Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical pulse shaping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

133 records · Page 8

Determining Key Factors for the Open-Loop Control of Molecular Fragmentation Using Shaped Strong Fields

Pulse shaping has long been employed for tailoring femtosecond laser pulses to study and control the fragmentation of polyatomic molecules. In many cases, a physical explanation connecting the properties of the field to the observed control is difficult to ascertain. We utilized 80 bit binary spectral phase functions to parametrize and map the search space, gaining insight into which pulse parameters most impact the ion yield and fragmentation pattern for the relatively large triethylamine [N(C 2 H 5 ) 3 ] molecule. Pulse structures used to control the m/z 86 branching ratio beyond a simple intensity dependence are identified and compared to pump–probe results. All of these findings are explained in terms of control via a dissociative Rydberg state in the neutral molecule. This methodology may be used to discover new control mechanisms and shed light onto which pulse parameters most influence the interaction between strong field lasers and matter.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Collinear dual-pulse laser optical breakdown and energy deposition

A non-equilibrium model for laser-generated plasmas is used to represent collinear dual nano-second-pulse interactions. In the specific case considered, the breakdown is initiated with an ultraviolet (UV) laser pulse at 266 nm, which pre-ionizes the gas, and it is followed by a near-infrared (NIR) pulse at 1064 nm, which deposits significant energy into the ionized mixture. The model is validated against corresponding experiments, and simulation results are interrogated to understand key features of the plasma-kernel dynamics and the post-discharge hydrodynamics. The hydrodynamics of the non-equilibrium plasma is governed by the two-temperature Navier–Stokes equations accounting for both multiphoton ionization and inverse bremsstrahlung. The interaction between the laser beam and the plasma is modeled based on the radiative transfer equation. The temporal and spatial offsets of the two pulses can generate ionization kernels with different topology and dynamics. It is shown that the UV pre-ionization pulse can tailor the plasma region, leading to a larger ionized volume than would occur for a single-pulse breakdown, and it increases the efficiency of the energy deposition for the following NIR discharge. Vorticity in the early post-discharge phase is generated via baroclinic torque from the misalignment of the radial gradient of density (sudden gas expansion) and the strong pressure gradient (initiated by energy deposition from the laser beam). It is predicted that the collinear dual pulse can be designed to specify the plasma kernel size, shape, and maximum temperature in the breakdown phase, and the initial post-breakdown vorticity and plasma-core decay.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Replacing photomultiplier tubes with silicon photomultipliers for nuclear safeguards applications

Photomultiplier tubes (PMTs) have been used for decades as the default light detection technology for scintillator-based radiation monitors. PMTs come with a handful of disadvantages, however, including large volume usage, fragility, high-voltage requirements, and susceptibility to magnetic fields. Arrays of silicon photomultipliers (SiPMs) are a possible alternative to PMTs providing similar performance while offering improvements in the areas listed. We focus on straightforward “drop-in replacement” evaluations by imposing a single channel output of the SiPM signal and a backend electronics data acquisition and analysis routine identical to that used for PMTs. In the realm of nuclear safeguards, the primary performance metric for gamma spectroscopy is detector resolution, and for neutron detection it is pulse shape discrimination (PSD) to separate neutron and gamma signals. In this work we present the results of replacing a PMT with a 2” x 2” SiPM array mounted, in turn, to the same 2” x 2” cylindrical sodium iodide (NaI) crystal. The ultimate comparison for this gamma spectrometry is confirmation of uranium enrichment standards, ranging from depleted uranium to 93% highly enriched uranium (HEU), by analyzing the resulting spectra with both a simple integral scaling in key energy regions of the spectrum, as well as with the NaIGEM software package. In addition to the gamma spectroscopy work, we will present the latest results on comparing the PSD capabilities of a 4” x 4” SiPM array to a 5” PMT. As with the gamma spectroscopy evaluations, the light detectors are mounted in turn to the same liter-scale organic scintillators. This neutron-focused work includes evaluation of prototype SiPM readout boards with a single output signal summed over 256 individual SiPM pixels, and evident tradeoffs between PSD capability and fast response.

