Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “minimum energy control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Industrial Stormwater Pollution Prevention Plan (SWPPP) for SNL/CA Reporting Year 2022-2023

The Sandia National Laboratories, California (SNL/CA) site comprises approximately 410 acres and is located in the eastern portion of Livermore, Alameda County, California. The property is owned by the United States Department of Energy and is being managed and operated by National Technology & Engineering Solutions of Sandia, LLC. The facility location is shown on the Site Map(s) in Appendix A. This Stormwater Pollution Prevention Plan (SWPPP) is designed to comply with California’s General Permit for Stormwater Discharges Associated with Industrial Activities (General Permit) Order No. 2015-0122-DWQ (NPDES No. CAS000001) issued by the State Water Resources Control Board (State Water Board) (Ref. 6.1). This SWPPP has been prepared following the SWPPP Template provided on the California Stormwater Quality Association Stormwater Best Management Practice Handbook Portal: Industrial and Commercial (CASQA 2014). In accordance with the General Permit, Section X.A, this SWPPP contains the following required elements: Facility Name and Contact Information; Site Map; List of Significant Industrial Materials; Description of Potential Pollution Sources; Assessment of Potential Pollutant Sources; Minimum BMPs; Advanced BMPs, if applicable; Monitoring Implementation Plan (MIP); Annual Comprehensive Facility Compliance Evaluation (Annual Evaluation); and, Date that SWPPP was Initially Prepared and the Date of Each SWPPP Amendment, if Applicable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Role of the Solvent–Surfactant Duality of Ionic Liquids in Directing Two-Dimensional Particle Assembly

Nanoparticle self-assembly plays a key role in formation of superlattices, which exhibit remarkable physical and chemical properties. However, controlling assembly remains a challenge partly due to a lack of understanding of the assembly dynamics and the difficulty in linking interfacial solution properties to interparticle forces. In this study, using liquid-cell transmission electron microscopy, self-assembly of gold nanoparticles (NPs) into superlattices in mixtures of water and ionic liquid (IL) was visualized, revealing a dual role of the IL in the assembly process. At intermediate concentrations, the IL acts as a surfactant stabilizing the particles at a well-defined equilibrium separation corresponding to the length of hydrogen bonded IL cations adsorbed onto neighboring NPs. Analysis of the interparticle forces reveals attractive long-range interactions of a van der Waals nature. At separations of 1-3 nm, interactions are dominated by attractive ion correlation and repulsive hydration forces giving rise to an energy minimum at 1.5 nm separation. The superlattice is further stabilized by hydrogen bonding, which shifts the equilibrium interparticle distance to 1.1 nm. In contrast, at higher concentrations, IL accumulates and forms a structured network in the gap between nanoparticles, where it acts as a solvent that eliminates the repulsive barrier and thus promotes particle coalescence. This solvent-surfactant duality of IL opens new opportunities for their use in directing particle assembly.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Maps of land surface phenology derived from PlanetScope data, 2018-2022, Teller, Kougarok, and Council, Seward Peninsula

Remote sensing maps of land surface phenology derived from PlanetScope (Planet Team, 2017) normalized differential greenness index (NDGI; Yang et al., 2019) time series data. These maps include four phenological timing metric - start of spring (SOS), end of spring (EOS), start of fall (SOF), and end of fall (EOF), corresponding NDGI value at the four phenological timings, and annual maximum and minimum NDGI. This package includes maps for Next-Generation Ecosystem Experiment Arctic (NGEE Arctic)’s Teller Mile Marker (MM) 27, Kougarok MM64, and Council MM 71 watersheds. Maps of 5 years from 2018 to 2022 are included in this dataset. The map data and metadata are provided as image (ENVI) and text (*.txt, *hdr) formats. Additional supporting map quicklooks are provided as GIS *.kml files. These datasets are provided in support of Yang et al., (In revision) “Fine-scale Landscape Characteristics, Vegetation Composition, and Snowmelt Timing Control Phenological Heterogeneity across Arctic Tundra Landscapes”The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Demonstration and technoeconomic analysis of dodecanol production from acetate using metabolically engineered Escherichia coli

