Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Holistic Small-Signal Stability Analysis for Large-Scale Inverter-Intensive Power Systems with Coupled and Full-Order Dynamics from Control Systems and Power Networks

The increasing penetration of inverter-based resources (IBRs) into the existing power systems introduces tremendous benefits for enhanced sustainability but also poses inevitable challenges in terms of insufficient inertia, potential instability, and complex network dynamics, among others. However, the additional coupling introduced by the interactions among gridfollowing (GFL) and grid-forming (GFM) IBRs and the other components (i.e., synchronous generators [SGs], loads, and network, etc.) has not been clearly explored. A holistic, scalable, and quantitative stability analysis framework with the control systems and power networks is still missing. Here, in this paper, to fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established. An extended power flow model with operation dynamics from both generator control schemes and power networks is proposed to provide the varying steady-state operating points for small-signal modeling. The proposed method is compared with MATLAB solvers, and the results show that the proposed approach has a minimum calculation time, which can be less than 12 seconds for a large-scale power system with up to 2,000 buses. Furthermore, a quantitative method is developed to identify the impacts of IBRs on system performance with emphases on the potential stability issues with GFL IBRs, additional benefits of employing GFM IBRs, the feasibility of replacing SGs with GFM IBRs, and the impact of penetration level of different kinds of generation units. Finally, a field island power system is used to verify the proposed approach, and hardware-in-the-loop (HIL) tests are provided to further demonstrate the effectiveness of the proposed analysis.

14 SOLAR ENERGY↗

Integrating Transactive Energy into Reliability Evaluation for a Self-healing Distribution System with Microgrid

Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution systems reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. Here, a transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Framework for Analysis and Quantification of Wide-Area Control Resilience for Power Systems

Wide-area control helps damp the inter-area oscillations in modern power systems. However, compared to traditional local control, it is more vulnerable to cyber attacks due to its dependence on remote real-time-communicated measurements. In this paper, a formal mathematical framework for analyzing resilience of various wide-area controllers under adversarial scenarios is proposed. A novel resilience index based on the $\H_2$ norm of the post-attack closed-loop system is defined. Computation of such an index is, in general, challenging due to the combinatorial nature of the attack profiles and the bilinear nature of the problem. To address these difficulties, a gradient-based path-following-like solution is developed in this paper to solve a relaxed version of the original non-convex problem. Case studies on IEEE 39-bus system are performed to demonstrate the usage of the proposed framework.

Marinovici, Laurentiu D.↗

Efficiency and Output Power Sensitivity to Control Parameter Variations in an LCC-Series Wireless Power Transfer System

In wireless power transfer (WPT) systems, output power (Pout) can be controlled through input parameters such as, input voltage (Vin) , duty cycle (d) , and switching frequency (fsw) . The impact of these control parameters on the overall system efficiency has not been explored in previous studies. This paper focuses on the efficiency (η) and Pout sensitivity to these control parameter variations in an LCC-Series tuned WPT system. There are multiple combinations of Vin, d , and fsw that can achieve a specified target Pout . However, it is important to determine the optimal combination of these control variables that will yield the maximum η for a target Pout . A MATLAB/Simulink model is built to calculate and measure η and Pout . In order to achieve this result, several simulations are run where Vin,d , and fsw are swept across a wide range to cover all possible combinations. MATLAB's Sensitivity Analysis toolbox is used to evaluate how the parameters influence the model's output. Finally, an experimental prototype is implemented. The optimal values acquired using the sensitivity analysis is then plugged into the hardware prototype and compared with the simulation. The results obtained confirm the validity of the proposed method.

Harave, Sudarshan↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Application of Controller Area Network for Power Converter Network Monitoring and Control

This presentation explores the adaptation and implementation of CAN bus technology in a network of power converters, emphasizing its potential beyond automotive applications. In this system, multiple power converters can utilize the CAN bus to transmit diverse data types, each assigned specific message and node IDs. A central controller continuously monitors the status of each converter, ensuring efficient management and coordination of power distribution. Additionally, an individual CAN node is

Montoya, Armando Yassir↗

Sequential versus Simultaneous Aging of EPDM Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

Electrical cables are integral to power, control, and instrumentation systems within nuclear power plants (NPPs). Exposure of cable systems within nuclear containment to elevated temperatures and gamma radiation during decades-long operation of NPPs can lead to degradation of cable polymeric insulation. Prediction of nuclear cable insulation degradation is complicated as thermal and radiation stress are not additive. In this work, we explore the relative effects of simultaneous and sequential thermal and gamma irradiation on the aging of ethylene-propylene-diene (EPDM) elastomer insulation to better understand realistic scenarios of cable insulation degradation. Cable insulation samples of EPDM were subjected to up to 320 kGy of gamma radiation at a dose rate of 300 Gy/hr in two heating scenarios: (1) simultaneously aged samples were heated at 150°C during irradiation and (2) sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation at ambient temperature. The mass, tensile elongation at break, and carbonyl index were assessed to quantify aging of the polymers. The simultaneous aging scenario was found to the more severe of the two for EPDM insulation degradation.

