Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Nonperturbative Zou-Wang-Mandel effect

The Zou-Wang-Mandel (ZWM) effect is a remarkable consequence of photon indistinguishability and continuous-variable entanglement in which an optical phase shift is imprinted on photonic modes associated with optical paths that that do not pass through the phase shift source. By bringing the canonical formalism of continuous-variable Gaussian states to bear on the mode-structure of the ZWM experiment, we show that the physical consequence of implementing optical path identity is a renormalization of quadrature squeezing which governs the entanglement of four effective optical modes. Nonperturbative expressions for the ZWM interference patterns and normalized first-order coherence function are derived. Generalizations to $\mathscr{H}$-graph states with more than four modes directly follow from the general method used to analyze the minimal example. Here, we show that a ZWM interferometer with a laser-seeded signal mode, which estimates an idler phase shift by detecting photons that did not propagate through the phase shift, exhibits an optimal sensitivity comparable to that of a laser-seeded SU(1,1) interferometer if path identity is implemented with high fidelity.

74 ATOMIC AND MOLECULAR PHYSICS↗

Cosmic axions revealed via amplified modulation of the ellipticity of a laser

We propose a new axion dark matter detection strategy that employs optical readout of laser beam ellipticity modulations caused by axion-induced electric fields in a microwave cavity, using electro-optic (EO) crystals, enhanced by externally injected radio-frequency (rf) power. Building upon the variance-based probing method [Phys. Rev. D 107, 103005 (2023).], we extend this concept to the optical domain: A weak probe laser interacts with an EO crystal coupled to the resonant microwave cavity field at cryogenic temperatures, and the axion-induced electric field is revealed through induced ellipticity. The injected rf signal coherently interferes with that of the axion field, amplifying the optical response and significantly improving sensitivity. While our EO-based method employs a Fabry-Pérot resonator, we do not require Michelson interferometers. Our method, hence, enables compact, high-frequency axion searches, across the 0.5–50 GHz range. Operating at cryogenic temperatures not only suppresses thermal backgrounds, but, critically, allows the probing method to mitigate the quantum noise. This approach offers a scalable path forward for axion detection over the ∼(few−200) μ⁢eV mass range—covering the preferred parameter space for the postinflationary Peccei-Quinn axion dark matter—using compact, tunable systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Time-Resolved Leader Spectra Associated With a Downward Terrestrial Gamma-Ray Flash Detected at the Telescope Array Surface Detector

Optical emissions associated with Terrestrial Gamma ray Flashes (TGFs) have recently become important subjects in space-based and ground-based observations as they can help us understand how TGFs are produced during thunderstorms. In this paper, we present the first time-resolved leader spectra of the optical component associated with a downward TGF. The TGF was observed by the Telescope Array Surface Detector (TASD) simultaneously with other lightning detectors, including a Lightning Mapping Array (LMA), an INTerFerometer (INTF), a Fast Antenna (FA), and a spectroscopic system. The spectroscopic system recorded leader spectra at 29,900 frames per second (33.44 μs time resolution), covering a spectral range from 400 to 900 nm, with 2.1 nm per pixel. The recordings of the leader spectra began 11.7 ms before the -18 kA return stroke and at a height of 2.37 km above the ground. These spectra reveal that optical emissions of singly ionized nitrogen and oxygen occur between 167 μs before and 267 μs after the TGF detection, while optical emissions of neutrals (H I, 656 nm; N I, 744 nm, and O I, 777 nm) occur right at the moment of the detection. The time-dependent spectra reveal differences in the optical emissions of lightning leaders with and without downward TGFs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tunable coherent light filter for optical sensing and imaging

Systems and methods are provided for filtering coherent infrared light from a thermal background for protection of infrared (IR) imaging arrays and detection systems. A Michelson interferometer is used for coherent light filtering. In an implementation, a system includes a fixed mirror, a beam splitter, and a moving mirror which can be controlled translationally, as well as tip/tilt. The Michelson interferometer may be used as an imaging system. For imaging applications, a system may comprise a tunable array of micro-electromechanical systems (MEMS) mirrors. A mid-wave IR interferometer with electronic feedback and MEMS mirror array is provided.

Wasserman, David↗

457-nm radiation source based on a diode laser for precision spectroscopy of magnesium atoms

We report on the development of a highly stable source of 457-nm radiation based on a diode laser and a tapered amplifier operating in a double-pass scheme. The diode laser frequency was stabilised by a high-Q reference Fabry – Perot interferometer and doubled in a PPSLT nonlinear crystal placed in an enhancement cavity. At a maximum output power of 200 mW at a wavelength of 457 nm, the laser linewidth was less than 5 kHz. The radiation source operation was demonstrated in experiments on precision spectroscopy of cold magnesium atoms in a magneto-optical trap. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aero-Optics of Hypersonic Turbulent Boundary Layers

