Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “performance test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Multiphysics Simulation of the NASA SIRIUS-CAL Fuel Experiment in the Transient Test Reactor Using Griffin

After approximately 50 years, NASA is restarting efforts to develop nuclear thermal propulsion (NTP) for interplanetary missions. Building upon nuclear engine tests performed from the late 1950s to the early 1970s, the present research and testing focuses on advanced materials and fabrication methods. A number of transient tests have been performed to evaluate materials performance under high-temperature, high-flux conditions, with several more experiments in the pipeline for future testing. The measured data obtained from those tests are being used to validate the Griffin reactor multiphysics code for this particular type of application. Griffin was developed at Idaho National Laboratory (INL) using the MOOSE framework. This article describes the simulation results of the SIRIUS-CAL calibration experiment in the Transient Reactor Test Facility (TREAT). SIRIUS-CAL was the first transient test conducted on NASA fuels, and although the test was performed with a relatively low core peak power, the test specimen survived a temperature exceeding 900 K. Griffin simulations of the experiment successfully matched the reactor’s power transient after calibrating the initial control rod position to match the initial reactor period. The thermal-hydraulics model largely matches the time-dependent response of a thermocouple located within the experiment specimen to within the uncertainty estimate. However, the uncertainty range is significant and must be reduced in the future.

33 ADVANCED PROPULSION SYSTEMS↗

CalTestBed - OnTo Technology - Characterization of Recycled Cathode and Anode Particles as a Function of Process Step (Final Report)

Onto Technology carries out advanced Li-ion battery recycling for industry and. has the only patented technology to produce manufacturing quality electrode materials from recycled batteries. The technology can resolve ongoing cost problems for the industry in life-cycle and conservation of critical materials. Under the Cal TestBed program, Onto Technology teamed with principal investigators at Lawrence Berkeley National Laboratory, who performed tests to evaluate the electrochemical performance of refurbished electrode materials. Other tests to determine structure and morphology of the refurbished materials carried out at LBNL included X-ray diffraction (XRD) and scanning electron microscopy (SEM).

36 MATERIALS SCIENCE↗

Utah FORGE 2439: Well 16B(78)-32 Field-Test Data from Mini-Frac Tests

This submittal includes the field-test data collected during stress tests conducted in the Utah FORGE 16B(78)-32 wellbore to measure/characterize the stresses in the geothermal reservoir. The type of stress test performed is referred to as a mini-frac test or a micro-frac test. The test is a hydraulic fracture test that involves injecting a small volume of water into a short interval of the reservoir that is isolated by a straddle packer to create a fracture. The test provides information about the minimum and maximum horizontal stress at the test depths. A total of seven mini-frac tests were performed within the upper (vertical or nearly vertical) section of the 9-5/8-inch diameter uncased wellbore, between depths of 5,202 ft MD [5,202 ft TVD] and 5,980 ft MD [5966.18 ft TVD]. Two types of data were generated as part of the mini-frac tests. The first type of data is time-series data for each mini-frac test (e.g., injection-rate, test-interval pressure), and are contained in the "Mini-Frac Test Data.zip" file below. The second type is geophysical log data, attached below in the "Geophysical Logs.zip" file. Here, two types of image logs and acoustic logs were obtained before and after the mini-frac tests to examine each test depth for visual evidence of induced fracture(s) and to measure the azimuth (orientation) of any observed fractures. The attached Readme file includes the test depth information and contents of each data file included here. Analysis of the field-test data was conducted and is documented in the attached report below.

