Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parameter calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Calibration of the ARID robot

The author has formulated a new, general model for specifying the kinematic properties of serial manipulators. The new model kinematic parameters do not suffer discontinuities when nominally parallel adjacent axes deviate from exact parallelism. From this new theory the author develops a first-order, lumped-parameter, calibration-model for the ARID manipulator. Next, the author develops a calibration methodology for the ARID based on visual and acoustic sensing. A sensor platform, consisting of a camera and four sonars attached to the ARID end frame, performs calibration measurements. A calibration measurement consists of processing one visual frame of an accurately placed calibration image and recording four acoustic range measurements. A minimum of two measurement protocols determine the kinematics calibration-model of the ARID for a particular region: assuming the joint displacements are accurately measured, the calibration surface is planar, and the kinematic parameters do not vary rapidly in the region. No theoretical or practical limitations appear to contra-indicate the feasibility of the calibration method developed here.

Doty, Keith L↗

Contrast reduction by the atmosphere and retrieval of nonuniform surface reflectance

A radiative transfer model is developed which gives the upward radiance at nadir for any 1-D Lambertian surface reflectance. This model is used to depict the atmospheric effect on the transmittance of contrast for any 1-D surface reflectance. Here by contrast we mean a general variation of the radiation field across the image. With the aid of this model an inversion algorithm is developed for retrieval of true surface reflectance from high resolution satellite data (e.g., Landsat). This inversion technique can be a useful tool for extraction of surface reflectance from satellite data in the case of a surface reflectance variable in one dimension only (e.g., seashore or near borders of big fields). A sensitivity study of the inversion procedure on the knowledge of atmospheric parameters and sensor calibration was performed. It is shown that this inversion technique is stable even in the presence of errors in the sensor calibration and the atmospheric parameters. The method was applied to Landsat data in two wavelengths. The results show reasonable dependence of the derived surface reflectance on the distance from the seashore.

Mekler, Y.↗

Real-Time Visualization of Spacecraft Telemetry for the GLAST and LRO Missions

GlastCam and LROCam are closely-related tools developed at NASA Goddard Space Flight Center for real-time visualization of spacecraft telemetry, developed for the Gamma-Ray Large Area Space Telescope (GLAST) and Lunar Reconnaissance Orbiter (LRO) missions, respectively. Derived from a common simulation tool, they use related but different architectures to ingest real-time spacecraft telemetry and ground predicted ephemerides, and to compute and display features of special interest to each mission in its operational environment. We describe the architectures of GlastCam and LROCam, the customizations required to fit into the mission operations environment, and the features that were found to be especially useful in early operations for their respective missions. Both tools have a primary window depicting a three-dimensional Cam view of the spacecraft that may be freely manipulated by the user. The scene is augmented with fields of view, pointing constraints, and other features which enhance situational awareness. Each tool also has another "Map" window showing the spacecraft's groundtrack projected onto a map of the Earth or Moon, along with useful features such as the Sun, eclipse regions, and TDRS satellite locations. Additional windows support specialized checkout tasks. One such window shows the star tracker fields of view, with tracking window locations and the mission star catalog. This view was instrumental for GLAST in quickly resolving a star tracker mounting polarity issue; visualization made the 180-deg mismatch immediately obvious. Full access to GlastCam's source code also made possible a rapid coarse star tracker mounting calibration with some on the fly code adjustments; adding a fine grid to measure alignment offsets, and introducing a calibration quaternion which could be adjusted within GlastCam without perturbing the flight parameters. This calibration, from concept to completion, took less than half an hour. Both GlastCam and LROCam were developed in the C language, with non-proprietary support libraries, for ease of customization and portability. This no-blackboxes aspect enables engineers to adapt quickly to unforeseen circumstances in the intense operations environment. GlastCam and LROCam were installed on multiple workstations in the operations support rooms, allowing independent use by multiple subsystems, systems engineers and managers, with negligible draw on telemetry system resources.

