Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “potential energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Direct coherent switching with decay of mixing for intersystem crossing dynamics of thioformaldehyde: The effect of decoherence

We evaluate the effect of electronic decoherence on intersystem crossing in the photodynamics of thioformaldehyde. First, we show that the state-averaged complete-active-space self-consistent field electronic structure calculations with a properly chosen active space of 12 active electrons in 10 active orbitals can predict the potential energy surfaces and the singlet–triplet spin–orbit couplings quite well for CH 2 S, and we use this method for direct dynamics by coherent switching with decay of mixing (CSDM). We obtain similar dynamical results with CSDM or by adding energy-based decoherence to trajectory surface hopping, with the population of triplet states tending to a small steady-state value over 500 fs. Without decoherence, the state populations calculated by the conventional trajectory surface hopping method or the semiclassical Ehrenfest method gradually increase. This difference shows that decoherence changes the nature of the results not just quantitatively but qualitatively.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Overall chilled water system energy consumption modeling and optimization

The emergence of increasingly affordable variable-speed drive technology has changed the approach used to control chilled water systems equipped with these drives. The purpose of this research was to develop an integrated chilled water modeling technique that can determine the optimal system setpoints and estimate the energy saving potential of chiller system. The chiller system equipped with Variable Frequency Drives (VFDs) on cooling tower fans and condenser water pumps. To accomplish the objective, physical component models of the centrifugal chiller, cooling tower and condenser water pump were established with the goal of incorporating the system’s condenser water flow rate and cooling tower fan speeds as optimization variables. Furthermore, a cooling load prediction algorithm was developed using a multiple non-linear regression model to approximate the building’s cooling load subject to a range of environmental conditions. The inputs and outputs of the individual component models were linked to estimate how adjusting the cooling tower fan and condenser water pump speed would influence the system’s comprehensive performance. Here, the overall system model was then optimized using a generalized reduced gradient optimization algorithm to determine the potential energy savings through speed control with VFDs and to ascertain a control logic strategy for the building automation system to operate the heating and cooling system. A case-study was performed on a single chiller system at a museum and the model was calibrated according to logged data collected over four months. Results showed that for the system analyzed, the energy saving of optimizing the cooling tower fan system was found to be 12–15%, while the energy saving potential of optimizing the condenser water pump with the cooling tower fan was negligible. Additionally, comparing different cooling tower fan control strategies showed that a wet-bulb approach-based cooling tower control strategy was shown to have the highest correlation to the optimized fan speed with an R 2 of 0.924.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unmasking Static Correlation Error in Hybrid Kohn–Sham Density Functional Theory

To uncover the way Hartree–Fock exchange brings static correlation error into hybrid Kohn–Sham density functional theory, we compare the potential energy curves of four diatomic molecules, namely, H 2 , F 2 , HF, and NaF, using both restricted and unrestricted Kohn–Sham theory. Here, we find that increasing the percentage of Hartree–Fock exchange significantly increases the static correlation error because Hartree–Fock exchange replaces the ability of local exchange in density functionals to account for the localization effects associated with static correlation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous velocity and density measurements of fully developed Rayleigh-Taylor mixing

Here, the dynamics of molecular mixing and the energy transfer process in the Rayleigh-Taylor instability (RTI) are studied through the collection of simultaneous density-velocity measurements. These experiments provide simultaneous density-velocity field measurements, in contrast to previous point measurements. Statistically stationary experiments are performed in a “convective-type” gas tunnel facility, with density contrast achieved through the injection of helium into the bottom stream. Three experiments at Atwood number ≈ 0.1 are captured at three outer scale Reynolds numbers Re = 520, 2260, and 4050. Particle image velocimetry and laser induced fluorescence are employed simultaneously. Statistics of the density and velocity show self-similar collapse of RTI profiles at large Reynolds number Re >2000. Flat velocity profiles indicate homogeneous turbulence characteristics in the core of the mixing region. Significant anisotropy develops in the flow, with horizontal velocity fluctuations being only 60% of the vertical velocity fluctuations. The turbulent mass flux is found to be asymmetric about the centerline, with increased peak towards the spike. Measurements of the molecular mixing show that mixing is maximized at the core of the flow and increases with increased Reynolds number. The transport equation of density-specific-volume correlation b shows that it is mostly produced in the core of the mixing region, and that the spatial evolution of its profile is the result of transport by bulk motion of the bubble and spike. Energy transfer from gravitational potential energy to turbulent kinetic energy and viscous dissipation is observed to occur in the experiment with a ratio of dissipated energy to potential energy released of 38%. The analysis of the turbulent kinetic energy transport equation budget reveals that production is the primary mechanism towards the growth of turbulent kinetic energy in the core of the flow, and is asymmetrically slightly skewed towards the spike. However, it is through the transport that the strong advection at the edges of the mixing region is maintained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic Energy Accuracy of Neural Network Potentials: Harnessing Pretraining and Transfer Learning

