Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “occupancy detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Detection of Airborne Influenza A and SARS-CoV-2 Virus Shedding following Ocular Inoculation of Ferrets

Despite reports of confirmed human infection following ocular exposure with both influenza A virus (IAV) and SARS-CoV-2, the dynamics of virus spread throughout oculonasal tissues and the relative capacity of virus transmission following ocular inoculation remain poorly understood. Furthermore, the impact of exposure route on subsequent release of airborne viral particles into the air has not been examined previously. To assess this, ferrets were inoculated by the ocular route with A(H1N1)pdm09 and A(H7N9) IAVs and two SARS-CoV-2 (early pandemic Washington/1 and Delta variant) viruses. Virus replication was assessed in both respiratory and ocular specimens, and transmission was evaluated in direct contact or respiratory droplet settings. Viral RNA in aerosols shed by inoculated ferrets was quantified with a two-stage cyclone aerosol sampler (National Institute for Occupational Safety and Health [NIOSH]). All IAV and SARS-CoV-2 viruses mounted a productive and transmissible infection in ferrets following ocular inoculation, with peak viral titers and release of virus-laden aerosols from ferrets indistinguishable from those from ferrets inoculated by previously characterized intranasal inoculation methods. Viral RNA was detected in ferret conjunctival washes from all viruses examined, though infectious virus in this specimen was recovered only following IAV inoculation. Low-dose ocular-only aerosol exposure or inhalation aerosol exposure of ferrets to IAV similarly led to productive infection of ferrets and shedding of aerosolized virus. Viral evolution during infection was comparable between all inoculation routes examined. Furthermore, these data support that both IAV and SARS-CoV-2 can establish a high-titer mammalian infection following ocular exposure that is associated with rapid detection of virus-laden aerosols shed by inoculated animals.

60 APPLIED LIFE SCIENCES↗

Automatic Facial Expression Recognition and Operator Functional State

The prevalence of human error in safety-critical occupations remains a major challenge to mission success despite increasing automation in control processes. Although various methods have been proposed to prevent incidences of human error, none of these have been developed to employ the detection and regulation of Operator Functional State (OFS), or the optimal condition of the operator while performing a task, in work environments due to drawbacks such as obtrusiveness and impracticality. A video-based system with the ability to infer an individual's emotional state from facial feature patterning mitigates some of the problems associated with other methods of detecting OFS, like obtrusiveness and impracticality in integration with the mission environment. This paper explores the utility of facial expression recognition as a technology for inferring OFS by first expounding on the intricacies of OFS and the scientific background behind emotion and its relationship with an individual's state. Then, descriptions of the feedback loop and the emotion protocols proposed for the facial recognition program are explained. A basic version of the facial expression recognition program uses Haar classifiers and OpenCV libraries to automatically locate key facial landmarks during a live video stream. Various methods of creating facial expression recognition software are reviewed to guide future extensions of the program. The paper concludes with an examination of the steps necessary in the research of emotion and recommendations for the creation of an automatic facial expression recognition program for use in real-time, safety-critical missions.

Blanson, Nina↗

Automatic Facial Expression Recognition and Operator Functional State

The prevalence of human error in safety-critical occupations remains a major challenge to mission success despite increasing automation in control processes. Although various methods have been proposed to prevent incidences of human error, none of these have been developed to employ the detection and regulation of Operator Functional State (OFS), or the optimal condition of the operator while performing a task, in work environments due to drawbacks such as obtrusiveness and impracticality. A video-based system with the ability to infer an individual's emotional state from facial feature patterning mitigates some of the problems associated with other methods of detecting OFS, like obtrusiveness and impracticality in integration with the mission environment. This paper explores the utility of facial expression recognition as a technology for inferring OFS by first expounding on the intricacies of OFS and the scientific background behind emotion and its relationship with an individual's state. Then, descriptions of the feedback loop and the emotion protocols proposed for the facial recognition program are explained. A basic version of the facial expression recognition program uses Haar classifiers and OpenCV libraries to automatically locate key facial landmarks during a live video stream. Various methods of creating facial expression recognition software are reviewed to guide future extensions of the program. The paper concludes with an examination of the steps necessary in the research of emotion and recommendations for the creation of an automatic facial expression recognition program for use in real-time, safety-critical missions

Blanson, Nina↗

Pressure cells for in situ neutron total scattering: time and real-space resolution during deuterium absorption

In situ gas-loading sample holders for two-dimensionally arranged detectors in time-of-flight neutron total scattering experiments have been developed to investigate atomic arrangements during deuterium absorption using time and real-space resolution. A single-crystal sapphire container was developed that allows conditions of 473 K and 10 MPa hydrogen gas pressure. High-resolution transient measurements detected deuterium absorption by palladium that proceeded within a few seconds. A double-layered container with thick- and thin-walled vanadium allowed conditions of 423 K and 10 MPa hydrogen gas pressure. The deuterium occupation sites of a lanthanum–nickel–aluminium alloy are discussed in detail on the basis of real-space high-resolution data obtained from in situ neutron scattering measurements and reverse Monte Carlo structural modeling.