ethylene-propylene-diene elastomer, EPDM, nuclear ↗

Dynamic Restoration Strategy for Distribution System Resilience Enhancement

In electric power distribution systems, distributed energy resources (DERs) can act as controllable power sources and support utility operators to minimize power outages after extreme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influences of extreme events and the capabilities of DERs are dynamic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/dis-turbance information and the availability of DERs. In this paper, we propose a new dynamic restoration strategy for distribution systems to enhance system resilience against potential hazards. An efficient reconfiguration algorithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER operation set points based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

distributed energy resources (DERs)↗

Model-Free Dynamic Voltage Control of Distributed Energy Resource (DER)-Based Microgrids

In this paper, we present a new control technique for sustaining dynamic voltage stability by effective reactive power control and coordination of distributed energy resources (DERs) in microgrids. The proposed control technique is based on model-free control (MFC), which has shown successful operation and improved performance in different domains and applications. This paper presents its first use in the voltage stability of a microgrid setting employing multiple synchronous generator (SG)-based and power electronic (PE)-based DERs. MFC is a computationally efficient, data-driven control technique that does not require modelling of the different components and disturbances in the power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by multiple DERs is considered as a case study and the overall dynamic voltage stability is investigated using time-domain dynamic simulations. Numerical results show that the proposed MFC provides improvements on the dynamic load bus voltage profiles and requires less computational time as compared to the traditional enhanced microgrid voltage stabilizer (EMGVS) scheme. Due to its simplicity and low computational requirement, MFC can be easily implemented in resource-constrained computing devices such as smart inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A machine learning-based fast frequency response control for a VSC-HVDC system

An HVDC system can realize a very fast frequency response to the disturbed system under a contingency because its active power control is decoupled from the frequency deviation. However, most of existing HVDC frequency control strategies are coupled with system primary frequency control and secondary frequency control. Since the traditional system frequency control is dominated by the thermal generators, the advantage of the fast response of the HVDC system is not made fully used. The development of a frequency response estimation based on a machine learning algorithm provides another approach to improve the frequency response capability of the HVDC system. Different from other frequency deviation tracking strategies, a machine learning based HVDC frequency response control can directly increase the power flow of a HVDC system by estimation of the system generator or load lost. In this paper, a fast frequency response control using a HVDC system for a large power system disturbance based on the multivariate random forest regression (MRFR) algorithm is proposed. The simulation is carried out with an integrated power system model based on the North American interconnections. The simulation results indicate that the proposed MRFR based frequency response control can significantly improve the frequency low point during an event, while stabilizing the frequency in advance.

42 ENGINEERING↗

Comparative Evaluation of the Single-Phase Shift and Extended-Phase Shift Control for Isolated DC-DC Converter

Abstract: This paper presents a comparative evaluation of the Single-Phase Shift (SPS) and Extended-Phase Shift (EPS) controls for the isolated DC-DC Converter. The analysis is based on the power regulation range, flexibility of operation, current stress on power devices, system efficiency while focusing on the issue of backflow power, control complexity, design and implementation overhead, and stability of the entire system. It is also examined how the backflow influences power circulation and increases current stress. Here, the Dual Active Bridge (DAB) Converter is employed to assess the performance of the control methods. Compared to SPS control, EPS offers a wider power regulation range, greater flexibility, lower current stress, and better system efficiency. However, EPS has increased control complexity, design and implementation overhead, and often requires sophisticated feedback control loops. The comparison is made through mathematical modeling of power transfer, backflow, and current stress. Simulation results validate the comparative analysis presented.

Amir, Aamir [The University of Alabama (UA)]↗

Redesign of the Coils for the 60T Controlled-Waveform Magnet at NHMFL

Driven by the1.4 GW generator, the 60T Controlled Waveform (60 TCW) magnet was the most powerful controlled waveform system in the world and had always been one of most important magnets to the National High Magnetic Field (NHMFL) and high-field research community because of its following unique features: (1) quasi-static field up to 60 T with 100 ms flat-top and total pulse-length of about 2000 ms, (2) variable magnetic field waveforms such as staircase and triangle with flat-top (3) relative large bore (32 mm) and (4) very fast cooling time (20 minutes) between pulses [Boebinger, 2001], [Crooker et al. 2001]. The magnet is composed of nine concentric coils, with each coil consisting of several conductor winding layers reinforced by a high-strength metallic shell. The magnet underwent a catastrophic failure in 2000 and all the coils had to be rebuilt. In late 2014 the second magnet version failed near the mid-plane of coil 7. The simulations afterward that incident indicated that the overall strength of the coil would be increased by replacing a section of the reinforcing shell with Zylon fiber-epoxy composite. This reduces the stress and thus significantly lowers the level of plastic deformation in the windings. The role of the metal and Zylon fiber reinforcing layers in bearing the axial and radial Lorentz forces has been studied to optimize the magnet design. Here, the results of the optimization will be discussed as well as challenges that have been presented in rebuilding the individual coils of the magnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated Dynamic Facade Control with an Agent-based Architecture for Commercial Buildings