Stoneking, Eric T.↗

Understanding the Impacts of Land Surface and PBL Observations on the Terrestrial and Atmospheric Legs of Land-Atmosphere Coupling

Accurately representing land-atmosphere (L-A) interactions and coupling in NWP systems remains a challenge. New observations, incorporated into models via assimilation or calibration, hold the promise of improved forecast skill, but erroneous model coupling can hinder the benefits of such activities. To better understand model representation of coupled interactions and feedbacks, this study demonstrates a novel framework for coupled calibration of the Single Column Model (SCM) capability of the NASA Unified Weather Research and Forecasting (NU-WRF) system coupled to NASA’s Land Information System (LIS). The local land-atmosphere coupling (LoCo) process chain paradigm is used to assess the processes and connections revealed by calibration experiments. Two summer case studies in the U. S. Southern Great Plains are simulated in which LSM parameters are calibrated to diurnal observations of LoCo process chain components including 2-meter temperature, 2-meter humidity, surface fluxes (Bowen ratio), and PBL height. Results show a wide range of soil moisture and hydraulic parameter solutions depending on which L-A variable (i.e. observation) is used for calibration, highlighting that improvement in either SHP or ISM when not in tandem with the other can provide undesirable results. Overall, this work demonstrates that a process chain calibration approach can be used to assess L-A connections, feedbacks, strengths, and deficiencies in coupled models, as well as quantify the potential impact of new sources of observations of land-PBL variables on coupled prediction.

Patricia Lawston-Parker↗

Determination of Ballistic Limit for IM7/8552 Using LS-DYNA MAT 261

The goal of the NASA ACC High Energy Dynamic Impact Project is to determine the state of the art of dynamic fracture simulations for high velocity impact for composite fuselage shielding applications. Using a building block approach, several computational models considered under NASA ACC are being validated against test data, starting at unconfigured panels and progressing to configured panels under combined out-of-plane and in-plane loading due to ballistic impact. The computational models being evaluated in this project include MAT 162, MAT 213, MAT 261, SPG, and Peridynamics. In this paper, the simulation results using LS-Dyna Material MAT 261 are presented. In particular, a series of blind predictions for unconfigured panels were performed to determine the ballistic limit or V50 velocity. MAT 261 employs failure approach that is generally physically-based using fracture toughness criteria. The overall material model relies on typical ply-level stiffness properties, similar to MAT 162 and other composite continuum damage material models. The fracture toughness values are based on standard tests, and thus are not subject to extensive calibration. This approach is more efficient than performing extensive optimization studies for calibration of parameters. Also, this approach of relying on physical properties reduces the uncertainty of results, as questions concerning the quality and extent of the calibration studies is no longer relevant. However, it was found that carefully controlled coupon-level tests are needed to accurately obtain the required fracture toughness values. Additionally, it should be noted that there is one significant parameter in MAT 261 that does appear to require calibration, and that is the overall failure strain. This is the strain at which the element is deleted, and is not the same as the strain at which damage begins to accumulate. This failure strain is termed EFS (Effective Failure Strain), and is the maximum effective stain for element failure. Simulations have shown that this value will significantly affect impact response and failure. The paper presents the effect of this element failure strain parameter, along with possible uncertainties in fracture toughness values. With an adjusted appropriate value for EFS, it is seen that simulation results compare well with impact test data for predicted penetration velocity.

Byar, Alan↗

An Observation‐Driven Approach to Improve Vegetation Phenology in a Global Land Surface Model

An empirical model calibration approach is presented that aims to approximate missing biosphere processes in a global land surface model without the need for substantial model structural changes. The strategy is implemented here using the NASA Catchment‐CN land surface model and Moderate Resolution Imaging Spectroradiometer (MODIS) observations of the fraction of absorbed photosynthetically active radiation (FPAR). Existing plant functional types (PFTs) of the Catchment‐CN model are divided into three subtypes, based on the bias between the model‐simulated and MODIS‐observed FPAR. Separate sets of vegetation parameters for each subtype are then calibrated at a small number of grid cells with homogeneous, single‐PFT land cover, using MODIS FPAR reference observations from 2003 to 2009. The effectiveness of the empirical approach at improving the realism of modeled vegetation dynamics is investigated with two global model simulations for the period 2010–2016, one using the newly calibrated parameter values and the other using the original values. Globally, the calibrated parameters reduce the root mean square error (RMSE) of the modeled FPAR with respect to MODIS by 0.029 (∼10%) on average. In some regions, substantially larger RMSE reductions are achieved. RMSE reductions are primarily driven by model bias reductions, with neutral effects on the temporal correlation skill. While the empirical approach is suitable for achieving consistent model improvements, it is shown to be sensitive to the characteristics of the model error, specifically a dominance of the bias component in the case of Catchment‐CN. Ultimately, more fundamental model structural changes may be required to achieve better improvements.

