Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optomechanics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development and design of an airborne autonomous wavemeter for laser tuning

The development and design of an instrument for making water vapor Differential Absorption Lidar (DIAL) measurements from a down-looking airborne platform are described. The wavemeter device for this NASA-LASE (Lidar Atmospheric Sensing Experiment) project involves a classical Fabry-Perot interferometer approach. The interoferometer design, breadboard design, data retrieval algorithms, and errors are examined, and the design of the airborne instrument is discussed, including the illumination and imaging considerations, optomechanical component arrangement, electronic configuration, and proposed calibration technique.

Goad, Joseph H., Jr.↗

Glass sample preparation and performance investigations

This final report details the work performed under this delivery order from April 1991 through April 1992. The currently available capabilities for integrated optical performance modeling at MSFC for large and complex systems such as AXAF were investigated. The Integrated Structural Modeling (ISM) program developed by Boeing for the U.S. Air Force was obtained and installed on two DECstations 5000 at MSFC. The structural, thermal and optical analysis programs available in ISM were evaluated. As part of the optomechanical engineering activities, technical support was provided in the design of support structure, mirror assembly, filter wheel assembly and material selection for the Solar X-ray Imager (SXI) program. As part of the fabrication activities, a large number of zerodur glass samples were prepared in different sizes and shapes for acid etching, coating and polishing experiments to characterize the subsurface damage and stresses produced by the grinding and polishing operations. Various optical components for AXAF video microscope and the x-ray test facility were also fabricated. A number of glass fabrication and test instruments such as a scatter plate interferometer, a gravity feed saw and some phenolic cutting blades were fabricated, integrated and tested.

Johnson, R. Barry↗

NASA/LMSC instrument design and fabrication

The topics addressed are: (1) class-10 flight test program; (2) class system requirements; (3) Doppler wind velocity measurement; (4) systems specifications rational; (5) signal-to-noise equation for remote atmospheric sensing laser velocimeter; (6) variation of signal-to-noise ratios and true wind velocity with distance; (7) velocity error as a function of signal-to-noise ratio, with turbulence; and (8) final class optomechanical design on NASA B/737.

Targ, Russel↗

Linear analysis of opto-mechanical systems

A general framework is presented for the matrix-form, linear optical model analysis of controlled optomechanical systems; the models are conjoined with linear models of structures and controls to compute system performance as a function of optics, structures, and control parameters. Covariance analysis, optimization, and estimation/simulation are used. Attention is given to a tolerancing example for the Hubble Space Telescope's Wide Field and Planetary Camera, which involves the creation of a linear model of residual pupil shear.

Redding, David C.↗

Geosynchronous orbiting Nadir Etalon Sounding Spectrometer instrument concept for temperature, moisture and trace species, GeoNESS

The paper describes the salient features of the Geosynchronous orbiting Nadir Etalon Sounding Spectrometer (GeoNESS) designed for applications from geosynchronous orbit for nadir sounding temperature, moisture, and trace species analyses in the troposphere and the lower stratosphere. Particular attention is given to the optics of GeoNESS, the optomechanical design, the cooling systems, the measurement approach used in GeoNESS, the channel selection, and the calibration considerations.

Kumer, J. B.↗

Apparatus Translates Crossed-Laser-Beam Probe Volume

Optomechanical apparatus translates probe volume of crossed-beam laser velocimeter or similar instrument while maintaining optical alignment of beams. Measures velocity, pressure, and temperature of flowing gas at several locations. Repeated tedious realignments no longer necessary. Designed to accommodate stimulated-Raman-gain spectrometer for noninvasive measurement of local conditions in flowing gas in supersonic wind tunnel. Applicable to other techniques like coherent anti-Stokes Raman spectroscopy involving use of laser beams crossed at small angles (10 degrees or less).

Herring, Gregory C.↗

Almaz

The basic data of the automatic space station ALMAZ-1B is overviewed, including the orbit parameters and maximum power. The principal technical characteristics of its remote sensing equipment is listed for the synthetic aperture and side-looking radar, optoelectronic equipment for stereophotography, high-resolution electronic scanner, middle-resolution optomechanical scanner, spectroradiometer for ocean satellite monitoring, and information transmission and reception. The main objectives and uses of the ALMAZ-1B information are cartography, land monitoring, geology, ecological monitoring, oceanology, pilotage, fishery, and information supply during an emergency such as controlling situation in natural disasters.