15 GEOTHERMAL ENERGY↗

Biomass Cofiring With Precombustion Carbon Capture Baseline Testing at UND EERC

The project was to perform testing that establishes a baseline of precombustion carbon capture performance when combined with coal- and biomass-derived syngas. Goals of the project were to generate syngas from a matrix of coal types, biomass types, and varied fuel concentrations. Solvent performance and contaminant accumulation within the acid gas separation system (AGSS) were examined.

acid gas separation↗

ORNL Package Testing Program Overview

When transporting radioactive or hazardous materials, safety and security are top priorities. Packaging and transportation regulations require reliable evidence that containers have passed rigorous performance tests to ensure that the public and the environment are protected from the hazardous nature of the cargo. Because of its long history in energy and security research, Oak Ridge National Laboratory (ORNL) has needed to ship hazardous packages for the past 65 years. Since the 1940s, ORNL has made significant contributions to transportation regulations and has been at the forefront of regulatory testing development. Today, ORNL is a leader in standards development and testing of designs of radioactive material packages. ORNL plays a critical role in ensuring the safe transportation of radioactive materials across the United States by executing rigorous testing campaigns of packages that contain radioactive materials. Early testing activities focused on supporting the development of transportation regulations established by both the International Atomic Energy Agency (IAEA) and the United States. Currently, all package testing activities are performed under the Package Testing Program (PTP) at the Package Evaluation Facility (PEF) located at the National Transportation Research Center (NTRC), which is about 10 miles from the main ORNL campus. The PTP develops and evaluates testing solutions, ensuring that they are safe efficient, and in compliance with regulatory requirements. The vision for the PTP is to be a world-class leader in the evaluation and testing of radioactive and hazardous material packages. The key elements necessary to fulfill this mission are an experienced and professional staff; state-of-the-art facilities, equipment, and instrumentation; and completion of challenging programs and projects important to package transportation. Collaborations with other internal and external organizations play a significant role in building stronger teams and achieving this vision. By adhering to and advancing regulatory standards, ORNL’s PTP supports development of safe and compliant packaging, safeguarding the transportation process from potential risks associated with radioactive material logistics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

PIPII cryoplant non thermal cycling updates

The Proton Improvement Plan-II (PIP-II) is a crucial upgrade to the Fermilab accelerator complex, featuring a new 800-MeV Superconducting Radio-Frequency (SRF) linear accelerator (LINAC) with 23 cryomodules operating at 2K. The LINAC thermohydraulic conditions are satisfied by the cryogenic subsystems: Cryogenic Distribution System (CDS), a helium refrigerator cold box (CB), a warm compression station (WCS) and a helium recovery system (RSYS). The accelerator has a strict requirement of non-thermal cycling of the LINAC cryomodules during planned and unplanned subsystem outages. This paper presents an integrated operating modes analysis of the of the LINAC/CDS thermohydraulic loads satisfied by the CB/WCS cooling system supported by the RSYS inventory management system. The study is based on latest cryoplant and CDS engineering deliverables, as well as the recent performance data from single cryomodule qualification tests performed at the Fermilab PIP-II Injector Test test s tand. The study evaluates both normal and abnormal operating modes, with a focus on identifying integrated scenarios that put subsystems components under stress. The conclusions of this study will help build redundancy to reduce the risk of thermal cycles during planned and unplanned subsystem outages.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thermocouple Testing in Support of the AGR-5/6/7 Experiment