Machine learning-based interatomic potentials (MLIPs) have transformed the prediction of potential energy surfaces (PESs), achieving accuracy comparable to ab initio calculations. However, atomic energy predictions, often assumed to lack physical meaning, remain underexplored. In this study, we demonstrate that inaccuracies in atomic energy predictions reduce the robustness and transferability of Neural Network Potentials (NNPs) and atomic energy error can be masked in total energy predictions due to error cancellation. Here, we validate this finding using challenging configurations involving deformation and failure under tensile loading. By pretraining atomic energy predictions using empirical potentials and applying transfer learning with density functional theory (DFT) data, we achieve notable improvements in the accuracy of total energy, forces, and stress predictions. Furthermore, this approach enhances the robustness and transferability of NNPs, emphasizing the importance of atomic energy predictions in developing high-quality and reliable MLIPs.

Active Learning↗

Energy-saving potential evaluation for primary schools with occupant-centric controls

Recent studies demonstrated that there is significant energy-saving potential for primary schools, which heating, ventilation, and air-conditioning (HVAC) systems with occupant-centric control (OCC) is an excellent candidate to save energy. However, such an energy impact has yet to be evaluated for different climate zones as well as different energy code versions, but is critical for technology transfer and deployment. Therefore, this paper conducts comprehensive evaluation on the energy-saving potentials for the primary schools with two advanced OCC strategies: presence-based and counting-based. In this work, ninety-six building energy models with stochastic behavior of occupants are developed and simulated, which consist of two building energy code versions, 16 climate zones, and baseline case (without OCC) and two advanced cases (with OCC). To evaluate the energy saving potentials for OCC, primary schools in the U.S. are used as an example. The results show that there is significant energy-saving potential for primary schools by considering OCC strategies, especially the counting-based case. The energy-saving potential is up to 10.2% for presence-based OCC and 12.41% for counting-based OCC. Furthermore, both climate and code version have a significant impact on energy savings from OCC strategies. The energy-saving potentials vary from 1.79% to 12.41% for different climates and code versions. This evaluation can also contribute to quantify the nationwide energy saving potential for other countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Proper orthogonal descriptors for efficient and accurate interatomic potentials

Here, we present the proper orthogonal descriptors for efficient and accuracy representation of the potential energy surface. The potential energy surface is represented as a many-body expansion of parametrized potentials in which the potentials are functions of atom positions and parameters. The proper orthogonal decomposition is employed to decompose the parametrized potentials into a set of proper orthogonal descriptors (PODs). Because of the rapid convergence of the proper orthogonal decomposition, relevant snapshots can be sampled exhaustively to represent the atomic neighborhood environment accurately with a small number of descriptors. The proper orthogonal descriptors are used to develop interatomic potentials by using a linear expansion of the descriptors and determining the expansion coefficients from a weighted least-squares regression against a density functional theory (DFT) training set. We present a comprehensive evaluation of the POD potentials on previously published DFT data sets comprising Li, Mo, Cu, Ni, Si, Ge, and Ta elements. The data sets represent a diverse pool of metals, transition metals, and semiconductors. The accuracy of the POD potentials are comparable to that of state-of-the-art machine learning potentials such as the spectral neighbor analysis potential (SNAP) and the atomic cluster expansion (ACE).

97 MATHEMATICS AND COMPUTING↗

Potential Effects of Climate Change and Solar Radiation Modification on Renewable Energy Resources

Solar radiation modification (SRM) is a possible deliberate approach to decrease or reflect incoming solar radiation with the goal of reducing global temperatures, which have increased over the last decades due to high atmospheric greenhouse gas concentrations. Stratospheric aerosol injection, specifically, has shown potential for successfully reducing global temperatures in climate model simulations. Despite the growing literature in the areas of climate change and SRM, their combined effects on renewable energy generation, a climate change mitigation strategy, have not been addressed. In this review paper, we synthesize previous literature on the possible effects of climate change and SRM on renewable energy resources (i.e., wind energy, solar energy, biomass energy, and hydropower), review the status of climate change and SRM research, and explore potential effects of SRM on renewable energy primarily in the Continental United States (CONUS), but with global perspectives as well. We discuss the research challenges and impacts of SRM on renewable energy and conclude by discussing the potential implications of SRM for renewables for SRM governance and policy. This work is not advocating for or against SRM. It is highlighting an important potential impact for future decision makers.

