Relaying for Distribution and Microgrids Evolving from Radial to Bidirectional Power Flow
As distributed energy resources (DERs) achieve higher penetration levels in distribution systems, the normal flow of power (and fault current) is no longer unidirectional, from substation source to load (or fault). The increased importance of DERs has also led to revisions in the DER interconnection standards, particularly voltage regulation and ride-through, with publication of a new IEEE Standard 1547 2018. These changes have complicated normal distribution system operation, and they will also complicate distribution system protection. The U.S. Department of Energy undertook a review of the protection state of the art for this new environment in order to identify gaps and propose near-term solutions.
Protective Relaying for Distribution and Microgrids Evolving from Radial to Bi-Directional Power Flow
As distributed energy resources (DER) achieve higher penetration levels in distribution systems, the normal flow of power (and fault current) is no longer unidirectional, from substation source to load (or fault). The increased importance of DER has also led to pending revisions in the DER interconnection standards, particularly voltage regulation and ride-through, with publication of a new IEEE Standard 1547 expected in early 2018. These changes have complicated normal distribution system operation, and they will also complicate distribution system protection. The U. S. Department of Energy undertook a review of protection state-of-the-art for this new environment in order to identify gaps and propose near-term solutions.
Linear Power-Flow Models in Multiphase Distribution Networks: Preprint
This paper considers multiphase unbalanced distribution systems and develops approximate power-flow models where bus-voltages, line-currents, and powers at the point of common coupling are linearly related to the nodal net power injections. The linearization approach is grounded on a fixed-point interpretation of the AC power-flow equations, and it is applicable to distribution systems featuring (i) wye connections; (ii) ungrounded delta connections; (iii) a combination of wye-connected and delta-connected sources/loads; and, (iv) a combination of line-to-line and line-to-grounded-neutral devices at the secondary of distribution transformers. The proposed linear models can facilitate the development of computationally-affordable optimization and control applications -- from advanced distribution management systems settings to online and distributed optimization routines. Performance of the proposed models is evaluated on different test feeders.
Optimal Power Flow in DC Networks with Robust Feasibility and Stability Guarantees
With high penetrations of renewable generation and variable loads, there is significant uncertainty associated with power flows in DC networks such that stability and operational constraint satisfaction are of concern. Most existing DC network optimal power flow (DN-OPF) formulations assume exact knowledge of loading conditions and do not provide stability guarantees. Here, in contrast, this paper studies a DN-OPF formulation which considers both stability and operational constraint satisfaction under uncertainty. The need to account for a range of uncertainty realizations in this paper's robust optimization formulation results in a challenging semi-infinite program (SIP). The proposed solution algorithm reformulates this SIP into a computationally tractable problem by constructing a tight convex inner approximation of the stability set using sufficient conditions for the existence of a feasible and stable power flow solution. Optimal generator set-points are obtained by optimizing over the proposed convex stability set. The validity and effectiveness of the propose algorithm is demonstrated through various DC networks adapted from IEEE test cases.