This report documents thermocouple testing performed in IRC Lab C-15 over a period of seven years. This testing supported selection and characterization of the thermocouple set used in the AGR-5/6/7 experiment. The following summary was taken directly from the report. Temperature measurement is a challenging aspect of very high temperature irradiation experiments because commonly used high-temperature commercial thermocouples such as platinum-rhodium (Types S, R, and B) and tungsten-rhenium (Type C), suffer dramatic drift because of neutron-induced transmutation. As a result, these types of thermocouples, which are used routinely for industrial temperature measurements outside of reactors, are used only in very special circumstances for reactor experiments. Conversely, because of their low neutron cross-sections, Type N thermocouples are affected to only a limited extent by neutron irradiation. However, the use of these nickel-based thermocouples is limited when the temperature exceeds 1050°C due to drift arising from minor alloying elements migrating from the thermocouple's metal sheath to the thermoelements. This change in the composition of the thermo-elements results in significant decalibration of the signal. The issues described above were recognized during the early planning stages of the final AGR experiment (designated AGR-5/6/7), and a thermocouple furnace testing program was performed over a seven-year period (2014-2019, 2021) to first select and then characterize the best thermocouple set for the high temperature regions of the AGR-5/6/7 irradiation experiment. The calculated temperature range of the AGR-5/6/7 experiment was 600–1500°C. For temperatures below 1000°C standard Type N thermocouples were deemed adequate. The furnace testing campaign identified two thermocouple types suitable for measuring temperatures above 1000°C, a Mo/Nb thermocouple developed at INL called HTIR-TC, and a Type N thermocouple developed by Cambridge University (called herein Cambridge Type N), which featured a custom high nickel alloy sheath. One of the original goals of the furnace testing program was to identify a thermocouple capable of low drift operation near the peak temperature expected in AGR-5/6/7, i.e., about 1400°C. The HTIR-TC design appeared promising in this regard, however a manufacturing difficulty proved to be a barrier and instead the furnace testing focused on drift performance at 1250°C. The manufacturing difficulty was that the Nb sheaths of the HTIR-TCs experienced extreme embrittlement when heat treated at 1600°C or greater. Heat treatment is needed to stabilize the emf output of this TC type, and the higher the heat treatment temperature the higher the peak temperature of stable operation. Because of the sheath embrittlement the heat treatment temperature had to be lowered to 1450°C resulting in a stable operating temperature of about 1250°C. One of the successes of the furnace testing program was identification of a shortcoming in the heat treatment procedure that had been traditionally used in the production of HTIR-TCs. The shortcoming was that the entire heated length of the HTIR-TC sensor was not being heat treated, but rather only the part of the sensor expected to experience temperatures above 1000°C. The problem manifested itself when the thermocouples were removed from the heat treat furnace and placed in another furnace with a different geometry, their indicated temperatures would be widely scattered, but mostly in the negative direction. The solution was to heat treat the entire heated length of the sensor. Since the deepest immersion depth in the AGR-5/6/7 experiment was about 40 inches, a heat treatment length of 48 inches was used. After this change was implemented, thermocouples which were moved into a new environment with a different temperature profile (i.e., a different furnace), produced accurate temperature measurements. Although assembly of the AGR-5/6/7 experiment was completed in September of 2017 (and irradiation begun in 2018), furnace testing of thermocouples continued in 2018 and 2019. The main purpose of this testing was to establish very long-term drift characteristics of the HTIR and Cambridge Type N thermocouples installed in the experiment. Representative thermocouples from the same lots as those installed in the AGR-5/6/7 experiment were used. Additionally, thermocouples of different designs, (particularly variations on the HTIR-TC design) were "piggy-backed" on this testing program to provide insights for instrumenting future very high temperature irradiation experiments. This two-year testing program demonstrated that HTIR-TCs and Cambridge Type N TCs could operate at 1250°C for up to 10,000 hrs (and in some cases longer) while experiencing negative drifts on the order of 2-4°C/1000 hrs. This performance was considered acceptable given the extreme operating environment the sensors faced.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proposed New STELLA-2 Tests

In 2025, KAERI and Argonne initiated a collaboration based on software validation using data from tests performed at KAERI’s STELLA-2 facility. STELLA-2 is a large-scale sodium thermal-hydraulic test facility that was originally developed to support KAERI’s development of the PGSFR design concept. KAERI has performed a large number of tests at STELLA-2, providing valuable data to support sodium fast reactor code validation. KAERI will be conducting new tests in 2026, targeting system conditions that were not achieved during previous test campaigns. KAERI has requested from Argonne proposed tests that could be performed during the upcoming test campaign. This report documents Argonne’s proposed tests in fulfillment of KAERI’s request.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance portable ice-sheet modeling with MALI