Kumler, Andrew [National Renewable Energy Laborato↗

Corroborative Evaluation of the Real-World Energy Saving Potentials of InfoRich Eco-Autonomous Driving (iREAD) System

There has been an increasing interest in exploring the potential to reduce energy consumption of future connected and automated vehicles. People have extensively studied various eco-driving implementations that leverage preview information provided by on-board sensors and connectivity, as well as the control authority enabled by automation. Quantitative real-world evaluation of eco-driving benefits is a challenging task. The standard regulatory driving cycles used for measuring exhaust emissions and fuel economy are not truly representative of real-world driving, nor for capturing how connectivity and automation might influence driving trajectories. To adequately consider real-world driving behavior and potential “off-cycle” impacts, this paper presents four collaborative evaluation methods: large-scale simulation, in-depth simulation, vehicle-in-the-loop testing, and vehicle road testing. These four approaches, spanning simulation and testing aspects, evaluate real-world fuel economy benefits with different ranges and resolutions. The large-scale simulations leverage an extensive real-world driving database to assess overall eco-driving benefits across a range of road network and driving scenarios. The real-world driving data are further leveraged to generate representative driving routes for deeper evaluation. Based on the representative routes, in-depth simulation relying on high-fidelity models investigates how different traffic scenarios can impact the eco-driving performance. The vehicle-in-the-loop setup reinforces the in-depth simulations by conducting tests with an actual vehicle operated on a chassis dynamometer; the measured energy savings were indeed found to agree with the in-depth simulation savings estimates. Finally, limited but representative road testing with the fully integrated vehicle will be conducted to demonstrate the eco-driving capability and conclude the overall evaluation regimen.

ARPA-E↗

Assessment of Wind Energy Resource Potential for Future Human Missions to Mars

Energy sustainability and redundancy for surface habitats, life support systems and scientific instrumentation represent one of the highest-priority issues for future crewed missions to Mars. However, power sources utilized for the current class of robotic missions to Mars may be potentially dangerous near human surface habitats (for example, nuclear) or lack stability on diurnal or seasonal timescales (for example, solar) that cannot be easily compensated for by power storage. Here, we evaluate the power potential for wind turbines as an alternative energy resource on the Mars surface. Using a state-of-the-art Mars global climate model, we analyse the total planetary Martian wind potential and calculate its spatial and temporal variability. We find that wind speeds at some proposed landing sites are sufficiently fast to provide a stand-alone or complementary energy source to solar or nuclear power. While several regions show promising wind energy resource potential, other regions of scientific interest can be discarded based on the natural solar and wind energy potential alone. We demonstrate that wind energy compensates for diurnal and seasonal reductions in solar power particularly in regions of scientific merit in the midlatitudes and during regional dust storms. Critically, proposed turbines stabilize power production when combined with solar arrays, increasing the percent time that power exceeds estimated mission requirements from ~40% for solar arrays alone to greater than 60-90% across a broad fraction of the Mars surface. We encourage additional study aimed at advancing wind turbine technology to operate efficiently under Mars conditions and to extract more power from Mars winds.

atmospheric dynamics↗

Energy Saving Analysis Using Energy Intensity Usage and Specific Energy Consumption Methods

This study presents the energy saving analysis reached through employing the energy intensity usage and specific energy consumption method. The energy analyses conducted in this study are used for implementing a new technology. However, they are additionally used to evaluate the latest concepts, techniques, processes, and uses for technologies, which are aimed at improvement of energy savings. This study shows the correlation between energy consumption, potential energy savings, and the impact of the energy assessment in different industrial sectors. The correlation is found by using two indicators: (1) the energy intensity usage (EIU) and (2) the specific energy consumption (SEC). The data analysis in this study considers the assessments for 67 industries from 2015 to 2019 and classifies those assessments using the Standard Industrial Classification (SIC) code. The results show that energy savings and energy consumption are linearly related. Also, the energy assessment improves energy performance in a more significant way for smaller companies than for larger industries. Furthermore, these results can be extrapolated by identifying the potential benefits of the energy management system (EMS) implementation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive basis sets for practical quantum computing

Electronic structure calculations on small systems such as H 2 , H 2 O, LiH, and BeH 2 with chemical accuracy are still a challenge for the current generation of noisy intermediate-scale quantum (NISQ) devices. One of the reasons is that due to the device limitations, only minimal basis sets are commonly applied in quantum chemical calculations, which allows one to keep the number of qubits employed in the calculations at a minimum. However, the use of minimal basis sets leads to very large errors in the computed molecular energies as well as potential energy surface shapes. One way to increase the accuracy of electronic structure calculations is through the development of small basis sets better suited for quantum computing. In this work, we show that the use of adaptive basis sets, in which exponents and contraction coefficients depend on molecular structure, provides an easy way to dramatically improve the accuracy of quantum chemical calculations without the need to increase the basis set size and thus the number of qubits utilized in quantum circuits. As a proof of principle, we optimize an adaptive minimal basis set for quantum computing calculations on an H 2 molecule, in which exponents and contraction coefficients depend on the H—H distance, and apply it to the generation of H 2 potential energy surface on IBM-Q quantum devices. The adaptive minimal basis set reaches the accuracy of the double-zeta basis sets, thus allowing one to perform double-zeta quality calculations on quantum devices without the need to utilize twice as many qubits in simulations. This approach can be extended to other molecular systems and larger basis sets in a straightforward manner.