In a circular bioeconomy, the one-way conversion of petroleum to chemicals and CO 2 is replaced with processes that reduce CO 2 to energy carriers and useful materials that are returned to CO 2 upon combustion. A circular bioeconomy that relies on photosynthesis to generate sugars as the chief energy carrier and precursor to chemical building blocks has yet to overcome many recalcitrant aspects of plant-based photosynthesis, namely, high feedstock costs, arable land scarcity, food competition, and fertilizer overuse. Acetate is a potential sustainable energy carrier because it can be produced from CO 2 either electrocatalytically or by acetogens via the Wood-Ljungdahl pathway. Here, in this work, we conducted a metabolic engineering study of Escherichia coli 's ability to convert acetate into dodecanol as a model oleochemical product. We performed techno-economic and life cycle analyses to determine break-even points with alternative fossil fuel-based strategies and identified critical process performance parameters for supporting an industrial acetate-based bioprocess. These analyses showed that oleochemical yield is the primary driver of minimum oleochemical selling price and carbon intensity. Therefore, to increase yield on acetate, we deleted the aceBAK operon, which facilitates funneling of acetate into biomass instead of product. We performed additional strain engineering to increase flux towards dodecanol and increase acetate uptake. Finally, we demonstrated increased yield in controlled bioreactors, improving from 13% of the maximum theoretical yield to 37%. Rigorous uncertainty analyses assuming a range of market conditions and future technological performances resulted in 88% and 37% of simulated scenarios having lower carbon intensities than fossil fuel-based routes and lower minimum selling prices than the market price.

Acetate↗

Remote Monitoring and Diagnostics of Pitch-Bearing Defects in an MW-Scale Wind Turbine Using Pitch Symmetrical-Component Analysis

Recently, multiple wind turbine failure databases have reviewed that the pitch system is one of the subassemblies with the highest failure rates and largest contributors to the overall downtime. Therefore, there has been an increasing interest to provide remote health monitoring for wind turbine pitch system. While most of the research articles are discussing pitch actuation system (hydraulic or electric actuator) faults only, there is very limited research on pitch-bearing-defect detection. This article provides a remote and hardware-free solution to monitor multiaxis pitch-bearing health condition called pitch symmetrical-component analysis. It leverages readily available low-resolution (100 Hz) electrical measurements, mechanical measurements, and control signals from the existing pitch control platform, and innovatively applies symmetrical-component analysis in multiphase ac system to multiaxis pitch control system and introduces multiaxis pitch-bearing degradation trending curves. This hardware-free solution can be directly applied to the existing wind turbines and successfully give the wind farm operator an early warning before multiaxis pitch bearing fails. It has been proved to be accurate, low cost, and has minimum impacts on turbine normal operation, and has been validated by field data from several North America MW-scale wind farms. This approach turns out to be the first hardware-free (no additional hardware needed) method to remotely monitor and diagnose multiaxis wind turbine pitch-bearing condition.

17 WIND ENERGY↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Sensitivity Study of Mini-Batch Size on a Long Short-Term Memory Network for In-situ Sensing of Core-to-shell Ratio of Microencapsulated Phase Change Materials

Microencapsulated phase change materials are being studied for applications for thermal energy storage in concentrated solar fields. During fabrication, the thickness of the encapsulation cannot be readily measured for real-time control. Therefore, a machine learning network, specifically a Long Short-Term Memory network, is being developed to estimate the ratio of the shell radius to core radius based on a one second temperature history. The mini-batch size determines how often the algorithm weights are updated during network training, and shuffle indicates whether the training data is shuffled during training. A general factorial design is used to analyze the effects of varying mini-batch size and shuffle, along with the core-to-shell ratio, on the RMSE of the response from the Long Short-Term Memory network. It was found that the network performed better for smaller core to shell ratios (less than 0.6) and had the lowest RMSE when the minibatch size was 128. The minimum RMSE found was 0.00501.

