Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multiplexing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Fiber optic wavelength division multiplexing: Principles and applications in telecommunications and spectroscopy

Design and fabrication tradeoffs of wavelength division multiplexers are discussed and performance parameters are given. The same multiplexer construction based on prism gratings has been used in spectroscopic applications, in the wavelength region from 450 to 1600 nm. For shorter wavelengths down to 200 nm, a similar instrument based on longer fibers (500 to 1000 micrometer) has been constructed and tested with both a fiber array and a photodiode detector array at the output.

Erdmann, R. K.↗

Wavelength division multiplexed fiber optic absolute position encoder

A wavelength division multiplexing (WDM) method for fiber optic sensors is proposed which uses a broadband light source and narrow bandpass thin film optical filter coatings on cylindrical graded index lenses. In the WDM system described here, all bits are multiplexed onto a single signal return fiber by assigning each bit a unique wavelength. A multielement photodetector array is used as the encoded position information is in parallel. Preliminary prototype test results are presented.

Park, Eric D.↗

Multiplexing readout channels in proportional counters

Proportional counters are important instruments used in sensing hard x-rays. The possibility is described of doubling the number of readout channels in the detector without increasing the electronics needed to amplify channel signals. This suggests that it should be possible, conversely, to reduce the number of amplifiers, thereby reducing the weight and energy budget of the instrument. Various numerical multiplexing schemes are analyzed, and a computer program is presented that can reconstruct multiplexed channel outputs with very good accuracy.

Caristi, James↗

Multiplex Fabry-Perot interferometer

Attention is given to a Fabry-Perot interferometer (FPI) technique in which one of the etalon plates is moved over a large optical distance while the other remains fixed, thus exploiting the multiplex advantage of the instrument. This technique involves the application of Fourier-transform spectrometer to the multiple harmonics passing through the FPI etalon. It is shown that the multiplex FPI acts as several Michelson interferometers working at the same time, over the same spectral interval, and at different spectral resolutions. A high spectral resolution has been obtained over a large wavenumber interval, while the advantage of a reasonable scan length has been retained.

Hays, Paul B.↗

256x256 switched-FET multiplexer for spaceborne astronomical applications

A novel cryogenic design of a source follower per detector (SFD) direct readout multiplexer is demonstrated. This design has proven to be a good prototype for the development of new low-noise large-area cryogenic multiplexers. In the absence of clocking noise, the readout demonstrates as low as about 30 electrons of rms read noise. There is still an excess noise component feeding through when the array is clocked, which manifests itself only at the lower temperatures. The shape of this component is dependent on a number of the bias voltages, and especially on the temperature of the chip. Analysis of the noise spectral density of the unit cell under various bias conditions shows that there is an excess spectral noise component at the lower temperatures.

Mcmurray, Robert E., Jr.↗

A radiation-hard, low-background multiplexer design for spacecraft imager applications

A possible multiplexer design for the focal plane for the Cassini Visible and Infrared Mapping Spectrometer (VIMS) is reviewed. The instrument's requirements for the multiplexed array are summarized. The VIMS instrument has a modest radiation-hardness requirement due to the trajectory and planetary environments in which the instrument will be required to operate. The total ionizing dose hardness requirement is a few tens of kilorads. A thin-gate oxide of a few hundred angstroms thickness is to be used. Field hardness is to be achieved by guard bands or hardened dielectric isolation. The design is argued to meet the low-noise and radiation-hardness required for imaging at Saturn. The design is versatile enough to provide double-correlated and double-uncorrelated sampling, which is accomplished in the signal processing electronics outside the focal plane.

Staller, Craig↗

Analysis of the eastern range multiplexed fiber optic IRIG B120 distribution system

A study was conducted to assess the effects of transmitting a precision clock synchronization signal over a commercial multiplexed fiber optic communication system. This study is an evaluation of the distortion and jitter introduced into the signal by this type of transmission system. An analysis comparing signal quality at the multiplexing and demultiplexing ends of the fiber optic communication system shows that the amplitude and phase distortion added to the clock synchronization signal by the transmission system is minimal.

Duncan, Michael J.↗

Wavelength Division Multiplexing Scheme for Radio-Frequency Single Electron Transistors

We describe work on a wavelength division multiplexing scheme for radio-frequency single electron transistors. We use a network of resonant impedance matching circuits to direct applied rf carrier waves to different transistors depending on carrier frequency. Using discrete components, we made a two-channel demonstration of this concept and successfully reconstructed input signals with small levels of cross coupling. A lithographic version of the rf circuits had measured parameters in agreement with electromagnetic modeling, with reduced cross capacitance and inductance, and should allow 20 to 50 channels to be multiplexed.

