Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power outage impacts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High Reliability Requires More than Providing Spares

It is sometimes optimistically hoped that a space life support system can be kept working throughout a long duration mission by repairing failed components, as long as sufficient spares are flown. It is usually assumed that the components have constant known failure rates. Then the needed numbers of spares can be computed to have any particular probability that all failed components can be replaced by available spares. This approach can provide high reliability if its favorable assumptions, including constant known failure rates, are satisfied. Other favorable assumptions are that the failures are statistically independent, repair will be successful without causing further failures, and all failures are due to internal component failures. These assumptions are not usually justified. The failure rates may be estimates that are inadequately verified because of insufficient testing. Failure rates may change due to materials substitutions, manufacturing changes, redesigns to fix failures, and new failures caused by redesigns. Failures that are not statistically independent may result from one common cause, such as a design or manufacturing error or a cascade of cause and effect, possibly caused by an external event such as a power outage. Repair may be unsuccessful or cause damage. Many failures occur at component interfaces or at the overall systems level, not within isolated components. Other failures causes are completely external to the system, due to assembly, maintenance, and operational errors or to unexpected environmental challenges. Replacement with sufficient spares can compensate for expected internal component failures but may not be able to cope with unpredictable design and manufacturing flaws, human errors, and environmental impacts. Reliability estimates based on providing sufficient spares to compensate for expected failures may be far too high. They are essentially upper bounds on reliability that might be approached if many frequent but often unconsidered failure causes can be eliminated.

spares↗

Critical values of cyber parameters in a dynamic microgrid system

An islanded microgrid can be used to serve critcal load as a resiliency source when a severe outage occurs. In an islanded mode, control of a microgrid relies on the communication system significantly. Hence, microgrids are cyberphysical systems and, therefore, the cyber system plays a crucial role in the performance of the cyber-power system. A microgrid control scheme is proposed for power dispatch and regulation based on the droop and proportional-integral (PI) feedback control. The proposed control strategy is validated for transient stability following dynamic events. To evaluate the impact of a networked control system on control performance, a cyber model is developed to represent data acquisition periods and communication delays. An analytical method is proposed to determine the critical values for the data reporting periods and communication delays. The analytical method based on a state space model of a networked control system is applicable for large-scale systems. A 2-dimensional stability region of a microgrid in the space of cyber parameters can be obtained by the proposed method, and the critical values of cyber parameters are determined based on the stability region. Simulation results validate that the design of a microgrid as a cyber-physical system needs to be guided by critical values for the data reporting period and communication delay to prevent system instability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliability of emergency and standby diesel generators: Impact on energy resiliency solutions

Emergency diesel generators are the most common form of backup power for critical loads when the grid fails and are most often deployed as stand-alone generators (<2000 kW) tied to individual buildings for hospitals, emergency services, military bases, ports, airports, industries, and commercial facilities. Understanding the finite reliability of emergency diesel generators during continuous operation is critical for energy planners, managers, and end-users. A new analysis of two large non-public emergency diesel generator operational data sets shows that commonly used reliability metrics are inadequate to predict the performance during a grid outage. Additional metrics addressing the likelihood of an emergency diesel generator to be available at the time an outage starts, successfully start and carry load, and constantly run for the duration of the outage are needed to predict the continuous run-time reliability of emergency diesel generators during a grid outage. This is the first analysis of the reliability of modern generators that follow standard maintenance protocols commonly used for backup power and these new metrics are shown to be dependent on the level of emergency diesel generator maintenance with values that can vary by more than an order of magnitude. Even using the new metrics for well-maintained emergency diesel generators, the analysis shows that the single emergency diesel generators configurations are only 80% likely to provide power for the duration of a two-week grid outage.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

Investigating the effects of cooperative transmission expansion planning on grid performance during heat waves with varying spatial scales

There is growing recognition of the advantages of interregional transmission capacity to decarbonize electricity grids. A less explored benefit is potential performance improvements during extreme weather events. This study examines the impacts of cooperative transmission expansion planning using an advanced modeling chain to simulate power grid operations of the United States Western Interconnection in 2019 and 2059 under different levels of collaboration between transmission planning regions. Two historical heat waves in 2019 with varying geographical coverage are replayed under future climate change in 2059 to assess the transmission cooperation benefits during grid stress. The results show that cooperative transmission planning yields the best outcomes in terms of reducing wholesale electricity prices and minimizing energy outages both for the whole interconnection and individual transmission planning regions. Compared to individual planning, cooperative planning reduces wholesale electricity prices by 64.3 % and interconnection-wide total costs (transmission investments + grid operations) by 34.6 % in 2059. It also helps decrease greenhouse gas emissions by increasing renewable energy utilization. However, the benefits of cooperation diminish during the widespread heat wave when all regions face extreme electricity demand due to higher space cooling needs. Despite this, cooperative transmission planning remains advantageous, particularly for California Independent System Operator with significant diurnal solar generation capacity. This study suggests that cooperation in transmission planning is crucial for reducing costs and increasing reliability both during normal periods and extreme weather events. It highlights the importance of optimizing the strategic investments to mitigate challenges posed by wider-scale extreme weather events of the future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Putting Safety in the Software