08 HYDROGEN↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

EPA/NASA/USAF Depainting Effort Concludes

The final report contains strip rate data from all of the methods, lessons learned during processing, metallurgical evaluations of the panels, and summaries of corrosion and hydrogen embrittlement studies. Any changes in surface roughness, fatigue and tensile properties, and crack detectability are noted in the report. No process was singled out above the others, as companies should consider equipment and operational costs when complying with the Aerospace NESHAP (National Emission Standards for Hazardous Air Pollutants) and new OSHA (Occupational Safety and Health Administration) regulations.

Finckenor, Miria M.↗

Surveillance in a Telemedicine Setting: Application of Epidemiologic Methods at NASA Johnson Space Center Adriana

Space medicine presents unique challenges and opportunities for epidemiologists, such as the use of telemedicine during spaceflight. Medical capabilities aboard the International Space Station (ISS) are limited due to severe restrictions on power, volume, and mass. Consequently, inflight health information is based heavily on crewmember (CM) self-report of signs and symptoms, rather than formal diagnoses. While CM's are in flight, the primary source of crew health information is verbal communication between physicians and crewmembers. In 2010 NASA implemented the Lifetime Surveillance of Astronaut Health, an occupational surveillance program for the U.S. Astronaut corps. This has shifted the epidemiological paradigm from tracking diagnoses based on traditional terrestrial clinical practice to one that incorporates symptomatology and may gain a more population-based understanding of early detection of disease process.

Babiak-Vazquez, Adriana↗

Passive, Direct-Read Monitoring System for Selective Detection and Quantification of Hydrogen Chloride

Monitoring the exposure of an employee to hydrogen chloride or hydrochloric acid in the presence of other acids has been a challenge to the industrial hygiene community. The capability of a device to differentiate the levels of acid vapors would allow for more accurate determinations of exposure and therefore improved occupational health. In this work, a selective direct-read colorimetric badge system was validated for Short Term Exposure Limit (STEL) monitoring of hydrogen chloride. The passive colorimetric badge system consists of a direct reading badge and a color scale. The badge has a coated indicator layer with a diffusive resistance in the shape of an exclamation mark. An exclamation mark will appear if hydrogen chloride is present in the atmosphere at concentrations at or above 2.0 ppm. By using the color scale, the intensity of the color formed on the badge can be further quantified up to 25 ppm. The system was validated according to a protocol based on the NIOSH Protocol for the Evaluation of Passive Monitors. The badge was exposed to relative humidities ranging from 11% to 92%, temperatures ranging from 7 C to 400 C and air velocities ranging from 5 cm/sec to 170 cm/sec. All experiments were conducted in a laboratory vapor generation system. Hydrofluoric acid, nitric acid, sulfuric acid, chlorine, hydrogen sulfide and organic acids showed no effect on the performance of the hydrogen chloride monitoring system. The passive badge and color scale system exceeded the accuracy requirements as defined by NIOSH. At ambient conditions, the mean coefficient of variation was 10.86 and the mean bias was 1.3%. This data was presented previously at the American Industrial Hygiene Conference and Exposition in Toronto, Canada in June 1999.

Chapman, K. B.↗

Evaluation of the Reliability of Passive Infrared (PIR) Occupancy Sensors for Residential Indoor Lighting

