBAC0-4560-474F-8B48-C1148864558E

03 NATURAL GAS↗

Onshore Associated Natural Gas Production, Water Use and Water Quality

This unit process quantifies water use and water quality emissions resulting from the production of natural gas from a conventional onshore associated natural gas well. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=61AE7E9A-D09C-420A-83A1-A8A6E59C8291

03 NATURAL GAS↗

Long-term measurements of ice nucleating particles at Atmospheric Radiation Measurement (ARM) sites worldwide

Ice nucleating particles (INPs) play a critical role in cloud microphysics and precipitation formation, yet long-term, spatially extensive observational datasets remain limited. Here, we present one of the most comprehensive publicly available datasets of immersion-mode INP concentrations using a single analytical method, generated through the U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) user facility. INP filter samples have been collected across a broad range of environments – including agricultural plains, Arctic coastlines, high-elevation mountain sites, marine regions, and urban areas – via fixed observatories, mobile facility deployments, and vertically-resolved tethered balloon system operations. We describe the standardized processing and quality assurance pipeline, from filter collection and processing using the Ice Nucleation Spectrometer to final data products archived on the ARM Data Discovery portal. The dataset includes both total INP concentrations and selectively treated samples, allowing for classification of biological, organic, and inorganic INP types. It features a continuous 5-year record of INP measurements from a central U.S. site, with data collection still ongoing. Seasonal and site-specific differences in INP concentrations are illustrated through intercomparisons at −10 and −20 °C, revealing distinct regional sources and atmospheric drivers. We also outline mechanisms for researchers to access existing data, request additional sample analyses, and propose future field campaigns involving ARM INP measurements. This dataset supports a wide range of scientific applications, from observational and mechanistic studies to model development, and provides critical constraints on aerosol-cloud interactions across diverse atmospheric regimes (Creamean et al., 2024, 2020b; https://doi.org/10.5439/1770816).

Creamean, Jessie M. [Colorado State Univ., Fort Co↗

Defining Golden Batches in Biomanufacturing Processes From Internal Metabolic Activity to Detect Process Changes That May Affect Product Quality

ABSTRACT Cellular metabolism plays a role in the observed variability of a drug substance's Critical Quality Attributes (CQAs) made by biomanufacturing processes. Therefore, here we describe a new approach for monitoring biomanufacturing processes that measures a set of metabolic reaction rates (named Critical Metabolic Parameters (CMP) in addition to the macroscopic process conditions currently being used as Critical Process Parameters (CPP) for biomanufacturing. Constraint‐based systems biology models like Flux Balance Analysis (FBA) are used to estimate metabolic reaction rates, and metabolic rates are used as inputs for multivariate Batch Evolution Models (BEM). Metabolic activity was reproducible among batches and could be monitored to detect a deliberately induced macroscopic process shift (i.e., temperature change). The CMP approach has the potential to enable “golden batches” in biomanufacturing processes to be defined from the internal metabolic activity and to aid in detecting process changes that may impact the quality of the product. Overall, the data suggested that monitoring of metabolic activity has promise for biomanufacturing process control.

Biotechnology & Applied Microbiology↗

A Comprehensive Northern Hemisphere Particle Microphysics Data Set From the Precipitation Imaging Package

