Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision cleaning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Precise Synthesis of Complex Si–Si Molecular Frameworks

In this Perspective, we highlight the emergence of target-oriented syntheses of complex molecules composed of Si–Si (oligosilanes) rather than C–C bonds. Saturated oligosilanes structurally resemble alkanes with respect to a tetrahedral geometry, a preference for a staggered conformation in linear chains, the ability to form stable small rings, and tetrahedral stereochemistry at asymmetrically functionalized Si centers. There are also critical differences, for example, differences in multiple bonding and the ability to form penta- and hexacoordinated structures, that mean that chemical reactivity and, in particular, rules for stereoselective synthesis do not cleanly translate from carbon to silicon. This Perspective will discuss recent achievements in the precise, controlled synthesis of complex molecules comprised mainly of Si–Si bonds and highlight the mechanistic insights enabling increased molecular complexity. New tools, such as electrochemical and catalytic reactions, will be discussed as well as the problem of controlling relative configuration in molecules containing multiple stereogenic-at-silicon centers. Furthermore, these synthetic achievements facilitate the discovery of new properties, including insight into light absorption, conformation, and mechanical properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magnetically suspended stepping motors for clean room and vacuum environments

To answer the growing needs for super-clean or contact free actuators for uses in clean rooms, vacuum chambers, and space, innovative actuators which combine the functions of stepping motors and magnetic bearings in one body were developed. The rotor of the magnetically suspended stepping motor is suspended like a magnetic bearing and rotated and positioned like a stepping motor. The important trait of the motor is that it is not a simple mixture or combination of a stepping motor and conventional magnetic bearing, but an amalgam of a stepping motor and a magnetic bearing. Owing to optimal design and feed-back control, a toothed stator and rotor are all that are needed structurewise for stable suspension. More than ten types of motors such as linear type, high accuracy rotary type, two-dimensional type, and high vacuum type were built and tested. This paper describes the structure and design of these motors and their performance for such applications as precise positioning rotary table, linear conveyor system, and theta-zeta positioner for clean room and high vacuum use.

Higuchi, Toshiro↗

Cleaning Study of Genesis Sample 60487

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind were stopped in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. Particles of Genesis wafers, brine from the Utah Testing Range and an organic film have deleterious effects on many of the high-resolution instruments that have been developed to analyze the implanted solar wind. We have conducted a correlative microscopic study of the efficacy of cleaning Genesis samples with megasonically activated ultrapure water and UV/ozone cleaning. Sample 60487, the study sample, is a piece of float-zone silicon from the B/C array approximately 4.995mm x 4.145 mm in size

Kuhlman, Kim R.↗

Designing polymeric membranes with coordination chemistry for high-precision ion separations

State-of-the-art polymeric membranes are unable to perform the high-precision ion separations needed for technologies essential to a circular economy and clean energy future. Coordinative interactions are a mechanism to increase sorption of a target species into a membrane, but the effects of these interactions on membrane permeability and selectivity are poorly understood. We use a multilayered polymer membrane to assess how ion-membrane binding energies affect membrane permeability of similarly sized cations: Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , and Mg 2+ . We report that metals with higher binding energy to iminodiacetate groups of the polymer more selectively permeate through the membrane in multisalt solutions than single-salt solutions. In contrast, weaker binding species are precluded from diffusing into the polymer membrane, which leads to passage proportional to binding energy and independent of membrane thickness. Our findings demonstrate that selectivity of polymeric membranes can markedly increase by tailoring ion-membrane binding energy and minimizing membrane thickness.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon Monoxide Analyzer (CO-ANALYZER) Instrument Handbook

The N 2 O/CO analyzer uses LGR’s patented Off-axis ICOS technology, which employs a high-finesse optical cavity as the measurement cell. LGR’s technology has many proven advantages over conventional first-generation cavity ringdown spectroscopy (CRDS) techniques. In brief, since the laser beam does not have to be resonantly coupled to the measurement cell, precise beam alignment is not critical. Mentors can disassemble the cell for cleaning (CAREFULLY) the front surface mirrors. Analyzers are relatively inexpensive and inherently robust thermally and mechanically. In addition, since LGR’s technology can record reliable absorption spectra over a far wider range of optical depths (absorbance values) than CRDS, LGR analyzers provide measurements over a much wider range of mixing ratios (gas concentrations). The N 2 O/CO analyzer includes an internal computer that sends real-time data to the local instrument computer through its digital (RS-232) output.