97 MATHEMATICS AND COMPUTING↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Off-Road Vehicle Energy-Saving Potential

The U.S. Department of Energy’s (DOE’s) Vehicle Technology Office (VTO) has played a critical role in enabling electrification and reducing fuel consumption in the automotive sector. However, the off-road vehicle sector accounts for 8% of transportation fuel, and that share is likely to increase over time as onroad vehicles move towards electrification. DOE can again play a key role in the off-road vehicle market by providing tools that can be used by academia and the industry to evaluate the impact of advanced technologies. The need for a pre-competitive simulation tool was also identified during a 2019 DOE-led workshop at Argonne National Laboratory that included OEMs and suppliers to this market. Autonomie, a powerful and robust system simulation tool for vehicle energy consumption and performance analysis, was developed by Argonne National Laboratory in collaboration with General Motors. Its application covers energy consumption and performance analysis throughout the entire vehicle development process by leveraging its plug-and-play powertrain and vehicle model architecture and development environment

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nationwide Energy Saving Potential Evaluation for Office Buildings with Occupant-Based Building Controls

The heating ventilation and air-conditioning (HVAC) system is a major contributor to building energy consumption. This paper aims to quantify the nationwide energy savings potential of implementing the occupancy-based control (OBC) for the HVAC system in typical medium-sized office buildings using a whole building simulation program (i.e., EnergyPlus). First, the medium-sized office from the DOE Commercial Prototype Building Models was modified to have detailed layout and space functions. Then, a statistic-algorithm-based tool was used to generate the dynamic occupancy schedules for various rooms. Next, both a baseline case and two OBC cases were created for the comparison based on the updated ASHRAE Standard 90.1 and ASHRAE Guideline 36. The HVAC operation in the baseline case follows a static occupancy schedule and fixed setpoint schedules for both room air temperatures and minimal system outside air flowrates, while the proposed OBC cases use the room temperature reset, system minimum outdoor airflow reset, and zone minimal supply airflow rate reset. These cases were extended to five climate zones in the United States to further quantify the energy savings potential associated with the OBC on a nationwide scale. The preliminary result of this case study shows that there could be significant energy savings potential from the proposed OBC strategies in medium-sized office buildings in the United States.

Pang, Zhihong↗

Energy Savings Potential of SSL in Agricultural Applications

A report on the energy-savings potential of solid-state lighting in agricultural applications, which updates a prior edition that focused on horticultural lighting only, with an expanded focus that includes animal lighting. The analysis considered three indoor horticultural lighting categories: lighting supplemented greenhouses, high intensity sole-source farms, and sole-source indoor vertical farms typically growing leafy greens. To characterize animal lighting, the analysis investigated the three largest markets of livestock in the U.S. that use lighting – poultry, swine, and dairy farming. To estimate energy consumption of agricultural lighting, the analysis utilized interviews with lighting manufacturers, growers, utility companies, academic professionals, and industry consultants, as well as various data sources. Each of these resources enabled the determination of total market size and illuminated area, typical lighting configuration, lighting power density for LED and incumbent technologies, operating hours, and the installed lighting technology mix. Among the major findings: 1. If all indoor horticultural lighting today was converted to LED technology, annual horticultural lighting consumption would be reduced to 6.3 TWh of site electricity, or 60 tBtu of source energy, which represents lighting energy savings of 34% or $350 million. 2. If all animal lighting today was converted to LED technology, annual lighting energy consumption for animal production would be reduced to 2.8 TWh site electricity, or 26 tBtu of source energy, which represents lighting energy savings of 25% or $96 million.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Heating Energy and Cost Savings of Dual Fuel Heat Pump Controls as a Residential Building Equipment Retrofit in the U.S.

This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e.,53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.

Dual Fuel Heat Pump, Control, Residential Building↗

Hybrid Quantum-Classical Neural Network for Calculating Ground State Energies of Molecules

We present a hybrid quantum-classical neural network that can be trained to perform electronic structure calculation and generate potential energy curves of simple molecules. The method is based on the combination of parameterized quantum circuits and measurements. With unsupervised training, the neural network can generate electronic potential energy curves based on training at certain bond lengths. To demonstrate the power of the proposed new method, we present the results of using the quantum-classical hybrid neural network to calculate ground state potential energy curves of simple molecules such as H 2 , LiH, and BeH 2 . The results are very accurate and the approach could potentially be used to generate complex molecular potential energy surfaces.

74 ATOMIC AND MOLECULAR PHYSICS↗