High-resolution simulations of polar ice sheets play a crucial role in the ongoing effort to develop more accurate and reliable Earth system models for probabilistic sea-level projections. These simulations often require a massive amount of memory and computation from large supercomputing clusters to provide sufficient accuracy and resolution; therefore, it has become essential to ensure performance on these platforms. Many of today’s supercomputers contain a diverse set of computing architectures and require specific programming interfaces in order to obtain optimal efficiency. In an effort to avoid architecture-specific programming and maintain productivity across platforms, the ice-sheet modeling code known as MPAS-Albany Land Ice (MALI) uses high-level abstractions to integrate Trilinos libraries and the Kokkos programming model for performance portable code across a variety of different architectures. In this article, we analyze the performance portable features of MALI via a performance analysis on current CPU-based and GPU-based supercomputers. The analysis highlights not only the performance portable improvements made in finite element assembly and multigrid preconditioning within MALI with speedups between 1.26 and 1.82x across CPU and GPU architectures but also identifies the need to further improve performance in software coupling and preconditioning on GPUs. We perform a weak scalability study and show that simulations on GPU-based machines perform 1.24–1.92x faster when utilizing the GPUs. The best performance is found in finite element assembly, which achieved a speedup of up to 8.65x and a weak scaling efficiency of 82.6% with GPUs. We additionally describe an automated performance testing framework developed for this code base using a changepoint detection method. The framework is used to make actionable decisions about performance within MALI. We provide several concrete examples of scenarios in which the framework has identified performance regressions, improvements, and algorithm differences over the course of 2 years of development.

54 ENVIRONMENTAL SCIENCES↗

H - Ion Source RF Plasma Testing with 13 MHz and 27 MHz at the Spallation Neutron Source (SNS)

The baseline RF-driven H⁻ ion source configuration at the Spallation Neutron Source (SNS) facility uses a continuous wave (CW) 600 W 13 MHz RF system to ignite and maintain a low-density plasma inside the ion source vacuum chamber. After the continuous low-density 13 MHz plasma has been established, a pulsed (typical 1 ms pulse width and 60 Hz pulse repetition rate) 80 kW 2 MHz RF system is used to increase the plasma density to produce the pulsed H⁻ ion beam. Incremental upgrades and improvements to the SNS ion source systems have resulted in the ability to reliably operate an H⁻ ion source for SNS neutron production run cycles that can last up to four months. Conditions inside the SNS H⁻ ion source evolve throughout a four-month run cycle due to changes in impurity levels, sputtering, and erosion. As the internal ion source conditions change during the run cycle, there can also be changes in plasma stability and the 13 MHz RF power level required to ignite the plasma. This paper presents the preliminary results of testing performed on the SNS Ion Source Test Stand (ISTS) system where we looked at plasma ignition and plasma stability using 27 MHz RF in place of the baseline 13 MHz RF system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FOULING MITIGATION FOR LASER IGNITERS IN NATURAL GAS ENGINES

Due to several recent developments in lasers and optics, laser igniters can now be designed to be (i) compact so as to have the same footprint as a standard spark plug, (ii) have low power draw, usually less than 50 Watts, and (iii) have vibration and temperature resistance at levels typical of reciprocating engines. Primary advantages of these laser igniters remain (i) extension of lean or dilution limits for ignition of combustible mixtures, and (ii) improved ignition at higher pressures. Recently, tests performed in a 350 kW six-cylinder stationary natural gas reciprocating engine retrofitted with these igniters showed an extension of the operational envelope to yield efficiency improvements of the order of 2.6% points while being compliant with the mandated emission regulations. Even though laser igniters offer promise, fouling of the final optical element that introduces the laser into the combustion chamber is of concern. After performing a thorough literature search, a test plan was devised to evaluate various fouling mitigation strategies. The final approach that was used is a combination of three strategies and helped sustain an optical transmissivity exceeding 98% even after 1500 h of continuous engine operation at 2400 rpm. Based on the observed trend in transmissivity, it now appears that laser igniters can last up to 6000 h of continuous engine operation in a stationary engine running at 1800 rpm.

