Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “normal measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Rheology melts and magmatic suspensions. I - Design and calibration of concentric cylinder viscometer with application to rhyolitic magma

The design and calibration of concentric cylinder viscometer for rhyolitic magma applications are described together with the methods of data reduction and error analysis. Experimental data are presented on two rhyolitic magmas (melt plus a small fraction of vapor) under conditions of varying temperature (1100-1350 C) and shear rate (0.05-13.0/sec) at 100 kPa total pressure. Data obtained include a first reported measurement of a normal stress coefficient for magma.

Spera, Frank J.↗

Streak camera based SLR receiver for two color atmospheric measurements

To realize accurate two-color differential measurements, an image digitizing system with variable spatial resolution was designed, built, and integrated to a photon-counting picosecond streak camera, yielding a temporal scan resolution better than 300 femtosecond/pixel. The streak camera is configured to operate with 3 spatial channels; two of these support green (532 nm) and uv (355 nm) while the third accommodates reference pulses (764 nm) for real-time calibration. Critical parameters affecting differential timing accuracy such as pulse width and shape, number of received photons, streak camera/imaging system nonlinearities, dynamic range, and noise characteristics were investigated to optimize the system for accurate differential delay measurements. The streak camera output image consists of three image fields, each field is 1024 pixels along the time axis and 16 pixels across the spatial axis. Each of the image fields may be independently positioned across the spatial axis. Two of the image fields are used for the two wavelengths used in the experiment; the third window measures the temporal separation of a pair of diode laser pulses which verify the streak camera sweep speed for each data frame. The sum of the 16 pixel intensities across each of the 1024 temporal positions for the three data windows is used to extract the three waveforms. The waveform data is processed using an iterative three-point running average filter (10 to 30 iterations are used) to remove high-frequency structure. The pulse pair separations are determined using the half-max and centroid type analysis. Rigorous experimental verification has demonstrated that this simplified process provides the best measurement accuracy. To calibrate the receiver system sweep, two laser pulses with precisely known temporal separation are scanned along the full length of the sweep axis. The experimental measurements are then modeled using polynomial regression to obtain a best fit to the data. Data aggregation using normal point approach has provided accurate data fitting techniques and is found to be much more convenient than using the full rate single shot data. The systematic errors from this model have been found to be less than 3 ps for normal points.

Varghese, Thomas K.↗

Stark broadening of Fe I 5383 A

Results are reported for a laboratory measurement of the electron broadening of the Fe I line at 5383 A as a function of electron density over the temperature range from 8000 to 12,000 K. A linear Z-pinch electrical discharge served as the spectroscopic light source in the experiment, and special precautions were taken to allow for optical-depth effects, which have been a major source of error in previous investigations. The results obtained include a Stark-broadening constant of 0.106 + or - 0.004 x 10 to the -16th A-cu cm at a mean temperature of 9500 K, an estimated Stark width/electron-broadened width ratio of 1.09 + or - 0.02, and a normalized electron-broadened width of 0.097 + or - 0.004 x 10 to the 16th A-cu cm. Comparison of the last result with a calculated value and with a previous measurement indicates that the present measurement is approximately 38% larger than the value measured earlier.

Freudenstein, S.↗

Small error dynamics and the predictability of atmospheric flows

In this paper, linear small-error theory is applied to the study of weather predictability. A simple baroclinic shear model and a barotropic channel model with a localized jet are used as examples. It is shown that increase in error on synoptic forecast time scales is controlled by rapidly growing perturbations that are not of normal mode form. Unpredictable regimes are not necessarily associated with larger exponential growth rates than are relatively more predictable regimes. Model problems illustrating baroclinic and barotropic dynamics suggest that asymptotic measures of divergence in phase space, while applicable in the limit of infinite time, may not be appropriate over time intervals addressed by present synoptic forecast.