Solid-state lighting (SSL) technologies have penetrated the general illumination market in recent years, largely replacing conventional technologies such as incandescent and fluorescent lighting. Most of the initial excitement about light-emitting diode (LED) sources for SSL devices focused on their energy savings potential resulting from vast improvements in source efficiency and luminous efficacy compared with conventional illumination products. More recently, the focus has shifted toward other aspects of lighting application efficiency, namely intensity effectiveness and spectral efficiency, because of the ease of controlling both the light intensity of LEDs with drive voltage and the color properties of the LED-based illuminators. To capitalize on the energy savings of increased intensity effectiveness and spectral efficiency, a lighting control system (LCS) is often used. While the current penetration of LCSs is relatively modest, it is anticipated that lighting controls (i.e., connected lighting, controls and LED and conventional lighting) could have an installed penetration as higher as 46% by the year 2035, saving an additional 1.3 quads of energy. Despite the large energy savings that can be gained from using LCSs, standard test methods for evaluating sensors employed in LCSs and reliability data of the LCSs and their components are generally lacking. The National Electrical Manufacturers Association (NEMA) developed the only standard, NEMA WD 7-2011 (R2016), to test occupancy and motion sensor performance (herein referred to as “the NEMA protocol”). In a previous U.S. Department of Energy (DOE) effort, some concerns of the NEMA protocol were identified (e.g., strict height and weight limits on test subjects, large amounts of manual effort, sometimes inconsistent repeatability). During the current work, a consistent detection length test (DLT) and a Robotic Sensor Evaluation System (RoboSES) were developed to alleviate some of these concerns. RoboSES acts as a human surrogate by using thermal pads on a mannequin and a remote-controlled mobile base to test a sensor’s field of view (FOV). This report builds on the earlier DOE efforts to understand sensor technologies used in LCSs for general illumination. Specifically, this report describes the optimization of RoboSES, characterizes and establishes test methods to assess the reliability of multiple passive infrared (PIR) sensors, and reports the findings of robustness and reliability testing on two commercial PIR sensors intended for residential applications. The information presented in this report is gained from up to 4,000 hours (hrs) of accelerated stress tests (ASTs).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lithium thiostannate spinels: air-stable cubic semiconductors.

Lithium chalcogenide materials have been studied less than other alkali metal analogs and are of interest as ion conductors and semiconductors capable of thermal neutron detection. Herein, we describe the structural, thermal, magnetic, electronic, and ionic properties of a new family of cubic lithium thiospinels Li2MSn3S8 (M = Mg, Fe, Mn, Ni, Co) and Li1.66CuSn3.33S8. All compounds crystallize in the Fd (3) over barm space group and exhibit site occupancy disorder with Sn and M on the octahedral site for M = Mg, Fe, Mn, Ni, Co. The Li1.66CuSn3.33S8 compound also exhibits occupancy disorder on the tetrahedral sites between Li and Cu, as well as on the octahedral sites between Li and Sn. We demonstrate the ability to tune the physical properties of the compounds by changing their composition. By tuning the identity of the transition metal in the structure, the optical band gaps can vary between 0.91(2) and 2.19(2) eV, and electrical resistivities between 2.8 x 10(3) Omega-cm and 2.2 x 10(7)Omega-cm can be achieved. Density functional theory calculations for Li2MgSn3S8 and Li1.66CuSn3.33S8 suggest that both materials have indirect band gaps and significantly dispersive conduction bands. A bandwidth dispersion of 0.75 and 0.70 eV along the Gamma -> M direction in the conduction band are predicted for Li2MgSn3S8 and Li1.66CuSn3.33S8, respectively, with an electron effective mass of 0.49 and 0.55 m(e) at the Gamma point. The hole effective mass in the valence band is calculated to be 1.25 me at the M point and 0.75 me at the L point for Li2MgSn3S8 and Li1.66CuSn3.33S8, respectively. The ionic/electronic conductivity of each compound was determined using AC electrochemical impedance spectroscopy.

Quintero, Michael A.↗

Precision Kinematic Sunyaev--Zel'dovich Measurements Across Halo Mass and Redshift with DESI DR2 and ACT DR6: Part I. Luminous Red Galaxies

We present the most precise measurements of the kinetic Sunyaev-Zel'dovich (kSZ) effect around luminous red galaxies to date, detecting the signal at $18σ$ significance in both harmonic and configuration space. Our analysis cross-correlates 2.4 million spectroscopic LRGs from the Dark Energy Spectroscopic Instrument (DESI) DR2 sample with Data Release 6 (DR6) of the Atacama Cosmology Telescope (ACT). We develop a novel harmonic-space cross-correlation approach using momentum-weighted kSZ templates, yielding nearly uncorrelated bandpowers within a framework consistent with other large-scale structure analyses. By incorporating the LRG halo occupation distribution (HOD) and its uncertainty, we convert measured galaxy gas profiles into halo gas profiles and provide generalized Navarro-Frenk-White (GNFW) fitting profiles, providing empirical targets for tuning feedback efficiency in hydrodynamical simulations and for baryonic modeling in large-scale structure analyses. We find strong evidence that gas profiles do not trace dark matter, providing direct evidence for gas redistribution beyond gravitational collapse. Comparing to hydrodynamical simulations, our measurements favor feedback efficiencies exceeding those in the Battaglia profile, suggesting more efficient gas ejection in group-scale halos than previously predicted. Splitting by redshift, we detect the kSZ signal at SNR $\approx 5$--$10$ in each of four bins and find amplitude evolution consistent with the expected decline in mean halo mass at fixed comoving number density. Splitting by stellar mass, we study the scaling of kSZ amplitude with galaxy properties. Together with BGS and ELG measurements in Paper II, these results span $0.1 \lesssim z \lesssim 1.6$ across three galaxy populations, demonstrating the potential of spectroscopic kSZ to map circumgalactic gas and constrain baryonic feedback.