spark ignited engines, laser ignition, natural gas↗

Diagnostic Testing for COVID-19 Bridging Study for CDC EUA assays vs CDC Multiplex N1 FAM, N2 SUN, RNAse P ATTO 647 Assays

This report describes testing performed by LANL’s Biological Agent Testing Laboratory (BATL) to validate modifications to the CDC EUA 2019-Novel Coronavirus (2019-nCoV) Real-Time RT-PCR Diagnostic Panel (EUA-CDC-nCoV-IFU). BATL intends to implement the modification to increase thoughput for daily testing. BATL validated the original component, CDC designed primers and probes purchased from IDT (Cat # 10006770) and the new component, CDC assays designed with new Reporter dyes allowing the assays to be multiplexed, IDT (Cat # 10006830, 10006831, 10006823, 10006833, 10006834, 10007050, 10006836, 10006837, 10007062)

59 BASIC BIOLOGICAL SCIENCES↗

2020 Hyperion Infrasound Sensor Equilibration Evaluation

Sandia National Laboratories has performed testing on several Hyperion 5313A infrasound sensors in order to determine the length of time it takes for the sensors to thermally equilibrate under a variety of environmental conditions. The motivation for performing these tests is to aid in determining suitable procedures for station operators to follow when installing these sensors. The desired outcome is for the station operators to be able to determine more quickly and reliably whether the sensors are performing correctly at the time of installation.

47 OTHER INSTRUMENTATION↗

Evaluation of antifouling surfaces using a method that employs mussel larvae settlement quantified by machine learning

Antifouling coating development requires extensive performance testing. Coatings that prevent aquatic larval settlement are of interest because many forms of macrofouling begin at the larval stage. However, field testing can be time consuming and poorly controlled. Herein is reported a screening tool, Settlement of Larvae Assay using Mussels (SLAM), for down-selecting materials prior to field testing. The method entails using a dense concentration of mussel larvae that are allowed to settle on submerged test surfaces. Settled larvae are then quantified to provide a measure of antifouling performance. The SLAM test differentiated coatings with only slight differences in formulation. To enable efficient quantification of dense larvae settlement, an automated counting method was developed that combines two analyses: a color thresholding identifies larvae clumps, and a machine learning algorithm identifies non-clumped larvae. Finally, this automated ‘hybrid’ approach rapidly quantifies settled larvae as effectively as manual counting but in a fraction of the time.