Software is a vital component of nearly every piece of modern technology. It is not a 'sub-system', able to be separated out from the system as a whole, but a 'co-system' that controls, manipulates, or interacts with the hardware and with the end user. Software has its fingers into all the pieces of the pie. If that 'pie', the system, can lead to injury, death, loss of major equipment, or impact your business bottom line, then software safety becomes vitally important. Learning to think about software from a safety perspective is the focus of this paper. We want you to think of software as part of the safety critical system, a major part. This requires 'system thinking' - being able to grasp the whole picture. Software's contribution to modern technology is both good and potentially bad. Software allows more complex and useful devices to be built. It can also contribute to plane crashes and power outages. We want you to see software in a whole new light, see it as a contributor to system hazards, and also as a possible fix or mitigation to some of those hazards.

Wetherholt, Martha S.↗

Resilience Assessment Framework For Electric Distribution Systems Performance Under Extreme Conditions

The devastating impact of extreme weather-related events is increasingly evident on power grids, especially on distribution grids. The severity of their potential impact calls for 1) developing a suitable resilience assessment framework to capture the system performance and 2) assessing relevant mitigative strategies to lessen the impact of such events. This paper proposes a framework to identify grid vulnerabilities using the energy-at-risk concept to select, disconnect and isolate grid portions due to a resilience event. The proposed framework mainly consists of two steps; i) processing the utility's available infrastructure, i.e., a network model, possible switching combinations, and outage information for those combinations, as a graph-based database, and ii) implementing a novel optimal switching algorithm leveraging database and grid simulated metrics. These switching actions are generated to implement load curtailment in a rolling manner during anticipated grid scarcity conditions. In this study, a test case is created using two taxonomy feeders and is simulated against an extreme temperature event, e.g., a long, relatively cold, and prolonged freeze peak, thereby creating stress on the grid. It is demonstrated that the proposed framework allows utilities to predict the energy-at-risk during such resilience events and design suitable outage management strategies.

Poudel, Shiva↗

Cooperation in Transmission Expansion Planning: Enhancing Grid Reliability and Efficiency Under a Changing Climate

Electricity grids are challenged to maintain reliability during more intense and frequent extreme weather events due to climate change. This challenge is exacerbated by multi-sector electrification and power sector decarbonization through increased reliance on variable renewable energy, which necessitates the expansion of transmission infrastructure. However, transmission expansion planning is often complicated by intertwined planning authorities and jurisdictions, and allocation of large capital investment needs. These factors cause authorities to manage transmission investments individually (i.e., only/mostly intraregional planning), which can lead to suboptimal transmission networks. This study investigates the potential benefits of cooperative transmission expansion planning (i.e., both intraregional and interregional planning that optimizes transmission investments across the entire physical system). Using sectoral and economic optimization, and machine learning models, it analyzes the impact of different levels of cooperation among transmission planning regions within U.S. Western Interconnection in 2019 and 2059 via an iterative investment process. Furthermore, it examines the effects of future climate change on transmission cooperation by simulating historical heat waves from 2019 under conditions of 2059. The results indicate that cooperative transmission planning leads to lower wholesale electricity prices, decreased energy outages, and reduced greenhouse gas emissions. However, the advantages of collaboration diminish during widespread heat waves, despite remaining beneficial especially for regions like California Independent System Operator with substantial solar installations. The study underscores the importance of transmission cooperation in reducing costs and enhancing reliability, emphasizing the need for strategic investments in storage to address challenges posed by future extreme weather events with varying spatial scales.