J. Kolassa↗

Bayesian Vision for Shape Recovery

We present a new Bayesian vision technique that aims at recovering a shape from two or more noisy observations taken under similar lighting conditions. The shape is parametrized by a piecewise linear height field, textured by a piecewise linear irradiance field, and we assume Gaussian Markovian priors for both shape vertices and irradiance variables. The observation process. also known as rendering, is modeled by a non-affine projection (e.g. perspective projection) followed by a convolution with a piecewise linear point spread function. and contamination by additive Gaussian noise. We assume that the observation parameters are calibrated beforehand. The major novelty of the proposed method consists of marginalizing out the irradiances considered as nuisance parameters, which is achieved by Laplace approximations. This reduces the inference to minimizing an energy that only depends on the shape vertices, and therefore allows an efficient Iterated Conditional Mode (ICM) optimization scheme to be implemented. A Gaussian approximation of the posterior shape density is computed, thus providing estimates both the geometry and its uncertainty. We illustrate the effectiveness of the new method by shape reconstruction results in a 2D case. A 3D version is currently under development and aims at recovering a surface from multiple images, reconstructing the topography by marginalizing out both albedo and shading.

Jalobeanu, Andre↗

Calibration of a helium-cooled infrared spatial radiometer and grating spectrometer

Methods used by the Space Dynamics Laboratory of Utah State University (SDL/USU) to calibrate infrared sensors are described, using the Infrared Background Signature Survey (IBSS) spatial radiometer and grating spectrometer as examples. A calibration equation and a radiometric model are given for each sensor to describe their responsivity in terms of individual radiometric parameters. The calibration equation terms include dark offset, linearity, absolute responsivity, and measurement uncertainty, and the radiometric model domains include spatial, spectral, and temporal domains. A portable calibration facility, designed and fabricated by SDL/USU, provided collimated, extended, diffuse scatter, and Jones sources in a single cryogenic dewar. This multi-function calibrator allowed calibration personnel to complete a full calibration of the IBSS infrared radiometer and spectrometer in two 15-day periods. A calibration data system was developed to control and monitor the calibration facility, and to record and analyze sensor data.

Jacobsen, Larry↗

Ground-Support Algorithms for Simulation, Processing, and Calibration of Barnes Static Earth Sensor Measurements: Applications to Tropical Rainfall Measuring Mission Observatory

New algorithms are described covering the simulation, processing, and calibration of penetration angles of the Barnes static Earth sensor assembly (SESA) as implemented in the Goddard Space Flight Center Flight Dynamics Division ground support system for the Tropical Rainfall Measuring Mission (TRMM) Observatory. The new treatment involves a detailed analysis of the measurements by individual quadrants. It is shown that, to a good approximation, individual quadrant misalignments can be treated simply as penetration angle biases. Simple formulas suitable for real-time applications are introduced for computing quadrant-dependent effects. The simulator generates penetration angles by solving a quadratic equation with coefficients uniquely determined by the spacecraft's position and the quadrant's orientation in GeoCentric Inertial (GCI) coordinates. Measurement processing for attitude determination is based on linearized equations obtained by expanding the coefficients of the aforementioned quadratic equation as a Taylor series in both the Earth oblateness coefficient (alpha approx. 1/150) and the angle between the pointing axis and the geodetic nadir vector. A simple formula relating a measured value of the penetration angle to the deviation of the Earth-pointed axis from the geodetic nadir vector is derived. It is shown that even near the very edge of the quadrant's Field Of View (FOV), attitude errors resulting from quadratic effects are a few hundredths of a degree, which is small compared to the attitude determination accuracy requirement (0.18 degree, 3 sigma) of TRMM. Calibration of SESA measurements is complicated by a first-order filtering used in the TRMM onboard algorithm to compute penetration angles from raw voltages. A simple calibration scheme is introduced where these complications are avoided by treating penetration angles as the primary raw measurements, which are adjusted using biases and scale factors. In addition to three misalignment parameters, the calibration state vector contains only two average penetration angle biases (one per each pair of opposite quadrants) since, because of the very narrow sensor FOV (+/- 2.6 degrees), differences between biases of the penetration angles measured by opposite quadrants cannot be distinguished from roll and pitch sensor misalignments. After calibration, the estimated misalignments and average penetration angle biases are converted to the four penetration angle biases and to the yaw misalignment angle. The resultant biases and the estimated scale factors are finally used to update the coefficients necessary for onboard computations of penetration angles from measured voltages.