Shannon, Rebecca↗

Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate

Unvented roof assemblies have been accepted in North American building codes since 2007; code-compliant construction calls for a minimum thickness of “air-impermeable insulation” (based on climate zone) to avoid cold-weather condensation and moisture risks. This is typically implemented with polyurethane spray foam insulation; however, negatives of this material include high first cost and possible adverse environmental impacts. Implementing unvented roofs in a moisture-safe manner with air-permeable fibrous fill insulations (e.g., fiberglass or cellulose) could potentially reduce the first cost of unvented roof designs, allowing for more widespread use. Building unvented roofs in a cost-effective, airtight, and moisture-safe manner opens up options for high-performance house designers and builders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Defensive Islanding to Enhance the Resilience of Distribution Systems Against Cyber-Induced Failures

The extensive integration of communication, computation, and control technologies into cyber-physical power systems (CPPSs) has increased the vulnerabilities of CPPSs to cyberattacks. This calls for developing solutions that assess and reduce the impacts of cyber-induced failures on CPPSs. This paper proposes a defensive islanding strategy to isolate impacted parts of the CPPS and form self-sufficient islanded grids with an objective of minimum load curtailment. The defensive islanding aims to split a power system into smaller grids to improve its resilience against a potential extreme event. A clustering approach that leverages the hierarchical spectral clustering method is utilized for the optimal defensive islanding. The proposed approach captures the fragility behavior and loading conditions of power system components due to cyber-induced failures. A graphical-based coupling framework is used to map the impacts of cyber failures into operation of power system components. The proposed method is demonstrated on a modified 33-node distribution feeder system integrated with distributed energy resources. The amount of load curtailment and radiality constraints have been used to evaluate the performance of the proposed clustering strategies. The results show the capability of the proposed algorithm to create islands considering the cyber-induced failures for enhanced resilience.

cyber-induced failures↗

CY2019 Annual Closure Monitoring Report for Corrective Action Unit 98, Frenchman Flat, Underground Test Area, Nevada National Security Site, Nevada (January 2019–December 2019), Revision 1

Three types of monitoring are performed for CAU 98: water quality, water level, and institutional control. These are monitored to determine whether the URs remain protective of human health and the environment, and to ensure that the regulatory boundary objectives are being met. Monitoring data will be used in the future, once multiple years of data are available, to evaluate consistency with the groundwater flow and contaminant transport models because the contaminant boundaries calculated with the models are the primary basis of the UR boundaries. Six wells were sampled for water-quality monitoring in 2019. Contaminants of concern were detected only in the two source/plume wells already known to contain contamination as a result of a radionuclide migration experiment. Tritium concentrations in both of these wells, RNM-2S and UE-5n, remain above the Safe Drinking Water Act maximum contaminant level of 20,000 picocuries per liter but declined in 2019 as compared to measurements in 2018. All other contaminants of concern are below the minimum detection level plus analytical error. The water-level monitoring network includes 16 wells. Depth to water measured in 2019 is generally consistent with recent measurements for all wells. Many wells continue to exhibit a long-term downward trend in water level, though changes from 2018 to 2019 are minimal. The sharp 2016 decline in water level in Well ER-5-3-2 remains unexplained, with the lower level persisting through 2019. Rising water-level trends continue to be observed in Well ER-5-3 deep piezometer and former water supply Well WW-5A. Water supply Well WW-5B experienced a rise in water level as a result of an absence of pumping in the first part of the year (due to a mechanical problem), whereas water levels declined in WW-4 and WW-4A in response to greater pumping in 2019. Institutional control monitoring confirmed the URs are recorded in U.S. Department of Energy and U.S. Air Force land management systems, and that no activities within Frenchman Flat basin are occurring that could potentially affect the contaminant boundaries. Survey of groundwater resources in basins surrounding Frenchman Flat similarly identify no current or pending development that would indicate the need to increase monitoring activities or would otherwise cause concern for the closure decision. The URs continue to prevent exposure of the public, workers, and the environment to contaminants of concern by preventing use of potentially contaminated groundwater.

