Vacuum-ultraviolet reflectometer

Baffle, three-blade chopper, and split spherical mirror transmit alternating dual beam into integrating sphere. Alternating reference and sample beams are detected by high gain photomultiplier and modified logarithmic ratiometer. Device is useful in fusion research, high power laser work, and spectrometer or monochromator construction.

Allen, T. H.↗

Miniature carbon dioxide sensor

Infrared absorption spectrometer with dual wave length monochromator has several valuable features: 3.4 by 1.6 inch size; accuracy within plus or minus 5% from 0 to 30 mm Hg; instantaneous and temperature-independent response time; negligible O2 and N2 effects and less than 0.5% water vapor effect; 2.5 W power consumption; no moving parts; and 1.5 and 30 mm Hg CO2 in range.

Bordeaux, J.↗

Digital TV processing system

Two digital video data compression systems directly applicable to the Space Shuttle TV Communication System were described: (1) For the uplink, a low rate monochrome data compressor is used. The compression is achieved by using a motion detection technique in the Hadamard domain. To transform the variable source rate into a fixed rate, an adaptive rate buffer is provided. (2) For the downlink, a color data compressor is considered. The compression is achieved first by intra-color transformation of the original signal vector, into a vector which has lower information entropy. Then two-dimensional data compression techniques are applied to the Hadamard transformed components of this last vector. Mathematical models and data reliability analyses were also provided for the above video data compression techniques transmitted over a channel encoded Gaussian channel. It was shown that substantial gains can be achieved by the combination of video source and channel coding.

Source record↗

Ion temperatures in HIP-1 and SUMMA from charge-exchange neutral optical emission spectra

Ion temperatures were obtained from observations of the H sub alpha, D sub alpha, and He 587.6 nm lines emitted from hydrogen, deuterium, and helium plasmas in the SUMMA and HIP-1 mirror devices at Lewis Research Center. Steady state discharges were formed by applying a radially inward dc electric field between cylindrical or annular anodes and hollow cathodes located at the peaks of the mirrors. The ion temperatures were found from the Doppler broadening of the charge-exchange components of spectral lines. A statistical method was developed for obtaining scaling relations of ion temperature as a function of current, voltage, and magnetic flux density. Derivations are given that take into account triangular monochromator slit functions, loss cones, and superimposed charge-exchange processes. In addition, the Doppler broadening was found to be sensitive to the influence of drift on charge-exchange cross section. The effects of finite ion-cyclotron radius, cascading, and delayed emission are reviewed.

Patch, R. W.↗

Ultraviolet remote sensing of atmospheric ozone from payloads using Shuttle capabilities

Previous atmospheric ozone observations using an ultraviolet double monochromator to measure the absorption of back-scattered solar radiation between 255 nm and 340 nm have provided information on the global total ozone distribution as well as its vertical profile. This information can be used to structure the comprehensive ozone observations that are needed to provide a better understanding of ozone formation and destruction mechanisms. Some potential ozone threats, especially that from photodissociation of fluorocarbons, make Shuttle-based observations especially timely. Because of the nature of the global ozone-transport process, measurements must be performed from space on a global scale with sufficient resolution and accuracy to determine the total amount of atmospheric ozone. A better understanding of ozone processes in global regions inaccessible from previous platforms is needed to complete this ozone data base. This paper describes the potential for Shuttle payloads to provide the required information.

Krueger, A. J.↗

ATS-6 - Television Relay Using Small Terminals Experiment

The Television Relay Using Small Terminals (TRUST) Experiment was designed to advance and promote the technology of broadcasting satellites. A constant envelope television FM signal was transmitted at C band to the ATS-6 earth coverage horn and retransmitted at 860 MHz through the 9-m antenna to a low-cost direct-readout ground station. The experiment demonstrated that high-quality television and audio can be received by low-cost direct-receive ground stations. Predetection bandwidths significantly less than predicted by Carson's rule can be utilized with minimal degradation of either monochrome or color pictures. Two separate techniques of dual audio channel transmission have been demonstrated to be suitable for low-cost applications.