Aero-optics refers to optical distortions due to index-of-refraction gradients that are induced by aerodynamic density gradients. At hypersonic flow conditions, the bulk velocity is many times the speed of sound and density gradients may originate from shock waves, compressible turbulent structures, acoustic waves, thermal variations, etc. Due to the combination of these factors, aero-optic distortions are expected to differ from those common to sub-sonic and lower super-sonic speeds. This report summarizes the results from a 2019-2022 Laboratory Directed Research and Development (LDRD) project led by Sandia National Laboratories in collaboration with the University of Notre Dame, New Mexico State University, and the Georgia Institute of Technology. Efforts extended experimental and simulation methodologies for the study of turbulent hypersonic boundary layers. Notable experimental advancements include development of spectral de-aliasing techniques for highspeed wavefront measurements, a Spatially Selective Wavefront Sensor (SSWFS) technique, new experimental data at Mach 8 and 14, a Quadrature Fringe Imaging Interferometer (QFII) technique for time-resolved index-of-refraction measures, and application of QFII to shock-heated air. At the same time, model advancements include aero-optic analysis of several Direct Numerical Simulation (DNS) datasets from Mach 0.5 to 14 and development of wall-modeled Large Eddy Simulation (LES) techniques for aero-optic predictions. At Mach 8 measured and predicted root mean square Optical Path Differences agree within confidence bounds but are higher than semi-empirical trends extrapolated from lower Mach conditions. Overall, results show that aero-optic effects in the hypersonic flow regime are not simple extensions from prior knowledge at lower speeds and instead reflect the added complexity of compressible hypersonic flow physics.

36 MATERIALS SCIENCE↗

Fiber-optic silicon Fabry–Perot interferometric bolometer with improved detection limit for magnetic confinement fusion

Fiber-optic bolometers (FOBs) intended for plasma radiation measurement in magnetically confined fusion have been previously developed using a silicon pillar that functions as both a Fabry–Perot interferometer (FPI) for temperature measurement and an absorber for the radiation. We report an FOB design that can significantly improve the detection sensitivity over earlier designs by engineering the absorber of the FOB. Our design uses the fact that, compared with a silicon pillar, a gold film with the same x-ray absorption thickness will show a much higher temperature rise from a given power density of the radiation. Therefore, the responsivity of an FOB can be improved by attaching a large gold disk to the silicon FPI as the absorber. We have developed a fabrication method for FOBs of such design and obtained an FOB with a 4-µm-thick, 0.6-mm-diameter gold disk attached to a 200-µm-diameter, 100-µm-thick silicon FPI. We have characterized the noise, responsivity, response time, and noise-equivalent power density (NEPD) and compared these with the earlier design where the absorber is mainly the silicon FPI itself. The experimental result suggests that the FOB with the gold disk achieves a responsivity of ∼2.8 mK/(W/m2) and a noise-equivalent-power-density of 0.13 W/m2, which are, respectively, more than nine times larger and six times smaller compared to the FOB using a previous design. Improved NEPD and good absorption over a broad frequency range will make the FOB more attractive for applications in magnetic-confinement fusion devices.

Uddin, Nezam↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Narrow-bandwidth tunable optical filter stabilized by Newton’s rings fringe analysis

The resolution of grating spectrometers is insufficient to resolve many features present in the emission spectra of solid-state quantum emitters. Spectral resolution may be improved by inserting a Fabry–Perot interferometer (FPI) whose length is tuned by a piezoelectric actuator. Yet piezo creep and thermal fluctuations cause instability that makes this solution unsuitable for measurement times longer than tens of seconds. To overcome this challenge, we employ active feedback derived from the Newton’s rings interference pattern formed by the reflection of a single-frequency laser from the FPI cavity. The resulting FPI transmission frequency is stable to within 50 MHz over several hours.

KC, Raju Bhai (ORCID:0000000267406588)↗

Young but fading radio sources: searching for remnants among compact steep-spectrum radio sources

The incidence of young but fading radio sources provides important information on the life cycle of radio emission in radio-loud active galactic nuclei. Despite its importance for constraining the models of radio source evolution, there are no systematic studies of remnants in complete samples of young radio sources. We report results of the study of 18 compact steep-spectrum (CSS) radio sources, selected from the statistically complete B3-VLA (Very Large Array) CSS sample, characterized by a steep optically thin spectrum (α ≥ 1.0) and no core detection in earlier studies. Our deep multifrequency VLA, pc-scale Very Long Baseline Array, and enhanced Multi Element Remotely Linked Interferometer Network (e-MERLIN) observations allowed us to locate the core component in 10 objects. In three CSS sources, there is no clear evidence of present-time active regions, suggesting that they are likely in a remnant phase. Among sources with core detection, we find three objects that have no clear active regions (hotspots) at the edges of the radio structure, suggesting that the radio emission may have just restarted. Our results support a power-law distribution of the source ages, although the poor statistics prevents us from setting solid constraints on the percentage of remnants and restarted sources in subpopulations of radio sources.