54 ENVIRONMENTAL SCIENCES↗

Operating Strategies for Dispatchable PEM Electrolyzers that Enable Low-Cost Hydrogen Production

Hydrogen is a pathway to enabling decarbonization across multiple economic sectors that cannot be directly decarbonized with electricity including heat for industrial operations, medium- and heavy-duty transportation applications, long-duration energy storage, and as a feedstock for chemical synthesis. Producing hydrogen at low costs and carbon footprint is likely essential to economically decarbonize these otherwise "hard to decarbonize" sectors. Low-temperature polymer electrolyte membrane (PEM) electrolysis produces hydrogen from water and electricity and is a rapidly developing pathway towards making hydrogen at the scales required for decarbonization applications. The levelized cost of electrolytic hydrogen is dependent on the capital cost, efficiency, and durability of the electrolyzer system as well as the price of electricity supplied to the electrolyzer and the annual utilization of the electrolyzer (capacity factor). Electricity price and capacity factor depend on the source of energy that the system uses and impact other economic factors. Electricity price and capacity factor and the connections between other aspects of hydrogen production via PEM electrolyzers are the focus of this work. PEM electrolyzers have conventionally been operated at high capacity factors using electricity purchased from utilities with a constant price throughout the year. To achieve lower effective electricity prices, recent work has investigated opportunities for electrolyzers to purchase electricity in wholesale markets, where the cost of electricity varies hourly. This option can lead to lower electricity costs when the electrolyzer is a controllable load that ramps up and down rapidly and turns on and off frequently. This configuration and operating strategy capitalizes on times of low wholesale electricity prices and results in lower hydrogen levelized costs than constant operation due to reduced electricity costs even though the reduced capacity factor increases the cost of recovering the capital investment. Cycling on and off frequently also has implications for electrolyzer durability. An electrolyzer configuration where it is directly connected to renewable generation such as wind or solar, only running when the generator is producing energy, has similar implications on operating strategy, hydrogen levelized cost, capacity factor, and durability. This work provides insight into the relationships between dispatchable electrolyzer operating strategies and the cost of producing hydrogen from these systems, outlining strategies and opportunities to minimize production costs while minimizing operations that are likely to negatively impact system durability and efficiency. We find strategies that minimize electrolyzer cycling and the resulting durability impacts while increasing the hydrogen levelized cost only slightly above the minimum. We also find opportunities for batteries to minimize the number of cycles in systems directly connected to renewable generation. These findings outline key opportunities for future electrolyzer deployments and the synergistic benefits between electrolyzers and increased deployment of renewable energy generation like wind and solar. They also inform research and development that is reducing electrolyzer capital cost while managing durability impacts.

electricity markets↗

Extended Low Load Boiler Operation to Improve Performance and Economics of an Existing Coal Fired Power Plant (Final Report)