Farrell, Brian F.↗

TRMM On-Orbit Performance Reassessed After Control Change

The Tropical Rainfall Measuring Mission (TRMM) spacecraft, a joint mission between the U.S. and Japan, launched onboard an H-I1 rocket on November 27, 1997, and transitioned in August, 2001, from an average operating altitude of 350 kilometers to 402.5 kilometers. Due to problems using the Earth Sensor Assembly (ESA) at the higher altitude, TRMM switched to a backup attitude control mode. Prior to the orbit boost TRMM controlled pitch and roll to the local vertical using ESA measurements while using gyro data to propagate yaw attitude between yaw updates from the Sun sensors. After the orbit boost, a Kalman filter used 3-axis gyro data with Sun sensor and magnetometers to estimate onboard attitude. While originally intended to meet a degraded attitude accuracy of 0.7 degrees, the new control mode met the original 0.2 degree attitude accuracy requirement after improving onboard ephemeris prediction and adjusting the magnetometer calibration onboard. Independent roll attitude checks using a science instrument, the Precipitation Radar (PR) which was built in Japan, provided a novel insight into the pointing performance. The PR data helped identify the pointing errors after the orbit boost, track the performance improvements, and show subtle effects from ephemeris errors and gyro bias errors. It also helped identify average bias trends throughout the mission. Roll errors tracked by the PR from sample orbits pre-boost and post-boost are shown in Figure 1. Prior to the orbit boost, the largest attitude errors were due to occasional interference in the ESA. These errors were sometime larger than 0.2 degrees in pitch and roll, but usually less, as estimated from a comprehensive review of the attitude excursions using gyro data. Sudden jumps in the onboard roll show up as spikes in the reported attitude since the control responds within tens of seconds to null the pointing error. The PR estimated roll tracks well with an estimate of the roll history propagated using gyro data. After the orbit boost, the attitude errors shown by the PR roll have a smooth sine-wave type signal because of the way that attitude errors propagate with the use of gyro data. Yaw errors couple at orbit period to roll with 1/4 orbit lag. By tracking the amplitude, phase, and bias of the sinusoidal PR roll error signal, it was shown that the average pitch rotation axis tends to be offset from orbit normal in a direction perpendicular to the Sun direction, as shown in Figure 2 for a 200 day period following the orbit boost. This is a result of the higher accuracy and stability of the Sun sensor measurements relative to the magnetometer measurements used in the Kalman filter. In November, 2001 a magnetometer calibration adjustment was uploaded which improved the pointing performance, keeping the roll and yaw amplitudes within about 0.1 degrees.

Bilanow, Stephen↗

Status of equation of state of solids

The results of equation of state (pressure-volume-temperature) measurements for the rare gas solids, alkali metals and alkali halides are reviewed. The precision and errors associated with the techniques most commonly used to obtain measurements of volume as a function of pressure, including piston volume displacement, ultrasonic, shock wave, and Brillouin scattering techniques, length change measurement, and combined length change and ultrasonic transit techniques, are presented. The various equations of state which are normally used to represent these measurements are discussed.

Ruoff, A. L.↗

Flight motor set 360L007 (STS-33R)

Flight motor set 360L007 was launched as part of NASA space shuttle mission STS-33R. As with all previous redesigned solid rocket motor launches, overall motor performance was excellent. There were no debris concerns for either motor. Both motors exhibited unbonds on one factory joint weatherseal. All ballistics contract end item specification parameters were verified, with the exception of ignition interval and rise rates. Ignition interval and rise rates could not be verified due to the elimination of developmental flight instrumentation from fourth flight and subsequent, but the low sample rate data that were available showed nominal propulsion performance. All ballistic and mass property parameters closely matched the predicted values and were well within the required contract end item specification levels that could be assessed. All 108 Ground Environment Instrumentation (GEI) measurements performed properly throughout the prelaunch phase. Evaluation of the GEI measurements again verified thermal model analysis data and showed agreement with predicted environmental effects. No launch commit criteria thermal violations occurred. All joint heaters operated normally, but a high voltage reading was noted on the left hand aft heater, which was immediately determined to be a voltage sensor error and not a heater anomaly due to no current increase. Postflight inspection again verified superior performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated both nozzles performed as expected during flight. All combustion gas was contained by insulation in the field and case-to-nozzle joints.