Miller, J. E.↗

Measurements of spectral and total emittance of reinforced carbon-carbon

Elevated temperature measurements of the spectral emittance of reinforced carbon-carbon (RCC) as the thermal protection material for the leading edge areas of the Space Shuttle Orbiter were carried out in situ, with environments provided by arc-heated streams of air and argon. A monochromator, infrared pyrometers, and thermocouples were used in evaluating the response of the RCC test specimens during the emittance measurements. Results indicate that the material is nongray, with lowest spectral emittance at the short wavelengths and with relatively high total emittance. The trend of the total emittance data suggests a slight decrease in total emittance with increasing temperature, although the emittance value stabilizes with continuing exposure.

Grinberg, I. M.↗

Solar irradiance - Total and spectral and its possible variations

The present status of our knowledge of the total and spectral irradiance of the sun is briefly reviewed. The currently accepted NASA/ASTM standard values of the solar constant and the extraterrestrial solar spectral irradiance are presented. The uncertainties in these values are relatively high. Data on the variability of the solar constant are conflicting and inconclusive. The variability of solar spectral irradiance is almost totally unknown and unexplored. Some alleged sun-weather relationships are cited in support of the need to know more precisely the variations in total and spectral solar irradiance. An overview of the solar monitoring program of NASA is presented, with special emphasis on the Solar Energy Monitor in Space (SEMIS) experiment which has been proposed for several spacecraft missions. The monitor is a combination of a solar-constant detector and a prism monochromator.

Thekaekara, M. P.↗

Optical design of the SBUV/TOMS experiment on Nimbus G

The paper examines the tradeoffs performed in optimizing the optical design of the solar backscatter ultraviolet/total ozone mapping spectrometer (SBUV/TOMS) experiment on Nimbus G to stringent performance requirements within the limitations of the spacecraft interface. The SBUV portion of the experiment incorporates a double monochromator optimized for better than 1.0 A spectral resolution over the wavelength range 1600-4000 A. The TOMS portion of the experiment is a stepped line scanning system with a 105-deg total field of view. Special techniques are used to reduce the polarization sensitivity of the instrument to less than 5% for 100% linearly polarized incident radiation and to keep the spectral stray light to less than 0.000001 of the incident solar spectrum. Optical material selection is imperative in order to minimize the effects of fluorescence and phosphorescence arising from the bombardment of particulate radiation in space.

Henderson, B. D.↗

Absolute integrated intensity for the 3.44-microns NO2 band

A grating monochromator infrared spectrometer and a curve of growth technique were used to obtain the absolute integrated intensity for the 3.44 micron NO2 vibration-rotation band at very small NO2 partial pressures. The intensity was found to be 78.9 plus or minus 1.6/cm/(atm cm) at 296 K at the 95% confidence level. The study has relevance to the infrared spectral measurement of atmospheric NO2.

Shafer, J. H.↗

Television cameras employing solid-state imaging sensors for manned spacecraft applications

The Space Shuttle television system incorporates a versatile complement of TV equipment which allows the positioning, quantity, and performance capabilities of the multiple TV cameras to vary as dictated by the particular mission. However, current TV camera technology employing glass enclosed, vacuum processed image sensors results in a bulky device that restricts its location and versatility. Problems and potential solutions that can be achieved through the employment of solid-state image sensors for both monochrome and color applications are discussed.

Embrey, B. C., Jr.↗

Apparatus for experimental investigation of aerodynamic radiation with absorption by ablation products

A description is given and calibration procedures are presented for an apparatus that is used to simulate aerodynamic radiant heating during planetary entry. The primary function of the apparatus is to simulate the spectral distribution of shock layer radiation and to determine absorption effects of simulated ablation products which are injected into the stagnation region flow field. An electric arc heater is used to heat gas mixtures that represent the planetary atmospheres of interest. Spectral measurements are made with a vacuum ultraviolet scanning monochromator.