The overall goal is to improve the performance and economics of existing coal fired power plants by extending low load boiler operation to lower loads than is currently achievable. The objective of this program is to develop and validate sensor hardware and analytical algorithms to lower plant operating expenses (OPEX) for the currently operating pulverized coal utility boiler fleet. Coal fired utility boilers are increasingly under grid dispatch pressure. In some cases, the coal fired cost of generation is noncompetitive with respect to natural gas generation and subsidized renewable sources. To remain profitable and remain fully compliant with existing environmental regulations, the installed coal fired fleet must find technologies which allow it to move into a more flexible cyclic load dispatch model. Today the installed coal fired utility fleet must be cost of generation competitive, fully emissions compliant, and responsive to the variability inherent in renewable energy generation sources. In the Phase I of the project, GE Steam Power, Inc. (GE) performed modeling of different operating scenarios for low load operation using an existing full plant dynamic model developed for a 660MW steam power plant. Sensors and analytic algorithms to enable a stable and steady coal supply for low load pulverizer operation were identified and tested at the Pulverizer Development Facility (PDF) at GE’s Clean Energy Center in Bloomfield, Connecticut. Sensors and analytic algorithms to enable stable combustion for low load operation were identified and tested at the 15 MWth Industrial Scale Burner facility (ISBF) at GE’s Clean Energy Center. A concept was developed to test the sensors and control algorithms, down selected after testing, at a full-scale coal fired power plant. A budget estimate was then developed, and the concept was implemented at an existing utility power plant. The specific objectives of the experimental work were to: • Identify and select sensors and analytic algorithms for monitoring coal pulverizer operation at lower loads to provide stable operation and appropriate coal fineness at lower coal throughput; Identify and select sensors and analytic algorithms for a Boiler Flame Stability Monitor to better balance air and fuel at each burner. This enables a reduction in a coal boiler’s safe low load power level while maintaining stable flame characteristics; Develop a concept in Phase I for low load operation of a full-scale power plant and develop a budget estimate for testing and execute the test plan at an existing plant in Phase II; Validate the capability of the extended low load boiler system to extend the minimum load operating point in a safe and reliable manner on an existing full-scale utility boiler. At the completion of this experimental study, GE has developed a set of sensors and analytic algorithms, down selected after testing, that have the potential to enable safe low load operation of a utility boiler. GE has also identified a host site for testing these identified sensors and analytic algorithms. GE has generated a full set of deliverables that provide sufficient information to proceed with the next step of testing at a host site. This includes a potential host site and budget estimate for concept testing at host site. In the Phase II of the project, a series of field tests were completed to validate the extended low load boiler operation, which consisted of detailed engineering, installation, commissioning, and testing the additional sensors and analytics for the coal-fired combustion system on an existing full-scale utility boiler. The optimization work has been supported by the host plant and endorsed by their engineering and operation staff.

01 COAL, LIGNITE, AND PEAT↗

Design, Optimization, and Validation of GaN-Based DAB Converter for Active Cell Balancing in BTMS Applications: Preprint

This paper focuses on the design of a bidirectional dual active bridge (DAB) DC/DC converter that utilizes Gallium Nitride (GaN) switches as active components. In the existing literature, MOSFET-based DAB for active cell balancing is available, but GaN-based DAB converter for active cell balancing is still new. The proposed modular isolated GaN-based DAB converter is designed as an individual module of active cell balancing for behind-the-meter storage (BTMS) applications, targeting high-power charging stations. Modular isolated converters are connected to each cell (low voltage bus), and each cell is connected in series to build up a battery module. According to the reference current command of supervisory control, each DAB converter can transfer power back and forth through the high voltage (HV) bus to balance the State of Charge (SoC) between the cells. Each module DAB converter is designed at a 50W power rating. Switch power and transformer losses are analyzed for different switching frequencies, showing the optimum switching frequency for minimum losses. Furthermore, the procedure to select the required gate driver and the PCB layout optimization are discussed. Finally, the DAB performance analysis of GaNbased DAB and Si-based DAB is provided for a battery module operating with a LiFeMnPO4 prismatic cell with 3.2V 20Ah rated values.

active cell balancing↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Transmission-distribution long-term volt-var planning considering reactive power support capability of distributed PV

High penetration of grid-edge, inverter-based photovoltaic (PV) can cause significant voltage fluctuations not only at the distribution but also at the sub-transmission levels due to PV output intermittency. Traditional reactive power planning approaches do not consider intermittency, nor the possibility of coordinating the control of existing and future volt-ampere reactive resources. This paper proposes a reactive power planning tool for sub-transmission systems to mitigate voltage violations and fluctuations caused by high PV penetration and intermittency with a minimum investment cost. The planning tool coordinates with an optimization-based volt-var operational tool for: a) modeling the coordination of all existing var assets in both sub-transmission and distribution systems to reduce the need of new equipment, and b)selecting a set of scenarios with voltage violations, derived from PV intermittency c) testing the final investment decision. The tool obtains an investment need for each intermittency scenario with a proposed optimal power-flow framework with efficient techniques to handle a high number of discrete variables. Two options are provided for final planning decision: i) a conservative direct combination of investment need solutions and ii) a machine learning-based selection of representative investment needs at most time steps. The final investment decision options are verified using a realistic large-scale sub-transmission system and 5-minute PV and load data. The results show a significant voltage performance improvement with a lower investment cost for additional var equipment compared to conventional approaches.