Capacity Expansion Model↗

Eastern Interconnection Wide-Area Oscillation Assessment and Study Report

To meet the government mandates such as Renewable Portfolio Standards (RPS), conventional synchronous generators with rotating mass are being displaced by inverter-based resources (IBRs), leading to high penetration of renewable energy sources (RES). As a result, the inherent properties and characteristics of the transformed generation mix may significantly impact the grid behaviour, and it is of paramount significance that the impact and the consequences of the resource mix change is thoroughly understood to adopt measures to maintain reliable grid operations. Of great concern is the inter-area low-frequency oscillation, which usually propagates through a large region and has a system-wide impact. Such oscillations may lead to unnecessary or inadvertent tripping of generators, that may be simply reacting to the oscillation originating from geographically remote sites. Such tripping of generators can lead to cascading outages, system split and load loss events. Over the years, several system-wide oscillation events have been observed across all three North American interconnections. This project titled Wide-area Oscillation Assessment and Trending Study, sponsored by the Office of Electricity (OE) of the Department of Energy (DOE), aims to conduct the required research to capture and investigate the potential changes in wide-area oscillatory performance of the system as a result of resource mix transition. The Pacific Northwest National Laboratory (PNNL) conducted this research and technical staff of Federal Energy Regulatory Commission (FERC) served as advisors to the project. The primary objective of this study is to assess whether there are significant trends in the power system wide-area oscillatory behaviours, as a result of the generation-mix changes due to the increased penetration of RES in the U.S. Eastern Interconnection (EI). The analysis presented in this report can serve as reference for future grid planning and operation of the EI system. This research conducted in this project evaluates the wide-area oscillatory behaviour of the EI, using a model-based approach for potential future resource mixes, and the measurement-based analysis with 21-month phasor measurement unit (PMU) time series. The oscillation modes in EI system along with the impact of the changes of the generation mix on the frequency and damping ratio (DR) of the oscillations have been studied.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Hydropower Plants for Wildfire Resilient Microgrids

The increasing occurrence and severity of wildfires in recent years is severely impacting critical infrastructures, including the power grid, compromising the quality of life and provision of essential services, including electricity. The western parts of the United States, more specifically Washington, Oregon, and California, which are prone to large wildfires, are also rich in hydropower resources. Hydropower resources located close to communities vulnerable to wildfire can be utilized to develop wildfire-resilient microgrids to support critical needs of those communities. Therefore, this paper develops a framework to characterize hydropower plants and evaluate their feasibility to operate in microgrids during wildfire-related outages. In the proposed framework, hydropower plants are characterized using various plant and site attributes and evaluated in terms of capability and performance indicative metrics. A case study is carried out evaluating the Hills Creek hydropower plant located in a wildfire-prone region of Oregon for wildfire-resilient microgrid. The results of steady-state and dynamic simulations show that the hydropower plant is capable of providing the essential microgrid services and powering nearby communities during extended wildfire-related outages.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

Data Analytics Methods to Measure Plant Outage Resilience

Every 18 or 24 months nuclear power plants (depending on plant configuration, pressurized or boiling water reactor respectively) undergo a period of outage where the plant is taken offline and a large number of maintenance and surveillance activities (that cannot be performed while plant is running) are performed in typically 2–3 weeks. Planning of a plant outage is very challenging since all the activities are required to be performed in the shortest amount of time given available resources (typically contractor crews hired for the duration of the outage). Consequently, plant outages can be costly due the actual loss of power generation and crew costs and, because of it, there is a need to maximize resource usage in the outage planning phase and reduce the risk of outage delays. This paper is addressing these needs by providing a set of analytical methods designed to analyze plant outage schedule and identify critical elements based on available resources (time and crews). These methods are based on natural language processing and optimization algorithms. In this respect, two classes of methods have been developed: one that focuses on the time resource and how variability in the time to complete outage tasks may impact outage delays, and one that minimizes the risk of outage delays by integrating available resources to assess when daily activities should be performed.

97 - MATHEMATICS AND COMPUTING↗

Risk Assessment of Rare Events in Probabilistic Power Flow via Hybrid Multi-Surrogate Method

The risks associated with rare events threatening the security of power system operation are of paramount importance to power system planners and operators. To analyze the risks caused by high-impact, low-frequency rare events, an immensely large number of samples are typically required for the Monte-Carlo (MC) method on the high-fidelity power system model to achieve a sufficient accuracy, thereby rendering this approach computationally prohibitive. To handle this problem efficiently, it is desirable to construct a surrogate model for the power system response. However, the straightforward MC sampling of the low-fidelity surrogate can lead to biased results in the low-probability tail regions that are vital to risk assessment. Moreover, a single surrogate is unable to handle the topology uncertainties caused by random branch outages. To overcome these issues, we propose a hybrid multi-surrogate (HMS) method based on the polynomial chaos expansion (PCE) with low-probability tail events reevaluated by the high-fidelity model through a probabilistic analysis. This method improves the computational efficiency of the MC method for rare-event risk assessment by leveraging multi-fidelity models while retaining the desired accuracy. Simulations conducted in three test systems verify the excellent performances of the HMS method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Natural Hazard Forecast Alert Grid Risk System