47 OTHER INSTRUMENTATION↗

aosco (01)

As of 5 August, 2015, Los Gatos Research (LGR) CO/H2O/N2O analyzer instruments (COANALYZERs) were deployed in the Atmospheric Radiation Measurement (ARM) Aerial Facility (AAF), the third ARM Mobile Facility (AMF3) Aerosol Observing System (AOS), Eastern North Atlantic (ENA) AOS, and Mobile AOS (MAOS-C). The N2O/CO analyzer uses LGR’s patented Off-axis ICOS technology, which employs a high-finesse optical cavity as the measurement cell. LGR’s technology has many proven advantages over conventional first-generation cavity ringdown spectroscopy (CRDS) techniques. In brief, since the laser beam does not have to be resonantly coupled to the measurement cell, precise beam alignment is not critical. Mentors can disassemble the cell for cleaning (CAREFULLY) the front surface mirrors. Analyzers are relatively inexpensive and inherently robust thermally and mechanically. In addition, since LGR’s technology can record reliable absorption spectra over a far wider range of optical depths (absorbance values) than CRDS, LGR analyzers provide measurements over a much wider range of mixing ratios (gas concentrations). The N2O/CO analyzer includes an internal computer that sends real-time data to the local instrument computer through its digital (RS-232) output.

54 ENVIRONMENTAL SCIENCES↗

Isotopic, Chemical and Mineralogical Investigations of Extraterrestrial Materials

The principal aim of our work was to improve our understanding of the earliest evolutionary period of our solar system (i.e. the first tens of millions of years). We have studied its chronology by using short and long term chronometers (based on extinct and long lived radioactive nuclei), explored the bearing of short lived nuclei on planetary heating and differentiation, and the addition of 'exotic' nuclei to solar system matter to help constrain models of nucleosynthesis. Our basic tool is high precision Thermal Ionization Mass Spectrometry (TIMS). Over the years we have developed clean chemical separation procedures for many elements. The chemical elements most relevant to our investigations are Cr, Ni, Rb, Sr, Sm, Nd, Pb, and U, for which highly efficient measurement techniques by TIMS have been developed and have been in use in our laboratory for many years. We have explored the Mn-53 Cr-53 system (T (Mn-53) = 3.7 Ma) and have found it to be a powerful tool to obtain relative ages of meteorite formation and, more general, of early solar system processes with a time resolution of approx. 1 Ma. By measuring the Mn-Cr system in many meteorite types (chondrites, basaltic achondrites, angrites, pallasites, etc.) we have found that this condition is indeed met for most meteorite families.

Lugmair, Guenter W.↗

The miniJPAS survey: White dwarf science with 56 optical filters

We analyze the white dwarf population in miniJPAS, the first square degree observed with 56 medium-band, 145 Å in width optical filters by the Javalambre Physics of the accelerating Universe Astrophysical Survey (J-PAS), to provide a data-based forecast for the white dwarf science with low-resolution ($R$ ~ 50) photo-spectra. We define the sample of the bluest point-like sources in miniJPAS with $r$ < 21.5 mag, a point-like probability larger than 0.5, ($u$ - $r$)< 0.80 mag, and ($g$ - $i$)< 0.25 mag. This sample comprises 33 sources with spectroscopic information: 11 white dwarfs and 22 quasi-stellar objects (QSOs). We estimate the effective temperature ($T$ eff ), the surface gravity, and the composition of the white dwarf population by a Bayesian fitting to the observed photo-spectra. The miniJPAS data are sensitive to the Balmer series and the presence of polluting metals. Our results, combined with those from the Javalambre Photometric Local Universe Survey (J-PLUS) which has a lower spectral resolution but has already observed thousands of white dwarfs, suggest that J-PAS photometry would permit – down to $r$ ~ 21.5 mag and at least for sources with 7000 < $T$ eff < 22 000 K – both the classification of the observed white dwarfs into H-dominated and He-dominated with 99% confidence and the detection of calcium absorption for equivalent widths larger than 15 Å. The effective temperature is estimated with a 2% uncertainty, which is close to the 1% from spectroscopy. A precise estimation of the surface gravity depends on the available parallax information. In addition, the white dwarf population at $T$ eff > 7000 K can be segregated from the bluest extragalactic QSOs, providing a clean sample based on optical photometry alone. The J-PAS low-resolution photo-spectra would produce precise effective temperatures and atmospheric compositions for white dwarfs, complementing the data from Gaia. J-PAS will also detect and characterize new white dwarfs beyond the Gaia magnitude limit, providing faint candidates for spectroscopic follow-up.

