Long Term Per-Component Power and Thermal Measurements of the OLCF Summit System

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide a dataset that records the long-term power and thermal behavior of the 200PF pre-exascale supercomputer at the Oak Ridge Leadership Computing Facility (OLCF), Summit. This system is an IBM AC922 based system that has 9,252 IBM Power9 CPUs and 27,756 Nvidia V100 GPUs and can consume up to 13MW power at peak. Heat removal is performed using medium temperature direct liquid cooling and rear-door heat exchanger based secondary cooling loop. Originally extracted from a high-resolution (1Hz) per-component (GPUs, CPUs) measurements from the system, we primarily provide a dataset that has 10-second and 1-minute mean power and thermal measurements selected from five month-long segments over the course of 2020 (January and August), 2021 (February and August), and 2022 (January). For convenience, we also provide various sub datasets randomly sampled from the time and space (hosts) of the cluster. Further details and example code for analysis can be found in the following GitHub repository: https://github.com/at-aaims/summit_power_and_thermal_data

97 MATHEMATICS AND COMPUTING↗

Experimental Testing of Particle Erosion and Attrition in CSP Systems

In CSP systems using solid particles for heat transfer, erosion from the falling particles can damage the system components upon impact, and from sliding against the component walls. Furthermore, the resulting attrition of particles can change the thermal performance due to alterations in particle morphology. The research on these issues has been limited to industrial applications, and don’t necessarily coincide with the operating conditions in CSP systems. In this work, we investigated the durability of the particles selected as the heat transfer media, as well as special substrate materials that are of interest as lining materials to the particle storage tanks and hoppers. Three different erosion phenomena were studied: impact, abrasion, and attrition erosion. The low-temperature experiments revealed negligible losses from attrition and abrasion erosion. Although the substrates indicated visible surface damage from impact erosion, the actual material mass loss was small even after a throughput of 500kg of particles 63 days of 1MW CSP plant operation assuming 14 hours per day of operation. Erosion is typically classified as impact, abrasion, or attrition erosion. For example, the CSP systems utilizing solid particles as heat transfer media will likely experience impact erosion on the receiver hopper and heat exchanger walls as the solid particles fall from the reservoir. Additionally, there will be sliding erosion along the receiver walls as particles move through the hopper, and lastly, there will also be attrition erosion as the particles rub against each other. The extent of erosion depends on many factors including but not limited to particle shape and size, material hardness/brittleness and ductility, and particle impact speed and angle. Mechanistic erosion equations that are available in the literature are mostly derived from data pertaining to specific experiments and therefore can’t be applied to all applications without suitable adjustments. Survey of the literature relating to particle-based receivers revealed that the most prevalent approach has been to choose low velocities to limit erosion, but to our knowledge, little effort has been put in to fully characterize erosion at the expected operating conditions. A relatively recent work investigated the erosion of wire mesh proposed for use in a particle receiver, where the results actually showed an increase in mass as oxidation occurred on the mesh surface but the work did not investigate the particle attrition rate, and the erosion rate of a solid substrate. The end goal of this work is to develop a comprehensive particle and substrate durability model that will allow a comprehensive understanding of particle-based CSP operating conditions on component durability.

14 SOLAR ENERGY↗

Film Cooling Performance Predictions For Air And Supercritical CO 2

The current study explores the possibility of cooling the vanes and blades of a direct-fired sCO 2 turbine using film cooling geometries. The operating conditions of a direct-fired sCO 2 cycle and thermophysical properties of the fluid at those conditions can alter the flow field characteristics of the coolant jet and its mixing with the mainstream. Very little information is present in the literature regarding the performance of film cooling geometries employing a supercritical fluid. The objective of this study is to estimate the resulting film cooling effectiveness while also capturing the effects of the crossflow-to-mainstream velocity ratio on the coolant jet. A computational fluid dynamic model is used to study the coolant jet exiting a cylindrical hole located on a flat plate, with the coolant fed by an internal channel. Steady-state RANS equations were solved along with the SST kω model to provide the turbulence closure. The operating conditions for the direct-fired sCO 2 turbine are obtained using an in-house Cooled Turbine Model. Numerical predictions revealed that the crossflow effects and jet lift-off were more pronounced in the case of sCO 2 when compared to air. Spatial distribution of flow field and cooling effectiveness will be presented at different operating conditions. Recommendations for future studies will be given wherever applicable.