Garecht, Diane↗

Advanced Characterisation of Aerosol Size Properties from Measurements of Spectral Optical Depth Using the GRASP Algorithm

This study evaluates the potential of using aerosol optical depth (τ (sub a)) measurements to characterise the microphysical and optical properties of atmospheric aerosols. With this aim, we used the recently developed GRASP (Generalized Retrieval of Aerosol and Surface Properties) code for numerical testing of six different aerosol models with different aerosol loads. The direct numerical simulations (self-consistency tests) indicate that the GRASP-AOD retrieval provides modal aerosol optical depths (fine and coarse) to within 0.01 of the input values. The retrieval of the fine-mode radius, width and volume concentration are stable and precise if the real part of the refractive index is known. The coarse-mode properties are less accurate, but they are significantly improved when additional a priori information is available. The tests with random simulated errors show that the uncertainty in the bimodal log-normal size distribution parameters increases as the aerosol load decreases. Similarly, the reduction in the spectral range diminishes the stability of the retrieved parameters. In addition to these numerical studies, we used optical depth observations at eight AERONET locations to validate our results with the standard AERONET inversion products. We found that bimodal log-normal size distributions serve as useful input assumptions, especially when the measurements have inadequate spectral coverage and/or limited accuracy, such as moon photometry. Comparisons of the mode median radii between GRASP-AOD and AERONET indicate average differences of 0.013µm for the fine mode and typical values of 0.2–0.3µm for the coarse mode. The dominant mode (i.e. fine or coarse) indicates a 10 % difference in mode radii between the GRASP-AOD and AERONET inversions, and the average of the difference in volume concentration is around 17 % for both modes. The retrieved values of the fine-mode τ(sub a)(500) using GRASP-AOD are generally between those values obtained by the standard AERONET inversion and the values obtained by the AERONET spectral deconvolution algorithm (SDA), with differences typically lower than 0.02 between GRASP-AOD and both algorithms. Finally, we present some examples of application of GRASP-AOD inversion using moon photometry and the airborne PLASMA sun photometer during the ChArMEx summer 2013 campaign in the western Mediterranean.

Torres, Benjamin↗

Effect of nonideal square-law detection on static calibration in noise-injection radiometers

The effect of nonideal square-law detection on the static calibration for a class of Dicke radiometers is examined. It is shown that fourth-order curvature in the detection characteristic adds a nonlinear term to the linear calibration relationship normally ascribed to noise-injection, balanced Dicke radiometers. The minimum error, based on an optimum straight-line fit to the calibration curve, is derived in terms of the power series coefficients describing the input-output characteristics of the detector. These coefficients can be determined by simple measurements, and detection nonlinearity is, therefore, quantitatively related to radiometric measurement error.

Hearn, C. P.↗

Satellite remote sensing of surface energy balance - Success, failures, and unresolved issues in FIFE

Utilizing single-view-angle visible and NIR satellite observations, it was possible to make the necessary radiometric corrections to produce reliable estimates of the simple ratio and the normalized difference vegetation index as inputs to surface evaporation models. Agreement was achieved between helicopter and satellite measures of surface reflectance to within +/-1 percent absolute for both the visible and the NIR bands. A theoretical calculation utilizing radiative transfer models indicates that this translates into a +/-10 percent error in the estimation in Fpar.

Hall, Forrest G.↗

Calculator for Agricultural Water Use Fractions in California

Improved quantification of agricultural water use efficiency is a primary focus of California's Water Conservation Act. The California Department of Water Resources (CDWR), after extensive stakeholder consultation, has published methods and indicators to help identify opportunities for improved efficiency of irrigation management at various spatial scales. Additional 2017 legislation directs water suppliers to quantify water use efficiency using the CDWR metrics to support preparation of agricultural water management plans. The IrriQuest calculator derives the Crop Consumptive Use Fraction (CCUF), a foundational metric relating seasonal crop evapotranspiration (ET) to total applied water. Satellite normalized difference vegetation index (NDVI) data are used to develop fractional canopy cover timeseries. Additional key inputs include daily reference ET, irrigation volume, irrigation method, precipitation, soil texture and crop type. IrriQuest estimates of seasonal crop ET show less than 10% mean absolute error compared to ground-based measurements of several annual and perennial crops monitored by sensor deployment in commercial fields. Two additional indicators build on CCUF. The Agronomic Water Use Fraction adds consideration of water applied for beneficial purposes such as pre-plant soil preparation, soil salinity management, and climate control. Total Water Use Fraction additionally accounts for water applied for environmental purposes such as maintenance of wetland and riparian habitat. A convenient on-line portal is under development for CCUF estimation and a standalone spreadsheet is available for computation of all three use fractions.