Mytilus↗

Evaluation of Zero-Net-Rate Pumping Tests

Accurately estimating the distribution of aquifer properties is key to understanding contaminant movement in the subsurface. The distribution of aquifer properties is typically addressed using slug or constant-rate well tests, and the pros and cons of these tests are well known. Slug tests are appealing because they avoid removing contaminated water, but their results are affected by well skin and the small volume of displaced water limits the volume of aquifer that can be evaluated. Constant-rate well tests have the disadvantage of requiring disposal of potentially contaminated water, but they can generate properties that are more representative than slug tests, and they can be used to estimate well efficiency and storativity, which are difficult to characterize using slug tests. Periodic pumping tests are appealing because they have many of the advantages and few of the disadvantages of slug and constant-rate well tests. Periodic pumping tests involve cycling the pumping rate with a regular period and measuring the resulting response in monitoring wells. Some of these tests involve imposing a periodic rate on a constant mean rate. However, other tests involve moving water out and back into the well at rates that are balanced so the net rate after each period is zero. Some zero-net-rate (ZNR) well tests use rates that follow a sinusoidal pattern, whereas others use a square wave pattern that switches between a constant rate of pumping and a constant rate of injection to achieve a zero-net rate. ZNR well tests appear to be a useful compromise between slug and constant rate tests, but methods for conducting and analyzing the results from these tests have received limited evaluation. Periodic pumping tests are typically evaluated through recorded pressure responses to a disturbance source. Recent work has demonstrated that the strain field in the vadose zone shows a response to disturbances in the underlying aquifer. Various instrument designs are available that can record vertical and horizontal strain to very precise resolutions (10-9 ε). Measuring the strain in the vadose zone can present lower costs than measuring pressure in a monitoring well, so using strain could improve the resolution of ZNR tests, as well as make these tests potentially cheaper. A ZNR periodic pumping system was constructed and used to perform tests in the Clemson, South Carolina area. The system was designed to pump and inject with a periodic square-wave, so pumping occurs at a constant rate for half the period and is followed by injection at the same rate for half the period resulting in no net gain or loss of water from the aquifer. The system is designed to generate flow rates from 1 to 3.5 gallons per minute (gpm) with a capacity of 875-gallon per half period. Pressure and strain monitoring points are located in the vicinity of the pumping well. A series of 10 ZNR periodic pumping tests were conducted at the field site, with periods ranging from 2 to 540 minutes. Pressure data were collected and recorded in four monitoring wells in various locations around the pumping well. In addition, vertical and horizontal strain and tilt data were recorded in various locations around the pumping well. Traditional aquifer tests, including slug tests and constant-rate pumping tests were conducted at the field site to provide a baseline of aquifer parameter estimates that are compared the results of ZNR tests. Pressure data measured at monitoring wells during ZNR tests were analyzed utilizing an analytical solution (Streltsova, 1988) that assumes a confined aquifer and estimates hydraulic diffusivity and transmissivity using the time lag and amplitude of the pressure signal. The storativity can be separated out from the hydraulic diffusivity using the transmissivity estimate. The time-lag and amplitude of the pressure signals were estimated using a Fourier transform. The time-lag of the primary period of the pressure increases as a linear function of distance from the pumping well, and it increases as the square root of the period of the ZNR test over a range of periods spanning two orders of magnitudes. The first few harmonics follow similar trends, but the higher frequency harmonics diverge from this trend. Strain and tilt data from various instruments in the vadose and saturated zones are periodic during ZNR tests. The time lags of the strain components increase roughly linearly with distance from the well. Many of the time lags of the strain data from the vadose zone are similar to the time lags observed in the pressure data from a similar distance and pumping period. Theoretical experiments were performed to understand how pressure and strain responds to ZNR periodic pumping. The time-lags of the simulated pressure responses match the field data trends. The results were used to validate the Streltsova (1988) solution for periodic pumping to estimate hydraulic diffusivity. Hydraulic diffusivity was estimated to be 1.8 x 10-2 m2s-1 < Dh < 9.0 x 10-2 m2s-1 using pressure data from all the wells during ZNR tests. Transmissivity was estimated to be 0.8 x 10-4 m2s-1 < T < 4.3 x 10-4 m2s-1. Assuming Storativity = T/Dh gives 1.1 x 10-3 < S < 19 x10-3. Transmissivity is used to estimate the hydraulic conductivity, K, by dividing by the assumed aquifer thickness. Two constant-rate pumping tests were conducted and analyzed using two conceptual models: The Hantush (1961) solution was used to analyze data assuming confined conditions and the Neuman (1974) solution was used to analyze data assuming unconfined conditions. The Hantush (1961) solution estimated transmissivity to be 1.6 x 10-4 m2s-1 < T < 1.8 x 10-4 m2s-1 when using data from all the wells. Storativity was estimated to be 4.4 x 10-3 < S < 8.2 x 10-3. Assuming Dh = T/S gives 0.22 x 10-2 m2s-1 < Dh < 3.6 x 10-2 m2s-1. The Neuman (1974) solution estimated transmissivity to be 0.80 x 10-4 m2s-1 < T < 0.84 x 10-4 m2s-1. Total storativity (S + Sy) was estimated to be 22 x 10-3 < S < 110 x 10-3. Storativity excluding the Sy term was estimated to be 2.2 x 10-3 < S < 2.5 x 10-3. Assuming Dh = T/S gives 0.073 x 10-2 m2s-1 < S < 0.36 x 10-2 m2s-1. Two slug tests were performed on the pumping well, PW-2. The Bouwer and Rice (1976) solution for slug tests was used to analyze the data. This solution works for both confined and unconfined conditions, so both conceptual models were covered through the analysis. Hydraulic conductivity was estimated to be 1.95 x 10-6 ms-1 < K < 2.49 x 10-6 ms-1. Statistical comparison show generally no significant difference in the estimates of Dh, K, or S made using ZNR and conventional pumping tests.. However, the total storage estimated by the Neuman (1974) solution for unconfined settings is larger than that estimate using the Streltsove analysis applied to the ZNR tests. This is likely because the Neuman solution considers delayed yield from storage that the water table, whereas the Streltsova (1988) solution assumes confined conditions. The analysis also indicates that there is a statistically significant difference between parameters estimated with conventional slug tests and those measured with either constant-rate pumping tests or ZNR tests. Hydraulic diffusivity is estimated from the time-lag and the distance from the well. The time-lags of the strain data from the vadose zone are similar to the lags of the pressure data from a similar distance. This indicates that hydraulic diffusivities estimated from the strain data measured in the vadose zone would be similar to the estimates from the pressure data measured in the aquifer. There appear to be sign reversals in some of the strain data that were corrected to estimate the time lag. The dissolved oxygen (CO) concentration was measured during several ZNR tests to evaluate the feasibility of using the procedure to increase contaminant degradation kinetics that are related to DO. The results indicate that DO can be increased during the cycling of ZNR tests in some cases.