42 ENGINEERING↗

Film Cooling Performance Prediction for Air and Supercritical CO 2

The current study explores the possibility of cooling the vanes and blades of a direct-fired sCO 2 turbine using film cooling. The operating conditions of a direct-fired sCO 2 cycle and thermophysical properties of the fluid at those conditions can alter the flow field characteristics of the coolant jet and its mixing with the mainstream. Very little information is present in the literature regarding the performance of film cooling geometries employing supercritical CO 2 . The objective of this study is to estimate the resulting film cooling effectiveness while also capturing the effects of the crossflow-to-mainstream velocity ratio on the coolant jet. Herein, a computational fluid dynamic model is used to study the coolant jet exiting a cylindrical hole located on a flat plate, with the coolant fed by an internal channel. Steady-state Reynolds-averaged Navier–Stokes equations were solved along with the (shear-stress transport) SST k–ω model to provide the turbulence closure. The operating conditions for the direct-fired sCO 2 turbine are obtained using an in-house Cooled Turbine Model. Numerical predictions revealed that the crossflow effects and jet lift-off were more pronounced in the case of sCO 2 when compared to air. Spatial distribution of flow field and cooling effectiveness are presented at different operating conditions.

30 DIRECT ENERGY CONVERSION↗

Coatings for CSP Lifetime

The feasibility and performance of tower-technology-based concentrated solar power (CSP) is highly dependent on the efficiency of the energy transformation from sun to heat at the receiver. The higher the solar absorptivity of the receiver coating, the higher the efficiency of the plant as a whole. BrightSource Energy (BSE) has developed a series of High-Performance Coating (HPC) systems in order to achieve high absorptivity over the plant lifetime (25-35 years). This requires stable coatings that are easily applicable on the large receiver surface and will maintain their optical properties under intense solar flux and thousands of heating and cooling cycles in desert conditions. Different coating formulations are required according to the differing plant conditions: receiver materials, operating conditions (temperatures, daily cycles, etc.), and environmental conditions. BSE also developed a coating for the next generation of CSP receivers, such as those being under DOE’s CSP Gen3 program, which will be operated with high temperature heat transfer fluids at temperatures of up to 800°C, which is significantly hotter than the operating temperature of current systems. Once the coating is formulated, the next challenge is evaluating its lifetime properties. BSE has found several independent failure modes that impact HPC absorptivity degradation: • Decrease in HPC optical properties due to oxidation in the receiver tubes surface below the HPC; • HPC film deterioration due to cycling of temperatures and humidity due to daily operation startup and shutdown as well as changing ambient conditions; • Mechanical degradation due to erosion by sand and wind. Existing test methods examine various aspects independently, but do not provide a combined accelerated lifetime result. Creating such a combined test suite, with a way to interpret the results to predict the coating’s projected lifetime, was the ultimate goal of this project. The project was divided into three major workstreams: lab testing (individual failure mode tests and combined failure mode tests); developing a theoretical model for aging; and validation of the test apparatus via on-sun testing in near real-world conditions at CIEMAT-PSA. Developing a test apparatus that accurately controlled the temperature while also introducing the desired solar flux proved more challenging than expected. While in the end we did succeed in creating a test apparatus that can control temperature, solar flux, and humidity, the results did not appear to accelerate the lifetime of the samples as desired. We suspect that to properly accelerate the samples we must also subject the samples to increased amounts of oxygen. Similarly, while we successfully created a combined model that is publicly available, we were unable to validate it sufficiently to feel comfortable recommending it as a general guideline.