Stevenson, Thomas R.↗

Multiplexing of Radio-Frequency Single Electron Transistors

We present results on wavelength division multiplexing of radio-frequency single electron transistors. We use a network of resonant impedance matching circuits to direct applied rf carrier waves to different transistors depending on carrier frequency. A two-channel demonstration of this concept using discrete components successfully reconstructed input signals with small levels of cross coupling. A lithographic version of the rf circuits had measured parameters in agreement with electromagnetic modeling, with reduced cross capacitance and inductance, and should allow 20 to 50 channels to be multiplexed.

Stevenson, Thomas R.↗

Multiplexed Readout of Thermal Bolometers with Superconducting Transition Edge Thermometers

History shows that in astronomy, more is better. In the near future, direct detector arrays for the far-infrared and submillimeter will contain hundreds to thousands of elements. A multiplexed readout is necessary for practical implementation of such arrays, and has been developed using SQUIDs. The technology permits a 32 x 32 array of bolometers to be read out using approximately 100 wires rather than the >2000 needed with direct wiring. These bolometer arrays are made by micromachining techniques, using superconducting transition edge sensors as the thermistors. We describe the development of this multiplexed superconducting bolometer array architecture as a step toward bringing about the first astronomically useful arrays of this design. This technology will be used in the Submillimeter and Far Infrared Experiment (SAFIRE) instrument on Stratospheric Observatory for Infrared Astronomy (SOFIA), and is a candidate for a wide variety of other spectroscopic and photometric instruments.

Benford, Dominic J.↗

Novel Multiplexing Technique for Detector and Mixer Arrays

Future submillimeter and far-infrared space telescopes will require large-format (many 1000's of elements) imaging detector arrays to perform state-of-the-art astronomical observations. A crucial issue related to a focal plane array is a readout scheme which is compatible with large numbers of cryogenically-cooled (typically < 1 K) detectors elements. When the number of elements becomes of the order of thousands, the physical layout for individual readout amplifiers becomes nearly impossible to realize for practical systems. Another important concern is the large number of wires leading to a 0.1-0.3 K platform. In the case of superconducting transition edge sensors (TES), a scheme for time-division multiplexing of SQUID read-out amplifiers has been recently demonstrated. In this scheme the number of SQUIDs is equal to the number (N) of the detectors, but only one SQUID is turned on at a time. The SQUIDs are connected in series in each column of the array, so the number of wires leading to the amplifiers can be reduced, but it is still of the order of N. Another approach uses a frequency domain multiplexing scheme of the bolometer array. The bolometers are biased with ac currents whose frequencies are individual for each element and are much higher than the bolometer bandwidth. The output signals are connected in series in a summing loop which is coupled to a single SQUID amplifier. The total number of channels depends on the ratio between the SQUID bandwidth and the bolometer bandwidth and can be at least 100 according to the authors. An important concern about this technique is a contribution of the out-of-band Johnson noise which multiplies by factor N(exp 1/2) for each frequency channel. We propose a novel solution for large format arrays based on the Hadamard transform coding technique which requires only one amplifier to read out the entire array of potentially many 1000's of elements and uses approximately 10 wires between the cold stage and room temperature electronics. This can significantly reduce the complexity of the readout circuits.

Karasik, Boris S.↗

Broadband Direct Detection Submillimeter Spectrometer with Multiplexed Superconducting Transition Edge Thermometer Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers as direct detectors (i.e., with cold electrons) for spectroscopy. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer for the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing 5 orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering Delta lambda/lambda = 1/7 at a resolution of delta lambda/lambda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve Doppler-broadened line emission from external galaxies. FIBRE has been operated in the 350 Am (850 GHz) band. These bands cover line emission from the important star formation tracers neutral carbon [CI] and carbon monoxide (CO).

Benford, D. J.↗

Operational Limitations of the High Rate Frame Multiplexer (HRFM) Onboard the International Space Station(ISS)-and How These Limitations Affect Payload Developers (PDs) and International Partners (IPs)

The data system onboard the United States Operating Segment (USOS) of the ISS is currently used to capture, route, record and downlink high-rate science data from experiments inside the US Lab. Once NASDA's Japanese Experiment Module (JEM) and ESA's Attached Pressurized Module (APM) are launched - in the 2004 to 2005 timeframe - data from these facilities will also be routed to the ground using the USOS data system. A critical component of the USOS data system is the High Rate Frame Multiplexer (HRFM). The HRFM combines multiple data/video inputs and combines them into one data stream. This Ku-band data stream is then routed through the Tracking and Data Relay Satellite (TDRS) system to the ground. The Data Management Coordinator (DMC) - located at the Marshall Space Flight Center's Payload Operations Center (POC) - is responsible for commanding and controlling the HRFM. The HRFM can multiplex a maximum of eight digital data sources and four digital video sources. Thus far, this limitation has not been constraining to operations. However, once the JEM and APM are integrated, the HRFM limitations will become a major constraint to science operations onboard. The purpose of this paper is to characterize the limitations of the HRFM and to explain how these limitations can be successfully managed. With this information, Payload Developers and International Partners will be able to more effectively utilize the data systems onboard the ISS. Ultimately, more science data can be captured and downlinked to Flight Controllers and Scientists on the ground.