Viter, V.↗

UV laser long-path absorption spectroscopy

Long path Differential Optical Absorption Spectroscopy (DOAS) using a picosecond UV laser as a light source was developed in our institute. Tropospheric OH radicals are measured by their rotational absorption lines around 308 nm. The spectra are obtained using a high resolution spectrograph. The detection system has been improved over the formerly used optomechanical scanning device by application of a photodiode array which increased the observed spectral range by a factor of 6 and which utilizes the light much more effectively leading to a considerable reduction of the measurement time. This technique provides direct measurements of OH because the signal is given by the product of the absorption coefficient and the OH concentration along the light path according to Lambert-Beers law. No calibration is needed. Since the integrated absorption coefficient is well known the accuracy of the measurement essentially depends on the extent to which the OH absorption pattern can be detected in the spectra. No interference by self generated OH radicals in the detection lightpath has been observed. The large bandwidth (greater than 0.15 nm) and the high spectral resolution (1.5 pm) allows absolute determination of interferences by other trace gas absorptions. The measurement error is directly accessible from the absorption-signal to baseline-noise ratio in the spectra. The applicability of the method strongly depends on visibility. Elevated concentrations of aerosols lead to considerable attenuation of the laser light which reduces the S/N-ratio. In the moderately polluted air of Julich, where we performed a number of OH measurement spectra. In addition absorption features of unidentified species were frequently detected. A quantitative deconvolution even of the known species is not easy to achieve and can leave residual structures in the spectra. Thus interferences usually increase the noise and deteriorate the OH detection sensitivity. Using diode arrays for sensitive absorption measurements some specific problems of those detectors have to be solved experimentally (i.e. fixed pattern noise, dark signal noise, nonuniform efficiency of individual elements, spatial sensitivity variations). In order to improve the low spatial resolution we performed laboratory studies using a multiple reflection cell to convert the long path technique to a real in situ point measurement. Under the conditions of field experiments in Julich residual absorbance signals at present are about 1.5x10(exp -4) corresponding to an OH detection sensitivity of 2x10(exp 6) OH/cm(exp 3) using a light path of 5.8 km. Total integration times for one measurement point vary between a few minutes and an hour.

Dorn, Hans-Peter↗

SXI Prototype mirror mount

This final report describes the work performed from June 1993 to January 1995. The purpose of this contract was to provide optomechanical engineering and fabrication support to the Solar X-ray Imager (SXI) program in the areas of mirror, optical bench and camera assemblies of the telescope. The Center for Applied Optics (CAO) worked closely with the Optics and S&E technical staff of MSFC to develop and investigate the most viable and economical options for the design and fabrication of a number of parts for the various telescope assemblies. All the tasks under this delivery order have been successfully completed within budget and schedule.

Source record↗

Characteristics of the HYDICE sensor

In 1992, in an effort to significantly improve knowledge in the field of hyperspectral imagery, the Naval Research Laboratories defined a set of requirements for a new generation sensor. Construction of this instrument, designated HYDICE, has recently been completed at Hughes Danbury Optical Systems. It is currently being flight tested on a Convair 580 operated by ERIM. This paper reports on some of the performance parameters measured to date. The majority of these are derived from laboratory test data. Optomechanical parameters include MTF, spatial co-registration, 'smile', spectral profile and spectral calibration. Detector-related parameters include system responsivity, signal to noise ratio, radiometric stability and gain linearity. The results are compared with the original system performance predictions.

Basedow, R. W.↗

Fast Light-Sheet Scanner

Optomechanical apparatus maintains sheet of pulsed laser light perpendicular to reference axis while causing sheet of light to translate in oscillatory fashion along reference axis. Produces illumination for laser velocimeter in which submicrometer particles entrained in flow illuminated and imaged in parallel planes displaced from each other in rapid succession. Selected frequency of oscillation range upward from tens of hertz. Rotating window continuously shifts sheet of light laterally while maintaining sheet parallel to same plane.

Hunter, William W., Jr.↗

SXI prototype mirror mount

The purpose of this contract was to provide optomechanical engineering and fabrication support to the Solar X-ray Imager (SXI) program in the areas of mirror, optical bench and camera assemblies of the telescope. The Center for Applied Optics (CAO) worked closely with the Optics and S&E technical staff of MSFC to develop and investigate the most viable and economical options for the design and fabrication of a number of parts for the various telescope assemblies. All the tasks under this delivery order have been successfully completed within budget and schedule. A number of development hardware parts have been designed and fabricated jointly by MSFC and UAH for the engineering model of SXI. The major parts include a nickel electroformed mirror and a mirror mount, plating and coating of the ceramic spacers, and gold plating of the contact rings and fingers for the camera assembly. An aluminum model of the high accuracy sun sensor (HASS) was also designed and fabricated. A number of fiber optic tapers for the camera assembly were also coated with indium tin oxide and phosphor for testing and evaluation by MSFC. A large number of the SXI optical bench parts were also redesigned and simplified for a prototype telescope. These parts include the forward and rear support flanges, front aperture plate, the graphite epoxy optical bench and a test fixture for the prototype telescope. More than fifty (50) drawings were generated for various components of the prototype telescope. Some of these parts were subsequently fabricated at UAH machine shop or at MSFC or by the outside contractors. UAH also provide technical support to MSFC staff for a number of preliminary and critical design reviews. These design reviews included PDR and CDR for the mirror assembly by United Technologies Optical Systems (UTOS), and the program quarterly reviews, and SXI PDR and CDR. UAH staff also regularly attended the monthly status reviews, and made a significant number of suggestions to improve the design, assembly and alignment of the telescope. Finally, a high level assembly and alignment plan for the entire telescope was prepared by UAH. This plan addresses the sequence of assembly, the required assembly and alignment tolerances, and the methods to verify the alignment at each step during the assembly process. This assembly and alignment plan will be used to assemble and integrate the engineering model (EM) of the telescope. Later on, based on this plan more detailed assembly and alignment procedures will be developed for the lower-level assemblies of SXI.

