Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “oscillators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Injection Locking of Gigahertz‐Frequency Surface Acoustic Wave Phononic Crystal Oscillator

Low-noise gigahertz (GHz) frequency sources are essential for applications in signal processing, sensing, and telecommunications. Surface acoustic wave (SAW) resonator-based oscillators offer compact form factors and low-phase noise due to their short mechanical wavelengths and high-quality (Q) factors. However, their small footprint makes them vulnerable to environmental variation, resulting in their poor long-term frequency stability. Injection locking is widely used to suppress frequency drift of lasers and oscillators by synchronizing to an ultra-stable reference. Here, injection locking of a 1-GHz SAW phononic-crystal oscillator is demonstrated, achieving 40-dB phase noise reduction at low offset frequencies and unperturbed low noise at large offset frequencies. Compared to a free-running SAW oscillator, which typically exhibits frequency drifts of several hundred hertz over minutes, the injection-locked oscillator reduces the frequency deviation to below 0.35 Hz. The locking range and oscillator dynamics is also investigated in the injection pulling region. The demonstrated injection-locked SAW oscillator could find applications in high-performance portable telecommunications and sensing systems.

injection locking↗

Synergistic data analytics for electromechanical oscillation in electric power systems

Accurate real-time estimation of the four electromechanical oscillation properties, i.e., dominant oscillation modes, mode shapes, participation factors, and coherent groups, is of great importance to assess and mitigate potential electromechanical oscillations in interconnected power systems. While eigenvalue analysis can realize such estimation, it requires precise linearized dynamic models and accurate parameters, which are highly difficult to obtain in practice. Data fusion-based modal estimation methods can extract the properties of electromechanical oscillations from measurement data without the power system model and parameters, but most of the time only one or two property assessments can be accomplished each time. To overcome this challenge, this paper presents a synergistic data analytics solution to characterize the dynamic behaviors of electromechanical oscillations from real-time measurement data. Here, the proposed method uses optimized variable projection, and it is capable of estimating all four electromechanical oscillation behavior properties from measured responses. Case studies are performed using the simulated measurement data of a 16-generator 68-bus test system and the field measurements collected by the PMUs deployed in the Yunnan Power Grid. The results demonstrate that the proposed synergistic data analytics solution can achieve satisfactory performance in capturing the properties of electromechanical oscillations from measurement data and exhibit strong robustness against measurement noise when compared with existing measurement-based methods.

42 ENGINEERING↗

Eastern Interconnection Wide-Area Oscillation Assessment and Study Report

To meet the government mandates such as Renewable Portfolio Standards (RPS), conventional synchronous generators with rotating mass are being displaced by inverter-based resources (IBRs), leading to high penetration of renewable energy sources (RES). As a result, the inherent properties and characteristics of the transformed generation mix may significantly impact the grid behaviour, and it is of paramount significance that the impact and the consequences of the resource mix change is thoroughly understood to adopt measures to maintain reliable grid operations. Of great concern is the inter-area low-frequency oscillation, which usually propagates through a large region and has a system-wide impact. Such oscillations may lead to unnecessary or inadvertent tripping of generators, that may be simply reacting to the oscillation originating from geographically remote sites. Such tripping of generators can lead to cascading outages, system split and load loss events. Over the years, several system-wide oscillation events have been observed across all three North American interconnections. This project titled Wide-area Oscillation Assessment and Trending Study, sponsored by the Office of Electricity (OE) of the Department of Energy (DOE), aims to conduct the required research to capture and investigate the potential changes in wide-area oscillatory performance of the system as a result of resource mix transition. The Pacific Northwest National Laboratory (PNNL) conducted this research and technical staff of Federal Energy Regulatory Commission (FERC) served as advisors to the project. The primary objective of this study is to assess whether there are significant trends in the power system wide-area oscillatory behaviours, as a result of the generation-mix changes due to the increased penetration of RES in the U.S. Eastern Interconnection (EI). The analysis presented in this report can serve as reference for future grid planning and operation of the EI system. This research conducted in this project evaluates the wide-area oscillatory behaviour of the EI, using a model-based approach for potential future resource mixes, and the measurement-based analysis with 21-month phasor measurement unit (PMU) time series. The oscillation modes in EI system along with the impact of the changes of the generation mix on the frequency and damping ratio (DR) of the oscillations have been studied.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impedance Analysis and PHIL Demonstration of Reactive Power Oscillations in a Wind Power Plant Using a 4-MW Wind Turbine