Advanced Transmission Technologies – GETs and HPCs Session 2: Advanced Power Flow Control and Transmission Topology Optimization
The INL TADA GETs Cohort Session 2, held on November 7, 2025, conducted in collaboration with ScottMadden, focused on two core Advanced Transmission Technologies (ATTs): Advanced Power Flow Control (APFC) and Transmission Topology Optimization (TTO). These technologies are pivotal in enhancing grid flexibility, reliability, and cybersecurity resilience. APFC, particularly through modular FACTS devices like Modular Static Synchronous Series Compensators (M-SSSCs), enables dynamic voltage injection to reroute power flows. The session highlighted the deployment benefits of APFC, such as rapid installation, minimal civil works, and re-deployability. Regulatory drivers like FERC Order 2023 mandate the inclusion of Grid-Enhancing Technologies (GETs) in interconnection studies. Case studies from Central Hudson, CAISO, and National Grid (UK) demonstrated APFC’s effectiveness in congestion relief and cost savings. The session also addressed cybersecurity concerns, including firmware vulnerabilities, SCADA integration risks, and supply chain dependencies. Participants engaged in interactive exercises to rank cybersecurity and supply chain risks, emphasizing the need for robust digital assurance strategies. TTO involves software-based reconfiguration of transmission networks to optimize power flow without new infrastructure. The session showcased its operational value, with examples from SPP, PJM, and MISO showing significant congestion cost reductions. Cybersecurity vulnerabilities were discussed, particularly in API security and software supply chains, referencing incidents like SolarWinds and attacks on Danish utilities. Digital assurance exercises explored worst-case scenarios, attack paths, and mitigation responsibilities between vendors and utilities. Reliability challenges such as algorithm stability, vendor dependency, and operator trust were also examined. Cross-cutting themes emphasized the importance of digital assurance tools, including Software Bills of Materials (SBOMs) and hardware-in-loop testing. Human performance, training, and operational confidence were identified as critical enablers of technology adoption. The session concluded with a preview of Session 3, which will focus on High Performance Conductors (HPCs) and risk-based cybersecurity tools. Session 2 of 3.
Vibration transmission through periodic structures using a mobility power flow approach
The transmission of vibrational power (time averaged) through multiple coupled (periodic) structures is examined. The analysis is performed in the frequency domain and the coupling between the sub-elements of the periodic structure is expressed in terms of structural mobility functions for the junction points and between the junction points of the sub-elements. Equal length spans between stiffeners or supports of the periodic structure are considered. Through the use of the mobility power flow approach, the influence of sub-element and junction parameters, including damping at the joints, can be investigated. The results from the analysis can be in the form of either structural intensity or alternatively structural power content for each of the sub-elements. The examples discussed are for a thin, perfectly periodic beam with a finite number of spans with different types of stiffeners and/or supports between the spans. The excitation of the structure is by a point load located midway along the first span.
Power Flow Models of Grid-Forming Inverters in Unbalanced Distribution Grids
Load unbalance in electric distribution systems is unavoidable. Unbalanced load currents will lead to negative sequence (NS) voltages that may damage electric equipment. Unbalanced power flow analysis is a common tool to detect and mitigate NS voltage issues and requires accurate models of grid components. While traditional source models are available, grid-forming (GFM) inverter models are not well developed. GFM inverters implement various control strategies, which affect their power flow models. Here, in this paper, a novel GFM inverter model considering control effects is proposed. We show that for some control methods, unbalanced system loading will lead to unbalanced terminal voltages of the GFM inverters, which are modeled through an equivalent negative sequence impedance. The proposed models are initially validated using a simple test circuit. Then, they are applied in the power flow analysis on the IEEE 13-bus and 34-bus systems to demonstrate the accuracy improvement over the state-of-the-art. Using time-domain simulations as benchmarks, we show that the proposed models reduce the calculation error of negative sequence voltages by at least 25% in unbalanced distribution systems.
Improved melt model for power flow
Accelerators that drive z-pinch experiments transport current densities in excess of 1 MA/cm 2 in order to melt or ionize the target and implode it on axis. These high current densities stress the transmission lines upstream from the target, where rapid electrode heating causes plasma formation, melt, and possibly vaporization. These plasmas negatively impact accelerator efficiency by diverting some portion of the current away from the target, referred to as “current loss”. Simulations that are able to reproduce this behavior may be applied to improving the efficiency of existing accelerators and to designing systems operating at ever higher current densities. The relativistic particle-in-cell code CHICAGO ® is the primary code for modeling power flow on Sandia National Laboratories’ Z accelerator. We report here on new algorithms that incorporate vaporization and melt into the standard power-flow simulation framework. Taking a hybrid approach, the CHICAGO® kinetic/multi-fluid treatment has been expanded to include vaporization while the quasi-neutral equation-of-motion has been updated for melt at high current-densities. For vaporization, a new one-dimensional substrate model provides a more accurate calculation of electrode thermal, mass, and magnetic field diffusion as well as a means of emitting absorbed contaminants and vaporized metal ions. A quasi-fluid model has been implemented expressly to mimic the motion of imploding liners for accurate inductance histories. For melt, a multi-ion Hall-MHD option has been implemented and benchmarked against Alegra MHD. This new model is described with sufficient detail to reproduce these algorithms in any hybrid kinetic code. Physics results from the new code are also presented. A CHICAGO ® Hall-MHD simulation of a radial transmission line demonstrates that Hall physics, not included in Alegra, has no significant impact on the diffusion of electrode material. When surface contaminant desorption is mocked in as a hydrogen surface plasma, both the surface and bulk-material plasmas largely compress under the influence of the j × B force. Similar results are seen in Alegra, which also shows magnetic and material diffusion scaling with peak current. Test vaporization simulations using MagLIF and a power-flow experimental geometry show Fe + ions diffuse only a few hundred µm from the electrodes, so present models of Z power flow remain valid.