Source record↗

Compact Color Schlieren Optical System

Compact, rugged optical system developed for use in rainbow schlieren deflectometry. Features unobscured telescope with focal-length/aperture-width ratio of 30. Made of carefully selected but relatively inexpensive parts. All of lenses stock items. By-product of design is optical system with loose tolerances on interlens spacing. One of resulting advantages, insensitivity to errors in fabrication of optomechanical mounts. Another advantage is ability to compensate for some of unit-to-unit variations inherent in stock lenses.

Buchele, Donald R.↗

Lightweight Aluminum Mirrors Using Foam Core Sandwich Construction

The possible use of all aluminum mirrors made from thin faceplates supported by aluminum foam is explored from an optomechanical design and fabrication perspective. Foam mirrors can be relatively cheaply and easily made using conventional foam fabrication and diamond turning; such a mirror recently flew for the first time on the Stardust mission. The proposed structural concept is highly weight efficient and should not be prone to quilting. The weight and structural stability of such mirrors is presented, along with plans underway at GSFC for developing this concept.

Content, D.↗

Design of Mechanisms for Deployable, Optical Instruments: Guidelines for Reducing Hysteresis

This paper is intended to facilitate the development of deployable, optical instruments by providing a rational approach for the design, testing, and qualification of high-precision (i.e., low-hysteresis) deployment mechanisms for these instruments. Many of the guidelines included herein come directly from the field of optomechanical engineering, and are, therefore, neither newly developed guidelines, nor are they uniquely applicable to the design of high-precision deployment mechanisms. This paper is to be regarded as a guide to design and not a set of NASA requirements, except as may be defined in formal project specifications. Furthermore, due to the rapid pace of advancement in the field of precision deployment, this paper should be regarded as a preliminary set of guidelines. However, it is expected that this paper, with revisions as experience may indicate to be desirable, might eventually form the basis for a set of uniform design requirements for high-precision deployment mechanisms on future NASA space-based science instruments.

Lake, Mark S.↗

Overcoming Dynamic Disturbances in Imaging Systems

We develop and discuss a methodology with the potential to yield a significant reduction in complexity, cost, and risk of space-borne optical systems in the presence of dynamic disturbances. More robust systems almost certainly will be a result as well. Many future space-based and ground-based optical systems will employ optical control systems to enhance imaging performance. The goal of the optical control subsystem is to determine the wavefront aberrations and remove them. Ideally reducing an aberrated image of the object under investigation to a sufficiently clear (usually diffraction-limited) image. Control will likely be distributed over several elements. These elements may include telescope primary segments, telescope secondary, telescope tertiary, deformable mirror(s), fine steering mirror(s), etc. The last two elements, in particular, may have to provide dynamic control. These control subsystems may become elaborate indeed. But robust system performance will require evaluation of the image quality over a substantial range and in a dynamic environment. Candidate systems for improvement in the Earth Sciences Enterprise could include next generation Landsat systems or atmospheric sensors for dynamic imaging of individual, severe storms. The technology developed here could have a substantial impact on the development of new systems in the Space Science Enterprise; such as the Next Generation Space Telescope(NGST) and its follow-on the Next NGST. Large Interferometric Systems of non-zero field, such as Planet Finder and Submillimeter Probe of the Evolution of Cosmic Structure, could benefit. These systems most likely will contain large, flexible optomechanical structures subject to dynamic disturbance. Furthermore, large systems for high resolution imaging of planets or the sun from space may also benefit. Tactical and Strategic Defense systems will need to image very small targets as well and could benefit from the technology developed here. We discuss a novel speckle imaging technique with the potential to separate dynamic aberrations from static aberrations. Post-processing of a set of image data, using an algorithm based on this technique, should work for all but the lowest light levels and highest frequency dynamic environments. This technique may serve to reduce the complexity of the control system and provide for robust, fault-tolerant, reduced risk operation. For a given object, a short exposure image is "frozen" on the focal plane in the presence of the environmental disturbance (turbulence, jitter, etc.). A key factor is that this imaging data exhibits frame-to-frame linear shift invariance. Therefore, although the Point Spread Function is varying from frame to frame, the source is fixed; and each short exposure contains object spectrum data out to the diffraction limit of the imaging system. This novel speckle imaging technique uses the Knox-Thompson method. The magnitude of the complex object spectrum is straightforward to determine by well-established approaches. The phase of the complex object spectrum is decomposed into two parts. One is a single-valued function determined by the divergence of the optical phase gradient. The other is a multi-valued function determined by the circulation of the optical phase gradient-"hidden phase." Finite difference equations are developed for the phase. The novelty of this approach is captured in the inclusion of this "hidden phase." This technique allows the diffraction-limited reconstruction of the object from the ensemble of short exposure frames while simultaneously estimating the phase as a function of time from a set of exposures.