This paper presents impedance-based analysis, mitigation, and power-hardware-in-the-loop (PHIL) demonstration of reactive power oscillations in a wind power plant using a 4-MW Type III wind turbine drivetrain. Because such low-frequency oscillations result from interactions among slower control loops of wind turbines regulating phasor quantities—active and reactive power output of the wind turbine and the magnitude of voltages at the point of interconnection (POI)—a new type of admittance is defined in terms of phasor quantities for their analysis. The so-called power-domain admittance of a wind turbine is defined as the transfer function from the frequency and magnitude of voltages at the POI to the active and reactive power output of the turbine. The power-domain admittance responses of the 4-MW wind turbine are measured using a 7-MVA grid simulator to identify the source of the reactive power oscillations. Power-domain impedance analysis and PHIL experiments are performed to explain how a resonant mode manifests as turbine-to-turbine and plant-to-grid reactive power oscillations. It is discovered that weaker grids exhibiting high inductive impedance mitigate oscillations in the reactive power output of wind power plants; however, a higher grid impedance does not help in damping turbine-to-turbine reactive power oscillations. This paper presents a simple droop-based solution to eliminate both turbine-to-turbine and plant-to-grid reactive power oscillations.

17 WIND ENERGY↗

Performance Assessment of Fluidic Oscillators Tested on the NASA Hump Model

Flow separation control over a wall-mounted hump model was studied experimentally to assess the performance of fluidic oscillators (sweeping jet actuators). An array of fluidic oscillators was used to control flow separation. The results showed that the fluidic oscillators were able to achieve substantial control over the separated flow by increasing the upstream suction pressure and downstream pressure recovery. Using the data available in the literature, the performance of the fluidic oscillators was compared to other active flow control (AFC) methods such as steady blowing, steady suction, and zero-net-mass-flux (ZNMF) actuators. Several integral parameters, such as the inviscid flow comparison coefficient, pressure drag coefficient, and modified normal force coefficient, were used as quality metrics in the performance comparison of the AFC methods. These quality metrics indicated the superiority of the steady suction method, especially at lower excitation amplitudes that is followed by the fluidic oscillators, steady blowing, and the ZNMF actuators, respectively. An aerodynamic figure of merit (AFM) was also constructed using the integral parameters and AFC power usage. The AFM results revealed that, for this study, steady suction was the most efficient AFC method at lower excitation amplitudes. The steady suction loses its efficiency as the excitation amplitude increases, and the fluidic oscillators become the most efficient AFC method. Both the steady suction and the fluidic oscillators have an AFM > 1 for the range tested in this study, indicating that they provide a net benefit when the AFC power consumption is also considered. On the other hand, both the steady blowing and ZNMF actuators were found to be inefficient AFC methods (AFM < 1) for the current configuration. Although they improved the flow field by controlling flow separation, the power requirement was more than their benefit.

Fluidic oscillators↗

Chemical pumps and flexible sheets spontaneously form self-regulating oscillators in solution

The synchronization of self-oscillating systems is vital to various biological functions, from the coordinated contraction of heart muscle to the self-organization of slime molds. Through modeling, we design bioinspired materials systems that spontaneously form shape-changing self-oscillators, which communicate to synchronize both their temporal and spatial behavior. Here, catalytic reactions at the bottom of a fluid-filled chamber and on mobile, flexible sheets generate the energy to “pump” the surrounding fluid, which also transports the immersed sheets. The sheets exert a force on the fluid that modifies the flow, which in turn affects the shape and movement of the flexible sheets. This feedback enables a single coated (active) and even an uncoated (passive) sheet to undergo self-oscillation, displaying different oscillatory modes with increases in the catalytic reaction rate. Two sheets (active or passive) introduce excluded volume, steric interactions. This distinctive combination of the hydrodynamic, fluid–structure, and steric interactions causes the sheets to form coupled oscillators, whose motion is synchronized in time and space. We develop a heuristic model that rationalizes this behavior. These coupled self-oscillators exhibit rich and tunable phase dynamics, which depends on the sheets’ initial placement, coverage by catalyst and relative size. Moreover, through variations in the reactant concentration, the system can switch between the different oscillatory modes. This breadth of dynamic behavior expands the functionality of the coupled oscillators, enabling soft robots to display a variety of self-sustained, self-regulating moves.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Intrinsic Bulk Quantum Oscillations in a Bulk Unconventional Insulator SmB 6