79 ASTRONOMY AND ASTROPHYSICS↗

New Precision Measurements of Deuteron Structure Function A(Q) at Low Momentum Transfer

Differences between previous measurements of low momentum transfer electron-deuteron elastic scattering prevent a clean determination of even the sign of the leading low momentum transfer relativistic corrections, or of the convergence of chiral perturbation theory. We have attempted to resolve this issue with a new high-precision measurement in Jefferson Lab Hall A. Elastic electron scattering was measured on targets of tantalum, carbon, hydrogen, and deuterium at beam energy of 685 MeV. The four-momentum transfer covered the range of 0.15 - 0.7 GeV. The experiment included a new beam calorimeter, to better calibrate the low beam currents used in the experiment, and new collimators to better define the spectrometer solid angles. We obtained cross sections of deuteron as ratios to hydrogen cross sections. A fit function of B(Q) world data is newly made and subtracted from cross sections to find values of A(Q).

08 HYDROGEN↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

Production, quality assurance and quality control of the SiPM Tiles for the DarkSide-20k Time Projection Chamber

The DarkSide-20k dark matter direct detection experiment will employ a 21 m 2 silicon photomultiplier (SiPM) array, instrumenting a dual-phase 50 tonnes liquid argon Time Projection Chamber (TPC). SiPMs are arranged into modular photosensors called Tiles, each integrating 24 SiPMs onto a printed circuit board (PCB) that provides signal amplification, power distribution, and a single-ended output for simplified readout. Tiles are further grouped into Photo-Detector Units (PDUs). This paper details the production of the Tiles and the Quality Assurance and Quality Control (QA-QC) protocol established to ensure their performance and uniformity. The production and QA-QC of the Tiles are carried out at Nuova Officina Assergi (NOA), an ISO-6 clean room facility at LNGS. This process includes wafer-level cryogenic characterisation, precision die attaching, wire bonding, and extensive electrical and optical validation of each Tile. The overall production yield exceeds 83.5%, matching the requirements of the DarkSide-20k production plan. These results validate the robustness of the Tile design and its suitability for operation in a cryogenic environment.

Acerbi, F. [Fondazione Bruno Kessler]↗

Cellulose Acetate Replica Cleaning Study of Genesis Non-Flight Sample 3CZ00327

The Genesis mission collected solar wind and brought it back to Earth in order to provide precise knowledge of solar isotopic and elemental compositions. The ions in the solar wind were stopped in the collectors at depths on the order of 10 to a few hundred nanometers. This shallow implantation layer is critical for scientific analysis of the composition of the solar wind and must be preserved throughout sample handling, cleaning, processing, distribution, preparation and analysis. We are working interactively with the community of scientists analyzing Genesis samples, using our unique laboratory facilities -- and, where needed, our unique cleaning techniques -- to significantly enhance the science return from the Genesis mission. This work is motivated by the need to understand the submicron contamination on the collectors in the Genesis payload as recovered from the crash site in the Utah desert, and -- perhaps more importantly -- how to remove it. That is, we are evaluating the effectiveness of the wet-chemical "cleaning" steps used by various investigators, to enable them to design improved methods of stripping terrestrial contamination from surfaces while still leaving the solar-wind signal intact.