14 SOLAR ENERGY↗

Ultrasonic Testing of Mechanical Changes in a Water-Filled Pipe with Multi-Mode and Broadband Signals and Two-Level Compensation

Ultrasonic testing (UT) has been widely used for the Nondestructive Evaluation (NDE) of pipes due to its many favorable characteristics. However, one of the main challenges in the general use of UT for real-world pipelines is the sensitivity of this method to environmental and operational condition changes. This paper proposes a new UT method with enhanced compensation for environmental effects and operational condition changes. In particular, the effectiveness of the new method is tested in the presence of temperature variations, and changes in water flow rate inside a stainless-steel pipe. The proposed UT method uses multi-mode and broadband guided ultrasonic waves in the pipe walls, excited and received by single-element ultrasonic sensors that are spatially separated, forming a measurement zone between any pair of such transmit and receive sensors. Amplitude changes, time shifts, and frequency content variations in the ultrasonic signal due to temperature changes and water flow are evaluated and compensated for reliable UT of mechanical changes in the pipe. It is observed that spurious effects of water flow on ultrasonic response, if not properly compensated, can dominate over effects due to actual mechanical changes, but such liquid-boundary effects can be compensated effectively by the proposed time- and frequency-filtering method.

47 OTHER INSTRUMENTATION↗

Sensitivity Analysis and Effective Parametrization of PEM Fuel Cell Models

The cost of proton-exchange-membrane fuel cells (PEMFCs) remains a major hurdle in large-scale commercialization of this technology. To improve their performance and reduce cost, novel materials and electrode designs are continuously envisioned, e.g., non-PGM catalyst layers, ultra-thin Pt/Pt-Ni based catalyst layers, structured ionomer arrays or NSTF catalyst layers.1 Understanding the impact of these improvement strategies can be extremely time and cost intensive due to complex physical phenomena and large design space. We have previously developed a PEMFC modeling framework2 which has been a time and cost effective tool for understanding and optimizing the complex multi-physics phenomena within PEMFCs; however, several of the cell parameters used in the modeling have large spread in measured data.3 Furthermore, several transport parameters such as water adsorption kinetics have not been accurately measured and the approximations are spread over several orders of magnitude. These uncertainties cause problems in ascertaining accuracy of the modeling approach and they reduce the predictive power of the numerical models. The aim of this work is to identify the sensitivity of PEFC numerical model outputs to various input parameters. The previously in-house developed MEA modeling framework2 is used for PEMFC modeling. The sensitivity of the model outputs with respect to inputs parameters is obtained by analyzing the condition numbers for different output-input pairs at varying operating conditions. An example of the sensitivity analysis is shown in Figure 1. The condition numbers are obtained for the entire possible range of input parameters at varying operating conditions to identify the most crucial parameters of the PEMFC model. Based on our preliminary analysis, parameters related to kinetics (exchange current density and ECSA) and heat/water management in electrodes and ionomer (ionomer fraction, thermal conductivity) are most crucial. One of the major goals of this work is to identify the most crucial set of parameters towards which the model shows maximum sensitivity. This will guide future experimentalists to measure these properties with higher accuracy. Furthermore, the sensitivity analysis will also enable us to optimize the PEMFC performance by selectively targeting the most sensitive parameters and thereby making the largest impact. Acknowledgements The work is funded under the Fuel Cell Performance and Durability Consortium (FC-PAD), by the Fuel Cell Technologies Office (FCTO), Office of Energy Efficiency and Renewable Energy (EERE), of the U.S. Department of Energy under contract number DE-AC02-05CH11231. The authors would like to thank Nathan Craig at Robert Bosch LLC for his valuable input in designing the sensitivity analysis. The authors would also like to thank Giovanna Bucci and Matthias Hanauer at Robert Bosch for their valuable inputs and discussion. References P. K. Sinha, W. Gu, A. Kongkanand and E. Thompson, J. Electrochem. Soc., 158, B831 (2011). L. M. Pant, M. R. Gerhardt, N. Macauley, R. Mukundan, R. L. Borup and A. Z. Weber, Electrochim. Acta, 326, 134963 (2019). R. Vetter and J. O. Schumacher, ArXiv181110091 Phys. (2018). Figure 1