The finding of bulk quantum oscillations in the Kondo insulator SmB 6 proved a considerable surprise. Subsequent measurements of bulk quantum oscillations in other correlated insulators including YbB 12 lent support to our discovery of a class of bulk unconventional insulators that host bulk quantum oscillations. Here we perform a series of experiments to examine evidence for the intrinsic character of bulk quantum oscillations in floating zone-grown single crystals of SmB 6 that have been the subject of our quantum oscillation studies. We present results of thermodynamic, transport, and composition analysis experiments on pristine floating zone-grown single crystals of SmB 6 and compare quantum oscillations with metallic LaB 6 and elemental aluminum. These results establish the intrinsic origin of quantum oscillations from the insulating bulk of floating zone-grown SmB 6 . The similarity of the Fermi surface in insulating SmB 6 with the conduction-electron Fermi surface in metallic hexaborides is at the heart of a theoretical mystery.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Emergent microrobotic oscillators via asymmetry-induced order

Abstract Spontaneous oscillations on the order of several hertz are the drivers of many crucial processes in nature. From bacterial swimming to mammal gaits, converting static energy inputs into slowly oscillating power is key to the autonomy of organisms across scales. However, the fabrication of slow micrometre-scale oscillators remains a major roadblock towards fully-autonomous microrobots. Here, we study a low-frequency oscillator that emerges from a collective of active microparticles at the air-liquid interface of a hydrogen peroxide drop. Their interactions transduce ambient chemical energy into periodic mechanical motion and on-board electrical currents. Surprisingly, these oscillations persist at larger ensemble sizes only when a particle with modified reactivity is added to intentionally break permutation symmetry. We explain such emergent order through the discovery of a thermodynamic mechanism for asymmetry-induced order. The on-board power harvested from the stabilised oscillations enables the use of electronic components, which we demonstrate by cyclically and synchronously driving a microrobotic arm. This work highlights a new strategy for achieving low-frequency oscillations at the microscale, paving the way for future microrobotic autonomy.

42 ENGINEERING↗

Dimensional crossover in spin Hall oscillators

Auto-oscillations of magnetization driven by direct spin current have been previously observed in multiple quasi-zero-dimensional (0D) ferromagnetic systems such as nanomagnets and nanocontacts. Recently, it was shown that pure spin Hall current can excite coherent auto-oscillatory dynamics in quasi-one-dimensional (1D) ferromagnetic nanowires but not in quasi-two-dimensional (2D) ferromagnetic films. Here we study the 1D to 2D dimensional crossover of current-driven magnetization dynamics in wire-based Pt/Ni 80 Fe 20 bilayer spin Hall oscillators via varying the wire width. We find that increasing the wire width results in an increase of the number of excited auto-oscillatory modes accompanied by a decrease of the amplitude and coherence of each mode. We also observe a crossover from a hard to a soft onset of the auto-oscillations with increasing wire width. The amplitude of auto-oscillations rapidly decreases with increasing temperature suggesting that interactions of the phase-coherent auto-oscillatory modes with incoherent thermal magnons play an important role in suppression of the auto-oscillatory dynamics. Our measurements in this work set the upper limit on the dimensions of an individual spin Hall oscillator and elucidate the mechanisms leading to suppression of coherent auto-oscillations with increasing oscillator size.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-flavor, full momentum space neutrino spin oscillations in neutron star mergers