Engineering - Instrumentation related to nuclear s↗

Broadband hard X-ray attosecond pulses from extremely chirped electron beams

Attosecond pulses from free-electron lasers have opened the doors to atomic site-specific studies of bound electronic dynamics on their natural, sub-femtosecond timescales. Key to their success has been electron beam shaping techniques enabling the generation of sub-femtosecond current spikes with peak currents on the order of 10 kA. We demonstrate in an RF linac the generation of current spikes with extreme chirps on the order of 350 MeV/micron, directly competitive with the chirps expected from beam-driven plasma wakefield accelerators. Leveraging chirp-taper compensation, we use these highly chirped beams to generate hard X-ray attosecond pulses with bandwidths exceeding 30 eV, a factor of two beyond previous demonstrations. We simultaneously present the first explicit experimental evidence of chirp-taper compensation in an attosecond XFEL, finding that optimal tapering improves the bandwidth and pulse energy by factors of two and five, respectively, for our conditions. In addition to the immediate utility of such broadband hard X-ray pulses, electron beams with such extreme chirps can be utilized for unique new experimental modalities by performing further compression after the undulators. Such post-lasing compression can enable subsequent superradiant light emission at longer wavelengths, or direct excitation of quantum systems with the beam's intense space-charge field for unique attosecond pump-probe possibilities.

43 PARTICLE ACCELERATORS↗

GRAPH — an readout ASIC for large MCP based detectors

We present a programmable 16 channel, mixed signal, low power readout ASIC, having the project historically named Gigasample Recorder of Analog waveforms from a PHotodetector (GRAPH). It is designed to read large aperture single photon imaging detectors using micro channel plates for charge multiplication, and measuring the detector's response on crossed strips anodes to extrapolate the incoming photon position. Each channel consists of a fast, low power and low noise charge sensitive amplifier, which provides a myriad of coarse and fine programmable options for gain and shaping settings. Further, the amplified signal is recorded using, to our knowledge novel, the Hybrid Universal sampLing Architecture (HULA) ADC. A kind of mixed signal double buffer memory, that enables concurrent waveform recording, and selected event digitized data extraction. The sampling frequency is freely adjustable between few kHz up to 125 MHz, while the chip's internal digital memory holds a history 2048 samples for each channel, with a digital headroom of 12 bits. An optimized region of interest sample-read algorithm allows to extract the information just around the event pulse peak, while selecting the next event, thus substantially reducing the operational dead time. The chip is designed in 130 nm TSMC CMOS technology, and its power consumption is around 47 mW per channel.

47 OTHER INSTRUMENTATION↗

Three-dimensional modeling of a plasma in a strong azimuthal magnetic field

Three-dimensional magnetohydrodynamic (MHD) simulations are able to model the generation of disc-shaped plasma, driven by laser ablation from a current carrying rod in a pulsed-power machine producing azimuthal magnetic fields of 2–3 MG. The plasma at such extreme conditions is unique in that the parameter space for the plasma β and Hall parameter χ transition from below unity to greater than unity at different stages of the plasma generation. In simulations, the formation of the plasma disc in the azimuthal direction, is driven by heat flux from the laser spot and depends on the set of transport coefficients used in simulations. The most recent set of transport coefficients leads to the formation of plasma ejecta at the back end of the rod, that qualitatively matches experiments. Specifically, the cross-gradient Nernst effect, which twists magnetic field, is shown to have a large effect on the shape of the back end ejecta. In the direction along the axis of the rod there is propagation of perturbations from the disc as observed in experiments. In simulations the period of temperature perturbations is in good agreement with experimental results. Furthermore, an instability due to coupling of heat flux and the magnetic field advection provides a possible explanation for perturbation growth along the axis of the rod, and the instability growth rate is consistent with experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