Kuhlman, K. R.↗

Muon Collider Forum report

A multi-TeV muon collider offers a spectacular opportunity in the direct exploration of the energy frontier. Offering a combination of unprecedented energy collisions in a comparatively clean leptonic environment, a high energy muon collider has the unique potential to provide both precision measurements and the highest energy reach in one machine that cannot be paralleled by any currently available technology. The topic generated a lot of excitement in Snowmass meetings and continues to attract a large number of supporters, including many from the early career community. In light of this very strong interest within the US particle physics community, Snowmass Energy, Theory and Accelerator Frontiers created a cross-frontier Muon Collider Forum in November of 2020. The Forum has been meeting on a monthly basis and organized several topical workshops dedicated to physics, accelerator technology, and detector R&D. Findings of the Forum are summarized in this report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-precision Measurement of the 16 O($n, n'γ$) Cross Section using $γ$-ray Detection in Liquid Scintillators with H 2 O and BeO Targets

The 16 O($n, n'γ$) reaction was measured at the Los Alamos Neutron Science Center white neutron source using γ-ray detection in liquid scintillators present in the upper hemisphere of the Correlated Gamma-Neutron Array for sCattering (CoGNAC). Separate measurements of this reaction were performed using H 2 O and BeO targets in successive years. The unique high energies of γ rays emitted from the 16 O($n, n'γ$) reaction facilitated a clean selection of this reaction from threshold to 9.8 MeV incident neutron energy without the need for precise measurements of the γ-ray energy or the scattered neutrons. The precise time resolution of the liquid scintillator detectors was then exploited to obtain high-resolution incident neutron energy measurements, and good agreement was obtained between the H 2 O and BeO results reported here. The dominant literature data sets for this reaction have systematic differences between them, but the present results improve upon the neutron energy resolution of earlier measurements and show important discrepancies in recent data. Finally, tentative data are also shown up to 20 MeV incident neutron energy but are potentially subject to improved understanding of the relative γ-ray and α decay branches from 16 O excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring Signatures of Fuel Irradiation in Large Particle Samples

Understanding the operating history of a nuclear facility is one of the key goals in nuclear safeguards, enabling the verification of declared activities. This is accomplished via a number of mechanisms, including the analysis of samples collected at the facility. The best metrics for understanding and verifying the history of nuclear fuel are (1) actinide isotopic content and (2) actinide inter-element ratios. While techniques have long existed for measuring these values with high accuracy and precision in bulk samples, as samples become smaller – such as may be collected in environmental collection – new methods are required both for clean processing of pure samples, and for analysis of these small samples. This study describes a new extraction chromatography technique for recovering U, Pu, and Am from single small aliquots, and advanced mass spectrometry methods for high-precision and high-accuracy analysis of trace and ultra-trace levels of actinides. These techniques are applied to particle samples cut from fuel from a historic nuclear reactor. Ages calculated from Pu–Am chronometry of particles are in excellent agreement with the known operating history of the reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rotationally resolved state-to-state photoionization and photoelectron study of titanium carbide and its cation (TiC/TiC{sup +})