Young, Eric W.↗

Subsystem Imaging Performance and Modeling of the Infrared Multi-Object Spectrograph

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter). IRMOS is a near-IR (0.8 - 2.5 micron) spectrograph with low to mid resolution (R=lambda/delta, lambda = 300 - 3800). The IRMOS spectrograph produces simultaneous spectra of - 100 objects in its 2.8 x 2.0 arc-min field of view using a commercial MEMS multi-mirror array device (MMA). The IRMOS optical design consists of two imaging systems, or "stages." The focal reducer, stage one, images the focal plane of the telescope onto the MMA. The spectrograph, stage two, images the MMA onto the detector. We describe the breadboard alignment method and imaging and scattered light performance for both the focal reducer and spectrograph. This testing provides verification of the optomechanical alignment method, and a measurement of the contribution of scattered light in the system due to mirror small scale surface error. After the stage I and 2 optics are integrated with the instrument, our test results will make it possible to distinguish between scattered light from the mirrors and the MMA. Image testing will be done at four wavelengths in the visible and near-IR. A mercury-argon pencil lamp will provide spectral lines at 546.1 and 1012 nm, and a blackbody radiation source lines at 1600 and 2200 nm. A CCD camera will be used as a detector for the visible wavelengths, and an IR photodiode will be used for the IR wavelengths. We compare our data with a theoretical analysis using a commercial software package. Mirror surface error is modeled by treating each surface as a superposition of various gratings (e.g., diamond turning tool marks, features due to the impurities of Al 6061, and periodic mid-frequency errors due to drift during machining).

Connelly, Joseph A.↗

Optical Testing of Diamond Machined, Aspheric Mirrors for Groundbased, Near-IR Astronomy

The Infrared Multi-Object Spectrometer (IRMOS) is a facility-class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8-2.5 micron) spectrometer and operates at approximately 80 K. The 6061-T651 aluminum bench and mirrors constitute an athermal design. The instrument produces simultaneous spectra at low- to mid-resolving power (R=lambda/delta lambda= 300-3000) of approximately 100 objects in its 2.8 x 2.0 arcmin field. We describe ambient and cryogenic optical testing of the IRMOS mirrors across a broad range in spatial frequency (figure error, mid-frequency error, and microroughness). The mirrors include three rotationally symmetric, off-axis conic sections, one off-axis biconic, and several flat fold mirrors. The symmetric mirrors include convex and concave prolate and oblate ellipsoids. They range in aperture from 94x86 mm to 286x269 mm and in f-number from 0.9 to 2.4. The biconic mirror is concave and has a 94x76 mm aperture, R(sub x)=377 mm, k(sub x)=0.0778, R(sub y)=407 mm, and k(sub y)=0.1265 and is decentered by -2 mm in X and 227 mm in Y. All of the mirrors have an aspect ratio of approximately 6:1. The surface error fabrication tolerances are less than 10 nm RMS microroughness, 'best effort' for mid-frequency error, and less than 63.3 nm RMS figure error. Ambient temperature (approximately 293 K) testing is performed for each of the three surface error regimes, and figure testing is also performed at approximately 80 K. Operation of the ADE Phaseshift MicroXAM white light interferometer (micro-roughness) and the Bauer Model 200 profilometer (mid-frequency error) is described. Both the sag and conic values of the aspheric mirrors make these tests challenging. Figure testing is performed using a Zygo GPI interferometer, custom computer generated holograms (CGH), and optomechanical alignment fiducials. Cryogenic CGH null testing is discussed in detail. We discuss complications such as the change in prescription with temperature and thermal gradients. Correction for the effect of the dewar window is also covered. We discuss the error budget for the optical test and alignment procedure. Data reduction is accomplished using commercial optical design and data analysis software packages. Results from CGH testing at cryogenic temperatures are encouraging thus far.

Chambers, V. John↗