Wells, W. L.↗

High Resolution Ozone Mapper (HROM)

Using the backscatter ultraviolet instrument (BUV) aboard NIMBUS 4 as a baseline, point scanner mechanisms and spatial multiplex scanning systems were compared on the basis of sensitivity, field of view and simplicity. This comparison included both spectral and spatial scanning and multiplexing techniques. The selected system which optimally met the performance requirements for a shuttle based instrument was a pushbroom spatial scanner using a 15 element photomultiplier tube array and a Hadamard multiplex spectral scan. The selected system was conceptually designed. This design includes ray traces of the monochromator, mechanical layouts and the electronic block diagram.

Kohr, J. R.↗

Collection efficiency measurements for solar cell research

A system was established for measuring absolute, spectral collection efficiency that is well suited to solar cell research and development. Determination of spectral collection efficiency involves measurements of the incident photon intensity, the device reflection coefficient, and the cell short circuit current. A monochromatic photon flux is obtained with a high intensity Bausch and Lomb monochromator, and an Epply thermopile detector is used to measure incident intensity. Normal incidence reflectivity measurements are achieved with a prism type beam splitter. The experimental approach is discussed, measurements of the reflectivity of evaporated silver films are considered. Collection efficiency measurements of silicon solar cells are presented, and collection efficiency studies of Cu20 solar cells are discussed.

Hampton, H. L.↗

Collision-induced absorption of O2 in the Herzberg continuum

Using a one meter normal incidence grating monochromator, the total absorption of radiation for O2 has been reinvestigated between 2000-2500 A. The absorption cross sections of O2 and O4 are then derived from total absorption measurements and compared with other available data. Additional measurements of O2 absorption have been made in the presence of Ar which does not absorb in this spectral region and is chemically inactive with O2. It is found that the absorption of oxygen increases in the presence of Ar, which is interpreted as due to the formation of O2-Ar dimers.

SHARDANAND↗

Laboratory studies of the diffuse reflectance spectra of frosts and minerals occurring on astronomical objects

A vacuum monochromator was integrated into the system and optics chosen to increase data collection in the infrared spectral region. Using a InSb detector, good reflectance data was obtained to 5.5 micron from a variety of samples including magnesium oxide, barium sulfate, water frost and Bloedite. Magnesium oxide was found to be a poorer reflector than the barium sulfate throughout the visible and near infrared region. The barium sulfate material was shown to be a Lambert reflector in the visible region and over an angular range of 60 deg. Several samples of water frost were prepared and in reflectance measured from 0.3 micron to 5.5 microm. The fine grained frosts were better reflectors than the coarse grained frosts, usually by 20 percent or more, over the entire spectral range. The minerals Bloedite and sulfur were also investigated further.

Glaser, F. M.↗

Nitrogen-induced absorption of oxygen in the Herzberg continuum

Total absorption of O2 induced by collisions with N2 has been measured at room temperature in the Hersberg continuum using a one meter normal incidence grating monochromator. The enhanced absorption is ascribed to the formation of O2-O2 and O2-N2 dimers. The interaction constants for these dimers are determined and utilized to investigate their effect on the absorption of solar radiation in the stratosphere.

Shardanand, MR.↗

Measuring concave diffraction grating efficiencies at grazing incidence

The efficiency of a concave diffraction grating in a given order is obtained by measuring the intensities of the diffracted and incident beams and taking their ratio. A valid measurement requires that both the incident and diffracted beams be collected by the detector. At grazing incidence, however, the diffracted beam may spread beyond the detector due to aberrations. In addition, the diffracted beams of consecutive orders may overlap so that unambiguous efficiency measurements cannot be made. The effect of aberrations on efficiency measurements has been studied, using ray tracing, for the geometry of the measuring instrument in use at the Naval Research Laboratory. This instrument is attached to a VUV monochromator which furnishes a diverging beam. The main effect of aberrations for this instrument is a spread of the diffracted beam in the direction of dispersion. The width of the diffracted beam is wavelength dependent and is minimal at the horizontal focus, spreading to longer and shorter wavelengths. Reducing the divergence of the incident beam reduces the spread but, for small radius gratings, not always sufficiently so that the entire diffracted beam can be collected by the detector. The distance from the detector to the grating can also be adjusted to aid in collecting all the diffracted beam.

Hunter, W. R.↗