Natanson, G. A.↗

TOPEX microwave radiometer system calibration - Refining the SMMR heritage

A modified version of the Scanning multichannel Microwave Radiometer (SMMR) will be used for wet tropospheric path-delay corrections to the TOPEX/POSEIDON radar altimeter measurements. A number of the sources of calibration problems encountered by SMMR onboard the Seasat and Nimbus-7 platforms have been identified, and appropriate corrections have been attempted. Calibration hardware corrections include a more representative modeling of the microwave losses and reflections, and a reduction in the thermal gradients expected across this hardware through the use of radomes and sun shades and the choice of pertinent orbit parameters. Antenna calibration corrections include a postlaunch fine tuning of the antenna pattern correction algorithm to accommodate small errors in the prelaunch antenna pattern measurements. This is accomplished by overpasses of ground-based, upward-looking water vapor radiometers. An absolute calibration accuracy of 1.0 K or less is anticipated.

Ruf, Christopher S.↗

A calibration adjustment technique combining ERB parameters from different remote sensing platforms into a long-term data set

Earth-radiation-budget (ERB) experiments on board the Nimbus-6 (ERB 6) and Nimbus-7 (ERB 7) spacecraft have measured wide-field-of-view total (0.2 to 50 micron), shortwave (0.2 to 3.8 micron), and near-infrared (0.7 to 2.8 micron) terrestrial irradiances for a joint lifetime of over 8 years. Though the spectral characteristics of both experiments are nearly identical, instrument degradation and altitude differences introduce discrepancies between the two data sets. ERB parameters from these two observing platforms may be combined into a scientifically meaningful data set only after these discrepancies are eliminated. To facilitate the creation of a long-term ERB data set, comparisons of the ERB 6 experiment irradiances with, and calibration adjustments with respect to, the corresponding ERB 7 irradiances have been performed. Two calibration methods were developed and applied to the irradiance data from 28 pairs of collocated orbits. The differential effects of altitude, illumination, albedo, and scene inhomogeneities were applied. The result is a set of calibration adjustments that adjust the ERB 6 data to match the ERB 7 data.

Ardanuy, P. E.↗

Considering Combined or Separated Roughness and Vegetation Effects in Soil Moisture Retrievals