Smith-Jones, Austin↗

Gear Test Assembly – Report Experimental Testing and Gear Analysis (FY2021 Midyear Report)

The Gear Test Assembly (GTA) has completed three experimental campaigns at the Mechanisms Engineering Test Loop (METL) facility. The most recent campaign tested Inconel 718 spur gears, tapered roller bearings of 52100 bearing steel with no heat treatment, and a lantern ring shaft seal with spring-loaded fasteners. Testing was performed in Test Vessel 1 (TV1) with 250°C sodium that had an oxide concentration of <10ppm. Testing began in February 2021 and was ended in March 2021 when a thrust bearing assembly failed, requiring shutdown and maintenance. The third experimental campaign completed 1,568 simulated fuel assembly maneuvers before the thrust bearing failure. The GTA was removed from TV1 and cleaned in the Carbonation System. The GTA is currently being prepared for the next experimental campaign. Nondestructive examination methods have been developed at Argonne to monitor the health of the GTA spur gears. Eddy current testing (ECT) and ultrasonic testing (UT) were performed prior to sodium testing and after each experimental campaign. The NDE has shown that the primary damage mechanism is mechanical wear on the gear tooth surface. Several larger nicks are observable on the gear faces, with additional large nicks present on the edges of the gear teeth. While this damage is observable, the overall health of the gears is adequate for more in-sodium testing. A total of 12,752 simulated fuel assembly maneuvers have been completed using this set of gears.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analyses of the Constant Rate Discharge Test for 299-W15-225 (2009) and Ringold Formation Unit A Well Development Tests for 699-43-67B (2012) and 699-45-67B (2013)

This Environmental Calculation File (ECF) documents analyses of hydraulic tests performed in the Ringold Formation member of Wooded Island unit A (Rwia) and Ringold Formation member of Wooded Island unit E (Rwie) in the 200 West Area. Two small-scale tests in the Rwia performed in 2012 and 2013 and one large-scale hydraulic test in the Rwie performed in 2009 were analyzed. Heterogeneity in the Rwie was also examined.

54 ENVIRONMENTAL SCIENCES↗