Calculator↗

Effects of edge-rounding on geodesic lenses

A method that eliminates the need for a mathematical model is described for measuring the absolute light intensity radiated from volume chemiluminescent and fluorescent sources. This technique applies to a uniform cylindrical luminous volume, which is the geometry most often practical for the study of flowing chemiluminescent and fluorescent fluids. In this method, the necessary integration over a luminous volume is carried out experimentally, using a calibrated piston source that has as its head a disk of uniform luminosity. The relatively small total error in absolute light intensity measurements with the piston source technique represents a significant improvement over competing comparison methods. The construction of a piston source to fit the cross section of a particular cylindrical volume is straightforward, and its calibration against a standard source can be readily made while exercising normal precautions.

Wood, V. E.↗

Absolute measurement of the extreme UV solar flux

A windowless rare-gas ionization chamber has been developed to measure the absolute value of the solar extreme UV flux in the 50-575-A region. Successful results were obtained on a solar-pointing sounding rocket. The ionization chamber, operated in total absorption, is an inherently stable absolute detector of ionizing UV radiation and was designed to be independent of effects from secondary ionization and gas effusion. The net error of the measurement is + or - 7.3 percent, which is primarily due to residual outgassing in the instrument, other errors such as multiple ionization, photoelectron collection, and extrapolation to the zero atmospheric optical depth being small in comparison. For the day of the flight, Aug. 10, 1982, the solar irradiance (50-575 A), normalized to unit solar distance, was found to be 5.71 + or - 0.42 x 10 to the 10th photons per sq cm sec.

Carlson, R. W.↗

Radiative properties of Cirrus clouds: FIRE IFO case October 28, 1986

A description of the radiative properties of two cirrus clouds sampled on 10/28/88 in the FIRE cirrus IFO is presented. The clouds are characterized in terms of the broadband infrared effective emittance, cloud fractional absorptance, shortwave heating rate, cloud albedo and vertical velocity. The broadband fluxes used in these calculations were obtained from measurements made by pyranometers and pyrgeometers. The shortwave irradiances were corrected to a horizontal plane and normalized to the same time by taking into account Sabreliner flight information (i.e., pitch, roll, heading and angle of attack), as well as sun-earth geometry considerations. Since only one aircraft was used, broadband fluxes at different levels in the cloud were not measured simultaneously. As a result, sampling errors may occur due to the nonsteady state of the cloud field or due to the possibility that the flight legs were not flown directly above or below each other. To minimize these errors and to simplify the analysis, the necessary variables were averaged and the averages used in the calculations. The downwelling shortwave and longwave irradiances were used as selection criteria to remove cloud free data encountered along the data sampling leg.

Hein, Paul F.↗

Derivation and Application of a Global Albedo yielding an Optical Brightness To Physical Size Transformation Free of Systematic Errors