14 SOLAR ENERGY↗

Probing Quantum Speed Limits with Ultracold Gases

Here, quantum speed limits (QSLs) rule the minimum time for a quantum state to evolve into a distinguishable state in an arbitrary physical process. These fundamental results constrain a notion of distance traveled by the quantum state, known as the Bures angle, in terms of the speed of evolution set by nonadiabatic energy fluctuations. I theoretically propose how to measure QSLs in an ultracold quantum gas confined in a time-dependent harmonic trap. In this highly-dimensional system of continuous variables, quantum tomography is prohibited. Yet, QSLs can be probed whenever the dynamics is self-similar by measuring as a function of time the cloud size of the ultracold gas. This makes it possible to determine the Bures angle and energy fluctuations, as I discuss for various ultracold atomic systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deep Reinforcement Learning Based Smart Water Heater Control for Reducing Electricity Consumption and Carbon Emission

Water heating is the third largest electricity consumer in U.S. households, after space heating and cooling. Thus, water heaters represent a significant potential for reducing electricity consumption and associated CO2 emissions of residential buildings. To this end, this study proposes a model-free deep reinforcement learning (RL) approach that aims to minimize the electricity consumption and the CO2 emissions of a heat pump water heater without affecting user comfort. In this approach, a set of RL agents focusing on either electricity saving or emission reduction, with different look ahead periods, were trained using the deep Q-networks (DQN) algorithm and their performance was tested on different hot water usage and Marginal Operating Emissions Rate (MOER) profiles. The testing results showed that the RL agents that focus on electricity saving can save electricity in the range of 12–22% by operating the water heater with maximum heat pump efficiency and minimum electric element utilization. On the other hand, the RL agents that focus on emission reduction reduced emissions in the range of 18–37% by making use of the variable MOER values. These RL agents used the heat pump and/or an element when the MOER values are low due to the availability of renewable energy sources (e.g., solar and wind) and mostly avoided the periods of carbon-intensive periods. Overall, these results showed that the proposed RL approach can help minimize the electricity consumption and the CO2 emissions of a heat pump water heater without having any prior knowledge about the device.

Amasyali, Kadir↗

Design, Optimization, and Validation of GaN-Based DAB Converter for Active Cell Balancing in BTMS Applications

This paper focuses on the design of a bidirectional dual active bridge (DAB) DC/DC converter that utilizes Gallium Nitride (GaN) switches as active components. In the existing literature, MOSFET-based DAB for active cell balancing is available, but GaN-based DAB converter for active cell balancing is still new. The proposed modular isolated GaN-based DAB converter is designed as an individual module of active cell balancing for behind-the-meter storage (BTMS) applications, targeting high-power charging stations. Modular isolated converters are connected to each cell (low voltage bus), and each cell is connected in series to build up a battery module. According to the reference current command of supervisory control, each DAB converter can transfer power back and forth through the high voltage (HV) bus to balance the State of Charge (SoC) between the cells. Each module DAB converter is designed at a 50 W power rating. Switch power and transformer losses are analyzed for different switching frequencies, showing the optimum switching frequency for minimum losses. Furthermore, the procedure to select the required gate driver and the PCB layout optimization are discussed. Finally, the DAB performance analysis of GaN-based DAB and Si-based DAB is provided for a battery module operating with a LiFeMnPO4 prismatic cell with 3.2V 20Ah rated values.

active cell balancing↗