Microphysical observations of precipitating particles are critical data sources for numerical weather prediction models and remote sensing retrieval algorithms. However, obtaining coherent data sets of particle microphysics is challenging as they are often unindexed, distributed across disparate institutions, and have not undergone a uniform quality control process. This work introduces a unified, comprehensive Northern Hemisphere particle microphysical data set from the National Aeronautics and Space Administration precipitation imaging package (PIP), accessible in a standardized data format and stored in a centralized, public repository. Data is collected from 10 measurement sites spanning 34° latitude (37°N–71°N) over 10 years (2014–2023), which comprise a set of 1,070,000 precipitating minutes. The provided data set includes measurements of a suite of microphysical attributes for both rain and snow, including distributions of particle size, vertical velocity, and effective density, along with higher-order products including an approximation of volume-weighted equivalent particle densities, liquid equivalent snowfall, and rainfall rate estimates. The data underwent a rigorous standardization and quality assurance process to filter out erroneous observations to produce a self-describing, scalable, and achievable data set. Case study analyses demonstrate the capabilities of the data set in identifying physical processes like precipitation phase-changes at high temporal resolution. Bulk precipitation characteristics from a multi-site intercomparison also highlight distinct microphysical properties unique to each location. This curated PIP data set is a robust database of high-quality particle microphysical observations for constraining future precipitation retrieval algorithms, and offers new insights toward better understanding regional and seasonal differences in bulk precipitation characteristics.

54 ENVIRONMENTAL SCIENCES↗

Validation of software releases for CMS

The CMS software stack currently consists of more than 2 Million lines of code developed by over 250 authors with a new version being released every week. CMS has setup a release validation process for quality assurance which enables the developers to compare to previous releases and references. This process provides the developers with reconstructed datasets of real data and MC samples. The samples span the whole range of detector effects and important physics signatures to benchmark the performance of the software. They are used to investigate interdependency effects of software packages and to find and fix bugs. The samples have to be available in a very short time after a release is published to fit into the streamlined CMS development cycle. The standard CMS processing infrastructure and dedicated resources at CERN and FNAL are used to achieve a very short turnaround of 24 hours. The here described release validation process is an integral part of CMS software development and contributes significantly to ensure stable production and analysis. It's success emphasizes the importance of a streamlined release validation process for projects with a large code basis and significant number of developers and can function as an example for future projects.

99 GENERAL AND MISCELLANEOUS↗

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part II. High dose rate {sup 192}Ir sources

Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR){sup 192}Ir sources, as well as electronic brachytherapy sources. Part I of this paper discussed the applicators used with electronic brachytherapy sources. Part II will discuss those used with HDR {sup 192}Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Methods: This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and{sup 192}Ir sources (Part II). Air-kerma rate measurements for the {sup 192}Ir sources were completed with several models of small-volume ionization chambers to obtain an air-kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator-specific absorbed dose to water at the treatment surface from the measured air-kerma rate. Additionally, relative dose measurements of the surface dose distributions and characteristic depth dose curves were completed in-phantom. Results: Theoretical dose distributions and depth dose curves were generated for each applicator and agreed well with the measured values. A method of output verification was created that allows users to determine the applicator-specific dose to water at the treatment surface based on a measured air-kerma rate. Conclusions: The novel output verification methods described in this work will reduce uncertainties in dose delivery for treatments with these kinds of surface applicators, ultimately improving patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source

Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR){sup 192}Ir sources, as well as electronic brachytherapy sources. Part I of this paper will discuss the applicators used with electronic brachytherapy sources; Part II will discuss those used with HDR {sup 192}Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics including depth dose and surface dose distributions have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Existing dosimetry protocols available from the AAPM bookend the cross-over characteristics of a traditional brachytherapy source (as described by Task Group 43) being implemented as a low-energy superficial x-ray beam (as described by Task Group 61) as observed with the surface applicators of interest. Methods: This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and{sup 192}Ir sources (Part II). Air-kerma rate measurements for the electronic brachytherapy sources were completed with an Attix Free-Air Chamber, as well as several models of small-volume ionization chambers to obtain an air-kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator-specific absorbed dose to water at the treatment surface from the measured air-kerma rate. Additionally, relative dose measurements of the surface dose distributions and characteristic depth dose curves were completed in-phantom. Results: Theoretical dose distributions and depth dose curves were generated for each applicator and agreed well with the measured values. A method of output verification was created that allows users to determine the applicator-specific dose to water at the treatment surface based on a measured air-kerma rate. Conclusions: The novel output verification methods described in this work will reduce uncertainties in dose delivery for treatments with these kinds of surface applicators, ultimately improving patient care.