Orbital object data acquired via optical telescopes can play a crucial role in accurately defining the space environment. Radar systems probe the characteristics of small debris by measuring the reflected electromagnetic energy from an object of the same order of size as the wavelength of the radiation. This signal is affected by electrical conductivity of the bulk of the debris object, as well as its shape and orientation. Optical measurements use reflected solar radiation with wavelengths much smaller than the size of the objects. Just as with radar, the shape and orientation of an object are important, but we only need to consider the surface electrical properties of the debris material (i.e., the surface albedo), not the bulk electromagnetic properties. As a result, these two methods are complementary in that they measure somewhat independent physical properties to estimate the same thing, debris size. Short arc optical observations such as are typical of NASA's Liquid Mirror Telescope (LMT) give enough information to estimate an Assumed Circular Orbit (ACO) and an associated range. This information, combined with the apparent magnitude, can be used to estimate an "absolute" brightness (scaled to a fixed range and phase angle). This absolute magnitude is what is used to estimate debris size. However, the shape and surface albedo effects make the size estimates subject to systematic and random errors, such that it is impossible to ascertain the size of an individual object with any certainty. However, as has been shown with radar debris measurements, that does not preclude the ability to estimate the size distribution of a number of objects statistically. After systematic errors have been eliminated (range errors, phase function assumptions, photometry) there remains a random geometric albedo distribution that relates object size to absolute magnitude. Measurements by the LMT of a subset of tracked debris objects with sizes estimated from their radar cross sections indicate that the random variations in the albedo follow a log-normal distribution quite well. In addition, this distribution appears to be independent of object size over a considerable range in size. Note that this relation appears to hold for debris only, where the shapes and other properties are not primarily the result of human manufacture, but of random processes. With this information in hand, it now becomes possible to estimate the actual size distribution we are sampling from. We have identified two characteristics of the space debris population that make this process tractable and by extension have developed a methodology for performing the transformation.

Mulrooney, Dr. Mark K.↗

Bringing the cross-correlation method up to date

The cross-correlation (XC) method of Tonry & Davis (1979, AJ, 84, 1511) is generalized to arbitrary parametrized line profiles. In the new algorithm the correlation function itself, rather than the observed galaxy spectrum, is fitted by the model line profile: this removes much of the complication in the error analysis caused by template mismatch. Like the Fourier correlation quotient (FCQ) method of Bender (1990, A&A, 229, 441), the inferred line profiles are, up to a normalization constant, independent of template mismatch as long as there are no blended lines. The standard reduced chi(exp 2) is a good measure of the fit of the inferred velocity distribution, largely decoupled from the fit of the spectral template. The updated XC method performs as well as other recently developed methods, with the added virtue of conceptual simplicity.

Statler, Thomas↗

Development of an In-line Urine Monitoring System for the International Space Station

Exposure to microgravity during space flight causes bone loss when calcium and other metabolic by-products are excreted in urine voids. Frequent and accurate measurement of urine void volume and constituents is thus essential in determining crew bone loss and the effectiveness of the countermeasures that are taken to minimize this loss. Earlier space shuttle Urine Monitoring System (UMS) technology was unable to accurately measure urine void volumes due to the cross-contamination that took place between users, as well as to fluid system instabilities. Crew urine voids are currently collected manually in a flexible plastic bag that contains a known tracer quantity. A crew member must completely mix the contents of this bag before withdrawing a representative syringe sample for later ground analysis. The existing bag system accuracy is therefore highly dependent on mixing technique. The International Space Station (ISS) UMS has been developed as an automated device that collects urine from the Waste and Hygiene Compartment (WHC) urinal funnel interface, separates the urine, measures void volume, and allows for syringe sampling. After the ISS UMS has been used by a crew member, it delivers urine to the WHC for normal processing. The UMS plumbing is then flushed with a small volume of water. The current ISS UMS design incorporates an innovative rotary separator that minimizes foaming, consequently greatly reducing cross-contamination among urine voids (less than 0.5 mL urine) while also providing accurate volume measurements (less than 2 percent error for 100 to 1,000 mL void volumes). ISS UMS performance has been validated through extensive ground tests and reduced-gravity aircraft flights. The locker-sized ISS UMS is currently undergoing a design modification that will permit it to interface with the ISS Node 3 WHC Russian toilet (ACY) hardware. The operating principles, characteristics, and results of this design modification are outlined here.

Broyan, James Lee, Jr.↗

A measurement of the value of the Hubble constant from the X-ray properties and the Sunyaev-Zel'dovich effect of Abell 665

A comparison of the X-ray properties and the Sunyaev-Zel'dovich (SZ) effect for a cluster of galaxies can be used to measure the distance of the cluster and hence the Hubble constant. This method was applied to the rich cluster Abell 665. The relative normalization of X-ray and SZ-effect data leads to an estimated Hubble constant of H sub 0 = 40 + or - 9 km/s Mpc if only the random errors are included. When the possible systematic errors are added in quadrature, the range of possible values of the Hubble constants expands to (40 to 50) + or - 12 km/s Mpc.

Birkinshaw, M.↗