Qu, F. J. [KIPAC, Menlo Park; Stanford U., HEPL; S↗

lumicap v0.1

Automated HDR luminance imaging system designed for daylighting research and building science. It controls a fisheye-lens camera to capture time-lapse bracket sequences, merges them into calibrated HDR images, and runs a full post-processing pipeline — all unattended. Features: - Scheduled LDR bracket capture via gphoto2 - HDR merging with vignetting, ND filter, and fisheye projection corrections - Illuminance and luminance meter integration (Konica Minolta T-10A, LS-100/150) - Daylight glare probability (DGP) and solar position computation - Automated false-color rendering, JPEG thumbnails, and daily time-lapse video - CSV data logging per timestep Uses: - Long-term monitoring of daylight conditions in buildings - Glare analysis for occupant comfort research - Solar irradiance and sky luminance studies Advantages: - End-to-end automation — capture, calibration, analysis, and archiving run without manual intervention - Built on the proven Radiance toolchain, ensuring photometrically accurate HDR output - Hardware-agnostic meter support via serial auto-detection - Lightweight — no GUI overhead, deployable on a headless Raspberry Pi or similar embedded system

Wang, Taoning [Lawrence Berkeley National Laborato↗

NASA technical advances in aircraft occupant safety

NASA's aviation safety technology program examines specific safety problems associated with atmospheric hazards, crash-fire survival, control of aircraft on runways, human factors, terminal area operations hazards, and accident factors simulation. While aircraft occupants are ultimately affected by any of these hazards, their well-being is immediately impacted by three specific events: unexpected turbulence encounters, fire and its effects, and crash impact. NASA research in the application of laser technology to the problem of clear air turbulence detection, the development of fire resistant materials for aircraft construction, and to the improvement of seats and restraint systems to reduce crash injuries are reviewed.

Enders, J. H.↗

Nuclear X-Ray Activity in Low-surface-brightness Galaxies: Prospects for Constraining the Local Black Hole Occupation Fraction with a Chandra Successor Mission

About half of nearby galaxies have a central surface brightness>1 mag below that of the sky. The overall properties of these low-surface-brightness galaxies(LSBGs)remain understudied, and in particular we know very little about their massive black hole population. This gap must be closed to determine the frequency of massive black holes at z=0 as well as to understand their role in regulating galaxy evolution. Here we investigate the incidence and intensity of nuclear, accretion-powered X-ray emission in a sample of 32 nearby LSBGs with the Chandra X-ray Observatory. A nuclear X-ray source is detected in four galaxies(12.5%). Based on an X-ray binary contamination assessment technique developed for normal galaxies, we conclude that the detected X-ray nuclei indicate low-level accretion from massive black holes. The active fraction is consistent with that expected from the stellar mass distribution of the LSBGs, but not their total baryonic mass, when using a scaling relation from an unbiased X-ray survey of normal galaxies. This suggests that their black holes co-evolved with their stellar population. In addition, the apparent agreement nearly doubles the number of galaxies available within∼100 Mpc for which a measurement of nuclear activity can efficiently constrain the frequency of black holes as a function of stellar mass. We conclude by discussing the feasibility of measuring this occupation fraction to a few percent precision below ≲ 10^10 M(ʘ) with high-resolution, wide-field X-ray missions currently under consideration.