For more than six years, the Soil Moisture and Ocean Salinity (SMOS) mission has provided multi angular and full-polarization brightness temperature (TB) measurements at L-band. Geophysical products such as soil moisture (SM) and vegetation optical depth at nadir (tau(sub nad)) are retrieved by an operational algorithm using TB observations at different angles of incidence and polarizations. However, the quality of the retrievals depends on several surface effects, such as vegetation, soil roughness and texture, etc. In the microwave forward emission model used in the retrievals (L-band Microwave Emission Model, L-MEB),soil roughness is modeled with a semi-empirical equation using four main parameters (Q(sub r), H(sub r), N(sub rp), with p = H or V polarizations). At present, these parameters are calibrated with data provided by airborne studies and in situ measurements made at a local scale that is not necessarily representative of the large SMOS footprints (43 km on average) at global scale. In this study, we evaluate the impact of the calibrated values of N(sub rp) and H(sub r) on the SM and tau(sub nad) retrievals based on SMOS TB measurements (SMOS Level 3 product) over the Soil Climate Analysis Network (SCAN) network located in North America over five years (2011-2015). In this study, Qr was set equal to zero and we assumed that N(sub rH)= N(sub rV). The retrievals were performed by varying N(sub rp) from −1 to 2 by steps of 1 and H(sub r) from 0 to 0.6 by steps of 0.1. At satellite scale, the results show that combining vegetation and roughness effects in a single parameter provides the best results in terms of soil moisture retrievals, as evaluated against the in situ SM data. Even though our retrieval approach was very simplified, as we did not account for pixel heterogeneity, the accuracy we obtained in the SM retrievals was almost systematically better than those of the Level 3 product. Improved results were also obtained in terms of optical depth retrievals. These new results may have key consequences in terms of calibration of roughness effects within the algorithms of the SMOS (ESA) and the SMAP (NASA) space missions.

full-polarization↗

Real-time atmospheric absorption spectra for in-flight tuning of an airborne dial system

Real-time measurements of atmospheric absorption spectra are displayed and used to precisely calibrate and fix the frequency of an Alexandrite laser to specific oxygen absorption features for airborne Differential Absorption Lidar (DIAL) measurements of atmospheric pressure and temperature. The DIAL system used contains two narrowband tunable Alexandrite lasers: one is electronically scanned to tune to oxygen absorption features for on-line signals while the second is used to obtain off-line (nonabsorbed) atmospheric return signals. The lidar operator may select the number of shots to be averaged, the altitude, and altitude interval over which the signals are averaged using single key stroke commands. The operator also determines exactly which oxygen absorption lines are scanned by comparing the line spacings and relative strengths with known line parameters, thus calibrating the laser wavelength readout. The system was used successfully to measure the atmospheric pressure profile on the first flights of this lidar, November 20, and December 9, 1985, aboard the NASA Wallops Electra aircraft.

Dombrowski, M.↗

Streak camera based SLR receiver for two color atmospheric measurements

To realize accurate two-color differential measurements, an image digitizing system with variable spatial resolution was designed, built, and integrated to a photon-counting picosecond streak camera, yielding a temporal scan resolution better than 300 femtosecond/pixel. The streak camera is configured to operate with 3 spatial channels; two of these support green (532 nm) and uv (355 nm) while the third accommodates reference pulses (764 nm) for real-time calibration. Critical parameters affecting differential timing accuracy such as pulse width and shape, number of received photons, streak camera/imaging system nonlinearities, dynamic range, and noise characteristics were investigated to optimize the system for accurate differential delay measurements. The streak camera output image consists of three image fields, each field is 1024 pixels along the time axis and 16 pixels across the spatial axis. Each of the image fields may be independently positioned across the spatial axis. Two of the image fields are used for the two wavelengths used in the experiment; the third window measures the temporal separation of a pair of diode laser pulses which verify the streak camera sweep speed for each data frame. The sum of the 16 pixel intensities across each of the 1024 temporal positions for the three data windows is used to extract the three waveforms. The waveform data is processed using an iterative three-point running average filter (10 to 30 iterations are used) to remove high-frequency structure. The pulse pair separations are determined using the half-max and centroid type analysis. Rigorous experimental verification has demonstrated that this simplified process provides the best measurement accuracy. To calibrate the receiver system sweep, two laser pulses with precisely known temporal separation are scanned along the full length of the sweep axis. The experimental measurements are then modeled using polynomial regression to obtain a best fit to the data. Data aggregation using normal point approach has provided accurate data fitting techniques and is found to be much more convenient than using the full rate single shot data. The systematic errors from this model have been found to be less than 3 ps for normal points.

Varghese, Thomas K.↗

The effect of mismatched components on microwave noise-temperature calibrations

Analysis of errors on microwave noise-temperature measurements is important due to development of very low-noise antenna receiving systems and in the absolute accuracies to which the noise temperatures of these systems can be calibrated. Scattering parameters describe properties of the microwave network connected between noise source and receiver.

Otoshi, T. Y.↗