Weather events cause most power outages. Often, we even get notifications on our phones to take cover or be prepared for an imminent event. If electric grid utilities had a similar warning that also included probable scenarios and the equipment involved, they could prepare and minimize the effects. Idaho National Laboratory had a project with the U.S. Department of Energy’s Cybersecurity, Energy Security, and Emergency Response program to develop a grid alert application that receives messages from the existing emergency alert system, filters and determines components possibly affected by the emergency event, calculates probable scenarios using MASTERRI (Modeling And Simulation for Targeted Reliability and Resilience Improvement). For high-risk events, the application can then send alert links to subscribed electric distribution utility operations staff to allow them to see and evaluate the scenarios and the impact in a web based interactive map tool. This proof of concept application used data from utilities and organizations, such as the international regulatory body North American Electric Reliability Corporation, which have complied historical failure data of elements that comprise the U.S. electric grid. Nominal failure rates are obtained from this data. To make this tool possible, estimated failure rates were calculated for different component types given the alert type, severity, and location. Historic weather-related grid element failures were correlated with historic weather events from the Integrated Public Alert & Warning System. These correlated events and failures are used along with Bayesian updates from the historical norms to provide a modified failure rate for grid elements in the alert areas and calculate probable scenarios. Working with an industry collaborator, actual grid models and data were used for demonstration cases. This report outlines the work performed for this project.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Space Weather: From Solar Origins to Risks and Hazards Evolving in Time

Space Weather is the portion of space physics that has a direct effect onhumankind. Space Weather is an old branch of space physics that originatesback to 1808 with the publication of a paper by the great naturalist Alexandervon Humboldt (Von Humboldt, Ann. Phys. 1808, 29, 425–429),first defining a“Magnetische Ungewitter”or magnetic storm from auroral observations fromhis home in Berlin, Germany. Space Weather is currently experiencing explosivegrowth, because its effects on human technologies have become more andmore diverse. Space Weather is due to the variability of solar processes thatcause interplanetary, magnetospheric, ionospheric, atmospheric and groundlevel effects. Space Weather can at times have strong impacts on technologicalsystems and human health. The threats and risks are not hypothetical, and in theevent of extreme Space Weather events the consequences could be quitesevere for humankind. The purpose of the review is to give a brief overall view ofthe full chain of physical processes responsible for Space Weather risks andhazards, tracing them from solar origins to effects and impacts in interplanetaryspace, in the Earth’s magnetosphere and ionosphere and at the ground. Inaddition, the paper shows that the risks associated with Space Weather have notbeen constant over time; they have evolved as our society becomes more andmore technologically advanced. The paper begins with a brief introduction tothe Carrington event, arguably the greatest geomagnetic storm in recordedhistory. Next, the descriptions of the strongest known Space Weather processesare reviewed, tracing them from their solar origins. The concepts ofgeomagnetic storms and substorms are briefly introduced. The main effects/impacts of Space Weather are also considered, including geomagneticallyinduced currents (GICs) which are thought to cause power outages. Theeffects of radiation on avionics and human health, ionospheric effects andimpacts, and thermosphere effects and satellite drag will also be discussed.Finally, we will discuss the current challenges of Space Weather forecasting andexamine some of the worst-case scenarios.

Natalia Buzulukova↗

Characterization of Operational Performance of Ka-Band Links in Deep Space Network

This paper presents a characterization of performance of 32-GHz Ka-band link in an operational environment. The data come from tracking of Kepler spacecraft by the NASA Deep Space Network (DSN) in the past few years. Ka-band link offers a significant signal-to-noise advantage compared to the more common X- or S-band; however, it is subject to more signal fluctuation caused by the weather. Kepler is the first mission supported by the DSN that solely rely on the higher deep space Ka-band communications link to return its high-rate science data. A well characterization of the operational performance of Kepler would benefit future Ka-band missions, especially for those operating with smaller link margin. The study examines how weather conditions at the DSN facilities (e.g., winds, clouds, rains) affect the received signal, particularly on telemetry data. It addresses questions such as how often the weather affects the link and how much degradation the link could suffer. Among the 22 Ka-band passes in 2012, heavy clouds affected one pass and two passes were impacted by high winds. The adverse weather caused at time as much as 3-dB instantaneous change in the signal to noise ratio (SNR). Estimates of degradation to the SNR as a function of wind speeds are captured based on observations. This study also quantifies the probability distribution of the variation of received signal power. With such information, future missions can better plan their link design. An optimal link design aims for just having enough margin to realize the data return with a targeted probability, with neither having too much margin that it reduces the downlink data rate nor insufficient reserve that causes frequent data outages. The study tries to provide some answers to the questions such as how much does SNR vary from one tracking pass to the next, and what is the cumulative distribution of signal fluctuation. Regarding the signal variation over many tracking passes, we found that the averaged symbol SNR (SSNR) for each pass changed by as much as 4 dB. Some variations were due to geometry such as the changing distance between spacecraft and Earth and different antenna pointing elevations. Other variations seem to be random in nature, reflecting the randomness of operational environments. Some passes were found to be quite stable, with a standard deviation of symbol SNR around 0.25 dB while others had greater variation, up to 1.4 dB. Overall, the cumulative distribution of the symbol SNR reflects that 50% of the fluctuations was less than 0.6 dB, 90% of fluctuation was within 1.6 dB and 95% within 2.2 dB. Some of the challenges in data processing, validation and modeling were captured in this paper. We observed some inconsistent measurements where operational data significantly deviate from a normal expectation. These inconsistent measurements made it hard to develop an accurate and consistent performance model, such as the degradation of signal SNR as a function of high wind. The difficulty was compounded by the fact that there were only a few Ka-band passes observed in high winds.