Pant, Lalit↗

Application of Sequential Design of Experiments (SDoE) to Large Pilot-Scale Solvent-Based CO2 Capture Process at Technology Centre Mongstad (TCM)

The United States Department of Energy’s Carbon Capture Simulation for Industry Impact (CCSI2) program has developed a framework for sequential design of experiments (SDoE) that aims to maximize knowledge gained from budget- and schedule-limited pilot scale testing. SDoE was applied to the planning and execution of campaigns for testing CO2 capture systems at pilot-scale in order to optimally allocate resources available for the testing. In this methodology, a stochastic process model is developed by quantifying the parametric uncertainty in submodels of interest; for a solvent-based CO2 capture system, these may include physical properties and equipment performance submodels (e.g., mass transfer, interfacial area). This uncertainty is propagated through the full process model, over variable operating conditions, for estimating the resulting uncertainty in key model outputs (e.g., percentage of CO2 capture, solvent regeneration energy requirement). In developing a data collection plan, the predicted output uncertainty is incorporated into an algorithm that seeks simultaneously to select process operating conditions for which the predicted uncertainty is relatively high and to ensure that the entire space of operation is well represented. This test plan is then used to guide operation of the pilot plant at varying steady-state conditions, with resulting process data incorporated into the existing model using Bayesian inference to refine parameter distributions. The updated stochastic model, with reduced parametric uncertainty from data collected, is then used to guide additional data collection, thus the sequential nature of the experimental design. The SDoE process was implemented at the pilot test unit (12 MWe in scale) at Norway’s Technology Centre Mongstad (TCM) in a summer 2018 test campaign with aqueous monoethanolamine (MEA). During the test campaign, the varied operating conditions included the flowrates of circulated solvent, flue gas, and reboiler steam and the CO2 concentration in the flue gas. The process data were used to update probability distributions of mass transfer and interfacial area parameters of a stochastic process model developed by the CCSI2 team. Two iterations of the SDoE process were executed, resulting in the uncertainty in model predicted CO2 capture percentage decreasing by an average of 58.0 ± 4.7% over the full input space of interest. This work demonstrates the potential of the SDoE process for model refinement through reduction in process model parametric uncertainty, and ultimately risk in scale-up, in CO2 capture technology performance.

carbon capture↗

Development of Accelerated Steady-state Test Capsule Experiments to Replicate EBR-II Fuel Behavior Using BISON Fuel Performance Analysis

Here in this work, BISON fuel performance calculations were performed to predict the fuel behavior of accelerated burnup U-Pu-Zr fuel, with temperature operation conditions of the fuel and the cladding mirroring conditions within EBR-II fuel pins. The temperature operating conditions within the FAST accelerated burnup rods were aimed at replicating EBR-II X447/X447A fuel surface and inner cladding surface temperatures. Due to the FAST capsule design, these temperatures can be replicated with fission rate densities being significantly increased. fuel performance modeling has not been assessed for novel experiments such as accelerated burnup utilizing the FAST capsule within ATR. This is an important step in understanding accelerated irradiation methods as many performance models are empirical models conforming to the results of PIE but do not always include physical models that would represent the changes in irradiation tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Decoupling Failure Pathways in Li-O 2 Cells Operated Under Lean Electrolyte Conditions

The operation of lithium-oxygen (Li-O 2 ) batteries under lean electrolyte conditions offers higher energy density but leads to rapid degradation and short cycle life. Although cathode passivation and electrolyte decomposition occur in all regimes, we show that under lean electrolyte conditions, failure is primarily driven by progressive electrolyte consumption at the lithium/solid electrolyte interphase (SEI), rather than by irreversible cathode passivation. Poor wetting of the lithium surface results in heterogeneous SEI growth and high local current densities, which accelerate electrolyte loss and cell failure. Strategies aimed at improving interfacial stability, including optimized wetting and SEI forming additives, significantly extend cycle life without compromising energy density. Our results establish anode-electrolyte interactions as the dominant degradation mechanism under lean electrolyte conditions, and emphasize the need to engineer a stable Li/SEI interface for long-lasting Li-O 2 batteries.