79 ASTRONOMY AND ASTROPHYSICS↗

A Novel Machine Learning Algorithm for Cloud Detection Using AERI Measurement Data

Infrared hyperspectral remote sensing has been widely used in the field of meteorology. Many scientists have carried out research on inversion methods of meteorological elements such as thermodynamic profile, boundary layer height, cloud base height, etc. In this study, a method based on machine learning for cloud detection using ground-based infrared hyperspectral radiation data is proposed. The features of outliers, the cloudy and cloud-free data of Atmospheric Emitted Radiance Interferometer (AERI) radiation are extracted. The “reference values” of cloudy and cloud-free are determined based on the observation data of Vaisala CL31 ceilometer within the time range of 8 min before the corresponding time of AERI. A support vector machine (SVM) algorithm is used for training. The dataset comes from the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site and North Slope Alaska (NSA) site from 2015 to 2017, and the ARM West Antarctic Radiation Experiment (AWARE) site in 2016 is also analyzed. The instruments used in this paper include AERI, ceilometer, etc. The experimental results reveal that the agreement of cloud detection results between the proposed algorithm and ceilometer is about 93% at each site. However, for high clouds or optically thin clouds, the agreement will decrease.

47 OTHER INSTRUMENTATION↗

Graviton detection and the quantization of gravity

We revisit a question asked by Dyson: “Is a graviton detectable?” We demonstrate that in both Dyson’s original sense and in a more modern measurement-theoretic sense, it is possible to construct a detector sensitive to single gravitons, and in fact a variety of existing and near-term gravitational wave detectors can achieve this. However, while such a signal would be consistent with the quantization of the gravitational field, we draw on results from quantum optics to show how the same signal could just as well be explained via classical gravitational waves. We outline the kind of measurements that would be needed to demonstrate quantization of gravitational radiation and explain why these are substantially more difficult than simply counting graviton clicks or observing gravitational noise in an interferometer, and likely impossible to perform in practice. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗

Spinning metasurface stack for spectro-polarimetric thermal imaging

Spectro-polarimetric imaging in the long-wave infrared (LWIR) region plays a crucial role in applications from night vision and machine perception to trace gas sensing and thermography. However, the current generation of spectro-polarimetric LWIR imagers suffers from limitations in size, spectral resolution, and field of view (FOV). While meta-optics-based strategies for spectro-polarimetric imaging have been explored in the visible spectrum, their potential for thermal imaging remains largely unexplored. In this work, we introduce an approach for spectro-polarimetric decomposition by combining large-area stacked meta-optical devices with advanced computational imaging algorithms. The co-design of a stack of spinning dispersive metasurfaces along with compressive sensing and dictionary learning algorithms allows simultaneous spectral and polarimetric resolution without the need for bulky filter wheels or interferometers. Our spinning-metasurface-based spectro-polarimetric stack is compact (<10×10×10cm) and robust, and it offers a wide field of view (20.5°). We show that the spectral resolving power of our system substantially enhances performance in machine learning tasks such as material classification, a challenge for conventional panchromatic thermal cameras. Our approach represents a significant advance in the field of thermal imaging for a wide range of applications including heat-assisted detection and ranging (HADAR).

Optics↗

Matter-wave interference of a native polypeptide

The de Broglie wave nature of matter is a paradigmatic example of quantum physics and it has been exploited in precision measurements of forces and fundamental constants. However, matter-wave interferometry has remained an outstanding challenge for natural polypeptides, building blocks of life, which are fragile and difficult to handle. Here, we demonstrate the wave nature of gramicidin, a natural antibiotic composed of 15 amino acids. Its center of mass is delocalized over more than 20 times the molecular size in our timedomain Talbot-Lau interferometer. We compare the observed interference fringes with a model that includes both a rigorous treatment of the peptide’s quantum wave nature as well as a quantum chemical assessment of its optical properties to distinguish our result from classical predictions. The realization of quantum optics with this prototypical biomolecule paves the way for quantum-assisted measurements on a large class of biologically relevant molecules.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum optical classifier with superexponential speedup

Abstract Classification is a central task in deep learning algorithms. Usually, images are first captured and then processed by a sequence of operations, of which the artificial neuron represents one of the fundamental units. This paradigm requires significant resources that scale (at least) linearly in the image resolution, both in terms of photons and computational operations. Here, we present a quantum optical pattern recognition method for binary classification tasks. It classifies objects without reconstructing their images, using the rate of two-photon coincidences at the output of a Hong-Ou-Mandel interferometer, where both the input and the classifier parameters are encoded into single-photon states. Our method exhibits the behaviour of a classical neuron of unit depth. Once trained, it shows a constant $${{\mathcal{O}}}(1)$$ O ( 1 ) complexity in the number of computational operations and photons required by a single classification. This is a superexponential advantage over a classical artificial neuron.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