61 RADIATION PROTECTION AND DOSIMETRY↗

The case for digital twins in metal additive manufacturing

The digital twin (DT) is a relatively new concept that is finding increased acceptance in industry. A DT is generally considered as comprising a physical entity, its virtual replica, and two-way digital data communications in-between. Its primary purpose is to leverage the process intelligence captured within digital models—or usually their faster-solving surrogates—towards generating increased value from the physical entities. The surrogate models are created using machine learning based on data obtained from the field, experiments and digital models, which may be physics-based or statistics-based. Anomaly detection and correction, and diagnostic closed-loop process control are examples of how a process DT can be deployed. In the manufacturing industry, its use can achieve improvements in product quality and process productivity. Metal additive manufacturing (AM) stands to gain tremendously from the use of DTs. This is because the AM process is inherently chaotic, resulting in poor repeatability. However, a DT acting in a supervisory role can inject certainty into the process by actively keeping it within bounds through real-time control commands. Closed-loop feedforward control is achieved by observing the process through sensors that monitor critical parameters and, if there are any deviations from their respective optimal ranges, suitable corrective actions are triggered. The type of corrective action (e.g. a change in laser power or a modification to the scanning speed) and its magnitude are determined by interrogating the surrogate models. Because of their artificial intelligence (AI)-endowed predictive capabilities, which allow them to foresee a future state of the physical twin (e.g. the AM process), DTs proactively take context-sensitive preventative steps, whereas traditional closed-loop feedback control is usually reactive. Apart from assisting a build process in real-time, a DT can help with planning the build of a part by pinpointing the optimum processing window relevant to the desired outcome. Again, the surrogate models are consulted to obtain the required information. In this article, we explain how the application of DTs to the metal AM process can significantly widen its application space by making the process more repeatable (through quality assurance) and cheaper (by getting builds right the first time).

36 MATERIALS SCIENCE↗

Failure mode and effects analysis based risk profile assessment for stereotactic radiosurgery programs at three cancer centers in Brazil

Purpose: The goal of this study was to evaluate the safety and quality management program for stereotactic radiosurgery (SRS) treatment processes at three radiotherapy centers in Brazil by using three industrial engineering tools (1) process mapping, (2) failure modes and effects analysis (FMEA), and (3) fault tree analysis. Methods: The recommendations of Task Group 100 of American Association of Physicists in Medicine were followed to apply the three tools described above to create a process tree for SRS procedure for each radiotherapy center and then FMEA was performed. Failure modes were identified for all process steps and values of risk priority number (RPN) were calculated from O, S, and D (RPN = O × S × D) values assigned by a professional team responsible for patient care. Results: The subprocess treatment planning was presented with the highest number of failure modes for all centers. The total number of failure modes were 135, 104, and 131 for centers I, II, and III, respectively. The highest RPN value for each center is as follows: center I (204), center II (372), and center III (370). Failure modes with RPN ≥ 100: center I (22), center II (115), and center III (110). Failure modes characterized by S ≥ 7, represented 68% of the failure modes for center III, 62% for center II, and 45% for center I. Failure modes with RPNs values ≥100 and S ≥ 7, D ≥ 5, and O ≥ 5 were considered as high priority in this study. Conclusions: The results of the present study show that the safety risk profiles for the same stereotactic radiotherapy process are different at three radiotherapy centers in Brazil. Although this is the same treatment process, this present study showed that the risk priority is different and it will lead to implementation of different safety interventions among the centers. Therefore, the current practice of applying universal device-centric QA is not adequate to address all possible failures in clinical processes at different radiotherapy centers. Integrated approaches to device-centric and process specific quality management program specific to each radiotherapy center are the key to a safe quality management program.

61 RADIATION PROTECTION AND DOSIMETRY↗