Córdoba, Daniel [Argonne National Laboratory (ANL)↗

Using operando techniques to understand and design high performance and stable alkaline membrane fuel cells

There is a need to understand the water dynamics of alkaline membrane fuel cells under various operating conditions to create electrodes that enable high performance and stable, long-term operation. Here we show, via operando neutron imaging and operando micro X-ray computed tomography, visualizations of the spatial and temporal distribution of liquid water in operating cells. We provide direct evidence for liquid water accumulation at the anode, which causes severe ionomer swelling and performance loss, as well as cell dryout from undesirably low water content in the cathode. We observe that the operating conditions leading to the highest power density during polarization are not generally the conditions that allow for long-term stable operation. This observation leads to new catalyst layer designs and gas diffusion layers. This study reports alkaline membrane fuel cells that can be operated continuously for over 1000 h at 600 mA cm -2 with voltage decay rate of only 32-μV h -1 – the best-reported durability to date.

25 ENERGY STORAGE↗

Preliminary Design of Reactor Cavity Cooling System for a Horizontal Compact HTGR

The Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed MIGHTR in 3 years and support its commercialization as a safe and low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. This report documents the preliminary design study of the RCCS for the HC-HTGR. It includes the establishment of the design requirements, a high-level design study by initial scoping calculations, and preliminary performance calculations of the HC-HTGR RCCS design. Design requirements for the HC-HTGR RCCS have been established to guide preliminary design activities and scoping performance calculations. Initial scoping calculations including estimation of the water inventory, estimation of HVAC thermal capability, and a parametric study on loop dimensions by standalone RCCS analysis. Based on scoping calculation results, a set of baseline dimensions of the HC-HTGR RCCS was derived. A water panel modeling approach was investigated to explore various potential design options for the water panel under consideration for the HC-HTGR RCCS using RELAP5-3D. A test case study was performed to assess the prediction capability of two modeling approaches. The results were compared with CFD simulations conducted in constant RPV temperature and heat flux boundary conditions. It confirms the capability of the RELAP5-3D modeling approach to include all important heat transfer mechanisms expected in the HC-HTGR RCCS operation conditions. Then, a reference RELAP5-3D model for the 1/8 th of a compartment of the preliminary design of the HC-HTGR RCCS was developed. A preliminary performance analysis was conducted to evaluate single-phase natural circulation performance with different top tank temperature values and panel conduction performance in various operation conditions. From single-phase natural circulation performance analysis, the system operation mode was investigated in normal operating and limiting design conditions. It showed operation mode in a subcooled state with a proper top tank water cooling system. Parasitic heat loss by both internal air flow and RCCS was estimated, showing it satisfies maintaining below target maximum heat loss of the HC-HTGR RCCS. From the panel conduction performance analysis, two candidate materials for the riser tube such as carbon steel and stainless steel were compared in the thermal performance of HC-HTGR RCCS. From a single water panel test compared with CFD simulation results, it was confirmed that the current capability of the RELAP5-3D modeling approach for the water panel predicts the thermal conduction of two different materials of the water panel. Then, system-level thermal performance analysis was performed for 1/8 th of the compartment of the preliminary HC-HTGR RCCS design. It was first observed that the current preliminary HC-HTGR RCCS design had minimal impact on the overall thermal performance of the water panel by changing pipe material from carbon steel to stainless steel. From Argonne’s effort on the ongoing water-based NSTF testing program, several considerations other than the thermal performance point of view were addressed to be considered in selecting pipe materials.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Crossflow membrane filtration system for operando fouling characterization using transmission x-ray scattering