Mixson, Charles D.↗

System for Multiplexing Acoustic Emission (AE) Instrumentation

An acoustic monitoring device has at least two acoustic sensors with a triggering mechanism and a multiplexing circuit. After the occurrence of a triggering event at a sensor, the multiplexing circuit allows a recording component to record acoustic emissions at adjacent sensors. The acoustic monitoring device is attached to a solid medium to detect the occurrence of damage.

Prosser, William H.↗

Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan-Cassini entry probe, which is being jointly planned by NASA and the European Space Agency (ESA), might be launched as early as 1994. As in the Pioneer mission, limited time--perhaps only 3-4 h--will be available for the completion of all analyses while the probe descends through the atmosphere. A conventional GC or GC-MS system would be able to analyze no more than two aerosol and two gas samples during the probe's descent. Conventional GC also is limited by the sensitivity of the detector and by the sample volume. For the Titan mission, the sensitivity problems will be worse because the atmospheric pressure at the time of instrument deployment is expected to be < 3 torr. Consequently, the sample volume might not be large enough to satisfy the detector sensitivity requirements. Because of such limitations, alternative GC analysis techniques have been investigated for future NASA missions. Multiplex gas chromatography has been investigated as a possible candidate for chemical analysis within a spacecraft or other restricted environment, and chemical modulators have been developed and used when needed with this technique to reduce the size and weight of the instrumentation. Also, several new multiplex techniques have been developed for use in specific applications.

NASA Center ARC↗

Enhancements to a Superconducting Quantum Interference Device (SQUID) Multiplexer Readout and Control System

Far-infrared detector arrays such as the 16x32 superconducting bolometer array for the SAFIRE instrument (flying on the SOFIA airborne observatory) require systems of readout and control electronics to provide translation between a user-driven, digital PC and the cold, analog world of the cryogenic detector. In 2001, the National Institute of Standards and Technology (NIST) developed their Mark III electronics for purposes of control and readout of their 1x32 SQUID Multiplexer chips. We at NASA s Goddard Space Flight Center acquired a Mark 111 system and subsequently designed upgrades to suit our and our collaborators purposes. We developed an arbitrary, programmable multiplexing system that allows the user to cycle through rows in a SQUID array in an infinite number of combinations. We provided hooks in the Mark III system to allow readout of signals from outside the Mark 111 system, such as telescope status information. Finally, we augmented the heart of the system with a new feedback algorithm implementation, flexible diagnostic tools, and informative telemetry.

Forgione, J.↗

The Application of Fiber Optic Wavelength Division Multiplexing in RF Avionics

This paper demonstrates a successful application of wavelength division multiplexing (WDM) to the avionics environment to support analog RF signal transmission. We investigate the simultaneous transmission of four RF signals (channels) over a single optical fiber. These four analog channels are sequentially multiplexed and demultiplexed at different points along a fiber optic backbone to more closely emulate the conditions found onboard aircraft. We present data from measurements of signal-to-noise ratio (SNR), transmission response (loss and gain), group delay that defines phase distortion, and dynamic range that defines nonlinear distortion. The data indicate that WDM is well-suited for avionics applications.

Ngo, Duc↗

Time-multiplexed, optically-addressed, gigabit optical crossbar switch

A time-multiplexed, optically-addressed, crossbar switch (38) is provided using a two-dimensional, optically-addressed, reflective spatial light modulator (O-SLM) (20). Since the optical addressing is time-multiplexed, only N addressing lines are required for an N.times.N crossbar, rather than the N.sup.2 lines needed in the prior art. This reduction in addressing lines makes possible the development of enormous crossbar switches, such as 100.times.100, for the first time. In addition, since data paths remain entirely in the optics domain, data speeds can reach the multi-gigabit level. In the switch, a row (40) of N inputs (42) at the read wavelength is spread over one axis of the O-SLM. The light is refocused along the other axis to an output array (48) of detectors (50), so that each input has the potential to talk to any one output. The O-SLM is normally off, i.e., non-reflective, so that the output is, in the absence of an input signal, zero. A one-dimensional array (52) of lasers (54) at the write wavelength is imaged onto the O-SLM. Each laser scans across an entire row of the O-SLM; where the laser is on, it turns on a portion of the O-SLM and establishes a connection between a particular input and a particular output. A full row is scanned in a time much shorter than the response time of the O-SLM, so that state of the O-SLM is capacitively stored and dynamically refreshed. The scanning is accomplished by tuning the wavelength of the laser and passing it through a grating, which sweeps the beam in space.

Lang, Robert J.↗