In the presence of anisotropic neutrino and antineutrino fluxes, the quantum kinetic equations drive coherent oscillations in neutrino helicity, frequently referred to as spin oscillations. These oscillations depend directly on the absolute mass scale and Majorana phase, but are usually too transient to produce important effects. In this paper we present a full momentum-space analysis of Majorana neutrino spin oscillations in a snapshot of a three-dimensional neutron star merger simulation. We find an interesting angular dependence that allows for that resonant and adiabatic oscillations to occur along specific directions in a large volume of the merger remnant. The solid angle spanned by these directions is extremely narrow in general. We then analyze spin transformation in the presence of flavor transformation by characterizing how the effect's resonance and timescale change during a fast flavor instability. For this analysis, we derive a generalized resonance condition that poses a restrictive requirement for resonance to exist in any flavor channel. Finally, we determine that spin oscillations at all locations in the merger snapshot have a length scale that is too large for significant oscillations to be expected even where there exist resonant and adiabatic directions.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of Synchronization between Two Quantum van der Pol Oscillators in Trapped Ions

Synchronization is a hallmark of collective behavior that emerges when nonlinear systems interact, spanning scales from mechanical oscillators to planetary orbits. As a universal phenomenon, it underpins the study of complex systems and has far-reaching technological implications. While classical synchronization has a long and rich history, it has not been observed experimentally between multiple quantum limit-cycle oscillators despite a decade of theoretical investigations. We realize synchronization between two quantum van der Pol oscillators by engineering dissipation in a mixed-isotope trapped-ion quantum simulator. The synchronized state is encoded in a fixed relative phase between the oscillators that is inaccessible to individual measurements and revealed only through joint readout of both oscillators, in stark contrast to the system in the (deterministic) classical limit where synchronization can be observed via individual phase measurements. We further show that the relative phase can be precisely controlled and that the chain of two oscillators can synchronize to an external field, suggesting applications in sensing. Our results provide a promising pathway for studying more complex synchronized quantum dynamics beyond two oscillators, where a theoretical treatment becomes increasingly challenging, and it remains to be understood whether genuinely quantum features persist in such cases.

Liu, Jiarui↗

Forced Power Systems Oscillations Due to Cyberattacks: Threats, Detection and Partial Mitigation

Forced oscillations in power systems can be caused by misconfigured controllers at generator stations. They can also be caused by cyberattacks against the exciters or governors. This paper explores the effects of forced oscillations from cyberattacks on generator excitation and governor systems and the effectiveness of a novel control system for a static var compensator in mitigating those oscillations to enhance transmission system resilience. A brief overview of oscillations, especially forced oscillations, within power systems is presented, along with an overview of cyberattacks on power systems. This paper also examines and implements FACTS devices to partially mitigate the forced oscillations created by cyberattacks by reducing the magnitude of the oscillations caused by the attack. The proposed approach is more effective against attacks targeting exciters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of Hopfield Networks Based on Superconducting Coupled Oscillators

The global energy shortage has driven the development of many energy-efficient computational platforms beyond Moore's law, among which brain-inspired neuromorphic computing is one of the promising solutions. Associative memory and pattern recognition are important computations solved by brain-inspired Hopfield networks. Classical Hopfield networks store memories via fixed point attractors of their dynamics. In oscillatory Hopfield networks, these attractors are replaced by periodic orbits. Here, we design an oscillatory Hopfield network based on coupled superconducting oscillators. We first employ a mathematical phase reduction approach to map networks of coupled superconducting rapid single flux quantum (RSFQ) ring oscillators to coupled Kuramoto phase-oscillator networks. We use this theory to numerically optimize the hardware's mutual inductances in order to directly match the phase-reduced superconducting oscillators to a model of phase-oscillator-based Hopfield networks. The resulting network can store multiple oscillatory phase-locked memory patterns and recover the patterns based on the initial phase conditions. As different pattern recognition tasks, or learning, require tunable connectivity strengths between the oscillatory nodes, we further employ a coupler circuit that enables tuning the coupling strength between two oscillators by applying an external flux. We demonstrate the functionality of our design through numerical simulations of a small example network with oscillators operating at 86 GHz and recognizing patterns within 10 ns. Our approach enables the learning and retrieval of dynamical memory patterns with a wide range of applications where rhythmic dynamic output is beneficial.

Cheng, Ran↗

Latest Three Flavor Neutrino Oscillation Results from the NOvA Experiment.