Edmund J. Hodges-Kluck↗

NASA technical advances in aircraft occupant safety

A NASA program to improve aircraft safety is discussed in terms of three areas of concentration: unexpected turbulence encounters, fire, and crash impact. To provide warning of clear air turbulence (CAT) so that the pilot can take evasive action, a laser Doppler system is described, which functions by measuring backscatter frequency radiation occurring in aerosols ahead of the aircraft. The system was found able to detect CAT, but at shorter than optimal ranges (10 km as opposed to 32 km). Fire safety has focused on both the early detection of fires through improved sensing methods, and on the development of fire-retardant materials, i.e., intumescent char-forming protective coatings. Crashworthiness is discussed in terms of the development of a survivable crash envelope and improved seat and restraint systems. To evaluate an aircraft for crashworthiness, finite-element computer programs are currently being developed which analyze both aircraft structural configurations and the intrinsic strength of aircraft materials.

Enders, J. H.↗

Cluster Expansion Analysis of Atomic Order in Li-Ion Battery Cathode Material LiCo y Ni 1-y O 2

A modified cluster-expansion treatment was developed recently to analyze atomic order in LiCo y Ni 1-y O 2 , a model cathode material for Li-ion batteries. In this treatment, referred to as a “spin-atom” cluster expansion, the occupant of a lattice site is identified by its spin state as well as its atomic species. Further, Effective Cluster Interaction (ECI) coefficients are derived from a large training data set (i.e., the set of atomic arrangements for which DFT calculations are performed) which is filtered by an anomaly detection algorithm to eliminate poorly converged DFT calculations. The cluster expansion incorporates Li-Ni (LN) exchange as well as intralayer Co-Ni (CN) exchange. Monte Carlo simulations based on the cluster expansion were applied to the Ni-rich part of the phase diagram. The simulations predict a miscibility gap between y = 0.05 and y = 0.65.

25 ENERGY STORAGE↗

High Altitude Radiations Relevant to the High Speed Civil Transport (HSCT)

The Langley Research Center (LaRC) performed atmospheric radiation studies under the SST development program in which important ionizing radiation components were measured and extended by calculations to develop the existing atmospheric ionizing radiation (AIR) model. In that program the measured neutron spectrum was limited to less than 10 MeV by the available 1960-1970 instrumentation. Extension of the neutron spectrum to high energies was made using the LaRC PROPER-3C monte carlo code. It was found that the atmospheric neutrons contributed about half of the dose equivalent and approximately half of the neutron contribution was from high energy neutrons above 10 MeV. Furthermore, monte carlo calculations of solar particle events showed that potential exposures as large as 10-100 mSv/hr may occur on important high latitude routes but acceptable levels of exposure could be obtained if timely descent to subsonic altitudes could be made. The principal concern was for pregnant occupants onboard the aircraft. As a result of these studies the FAA Advisory Committee on the Radiobiological Aspects of the SST recommended: 1. Crew members will have to be informed of their exposure levels 2. Maximum exposures on any flight to be limited to 5 mSv 3. Airborne radiation detection devices for total exposure and exposure rates 4. Satellite monitoring system to provide SST aircraft real-time information on atmospheric radiation levels for exposure mitigation 5. A solar forecasting system to warn flight operations of an impending solar event for flight scheduling and alert status. These recommendations are a reasonable starting point to requirements for the HSCT with some modification reflecting new standards of protection as a result of changing risk coefficients.

Wilson, J. W.↗

Dopant site-dependent luminescence from rare-earth doped dibarium octafluorohafnate Ba 2 HfF 8 nanocubes for radiation detection

Development of new host materials containing heavy elements for radiation detection is highly desirable. In this work, dibarium octafluorohafnate, Ba 2 HfF 8 , doped with rare-earth ions, was synthesized as cube-shaped nanocrystals via a facile hydrothermal method. The host lattice contains two Ba 2+ crystallographic sites, and dopants on these sites exhibit site-dependent photoluminescence (PL), cathodoluminescence (CL) and X-ray excited radioluminescence (RL) characteristics. Single doping contents were optimized as 25 mol% Tb 3+ and 5 mol% Eu 3+ . In Ba 2 HfF 8 :Tb 3+ –Eu 3+ codoped nanocrystals, preferrable occupation of Eu 3+ and Tb 3+ at two different Ba 2+ sites in the host lattice was observed. The nanocubes exhibited enhanced emissions over micron sized particles. In PL, the presence of Tb3+ ions significantly enhanced the emission intensity of Eu 3+ ions due to energy transfer from the Tb 3+ to Eu 3+ ions, while under high-energy irradiation in CL or RL, Tb 3+ emission was intensified. X-ray induced RL with afterglow in seconds was observed. Finally, it was found that the codoped sample showed higher sensitivity than the singly doped sample, indicating that codoping is an effective strategy to develop a scintillator with this host structure for high-energy radiation detection.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