Pham, Timothy↗

Current Practices in Distribution Utility Resilience Planning for Winter Storms

This report is part of a series of hazard-focused case studies examining common practices in electric utility resilience planning. We use standard terminology defining resilience as the ability to anticipate, withstand, absorb, and recover from hazards that cause long duration outages. We distinguish between reliability and resilience using Institute of Electrical and Electronics Engineers (IEEE) 1366-2022, which defines major events as an event that exceeds reasonable design and/or operational limits of the electric power system. Resilience planning is focused on major event days and reliability planning is focused on nonmajor event days. Utility resilience plans are assessed according to common resilience components identified in existing resilience frameworks. The focus of this report is on winter storms in which the primary hazards are heavy snowfall, freezing rain, ice, extreme cold, severe wind, and flooding. These hazards can also contribute to generation shortages, resulting in bulk power system impacts that have consequences for the distribution system, such as load shedding. Stand-alone reports focusing on wildfires and nonwinter storms have been published in parallel with this report. This report can be used as a starting point for understanding potential investment prioritization processes and investment options. This report is intended to improve utility resilience planning by supporting constructive dialogue among utilities, regulators, and other stakeholders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

PV Reliability and Resilience in Challenging Climates

Challenging climates for Photovoltaics are usually based on climate classification. However, extreme weather events such as high wind, flooding, large hail, extreme snow etc. have become more ubiquitous globally. To study the impact of extraordinary weather events on PV reliability we used two of the largest databases in the USA. First, the National Oceanic and Atmospheric Administration (NOAA) database on extreme weather and secondly, the PV Fleet Data Initiative where we have collected high-resolution PV performance data of more than 8 gigawatts or about 6-7% of all commercial and utility systems in the USA. We analyzed almost 200 systems between 2008-20022 that were immediately impacted by these weather events. The immediate impact (outages) was determined to be about 1% of or a median of approximately 3 days of annual lost production. However, the risk these events pose is exemplified by a long tail where 0.4 % of all systems lost more than 2 weeks annual production. We also found a threshold for high wind (90 km/hr) and hail (25mm), above which we observed significantly higher degradation implying long-term damage to the systems. In addition, we are using satellite imagery to quantify visible damage to PV plants. Finally, we share module, design and installation lessons from some observed case studies to improve extreme weather resilience for PV power systems.

degradation↗

A building performance-based approach to determining energy resilience for grocery stores in the event of a power outage

Evaluating progress toward a built environment that is best equipped to serve communities during a regional power outage will require metrics that capture the energy resilience of the unique buildings and businesses most crucial to the well-being of those nearby. We focused on grocery stores as key buildings for which access, and thus energy resilience, is critical during a disaster when power is unavailable. We evaluated the energy resilience of these buildings by offering and testing building-scale metrics that assess business continuity potential during a power outage. Metrics proposed in this study are calculated based on the unique power loads characteristic to grocery stores, primarily refrigeration and maintaining safe indoor environmental conditions. Building simulations based on varying levels of backup power were carried out against occupant safety and comfort parameters to apply these metrics, with additional criteria imposed on grocery stores to capture the inventory and sales loss from food spoilage resulting from a lack of refrigeration power. Findings from this study demonstrate the feasibility of our proposed metrics and methodology to serve as a low-data burden means for stakeholders to evaluate the energy resilience of grocery stores, with greater implications in helping to understand the impact on community-scale energy resilience.

Siegel, Lino Sanchez↗