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. It is designed primarily to constrain neutrino oscillation parameters such as the atmospheric mass squared splitting, $\Delta m^2_{32}$, the mixing angle, $\theta_{23}$, neutrino mass hierachy, and the CP-violating phase, $\delta_{CP}$, using $\nu_\mu \ (\bar{\nu}_\mu)$ disappearance and $\nu_e \ (\bar{\nu}_e)$ appearance data. NOvA receives a high purity instense beam of neutrinos and anti-neutrinos from Fermilab's Neutrinos at Main Injector (NuMI) beamline. The NOvA near detector (ND) observes un-oscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and beam $\nu_e \ (\bar{\nu}_e)$ events, while the far detector (FD), which is situated 810 km away from the near detector, records un-oscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and oscillated $\nu_e \ (\bar{\nu}_e)$ events. The best fit values of the oscillation parameters are extracted by performing a joint fit of the far detector predicted events to data from $\nu_\mu \to \nu_\mu$, $\bar{\nu}_\mu \to \bar{\nu}_\mu$, $\nu_\mu \to \nu_e$, and $\bar{\nu}_\mu \to \bar{\nu}_e$ oscillation channels. We present latest joint fit results from NOvA based on a neutrino-beam exposure of $27.24 \times 10^{20}$ POT and an anti-neutrino beam exposure of $12.55\times 10^{20}$ POT and improved simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Three-Flavor Neutrino Oscillations at NOvA

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. It is designed primarily to constrain neutrino oscillation parameters such as the atmospheric mass squared splitting, $\Delta m^2_{32}$, the mixing angle, $\theta_{23}$, neutrino mass hierachy, and the CP-violating phase, $\delta_{CP}$, using $\nu_\mu \ (\bar{\nu}_\mu)$ disappearance and $\nu_e \ (\bar{\nu}_e)$ appearance data. NOvA receives a high purity 900 KW instense beam of neutrinos and anti-neutrinos from Fermilab's Neutrinos at Main Injector (NuMI) beamline. NOvA used functionally identical finely granulated liquid scintillation detectors, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector observes un-oscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and beam $\nu_e \ (\bar{\nu}_e)$ events, while the far detector, which is situated 809 km away from the near detector, records un-oscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and oscillated $\nu_e \ (\bar{\nu}_e)$ events. We will discuss the neutrino oscillation analysis strategy at NOvA and the latest three-flavor oscillation results from 10 years of NOvA data in this talk.

43 PARTICLE ACCELERATORS↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

Electron plasma oscillations associated with type 3 radio emissions and solar electrons

An extensive study of the IMP-6 and IMP-8 plasma and radio wave data was performed to try to find electron plasma oscillations associated with type III radio noise bursts and low-energy solar electrons. It is shown that electron plasma oscillations are seldom observed in association with solar electron events and type III radio bursts at 1.0 AU. For the one case in which electron plasma oscillations are definitely produced by the electrons ejected by the solar flare the electric field strength is relatively small. Electromagnetic radiation, believed to be similar to the type III radio emission, is observed coming from the region of the more intense electron plasma oscillations upstream. Quantitative calculations of the rate of conversion of the plasma oscillation energy to electromagnetic radiation are presented for plasma oscillations excited by both solar electrons and electrons from the bow shock. These calculations show that neither the type III radio emissions nor the radiation from upstream of the bow shock can be adequately explained by a current theory for the coupling of electron plasma oscillations to electromagnetic radiation.

Gurnett, D. A.↗

Thrust oscillations of the Space Shuttle solid rocket Booster motor during static tests

Thrust oscillations have occurred during static tests of Space Shuttle Booster solid rocket motors. These oscillations in measured axial thrust occurred primarily near 15 Hz; these oscillations late in the motor burn reach magnitudes up to approximately + or - 3% of motor thrust. The phenomenon has consistently occurred on the four demonstration motors which have been static tested and appears to be associated with small amplitude, 15 Hz pressure oscillations inside the motor. The source of the pressure oscillations is thought to be associated with the fundamental longitudinal acoustic resonance of the motor at 15 Hz. These thrust oscillations potentially can impact the design of the Space Shuttle vehicle structure. The demonstration motors have been instrumented with an array of transducers to aid in understanding the phenomenon. In addition to measuring axial and lateral thrust of the motor, pressure transducers were located to measure chamber pressure oscillations at the forward dome. Accelerometers and extensometers have measured motions of the structure. A modal survey was conducted on a fired motor to identify its structural dynamic characteristics, and these data were used to validate mathematical models of the motor in the static test facility.

Mason, D. R.↗