Microgrid Power Flow Control with Integrated Battery Management Functions
This paper presents a microgrid power flow control for islanded microgrids consisting of photovoltaic (PV) system, battery energy storage system (BESS) and diesel generator. The proposed control ensures automatic coordination among the microgrid units. To achieve the coordination, the local control of PV system and BESS are configured to regulate power flow without relying on communications. The generator is controlled as the back-up source and its connection depends on battery state of charge (SOC). A state machine with hysteresis settings is used to trigger smooth transition among operation modes. Not only does the proposed controller consider battery SOC and power limits, but also integrates three-stage charging control as battery charging mechanism, which is not considered in the existing literature. The proposed control is validated for an islanded hybrid microgrid using an OPAL-RT real-time simulator.
Probabilistic Vulnerability Assessment Based on Power Flow and Voltage Distribution
Risk assessment of large scale power systems has been an important problem in power system reliability study. Probabilistic technique provides a powerful tool to solve the task. In this paper, we present the results of a study on probabilistic vulnerability assessment on WECC system. Cumulant based expansion method is applied to obtain the probabilistic distribution function (PDF) and cumulative distribution function (CDF) of power flows on transmission lines and voltage. Overall risk index based on the system vulnerability analysis is calculated using the WECC system. The simulation results based on WECC system is used to demonstrate the effectiveness of the method. The methodology can be applied to the risk analysis on large scale power systems.
Dynamic ADMM for Real-Time Optimal Power Flow
This paper considers distribution networks featuring distributed energy resources (DERs), and develops a dynamic optimization method to maximize given operational objectives in real time while adhering to relevant network constraints. The design of the dynamic algorithm is based on suitable linearization of the AC power flow equations, and it leverages the so-called alternating direction method of multipliers (ADMM). The steps of the ADMM, however, are suitably modified to accommodate appropriate measurements from the distribution network and the DERs. With the aid of these measurements, the resultant algorithm can enforce given operational constraints in spite of inaccuracies in the representation of the AC power flows, and it avoids ubiquitous metering to gather the state of noncontrollable resources. Optimality and convergence of the proposed algorithm are established in terms of tracking of the solution of a convex surrogate of the AC optimal power flow problem.
Application of the mobility power flow approach to structural response from distributed loading
The problem of the vibration power flow through coupled substructures when one of the substructures is subjected to a distributed load is addressed. In all the work performed thus far, point force excitation was considered. However, in the case of the excitation of an aircraft fuselage, distributed loading on the whole surface of a panel can be as important as the excitation from directly applied forces at defined locations on the structures. Thus using a mobility power flow approach, expressions are developed for the transmission of vibrational power between two coupled plate substructures in an L configuration, with one of the surfaces of one of the plate substructures being subjected to a distributed load. The types of distributed loads that are considered are a force load with an arbitrary function in space and a distributed load similar to that from acoustic excitation.