Membrane-based separations are widely used for wastewater treatment due to their low cost and efficiency. However, membrane fouling, which is the unwanted deposition or attachment of contaminants on membrane surfaces and/or within membrane pores, remains a major challenge as it increases the mass transfer resistance and reduces membrane productivity. Membrane fouling is typically probed by macroscopic performance metrics, such as flux decline, and ex situ characterization. However, this does not capture the membrane and fouling layer evolution under operating conditions, potentially masking important mechanisms and nonequilibrium pathways that impact fouling. Here, we present a remotely controlled crossflow membrane system and a custom membrane cell for operando fouling characterization using transmission small/wide angle x-ray scattering (SAXS/WAXS). This approach allows direct observation of the nanoscale changes occurring at the membrane surface during pressurized water treatment processes, enabling a new way to understand the connections between dynamic fouling behaviors and membrane performance. Nanoparticle fouling of porous membranes during ultrafiltration was investigated using operando SAXS, and mineral scaling of reverse osmosis membranes was investigated using operando WAXS. Furthermore, this system allows for tracking membrane fouling in real time and under realistic conditions, providing fundamental physical insights into how water chemistry and operating conditions affect macroscopic membrane performance. Moreover, this system opens the door for future in situ and operando studies, and it serves as a testbed for evaluating novel materials/processes for membrane-based separations.

36 MATERIALS SCIENCE↗

Examination of Legacy Metallic Fuel Pins (U-10Zr) Tested in FFTF

The MFF series of metallic fuel (U-10wt%Zr) tests performed in the Fast Fuel Test Facility (FFTF) were the beginning tests to qualify the fuel as a driver fuel for FFTF. They all performed very well, to relatively high burnup and with no pin breaches. Tests MFF-3 and MFF-5 were chosen to be destructively examined because they were run at high peak cladding temperatures, 643 and 649°C respectively, and to modest to high burnup (138 and 101 MWd/kgM respectively). They were the only sodium fast reactor (SFR) metallic tests, with long (91.4 cm) fuel columns and clad in HT9, to be operated at these high temperatures. Extensive operating condition reconstruction was performed to accompany the examination, providing detailed operating conditions axially along the pins. In addition, detailed ORIGEN calculations provided fuel burnup along the pin length. These calculations and detailed cross-section metallography allowed a PhD dissertation to be performed where the fuel/cladding chemical interaction (FCCI) was modeled using Fickian and Soret Effect driven diffusion of rare earth fission products to the cladding surface and interact with the cladding. The examination of the MFF-3 and MFF-5 pins included neutron radiography, axial profilometry including pin bow and length measurements, precision gamma scanning, plenum gas puncturing to measure fission gas release, detailed chemical/isotopic analyses of fuel samples to confirm burnup calculations, and metallography of pin cross-sections, including micro-hardness measurements of fuel and cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

First-principles Modeling and Design of Solid-State Interfaces for the Protection and Use of Lithium Metal Anodes

Li-ion batteries are one of the most advanced energy storage technologies in use today. Li-ion batteries are used in a multitude of applications ranging from consumer electronics, medical devices, sensors and grid storage. However, improving the capacity and energy density delivered by current Li-ion technology requires advanced materials research into novel chemical systems. In this project we have focused particularly in the use of solid-state electrolytes with lithium metal electrodes. Research into all solid-state batteries (ASSB) with Li metal electrodes has significantly expanded in recent years, however most studies reported experimental findings, which left substantial room for theoretical and modeling work as a tool to understand and determine design principles allowing reliable and safe use of ASSBs with Li metal. Among the remaining obstacles preventing reliable use of ASSBs with a Li metal electrode, the stability of the interface between the solid electrolyte and Li metal, and the propagation/dendrite formation of Li metal and resulting mechanical degradation of the electrolyte are key phenomenon that are yet to be fully understood. In the current project we have addressed these two coupled phenomena using first principles calculations and mesoscale continuum modeling. We have obtained chemical and electrochemical stability windows for several solid electrolyte materials. Additionally, from mathematical and numerical modeling of Li protrusion and dendrite initiation during plating and stripping we have determined design criteria in terms of chemical, electrochemical, and mechanical properties and operating conditions for which stable deposition can occur. We also considered the effects of mixed electronic-ionic conduction in solid electrolytes, which has more recently been suggested as another important mechanism involved in ASSB failure. Throughout our work we have successfully addressed important questions necessary for the use of ASSB’s. We have determined guiding principles for materials properties and operating conditions necessary to operate ASSB’s. And have proposed novel solid electrolyte materials with predicted chemical stability an ionic conductivity. Although this represents significant progress in our understanding, open questions remain in order to fully develop reliable and safely operate ASSBs with Li metal. Future work, building on this project will require further experimental, theoretical and simulation efforts to address remaining questions.