Dynamic façades have significant technical potential to minimize heating, cooling, and lighting energy use and peak electric demand in the perimeter zone of commercial buildings, but the performance of these systems is reliant on being able to balance complex trade-offs between solar control, daylight admission, comfort, and view over the life of the installation. As the context for controllable energy-efficiency technologies grows more complex with the increased use of intermittent renewable energy resources on the grid, it has become increasingly important to look ahead towards more advanced approaches to integrated systems control in order to achieve optimum life-cycle performance at a lower cost. This study examines the feasibility of a model predictive control system for low-cost autonomous dynamic façades. A system architecture designed around lightweight, simple agents is proposed. The architecture accommodates whole building and grid level demands through its modular, hierarchical approach. Automatically-generated models for computing window heat gains, daylight illuminance, and discomfort glare are described. The open source Modelica and JModelica software tools were used to determine the optimum state of control given inputs of window heat gains and lighting loads for a 24-hour optimization horizon. Penalty functions for glare and view/ daylight quality were implemented as constraints. The control system was tested on a low-power controller (1.4 GHz single core with 2 GB of RAM) to evaluate feasibility. The target platform is a low-cost ($35/unit) embedded controller with 1.2 GHz dual-core cpu and 1 GB of RAM. Configuration and commissioning of the curtainwall unit was designed to be largely plug and play with minimal inputs required by the manufacturer through a web-based user interface. An example application was used to demonstrate optimal control of a three-zone electrochromic window for a south-facing zone. The overall approach was deemed to be promising. Further engineering is required to enable scalable, turnkey solutions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modular DC circuit breaker with integrated energy storage for future DC networks

A T-breaker is an all-in-one solution for dc microgrid fault protection, power flow control, and power quality improvement. A T-breaker features a modular multilevel “T” structure with integrated energy storage devices. The two horizontal arms of the T-breaker realize fault current breaking, load voltage compensation, and power flow control; and the vertical arm of the T-breaker realizes shunt compensation. The configuration provides excellent voltage scalability and relaxes the requirements on the switching signal synchronization during fault transients. The local energy storage in sub-modules eases the fault energy dissipation requirement placed on the traditionally-adopted surge arrestors. The modular multilevel structure also offers immense control flexibility for all types of targeted functions of the provided T-breaker.

Wang, Jin↗

Efficient learning of power grid voltage control strategies via model-based deep reinforcement learning

Here this article proposes a model-based deep reinforcement learning (DRL) method to design emergency control strategies for short-term voltage stability problems in power systems. Recent advances show promising results for model-free DRL-based methods in power systems control problems. But in power systems applications, these model-free methods have certain issues related to training time (clock time) and sample efficiency; both are critical for making state-of-the-art DRL algorithms practically applicable. DRL-agent learns an optimal policy via a trial-and-error method while interacting with the real-world environment. It is also desirable to minimize the direct interaction of the DRL agent with the real-world power grid due to its safety-critical nature. Additionally, the state-of-the-art DRL-based policies are mostly trained using a physics-based grid simulator where dynamic simulation is computationally intensive, lowering the training efficiency. We propose a novel model-based DRL framework where a deep neural network (DNN)-based dynamic surrogate model (SM), instead of a real-world power grid or physics-based simulation, is utilized within the policy learning framework, making the process faster and more sample efficient. However, having stable training in model-based DRL is challenging because of the complex system dynamics of large-scale power systems. We addressed these issues by incorporating imitation learning to have a warm start in policy learning, reward-shaping, and multi-step loss in surrogate model training. Finally, we achieved 97.5% reduction in samples and 87.7% reduction in training time for an application to the IEEE 300-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Subcritical-voltage magnetron RF power source

A system and method of operating a magnetron power source can achieve a broad range of output power control by operating a magnetron with its cathode voltage lower than that needed for free running oscillations (e.g., below the Kapitsa critical voltage or equivalently below the Hartree voltage) A sufficiently strong injection-locking signal enables the output power to be coherently generated and to be controlled over a broad power range by small changes in the cathode voltage. In one embodiment, the present system and method is used for a practical, single, frequency-locked 2-magnetron system design.

30 DIRECT ENERGY CONVERSION↗