Titanium carbide and its cation (TiC/TiC{sup +}) have been investigated by the two-color visible (VIS)-ultraviolet (UV) resonance-enhanced photoionization and pulsed field ionization-photoelectron (PFI-PE) methods. Two visible excitation bands for neutral TiC are observed at 16 446 and 16 930 cm{sup −1}. Based on rotational analyses, these bands are assigned as the respective TiC({sup 3}Π{sub 1}) ← TiC(X{sup 3}Σ{sup +}) and TiC({sup 3}Σ{sup +}) ← TiC(X{sup 3}Σ{sup +}) transition bands. This assignment supports that the electronic configuration and term symmetry for the neutral TiC ground state are …7σ{sup 2}8σ{sup 1}9σ{sup 1}3π{sup 4} (X{sup 3}Σ{sup +}). The rotational constant and the corresponding bond distance of TiC(X{sup 3}Σ{sup +}; v″ = 0) are determined to be B{sub 0}″ = 0.6112(10) cm{sup −1} and r{sub 0}″ = 1.695(2) Å, respectively. The rotational analyses of the VIS-UV-PFI-PE spectra for the TiC{sup +}(X; v{sup +} = 0 and 1) vibrational bands show that the electronic configuration and term symmetry for the ionic TiC{sup +} ground state are …7σ{sup 2}8σ{sup 1}3π{sup 4} (X{sup 2}Σ{sup +}) with the v{sup +} = 0 → 1 vibrational spacing of 870.0(8) cm{sup −1} and the rotational constants of B{sub e}{sup +} = 0.6322(28) cm{sup −1}, and α{sub e}{sup +} = 0.0085(28) cm{sup −1}. The latter rotational constants yield the equilibrium bond distance of r{sub e}{sup +} = 1.667(4) Å for TiC{sup +}(X{sup 2}Σ{sup +}). The cleanly rotationally resolved VIS-UV-PFI-PE spectra have also provided a highly precise value of 53 200.2(8) cm{sup −1} [6.5960(1) eV] for the adiabatic ionization energy (IE) of TiC. This IE(TiC) value along with the known IE(Ti) has made possible the determination of the difference between the 0 K bond dissociation energy (D{sub 0}) of TiC{sup +}(X{sup 2}Σ{sup +}) and that of TiC(X{sup 3}Σ{sup +}) to be D{sub 0}(Ti{sup +}−C) − D{sub 0}(Ti−C) = 0.2322(2) eV. Similar to previous experimental observations, the present state-to-state PFI-PE study of the photoionization transitions, TiC{sup +}(X{sup 2}Σ{sup +}; v{sup +} = 0 and 1, N{sup +}) ← TiC({sup 3}Π{sub 1}; v′, J′), reveals a strong decreasing trend for the photoionization cross section as |ΔN{sup +}| = |N{sup +} – J′| is increased. The maximum |ΔN{sup +}| change of 7 observed here is also consistent with the previous experimental results for the 3d transition-metal carbides, oxides, and nitrides. However, the VIS-UV-PFI-PE spectra for TiC{sup +}(X{sup 2}Σ{sup +}; v{sup +} = 0 and 1, N{sup +}) are found to display only the negative ΔN{sup +} (N{sup +}–J′≤ 0) transitions, indicating that the cross sections for the formation of positive ΔN{sup +} (N{sup +}–J′ > 0) transitions by both the channel coupling mechanism and direct photoionization are negligibly small.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gluino reach and mass extraction at the LHC in radiatively-driven natural SUSY

Radiatively-driven natural SUSY (RNS) models enjoy electroweak naturalness at the 10% level while respecting LHC sparticle and Higgs mass constraints. Gluino and top-squark masses can range up to several TeV (with other squarks even heavier) but a set of light Higgsinos are required with mass not too far above mh ~ 125 GeV. Within the RNS framework, gluinos dominantly decay via g˜ → tt ˜* 1 , t ¯t ˜ 1 → tt ¯Z 1,2 or tb¯W- 1 + c.c., where the decay products of the higgsino-like W ~ 1 and Z ~ 2 are very soft. Gluino pair production is, therefore, signaled by events with up to four hard b-jets and large E T . We devise a set of cuts to isolate a relatively pure gluino sample at the (high-luminosity) LHC and show that in the RNS model with very heavy squarks, the gluino signal will be accessible for m g ˜ < 2400 (2800) GeV for an integrated luminosity of 300 (3000) fb -1 . We also show that the measurement of the rate of gluino events in the clean sample mentioned above allows for a determination of m g ˜ with a statistical precision of 2–5% (depending on the integrated luminosity and the gluino mass) over the range of gluino masses where a 5σ discovery is possible at the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring Bearing Wear Via Weight Loss

Wear in critical parts of bearings measured via amounts of weight lost during use. Technique applicable in general to bearings made of nonporous materials. Weight-loss measurements easier, faster, more precise, and less likely to damage measured parts. Weight-loss measurements performed in clean rooms and under constraint of extreme cleanliness for compatability with liquid oxygen.

Keba, John E.↗