25 ENERGY STORAGE↗

Architecture-Based Control of Temperature Gradient-Driven Water Transport in Polymer Electrolyte Fuel Cells

Temperature gradients can move water within the porous media of a polymer electrolyte fuel cell through phase-change-induced (PCI) flow. It is critical to understand PCI flow so that control and distribution of water within a fuel cell can be accomplished. This work investigates the role of architecture, specifically anode land width, on overall cell water content and distribution in the through-plane direction. A specially-designed 4.8 cm 2 fuel cell with precise thermal boundary conditions was imaged with neutrons using two different anode flow field configurations. A new, non-dimensional thermal transport number was developed which quantifies the relative influence of PCI flow on cell water transport. It was found that anode lands larger than the cathode lands cause large thermal gradients that instigate net water flux from the cathode to the anode. An asymmetric configuration with larger anode lands was found to have large changes in water content that were strongly sensitive to cell operating conditions. The thermal transport number developed here enables deduction of the net flux condition based on operating conditions and architecture. This approach enables design of high-performance systems with balanced water management.

25 ENERGY STORAGE↗

Insights into mixing of non-isothermal multi-polymer melts for complex plastics recycling

Catalytic recycling or upcycling of plastics is often limited not by catalyst performance, but by transport, arising from highly viscous, non-Newtonian polymer melts. In this work, we develop a reactor-scale framework that integrates rheological measurements, constitutive modeling, computational fluid dynamics (CFD), and experiments to quantify mixing, heat transfer, and dispersion in surrogate hydrocarbon melts representing mixed plastics systems. Temperature- and shear rate-dependent viscosity of low-density polyethylene (LDPE) and high-density polyethylene (HDPE) is measured to create two surrogate polymers (PLD and PHD) that capture the dominant shear-thinning flow behavior while neglecting strong elastic effects, enabling tractable simulation of non-isothermal, polymer-melt mixing using a Carreau-Arrhenius generalized Newtonian framework. Three-dimensional CFD simulations are employed to evaluate impeller performance in PLD using mixing time, cavern volume, thermal uniformity, and interfacial area for regimes in which viscoelastic effects are not dominant. We show that magnetic stir bars commonly used in lab-scale studies produce large thermal gradients (~60 °C) and poor mixing, even under idealized power delivery and polymer flow conditions. In contrast, close-clearance anchor impellers achieve near-isothermal operation, reduce mixing times by up to 5×, and provide >90% active circulation volume. We further demonstrate that, at low pseudo-Deborah number (De*), motor power requirements can be predicted directly from shear rate-dependent rheology using the Carreau-Arrhenius framework, enabling rational selection of operating conditions. Extension to surrogate immiscible multi-polymer systems based on PLD and PHD shows that interfacial area is highly sensitive to operating conditions and impeller design, with coaxial anchor-turbine configurations enhancing dispersion by up to 4 × .

Close-clearance impellers↗

Hybrid electric vehicle and method of operating engine of the same

A hybrid electric vehicle (HEV) for multiple operation modes includes: a gasoline diffusion flame (GDF) combustion engine configured to perform gasoline diffusion flame combustion; a motor-generator operatively connected to the GDF combustion engine and configured to selectively drive the HEV with electric power of a battery or generate electric power to charge the battery; and a multi-mode controller including a processor and configured to receive operating conditions of the GDF combustion engine and the motor-generator and define a plurality of mode operating regions based on the received operating conditions. In particular, the plurality of mode operating regions includes: an electric vehicle (EV) only mode operating region, a GDF mode operating region where the GDF combustion engine operates and drives the HEV while the motor-generator stops, and a GDF+EV mode operating region where the motor-generator assists the operation of the GDF combustion engine to drive the HEV.

Bourcier, Mark↗