Dynamic ADMM for Real-Time Optimal Power Flow: Preprint
This paper considers distribution networks featuring distributed energy resources (DERs), and develops a dynamic optimization method to maximize given operational objectives in real time while adhering to relevant network constraints. The design of the dynamic algorithm is based on suitable linearizations of the AC power flow equations, and it leverages the so-called alternating direction method of multipliers (ADMM). The steps of the ADMM, however, are suitably modified to accommodate appropriate measurements from the distribution network and the DERs. With the aid of these measurements, the resultant algorithm can enforce given operational constraints in spite of inaccuracies in the representation of the AC power flows, and it avoids ubiquitous metering to gather the state of non-controllable resources. Optimality and convergence of the propose algorithm are established in terms of tracking of the solution of a convex surrogate of the AC optimal power flow problem.
Experimental Validation of an Explicit Power-Flow Primary Control in Microgrids
The existing approaches to control electrical grids combine frequency and voltage controls at different time-scales. When applied in microgrids with stochastic distributed generation, grid quality of service problems may occur, such as under- or overvoltages as well as congestion of lines and transformers. The COMMELEC framework proposes to solve this compelling issue by performing explicit control of power flows with two novel strategies: 1) a common abstract model is used by resources to advertise their state in real time to a grid agent; and 2) subsystems can be aggregated into virtual devices that hide their internal complexity in order to ensure scalability. While the framework has already been published in the literature, in this paper, we present the first experimental validation of a practicable explicit power-flow primary control applied in a real-scale test-bed microgrid. We demonstrate how an explicit power-flow control solves the active and reactive power sharing problem in real time, easily allowing the microgrid to be dispatchable in real time (i.e., it is able to participate in energy markets) and capable of providing frequency support, while always maintaining quality of service.
Optimal Power Flow Pursuit
This paper considers distribution networks featuring inverter-interfaced distributed energy resources, and develops distributed feedback controllers that continuously drive the inverter output powers to solutions of AC optimal power flow (OPF) problems. Particularly, the controllers update the power setpoints based on voltage measurements as well as given (time-varying) OPF targets, and entail elementary operations implementable onto low-cost microcontrollers that accompany power-electronics interfaces of gateways and inverters. The design of the control framework is based on suitable linear approximations of the AC power-flow equations as well as Lagrangian regularization methods. Convergence and OPF-target tracking capabilities of the controllers are analytically established. Overall, the proposed method allows to bypass traditional hierarchical setups where feedback control and optimization operate at distinct time scales, and to enable real-time optimization of distribution systems.
Continuation Power Flow Analysis for PV Integration Studies at Distribution Feeders
This paper presents a method for conducting continuation power flow simulation on high-solar penetration distribution feeders. A load disaggregation method is developed to disaggregate the daily feeder load profiles collected in substations down to each load node, where the electricity consumption of residential houses and commercial buildings are modeled using actual data collected from single family houses and commercial buildings. This allows the modeling of power flow and voltage profile along a distribution feeder on a continuing fashion for a 24- hour period at minute-by-minute resolution. By separating the feeder into load zones based on the distance between the load node and the feeder head, we studied the impact of PV penetration on distribution grid operation in different seasons and under different weather conditions for different PV placements.
Optimal Power Flow in Multiphase Radial Networks with Delta Connections: Preprint
This paper focuses on multiphase radial distribution networks with mixed wye and delta connections, and proposes a semidefinite relaxation of the AC optimal power flow (OPF) problem. Two multiphase power-flow models are developed to facilitate the integration of delta-connected generation units/loads in the OPF problem. The first model extends traditional branch flow models - and it is referred to as extended branch flow model (EBFM). The second model leverages a linear relationship between per-phase power injections and delta connections, which holds under a balanced voltage approximation (BVA). Based on these models, pertinent OPF problems are formulated and relaxed to semidefinite programs (SDPs). Numerical studies on IEEE test feeders show that SDP relaxations can be solved efficiently by a generic optimization solver. Numerical evidences indicate that solving the resultant SDP under BVA is faster than under EBFM. Moreover, both SDP solutions are numerically exact with respect to voltages and branch flows. It is also shown that the SDP solution under BVA has a small optimality gap, while the BVA model is accurate in the sense that it reflects actual system voltages.